Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASURING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An Analysis of the Selected Materials Used in Step Measurements During Pre-Fits of Thermal Protection System Tiles and the Accuracy of Measurements Made Using These Selected Materials

The goal of this research project was be to compare and contrast the selected materials used in step measurements during pre-fits of thermal protection system tiles and to compare and contrast the accuracy of measurements made using these selected materials. The reasoning for conducting this test was to obtain a clearer understanding to which of these materials may yield the highest accuracy rate of exacting measurements in comparison to the completed tile bond. These results in turn will be presented to United Space Alliance and Boeing North America for their own analysis and determination. Aerospace structures operate under extreme thermal environments. Hot external aerothermal environments in high Mach number flights lead to high structural temperatures. The differences between tile heights from one to another are very critical during these high Mach reentries. The Space Shuttle Thermal Protection System is a very delicate and highly calculated system. The thermal tiles on the ship are measured to within an accuracy of .001 of an inch. The accuracy of these tile measurements is critical to a successful reentry of an orbiter. This is why it is necessary to find the most accurate method for measuring the height of each tile in comparison to each of the other tiles. The test results indicated that there were indeed differences in the selected materials used in step measurements during prefits of Thermal Protection System Tiles and that Bees' Wax yielded a higher rate of accuracy when compared to the baseline test. In addition, testing for experience level in accuracy yielded no evidence of difference to be found. Lastly the use of the Trammel tool over the Shim Pack yielded variable difference for those tests.

Kranz, David William↗

Measurement System Characterization in the Presence of Measurement Errors

In the calibration of a measurement system, data are collected in order to estimate a mathematical model between one or more factors of interest and a response. Ordinary least squares is a method employed to estimate the regression coefficients in the model. The method assumes that the factors are known without error; yet, it is implicitly known that the factors contain some uncertainty. In the literature, this uncertainty is known as measurement error. The measurement error affects both the estimates of the model coefficients and the prediction, or residual, errors. There are some methods, such as orthogonal least squares, that are employed in situations where measurement errors exist, but these methods do not directly incorporate the magnitude of the measurement errors. This research proposes a new method, known as modified least squares, that combines the principles of least squares with knowledge about the measurement errors. This knowledge is expressed in terms of the variance ratio - the ratio of response error variance to measurement error variance.

Commo, Sean A.↗

High-resolution grazing-incidence grating spectrometer for temperature measurements of low-Z ions emitting in the 100–300 Å spectral band

We have constructed a high-resolution grazing-incidence spectrometer designed for measuring the ion temperature of low-Z elements, such as Li{sup +} or Li{sup 2+}, which radiate near 199 Å and 135 Å, respectively. Based on measurements at the Livermore Electron Beam Ion Trap we have shown that the instrumental resolution is better than 48 mÅ at the 200 Å setting and better than 40 mÅ for the 135-Å range. Such a high spectral resolution corresponds to an instrumental limit for line-width based temperature measurements of about 45 eV for the 199 Å Li{sup +} and 65 eV for the 135 Å Li{sup 2+} lines. Recently obtained survey spectra from the Lithium Tokamak Experiment at the Princeton Plasma Physics Laboratory show the presence of these lithium emission lines and the expected core ion temperature of approximately 70 eV is sufficiently high to demonstrate the feasibility of utilizing our high-resolution spectrometer as an ion-temperature diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrate the Out-of-Pile Performance of a Real-Time Measurement System to Measure Thermal Conductivity Based on Photo Thermal Radiometry

SUMMARY The goal of this project is to develop a fiber-based instrument to perform in-reactor thermal conductivity measurements of fuels and materials. This instrument is based on photothermal radiometry (PTR) and involves heating a sample locally and measuring the induced temperature gradient by collecting blackbody radiation [2]. Thermal conductivity of the sample is extracted by comparing experimental results with a continuum-based model [3,4]. As a laser-based technique, PTR is a non-contact measurement technique that can be performed remotely and non-destructively. In addition, it has several advantages over other photothermal techniques, making it an ideal approach for in-situ measurement of thermal conductivity of nuclear fuels. Because blackbody radiation increases with emissivity and temperature, the PTR technique works well with unprepared surfaces, and measurement accuracy increases with temperature. Moreover, this approach is capable of measuring samples with irregular or poorly defined boundary conditions, which is a common situation for friable spent fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of the Polarization Observables I{sup s} and I{sup c} for {gamma}{sup {yields}p{yields}}p{pi}{sup +{pi}-} using the CLAS Spectrometer

Model predictions regarding the excited baryon spectrum provided by Constituent Quark Models show good agreement with experimental measurements in the low-energy region less than {approx_equal}1.8 GeV. The mass region above {approx_equal}1.8 GeV, however, contains many resonances which are predicted to exist by these models but have not been experimentally verified. The analysis of a double meson final state using linearly polarized photoproduction data allows access to two polarization observables, I{sup s} and I{sup c}(also known as the beam asymmetry {Sigma} for a single meson final state). It has been shown that measurements of these polarizaton observables can provide insight into this missing resonance problem. This analysis was carried out on data taken from the CLAS-g8b data run period conducted at Jefferson Lab in Newport News, Virginia. The analysis of this data and preliminary measurements of these obsevables will be dicussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Hard X-ray Lens Wavefront Aberrations using Phase Retrieval

Measuring the deviation of a wavefront from a sphere provides valuable feedback on lens alignment and manufacturing errors. We demonstrate that these aberrations can be accurately measured at hard x-ray wavelengths, from far-field intensity measurements, using phase retrieval with a moveable structure in the beam path. We induce aberrations on a hard x-ray kinoform lens through deliberate misalignment and show that the reconstructed wavefronts are in good agreement with numerical simulations. Reconstructions from independent data, with the structure at different longitudinal positions and significantly separated from the beam focus, agreed with a root mean squared error of 0.006 waves.

42 ENGINEERING↗

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high temperature apparatus for measurement of the Seebeck coefficient

A high temperature Seebeck coefficient measurement apparatus with various features to minimize typical sources of error is designed and built. Common sources of temperature and voltage measurement error are described and principles to overcome these are proposed. With these guiding principles, a high temperature Seebeck measurement apparatus with a uniaxial 4-point contact geometry is designed to operate from room temperature to over 1200 K. This instrument design is simple to operate, and suitable for bulk samples with a broad range of physical types and shapes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of the Compton Form Factor H from DVCS Measurements in the Quark Sector

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A, the beam spin asymmetries measured in Hall B at Jefferson Laboratory and beam charge, beam spin and target spin asymmetries measured by Hermes. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20-50 % uncertainty. We pay extra attention to the estimation of systematic errors on the extraction of H. We discuss our results and compare to other extractions as well as to the popular VGG model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock- and compression-bang time at the NIF (invited)

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using D{sup 3}He-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase D{sup 3}He-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock- and compression-bang times in D{sup 3}He-filled surrogate implosions at the NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density and gas density measurements in a millimeter-wave discharge

Electron density and neutral gas density have been measured in a non-equilibrium air breakdown plasma using optical emission spectroscopy and two-dimensional laser interferometry, respectively. A plasma was created with a focused high frequency microwave beam in air. Experiments were run with 110 GHz and 124.5 GHz microwaves at powers up to 1.2 MW. Microwave pulses were 3 μs long at 110 GHz and 2.2 μs long at 124.5 GHz. Electron density was measured over a pressure range of 25 to 700 Torr as the input microwave power was varied. Electron density was found to be close to the critical density, where the collisional plasma frequency is equal to the microwave frequency, over the pressure range studied and to vary weakly with input power. Neutral gas density was measured over a pressure range from 150 to 750 Torr at power levels high above the threshold for initiating breakdown. The two-dimensional structure of the neutral gas density was resolved. Intense, localized heating was found to occur hundreds of nanoseconds after visible plasma formed. This heating led to neutral gas density reductions of greater than 80% where peak plasma densities occurred. Spatial structure and temporal dynamics of gas heating at atmospheric pressure were found to agree well with published numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Precision Mass Measurements of Neutron-Rich Neodymium and Samarium Isotopes and Their Role in Understanding Rare-Earth Peak Formation

The Canadian Penning Trap mass spectrometer at the Californium Rare Isotope Breeder Upgrade (CARIBU) facility was used to measure the masses of eight neutron-rich isotopes of Nd and Sm. These measurements are the first to push into the region of nuclear masses relevant to the formation of the rare-earth abundance peak at A similar to 165 by the rapid neutron-capture process. We compare our results with theoretical predictions obtained from "reverse engineering" the mass surface that best reproduces the observed solar abundances in this region through a Markov chain Monte Carlo technique. Our measured masses are consistent with the reverse-engineering predictions for a neutron star merger wind scenario.

Orford, R.↗