Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Modeling of Am-241 as an alternative fuel source in a radioisotope thermoelectric generator

Radioisotope thermoelectric generators (RTGs) have been utilized in the USA to power satellites and space exploration equipment for over half a century. In our preceding paper, Dustin and Borrelli (2021), we assessed the performance of 241 Am as an alternative to 238 Pu by modeling the specific decay-heat and gamma spectra of several potential radioisotopes in SCALE-ORIGEN, and comparing these with 238 Pu An analysis of heat output, heat stability, safety, availability and required mass showed that of the isotopes reviewed, 241 Am had the greatest potential for replacing 238 Pu, with additional design considerations. In our current work, we have assessed radiation transport for two configurations of an 241 Am powered Multi-Mission Radioisotope Thermoelectric Generator (MMRTG), due to the potential health effects for operators, fabricators, and others with the potential to be exposed to neutrons and lower energy gamma rays. We have modeled the use of americium as a fuel source replacement for plutonium in current MMRTG designs. The assessment has been performed using MCNP6, in terms of neutron and gamma emissions that might interfere with sensitive equipment and power system production. The radiation transport behavior in terms of dose rate of the 241 Am fueled models is compared with that of a 238 Pu fueled model. Finally, additional work was performed to validate modeling simplifications with regards to thermocouple material configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of the Fast-Neutron Irradiator and the Fast-Flux Tube Irradiation Fixtures at the Pennsylvania State Breazeale Reactor

Accurate knowledge of the neutron spectrum at a nuclear research reactor is a prerequisite for planning irradiation experiments, as well as for evaluating irradiation exposure results. The neutron-flux spectrum in the fast-neutron irradiator (FNI) and the fast-flux tube (FFT) irradiation fixtures at the Pennsylvania State Breazeale Reactor (PSBR) were characterized using the multi-foil neutron activation method. These irradiation fixtures make use of graded shielding to produce unique neutron fields. Multiple foil sets were irradiated in the fixtures with different exposure times and reactor powers to understand the stability over a wide range of operating conditions. Measured results were evaluated against a MCNP6 simulation to produce a measurement-informed neutron flux-energy spectrum for each fixture using STAYSL_PNNL. Simulated estimates of the FNI fixture, a newer fixture (~25 years old), demonstrated excellent agreement with measured results; the FFT did not. Thermal neutron measurements from the FFT suggest there is additional thermal leakage not captured in the simulation model. In conclusion, possible explanations for the discrepancy include burn-out or degradation (i.e., micro-cracking, gaps, etc.) in the boral and cadmium liners over the lifetime of the fixture (~40 years old).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking Geant4 for simulating galactic cosmic ray interactions within planetary bodies

Galactic cosmic rays undergo complex nuclear interactions with nuclei within planetary bodies that have little to no atmosphere. Radiation transport simulations are a key tool used in understanding the neutron and gamma-ray albedo coming from these interactions and tracing these signals back to geochemical composition of the target. In this paper, we study the validity of the code Geant4 for simulating such interactions by comparing simulation results to data from the Apollo 17 Lunar Neutron Probe Experiment. Different assumptions regarding the physics are explored to demonstrate how these impact the Geant4 simulation results. In general, all of the Geant4 results over-predict the data, however, certain physics lists perform better than others. Finally, in addition, we show that results from the radiation transport code MCNP6 are similar to those obtained using Geant4.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of integral cross sections of 3 H in Al foils monitors irradiated by protons with energies ranging from 40 to 2600 MeV

Our results of 3 H production in Al foil monitors (~ 59 mg/cm 2 thickness) are presented. We irradiated these foils in 15×15 mm polyethylene bags of ~ 14 mg/cm 2 thickness together with foils of Cr (~ 395 mg/cm 2 thickness) and 56 Fe (~ 332 mg/cm 2 thickness) by protons of different energies in a range of 0.04 – 2.6 GeV. The diameters of all the foils were 10.5 mm. The irradiations were carried out at the ITEP accelerator U–10 under the ISTC Project # 3266 in 2006–2009. 3 H has been extracted from Al foils using an A307 Sample Oxidizer. We then used an ultra low level liquid scintillation spectrometer Quantulus1220 to measure the 3 H β–spectra and the SpectraDec software package was applied for spectra processing, deconvolution and 3 H activity determination. The values of the Al (p, x) 3 H reaction cross sections obtained in these experiments are compared with data measured at other labs and with results of simulations by the MCNP6 radiation transport code using the CEM03.03 event generator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmarking of HEU Mental Annuli Critical Assemblies with Internally Reflected Graphite Cylinder

Three experimental configurations of critical assemblies, performed in 1963 at the Oak Ridge Critical Experiment Facility, which are assembled using three different diameter HEU annuli (15-9 inches, 15-7 inches and 13-7 inches) metal annuli with internally reflected graphite cylinder are evaluated and benchmarked. The experimental uncertainties which are 0.00055, 0.00055 and 0.00055 respectively, and biases to the detailed benchmark models which are -0.00179, -0.00189 and -0.00114 respectively, were determined, and the experimental benchmark keff results were obtained for both detailed and simplified model. The calculation results for both detailed and simplified models using MCNP6-1.0 and ENDF VII.1 agree well to the benchmark experimental results with a difference of less than 0.2%. These are acceptable benchmark experiments for inclusion in the ICSBEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculation of self–shielding factor for neutron activation experiments using GEANT4 and MCNP

The neutron self–shielding factor G as a function of the neutron energy was obtained for 14 pure metallic samples in 1000 isolethargic energy bins from 1·10{sup −5}eV to 2·10{sup 7}eV using Monte Carlo simulations in GEANT4 and MCNP6. The comparison of these two Monte Carlo codes shows small differences in the final self–shielding factor mostly due to the different cross section databases that each program uses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design considerations for three-dimensional betavoltaics

Betavoltaic devices are suitable for delivering low-power over periods of years. Typically, their power density is on the order of nano to micro-Watts per cubic centimeter. In this work we evaluate the potential for using high-aspect ratio three-dimensional semiconductor structures to enhance the power and efficiency of these devices. The Monte Carlo transport code MCNP6 is used to provide realistic estimates of the theoretical levels of charge generation, which is in turn used to make predictions about the power output from three-dimensional betavoltaics. The focus of this work is on silicon and promethium-147, but other semiconductors and radioisotopes are considered as well. In the case of silicon diodes with three-dimensional features that are comparable to what is commercially available we estimate that power densities in the range of 20-25 mW/cm 3 can be achieved at efficiencies of 2.9-5.8% when coupled with promethium-147 oxide.

25 ENERGY STORAGE↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adjoint-Based Sensitivity and Uncertainty Analysis for Density and Composition: A User’s Guide

The ability to perform sensitivity analyses using adjoint-based first-order sensitivity theory has existed for decades. This paper provides guidance on how adjoint sensitivity methods can be used to predict the effect of material density and composition uncertainties in critical experiments, including when these uncertain parameters are correlated or constrained. Two widely used Monte Carlo codes, MCNP6 (Ref. 2) and SCALE 6.2 (Ref. 3), are both capable of computing isotopic density sensitivities in continuous energy and angle. Additionally, Perkó et al. have shown how individual isotope density sensitivities, easily computed using adjoint methods, can be combined to compute constrained first-order sensitivities that may be used in the uncertainty analysis. This paper provides details on how the codes are used to compute first-order sensitivities and how the sensitivities are used in an uncertainty analysis. Constrained first-order sensitivities are computed in a simple example problem.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SENSMG: First-Order Sensitivities of Neutron Reaction Rates, Reaction-Rate Ratios, Leakage, k eff , and α Using PARTISN

SENSMG is a tool for calculating the first-order sensitivities of reaction-rate ratios, k eff , and α in critical problems and reaction-rate ratios, reaction rates, and leakage in fixed-source problems to multigroup cross sections, isotope densities, material mass densities, and interface locations using the PARTISN multigroup discrete-ordinates code by implementing Generalized Perturbation Theory. SENSMG can be used for one-dimensional spherical and slab (r) and two-dimensional cylindrical (r-z) geometries. For fixed-source (leakage) problems, SENSMG relies on the MISC and/or SOURCES4C codes to compute neutron source rate densities from spontaneous fission and (α,n) sources. SENSMG is a combination of Python and Fortran and was developed under Linux. This computer code abstract describes all user inputs, the input file, and output files. Furthermore, this computer code abstract describes how SENSMG can be modified to support different computer platforms, PARTISN versions, or cross-section availability. Several verification problems are presented in which SENSMG results are compared with MCNP6, SCALE6.2, and direct perturbations (central differences).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics↗

Applying ALARA Principles in the Design of New Radiological Facilities

The application of ALARA (As Low As Reasonably Achievable) principles to the design of new radiological facilities at Argonne National Laboratory provides a consistent radiation safety basis for future facility operations. The Department of Energy Rule 10 CFR 835 specifies design objectives to be adopted during the design of new facilities for controlling personal radiation exposure. One is to keep exposure levels below 20% of the applicable standards in 10 CFR 835.202. For a radiation worker 20% of the standard corresponds to 5 µSv hr -1 for a 2,000 hour work year. For a member of the public the DOE design objective corresponds to 0.2 mSv in a calendar year. For a new facility worst case radionuclides and their source strengths are chosen. Local shielding is specified to reduce exposure rates to less than 50 µSv hr -1 at 30 cm from the shielding. The current version MCNP6 of the Los Alamos radiation shielding computer program MCNP is then used to calculate the exposure rates elsewhere. Design modifications are made to meet the criteria. The calculations and resulting facility design modifications are discussed for two new radiological facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗