A new approach to long-life noncontacting electromechanical devices

Brushless dc motors are finding increasing application in space. Likewise, with the advent of the light emitting diode, noncontacting encoders are gradually replacing sliding contact types. The direct drive concept has proved its merit and is now the preferred approach for tape recorders and low to moderate torque instrument drives. The final step in this evolution is the magnetic bearing, which now appears feasible for several applications. Where it can be applied in a totally noncontacting system, life and reliability will be a function of the electronic controls, where redundancy, derating, and quality assurance approaches virtually assure the desired lifetime and failure rate.

Devine, E. J.↗

Landsat-1 and Landsat-2 evaluation report, 23 January 1975 to 23 April 1975

A description of the work accomplished with the Landsat-1 and Landsat-2 satellites during the period 23 Jan. - 23 Apr. 1975 was presented. The following information was given for each satellite: operational summary, orbital parameters, power subsystem, attitude control subsystem, command/clock subsystem, telemetry subsystem, orbit adjust subsystem, magnetic moment compensating assembly, unified S-band/premodulation processor, electrical interface subsystem, thermal subsystem, narrowband tape recorders, wideband telemetry subsystem, attitude measurement sensor, wideband video tape recorders, return beam vidicon, multispectral scanner subsystem, and data collection subsystem.

Source record↗

Landsat-1 and Landsat-2 flight evaluation

The flight performance of Landsat 1 and Landsat 2 is analyzed. Flight operations of the satellites are briefly summarized. Other topics discussed include: orbital parameters; power subsystem; attitude control subsystem; command/clock subsystem; telemetry subsystem; orbit adjust subsystem; magnetic moment compensating assembly; unified s-band/premodulation processor; electrical interface subsystem; thermal subsystem; narrowband tape recorders; wideband telemetry subsystem; attitude measurement sensor; wideband video tape recorders; return beam vidicon; multispectral scanner subsystem; and data collection subsystem.

Source record↗

Advanced crew procedures development techniques

The development of an operational computer program, the Procedures and Performance Program (PPP), is reported which provides a procedures recording and crew/vehicle performance monitoring capability. The PPP provides real time CRT displays and postrun hardcopy of procedures, difference procedures, performance, performance evaluation, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data, and via magnetic tape transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP.

Arbet, J. D.↗

A catalog of jovian decameter-wave radio observations from 1957 - 1978

Data from over 200,000 hours of observation of Jupiter radio emission in the decameter-wavelength band, were collected from 13 observing sites and are available on magnetic tape. Observations were made at 14 fixed frequencies from 5 to 30 MHz. The characteristics of the tape recording technique and the data format are described. The combination of overlapping data from observing sites scattered world-wide lessens the effect of the earth's daily interruption of the ground-received signal. A power spectral analysis of the data shows no evidence of periodicities within the data other than the well-known influences of Jupiter, Io, and the earth. The dependence of the occurrence probability of emission on System 3 longitude and the phase of Io varies smoothly with frequency down to 15 MHz and then appears quite different at 10 MHz. The morphology of the radio sources is both complex and stable for periods of at least months and probably much longer.

Thieman, J. R.↗

Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)

The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.

Lu, L.↗

Conceptual servo technique for controlling tape drivers

Electronic speed control design maintains magnetic tape in close synchronism at the airborne and ground stationed devices. Use of the servo system during the record and reproduce modes results in the minimum amount of frequency distortion and flutter.

Bentley, R.↗

Design study for a high reliability five-year spacecraft tape transport

Following the establishment of the overall transport concept, a study of all of the life limiting constraints associated with the transport were analyzed using modeling techniques. These design techniques included: (1) a response analysis from which the performance of the transport could be determined under operating conditions for a variety of conceptual variations both in a new and aged condition; (2) an analysis of a double cone guidance technique which yielded an optimum design for maximum guidance with minimum tape degradation; (3) an analysis of the tape pack design to eliminate spoking caused by negative tangential stress within the pack; (4) an evaluation of the stress levels experienced by the magnetic tape throughout the system; (5) a general review of the bearing and lubrication technology as applied to satellite recorders and hence the recommendation for using standard load carrying antifriction ball bearings; and (6) a kinetic analysis to determine the change in kinetic properties of the transport during operation.

Benn, G. S. L.↗

A solid state data recorder for spacecraft telemetry applications

A solid state data recorder (SSDR) has been developed which offers a high-reliability alternative to tape recorders in many spacecraft telemetry applications. The storage medium used in this recorder was ferrimagnetic garnet films supporting nonvolatile magnetic bubble domains. The recorder was designed using modular construction consisting of a digital control unit, power supply, and two memory modules. A prototype SSDR has been fabricated which is designed for 100-million bits of storage but was populated with 128 chips for a 13-million bit capacity. Preliminary tests indicate satisfactory operation.

Stermer, R. L., Jr.↗

Documentation for the machine-readable version of the Cordoba Durchmusterung (CD)

The machine-readable version of the catalog, as it is currently being distributed from the Astronomical Data Center, is presented. The complete catalog is contained in the magnetic tape file, and corrections published in all corrigenda were made to the data. The machine version contains 613959 records, but only 613953 stars (six stars were later deleted, but their logical records are retained in the file so that the zone counts are not different from the published catalog).

Warren, W. H., Jr.↗

Documentation for the machine-readable version of the Cape Photographic Durchmusterung (CPD)

The machine-readable version of the catalog, as it is currently being distributed from the Astronomical Data Center, is described. The complete catalog is contained in the magnetic tape file, and corrections published in all errata have been made to the data. The machine version contains 454877 records, but only 454875 stars (two stars were later deleted, but their logical records are retained in the file so that the zone counts are not diiferent from the published catalog).

Warren, W. H., Jr.↗

An imaging vector magnetograph for the next solar maximum

Measurements of the vector magnetic field in the solar atmosphere with high spatial and temporal resolution over a large field of view are critical to understanding the nature and evolution of currents in active regions. Such measurements, when combined with the thermal and nonthermal X-ray images from the upcoming Solar-A mission, will reveal the large-scale relationship between these currents and sites of heating and particle acceleration in flaring coronal magnetic flux tubes. The conceptual design of an imaging vector magnetograph that combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and a rapid digital tape recorder are described. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (4 x 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectra range (5000 to 8000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically dominated chromosphere, as well as effective co-alignment with Solar-A's X-ray images.

Canfield, Richard C.↗

Marshall Space Flight Center head development program

This report summarizes the results of the candidate head evaluation for the new long-life magnetic head per the SOW of Contract No. NAS8-39407, MSFC Head Development Program. The original program plans were to test a candidate head, fabricate a new head, then qualify the new head. These activities were scheduled to be carried out between March 1993 and March 1994. The program was halted after the evaluation of the candidate head by NAS8-39407 Amendment No. 4. MSFC has provided and authorized the use the MARS-2000 SRB QUAL Recorder PN 10400-0677-801 - Serial Number 200004 (Datatape PN 591000 - Serial Number 1004), Reproduce Amplifier Module (RAM) Datatape PN 533040 - Serial Number 2006, associated cables, and magnetic tape on special SRB/DFI tapered reels to Datatape for this program. All the testing that has been done for the candidate head evaluation was done at Datatape's facility in Pasadena,CA. The testing was performed in a Class 100,000 particle counts clean room at ambient temperature, except for the thermal testing which was conducted in a different area at Datatape. The Performance Verification Test Procedure PVT-11004-4 (PVT) and Acceptance Test Procedure ATP-11004-09 (ATP) procedures were used when tests were conducted on the recorder.

Harrer, Jim↗

Laser produces color images from digital data

Color recorder uses two lasers to generate three different-colored beams. Modulators vary intensity of each beam according to information stored on magnetic tape. Together, three beams are sufficient to reproduce virtually any colors on photographic film. Tape synchronizes motion of beam-writing carriage with modulation imposed on beams.

Shulman, A. R.↗

LDEF Interplanetary Dust Experiment (IDE) results

The Interplanetary Dust Experiment (IDE) provided high time resolution detection of microparticle impacts on the Long Duration Exposure Facility satellite. Particles, in the diameter range from 0.2 microns to several hundred microns, were detected impacting on six orthogonal surfaces of the gravity-gradient stabilized LDEF spacecraft. The total sensitive surface area was about one square meter, distributed between LDEF rows 3 (Wake or West), 6 (South), 9 (Ram or East), 12 (North), as well as the Space and Earth ends of LDEF. The time of each impact is known to an accuracy that corresponds to better than one degree in orbital longitude. Because LDEF was gravity-gradient stabilized and magnetically damped, the direction of the normal to each detector panel is precisely known for each impact. The 11 1/2 month tape-recorded data set represents the most extensive record gathered of the number, orbital location, and incidence direction for microparticle impacts in low Earth orbit. Perhaps the most striking result from IDE was the discovery that microparticle impacts, especially on the Ram, South, and North surfaces, were highly episodic. Most such impacts occurred in localized regions of the orbit for dozens or even hundreds of orbits in what we have termed Multiple Orbit Event Sequences (MOES). In addition, more than a dozen intense and short-lived 'spikes' were seen in which impact fluxes exceeded the background by several orders of magnitude. These events were distributed in a highly non-uniform fashion in time and terrestrial longitude and latitude.

Oliver, John P.↗

Magnetic bubble domain memories

Some attractive features of Bubble Domain Memory and its relation to existing technologies are discussed. Two promising applications are block access mass memory and tape recorder replacement. The required chip capabilities for these uses are listed, and the specifications for a block access mass memory designed to fit between core and HPT disk are presented. A feasibility model for a tape recorder replacement is introduced.

Ypma, J. E.↗

Performance of layer wound epoxy-impregnated coils made from a multifilamentary cable of exfoliated YBCO

The performance and reliability of magnets made from second generation (2G), exfoliated, YBCO conductors are highly improved by use of narrow, stacked, multifilamentary cable instead of a single wide tape. This work reports on tests of five mini-coils wound from 2.4 mm wide ExoCable™, which is comprised of eight, stacked, exfoliated, YBCO filaments. The filaments are coupled electrically through a re-flow process, which results in enhanced electrical connectivity between the adjacent layers. The coils were tested at 77 K (up to 500 A) in liquid nitrogen and at 22 K (up to 700 A) in a conduction-cooled mode. The cable carries 500 A critical current at 77 K. A six-layer coil wound from 10.5 m of the cable, the largest coil created in the study, demonstrates a critical current of 280 A at 77 K at 0.4 T magnetic field on the winding. The coils were fully impregnated with Stycast 1266 and Henkel W19 low-viscosity epoxies. Repeated thermal cycling, to 77 and 22 K, does not degrade the coil's performance. The cable AC loss and the coil winding magnetization are compared with the traditional 2G wide tape pancake geometry at 77 K. We observe a five times reduction of the winding magnetization when the 12 mm tape is replaced by a 2.4 mm cable, which is explained by the smaller magnetic moment of the cable winding. The field hysteresis profiles recorded at 22 and 77 K are presented to demonstrate the effect of the operation temperature on the winding magnetization. A finite element analysis of the winding magnetization shows a good agreement between the experimentally measured trapped field value, and the critical state model prediction. Finally, we discuss the stability of an ExoCable™ coil in a conduction-cooled operation.

2G cables↗

Towards a 1000 tracks digital tape recorder

As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

Coutellier, J. M.↗