Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION↗

Statistical analysis of the performance and long-term stability of unquenched LSC standards ( 3 H, 14 C) used for radiochemical measurements

Multiple sets of toluene-based unquenched standards, procured over the last 3 decades, were analyzed to determine their stability over time. A statistical analysis was performed to provide insight into the variability for tSIE and counting efficiency measurements of 3 H and 14 C isotopes. Our data suggests that standards remain viable even 30 years after the manufacturer’s recommended expiration date. Overall, these standards have shown no statistically significant sign of performance degradation. We have proven through statistical analysis that these standards can provide comparable performance over time well past their manufactured expiration date.

LSC standards↗

Influence of irrigation approaches and spatial geolocation on tritium speciation, uptake and depuration

Pine needles and tree cores from a tritium (T) contaminated phytoremediation forest at the Savannah River Site (SRS in Aiken, SC) Mixed Waste Management Facility (MWMF) were measured for total T and T speciation and compared to other locations at the SRS and the surrounding area. Tree core ages ranged from 9 to 14 years old, covering over half of the ~20-year on-going remediation efforts, while pine needles represent more recent time periods of 1-to-2-year increments. Remedial irrigation efforts at the MWMF are found to directly influence the pine needle T concentrations. The T content in the MWMF samples is higher than non-irrigated needle samples from other locations around the SRS. Furthermore, the different forms of organic bound T are preferentially stored in tree core tissue, compared to pine needles where tritiated water dominates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Muon flux measurement at China Jinping Underground Laboratory

China Jinping Underground Laboratory (CJPL) is ideal for studying solar, geo-, and supernova neutrinos. A precise measurement of the cosmic-ray background is essential in proceeding with R&D research for these MeV-scale neutrino experiments. Using a 1-ton prototype detector for the Jinping Neutrino Experiment (JNE), we detected 264 high-energy muon events from a 645.2-day dataset from the first phase of CJPL (CJPL-I), reconstructed their directions, and measured the cosmic-ray muon flux to be $(3.53\pm0.22_{\rm{stat.}}\pm0.07_{\rm{sys.}})\times10^{-10}$ cm $^{-2}$s $^{-1}$. The observed angular distributions indicate the leakage of cosmic-ray muon background and agree with simulation data accounting for Jinping mountain's terrain. A survey of muon fluxes at different laboratory locations, considering both those situated under mountains and those down mine shafts, indicates that the flux at the former is generally a factor of $(4\pm2)$ larger than at the latter, with the same vertical overburden. In conclusion, this study provides a convenient back-of-the-envelope estimation for the muon flux of an underground experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Calorimetry for low-energy electrons using charge and light in liquid argon

Precise calorimetric reconstruction of 5–50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stopping cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT’s well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of σ/E≃9.3%/E⊕1.3% is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N≃30, for example, the energy resolution for electrons below 40 MeV is improved by ≈10%, ≈20%, and ≈40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

11-year cycle solar modulation of cosmic ray intensity inferred from C-14 content variation in dated tree rings

A liquid scintillation-photomultiplier tube counter system was used to measure the Delta-C-14 values of 60 tree rings, dating from 1866 to 1925, that were taken from a white spruce grown in Canada at 68 deg N, 130 deg W. A 10-percent variation is found which is anticorrelated with sunspot numbers, although the amplitude of the variation is 2-3 times higher than expected in trees grown at lower latitudes. A large dip in the data at about 1875 suggests an anomalously large modulation of cosmic ray intensity during the 1867-1878 AD solar cycle, which was the most active of the 19th century.

Fan, C. Y.↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗