Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Heavily Confined PBX 9501 Experiment Report FY2020

Most accidental insults to explosives are invariably thermal in nature—either direct thermal via application of heat or indirect thermal when mechanical energy is converted to heat. The key question is whether the initial thermal insult transitions into a violent explosive response. If the ultimate violence attained is moderate, nearby personnel may be harmed or killed, but Inadvertent Nuclear Detonation (IND) will not occur. However, if the explosive ultimately transitions from deflagration to detonation (DDT) then IND becomes a concern. PBX 9501 is not an insensitive high explosive (IHE). It has been conclusively demonstrated that mechanically and thermally damaged PBX 9501 can readily DDT in heavy confinement. However, it is currently unknown whether pristine explosive—i.e. thermally and mechanically undamaged— is capable of DDT. Three experiments were conducted in order to determine whether very heavily confined pristine PBX 9501 is capable of DDT. All experiments used identical 6-inch diameter spherical charges of PBX 9501 confined in a 350 lb. hardened steel vessel with >2.5-inch thick walls. The first, primary experiment tested pristine PBX 9501 and was thermally ignited at the center of using a laser over optical fiber. Two additional baseline experiments were performed for comparison: the second test was initiated at the center using a detonator; the third test was bulk heated until self-ignition (cookoff). Velocimetry data in combination with hydrocode simulations suggest that a classical detonation wave did not develop in the pristine, thermally ignited PBX 9501. Reaction violence was approximately equivalent—in terms of ultimate energy output—as a full detonation, but the acceleration of metal fragments occurred more slowly than in a detonation-driven scenario.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Producing entangled photon pairs and quantum squeezed states in plasmas

Plasma is capable of mediating the conversion of two pump photons into two different photons through a relativistic four-wave mixing nonlinearity. Spontaneously created photon pairs are emitted at symmetric angles with respect to the colinear pump direction, and the emission rate is largest if they have identical frequency. Thus, two orthogonally polarized pumps can produce polarization-entangled photon pairs through a millimeter-long homogeneous plasma. Here, the noise from Raman scattering can be avoided if the pump detuning differs from twice the plasma frequency. However, pump detuning exactly equal to twice the plasma frequency can significantly enhance the interaction rate, which allows for the production of strong two-mode squeezed states. Remarkably, the amplified noise from Raman scattering are correlated and hence can be suppressed in one of the output quadratures, thereby maintaining the squeezing magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

System and method for all optical electrode interface for bioengineering application

The present disclosure relates to an electro-optical modulator system having a source laser which generates an input optical signal. The input optical signal is received by an electro-optical module. The electro-optical module is implantable into an anatomy and includes a plurality of pixels. Each pixel has associated therewith an electrode and an optical modulator subsystem. The electrode receives electrical signals from the anatomy. The optical modulator subsystem receives the input optical signal and modulates the input optical signal to generate modulated optical output signals in relation to the received electrical signals. A detector subsystem may be used to receive and collect the modulated optical output signals.

Patra, Susant K.↗

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION↗

An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars

The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser-induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so-called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two-element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.

97 MATHEMATICS AND COMPUTING↗

Automatic point Cloud Building Envelope Segmentation (Auto-CuBES) using Machine Learning

Modern retrofit construction practices use 3D point cloud data of the building envelope to obtain the as-built dimensions. However, manual segmentation by a trained professional is required to identify and measure window openings, door openings, and other architectural features, making the use of 3D point clouds labor-intensive. In this study, the Automatic point Cloud Building Envelope Segmentation (Auto-CuBES) algorithm is described, which can significantly reduce the time spent during point cloud segmentation. The Auto-CuBES algorithm inputs a 3D point cloud generated by commonly available surveying equipment and outputs a wire-frame model of the building envelope. Unsupervised machine learning methods were used to identify facades, windows, and doors while minimizing the number of calibration parameters. Additionally, Auto-CuBES generates a heat map of each facade indicating non-planar characteristics that are crucial for the optimization of connections used in overclad envelope retrofits. With a scan resolution of 3 mm, the resulting window dimensions showed a mean absolute error of 4.2 mm compared to manual laser measurements.

Maldonado Puente, Bryan↗

Analysis of Dynamic Behavior of the Target and the Deuterium-Tritium Ice in Magnetic-Field Assisted Implosions

The use of strong magnetic fields to augment the output energy of inertial confinement fusion experiments at the National Ignition Facility is of high interest. It offers the potential of reducing electron thermal conduction and increasing hot-spot alpha heating with little to no change in hohlraum behavior. In these magnetically assisted ignition experiments, the ultimate goal is to add a B-field in the form of a pulse ranging from 25 to 60 T to a high-performing hohlraum implosion several microseconds before impingement of the laser beams. This requires eliminating metallic components in the target and replacing them with electrically nonconducting materials. However, the strong eddy currents generated by the rapidly increasing high B-field, which were calculated to be as high as 2000 K, can heat the hohlraum. Here in this paper, we examine the transient effects of this rapid temperature change on the behavior of the target as well as the fuel layer composed typically of deuterium and tritium. Using simulations and calculations for limiting case scenarios, we find that the effect of the heating is not restrictive toward the performance of the target or the quality of the deuterium-tritium ice.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

A data integration framework of additive manufacturing based on FAIR principles

Abstract Laser-powder bed fusion (L-PBF) is a popular additive manufacturing (AM) process with rich data sets coming from both in situ and ex situ sources. Data derived from multiple measurement modalities in an AM process capture unique features but often have different encoding methods; the challenge of data registration is not directly intuitive. In this work, we address the challenge of data registration between multiple modalities. Large data spaces must be organized in a machine-compatible method to maximize scientific output. FAIR (findable, accessible, interoperable, and reusable) principles are required to overcome challenges associated with data at various scales. FAIRified data enables a standardized format allowing for opportunities to generate automated extraction methods and scalability. We establish a framework that captures and integrates data from a L-PBF study such as radiography and high-speed camera video, linking these data sets cohesively allowing for future exploration. Graphical abstract

36 MATERIALS SCIENCE↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗

Nonlinear post-compression to sub-20 fs using a single-stage multipass cell filled with ambient air

Noble gas-filled multipass cells have proven to be very effective in compressing high-energy, hundreds-of-femtoseconds pulses down to tens of femtoseconds. Molecular gases can be an attractive alternative to noble gases since they provide additional Raman nonlinearities that can be much stronger than the electronic Kerr nonlinearity and can therefore enable more spectral broadening and shorter compressed pulses. Air at atmospheric pressure offers molecular gases in their simplest format, with both easy access and no costs for implementing a gas chamber. Here we demonstrate a single-stage, air-filled multipass cell that spectrally broadens 145- μ J, 185-fs pulses with >90% throughput, with a small fraction of the output compressed to sub-20 fs using a prism-pair compressor. The multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

47 OTHER INSTRUMENTATION↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultranarrow bandwidth pulses from a regeneratively mode-locked fiber laser

We report on the generation of transform-limited nanosecond pulse with an ultranarrow bandwidth from a regeneratively mode-locked erbium-doped fiber laser. A narrow bandwidth fiber Bragg grating is combined with a bulk amplitude electro-optic modulator to shape pulse evolution inside a ring cavity, and regenerative mode locking is applied to produce a stationary shape of pulses in the nanosecond regime (2.05 ns in duration). Spectral characterization via high bandwidth optoelectronic devices shows that optical pulses have an ultranarrow bandwidth of 220 MHz. Numerical simulation reveals that the shape of the narrow spectral filter has a strong effect on the duration and bandwidth of output pulses.

43 PARTICLE ACCELERATORS↗

Modeling of advanced accelerator concepts

Computer modeling is essential to research on Advanced Accelerator Concepts (AAC), as well as to their design and operation. This paper summarizes the current status and future needs of AAC systems and reports on several key aspects of (i) high-performance computing (including performance, portability, scalability, advanced algorithms, scalable I/Os and In-Situ analysis), (ii) the benefits of ecosystems with integrated workflows based on standardized input and output and with integrated frameworks developed as a community, and (iii) sustainability and reliability (including code robustness and usability).

47 OTHER INSTRUMENTATION↗

Effect of processing parameters and build orientation on microstructure and performance of AISI stainless steel 304L made with selective laser melting under different strain rates

Selective laser melting (SLM) process brings diverse potentials on geometry flexibility; therefore, it is more and more widespread to be employed in fabrication metal alloys served for industries. Nonetheless, a material characterization study is desired to carry on for better understanding the correlation among process, structure, microstructure, and performance. In the current study, the SLM fabricated AISI stainless steel 304L was fabricated with different process parameters and built orientations (horizontal, inclined, and vertical. The tensile behavior was evaluated under different strain rates (0.0001 /s, 0.001 /s, 0.01 /s, and 0.1 /s) and compared to the commercial cold-rolled and annealed counterpart. Grain structures, tensile strength, elongation-to-failure, strain rate sensitivity, work hardening, and fractographic analysis were evaluated in terms of the effect of energy density, build orientation, and strain rate. The output indicates the tensile strength increases with increasing strain rates. On the contrary, the elongation-to-failure shows a decreasing trend with strain rates. Tensile properties of specimens built in the horizontal and inclined orientations are more sensitive to strain rates due to the smaller dimension of grain structures. Tensile anisotropy depends on the energy input, where a high energy density could yield a strong build orientation-dependent anisotropy. Hall-Petch relationship is validated to explain the mechanical anisotropy in different built orientations for SLM alloys. The strain hardening exponent and work hardening rate are demonstrated to be positively correlated, and they increase with smaller grain sizes. The fine dimple features indicate the ductile fracture mode regardless of strain rates. The size of the ductile dimples seems to depend on the strain rates and build orientations.

36 MATERIALS SCIENCE↗