Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Fiber-Coupled Erbium-Doped Microsphere Laser

We report a demonstration of an erbium-doped silicate glass microsphere laser with both pumping (at~980nm) and the pickup of laser output (~1550nm) provided by novel angle-polished singel-mode fiber coupler.

microsphere↗

Development of 2.05 µm Fiber Lasers for CO2 DIAL Lidar Measuring Martian CO2 and Pressure

The Decadal Survey by the National Academy of Sciences in the United States and NASA’s Science Mission Directorate (SMD) Science Plan both require global CO 2 observations for the Martian atmospheric pressure, dynamics and chemistry. However, there are significant observational gaps in polar regions and during nighttime for global air pressure and CO 2 on Mars. Therefore, recently we proposed a new concept of Martian differential absorption lidar (DIAL) operating in the 2.05 µm CO 2 absorption band for global, including poles, atmospheric CO 2 and pressure observations day and night [1]. Based on the concept, we are awarded to develop 2.05 µm fiber lasers by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Program. The laser is designed to be an all-fiber master oscillator and power amplifier (MOPA) system with laser output of ~3 mJ at a repetition frequency of 2 kHz. The primary master oscillator (PMO) is locked to the center (2.0504280 µm) of the selected CO 2 absorption line. The frequency of a second MO (SMO) is locked to that of PMO. This SMO frequency is adjustable and switched between the online (2.05044156 µm) and offline (2.05050812 µm) wavelengths. The online wavelength is optimally selected so that the CO 2 absorption optical depth (AOD) is ~1.1 at 3 km and the measurement in the low Martian atmosphere has largest signal-to-noise ratio. The online wavelength can also be adjusted to a line slope location where AOD is larger to observe atmospheric pressure at higher altitudes. We will present more detail about this project and instrument development at the conference.

Zhaoyan Liu↗

Absolute frequency measurement for the emission transitions of molecular iodine in the 982 - 985 nm range

We report high-precision frequency measurements of the separate hyperfine structure (HFS) components of the emission B - X system transitions of {sup 127}I{sub 2} molecules in the 982 - 985 nm range. To resolve the HFS of the emission lines, advantage was taken of the method of three-level laser spectroscopy. The function of exciting radiation was fulfilled by the second harmonic of a cw Nd : YAG laser, and the probe radiation in the 968 - 998 nm range was generated by an external-cavity diode laser. The output Nd : YAG laser frequency was locked to an HFS component of the absorption transition and the probing laser radiation to the emission transition component. When both frequencies were locked to HFS components with a common upper level, the output diode laser frequency was precisely equal to the emission transition frequency. The output frequency of the thus stabilised diode laser was measured with the help of a femtosecond optical frequency synthesiser based on a Ti : sapphire laser. We present the results of the absolute frequency measurements of 20 HFS components belonging to six vibrational - rotational transitions of the B - X system of iodine [R56(32 - 48)a1, P58(32 - 48)a1, P85(33 - 48)a1, R87(33 - 48a1, R88(33 - 48)a10] and all 15 components of the R86(33 - 48) line. The relative measurement uncertainty is equal to 7 Multiplication-Sign 10{sup -10} and is determined by the frequency instability of the diode laser radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

The output beam quality of a Q-switched Nd:glass slab laser

The authors have constructed and tested a flashlamp pumped, Q-switched, Nd:glass zigzag slab laser. The thermally induced optical distortion through the slab is minimized by uniform pumping and cooling and the use of corrective pump shields at the slab ends. The laser spatial output for Q-switched resonators has been measured and modeled. It is shown that a larger aperture planar oscillator has an output divergence many times above the diffraction limit. Operation as a one-dimensional unstable resonator in the wide direction of the slab allows the efficient extraction of energy in a high-quality beam. Near-diffraction-limited laser output of 5 J at 4 Hz is achieved with a resonator that includes an intracavity telescope to correct for residual defocusing in the thin direction of the slab.

Reed, Murray K.↗

Lasing of polycrystalline Cr{sup 2+}:ZnSe pumped by a pulse-periodic Tm:YLF laser

The output characteristics of a laser based on polycrystalline Cr{sup 2+}:ZnSe obtained by diffusion annealing are studied upon pumping by a cw-diode-pumped Q-switched Tm:YLF laser operating at a wavelength of 1.908 {mu}m with a pulse repetition rate of 2 kHz. Efficient pulse-periodic lasing is obtained in the region of 2.32 {mu}m with a total efficiency of {approx}17%, a pulse duration of {approx}45 ns, and an average power of {approx}1 W. (lasers and amplifiers)

36 MATERIALS SCIENCE↗

Tuning the output of a laser

In a general aspect, a laser system includes a laser and a frequency comb generator system. The laser is configured to generate a laser signal, and the frequency comb generator system is configured to generate a frequency comb based on the laser signal. The frequency comb includes frequency comb signals at respective comb frequencies. The laser system also includes a frequency comb dispersion system configured to spatially separate the frequency comb signals onto respective optical channels of the frequency comb dispersion system. The laser system additionally includes a frequency selector system configured to generate a selected frequency signal from the frequency comb signals after separation. The selected frequency signal includes a target separated frequency comb signal. The laser system also includes a frequency shifter configured to alter the selected frequency signal toward a target output frequency of the laser system.

Liu, Chang↗

Coupled Lorenz systems in an optically pumped CH3F laser

The output emission of a short CH3F metallic waveguide laser pumped by an injection-locked CO2 transversely excited atmosphere laser is studied experimentally. The output is found to be extremely unpredictable when lasing occurs in both the excited and ground vibrational states on two separate transitions (496 and 452 microns, respectively). The dynamics and sensitivity to initial conditions are explained in terms of two Lorenz lasers with pump coupled population inversions.

Rabinovich, W. S.↗

Effect of active-region “volume” on the radiative properties of laser heterostructures with radiation output through the substrate

The radiative properties of InGaAs/GaAs/InGaP laser structures with radiation output through the substrate depending on the number of quantum wells in the active region and laser diodes on their basis are investigated. It is established that the presence of six–eight quantum wells in the active region is optimum from the viewpoint of observable values of the threshold current and the output optical power of lasers.

36 MATERIALS SCIENCE↗

Type-II vertical-external-cavity surface-emitting laser with Watt level output powers at 1.2 μ m

Semiconductor laser characteristics based on type-II band-aligned quantum well heterostructures for the emission at 1.2 μm are presented. Ten “W”-quantum wells consisting of GaAs/(GaIn)As/Ga(AsSb)/(GaIn)As/GaAs are arranged as resonant periodic gain in a vertical-external-cavity surface-emitting laser. Its structure is analyzed by X-ray diffraction, photoluminescence, and reflectance measurements. The laser's power curves and spectra are investigated. Output powers at Watt level are achieved, with a maximum output power of 4 W. It is confirmed that laser operation only involves the type-II transition. A blue shift of the material gain is observed while the modal gain exhibits a red shift.

Möller, C.↗

The influence of waveguide doping on the output characteristics of AlGaAs/GaAs lasers

The influence of doping of waveguide layers on the output characteristics of lasers based on AlGaAs/GaAs double separate-confinement heterostructures is analysed. The heterostructures with narrow and broadened waveguides are studied. Samples of laser diode bars with undoped and doped waveguide layers are experimentally fabricated and compared. It is shown that the latter type of structures with a broadened waveguide allows one to increase the output power of the laser diode bars by 10 % – 15 %, all other conditions being equal. (lasers. control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nd : glass rod laser with an output energy of 500 J

The energy of two orthogonally polarised pulses injected into an available multistage amplifier based on neodymium phosphate glass rods was increased from 300 to 500 J (in both pulses). The second output pulse with an energy of 200 J will be used to pump an additional parametric amplifier of a petawatt laser. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acceleration of electrons by a laser pulse at its output onto an optical surface of the vacuum – transparent medium interface. Laser synchrotron

We consider the electron dynamics in the field of an electromagnetic wave produced at the vacuum – transparent medium interface upon reflection from the boundary, close to total internal reflection. The propagation velocity of a constant phase of the electromagnetic wave along the interface can vary from c/n to infinity (c is the speed of light in vacuum, and n is the refractive index of the medium at the interface). In this case, there emerge regions of positive and negative phases of the field with wavelengths, approximately equal to half the wavelength of the original laser beam, which can propagate at a speed close to that of light in vacuum. If a beam of relativistic electrons propagates along the surface, they can gain energy and accelerate, as well as radiate. With closed trajectories of electron motion, a laser synchrotron will be implemented as a result of many acceleration cycles. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Part 1: Classical laser. Part 2: The effect of velocity changing collisions on the output of a gas laser

A classical model for laser action is discussed, in which an active medium consisting of anharmonic oscillators interacts with an electromagnetic field in a resonant cavity. Comparison with the case of a medium consisting of harmonic oscillators shows the significance of nonlinearities for producing self-sustained oscillations in the radiation field. A theoretical model is presented for the pressure dependence of the intensity of a gas laser, in which only velocity-changing collisions with foreign gas atoms are included. A collision model for hard sphere, repulsive interactions was derived. Collision theory was applied to a third-order expansion of the polarization in powers of the cavity electric field (weak signal theory).

Borenstein, M.↗

Output statistics of laser anemometers in sparsely seeded flows

It is noted that until very recently, research on this topic concentrated on the particle arrival statistics and the influence of the optical parameters on them. Little attention has been paid to the influence of subsequent processing on the measurement statistics. There is also controversy over whether the effects of the particle statistics can be measured. It is shown here that some of the confusion derives from a lack of understanding of the experimental parameters that are to be controlled or known. A rigorous framework is presented for examining the measurement statistics of such systems. To provide examples, two problems are then addressed. The first has to do with a sample and hold processor, the second with what is called a saturable processor. The sample and hold processor converts the output to a continuous signal by holding the last reading until a new one is obtained. The saturable system is one where the maximum processable rate is arrived at by the dead time of some unit in the system. At high particle rates, the processed rate is determined through the dead time.

Edwards, R. V.↗

Far-red polyurethane-host solid-state dye laser

The output energy and emission spectrum of a solid-state dye laser using Oxazine 1 in polyurethane as the gain medium have been measured. Under microsecond pumping, efficient lasing has been obtained in the range 700-745 nm. The highest conversion efficiency and output energy achieved are 23% and 127 mJ, respectively. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

An HCN laser with a two-layer anisotropic output mirror

A device for coupling a laser resonator with the external medium consisting of two identical one-dimensional wire gratings positioned in parallel planes with a mutual shift of wires in these planes by half the period is proposed, developed, and experimentally studied. The possibility of using this structure is proven theoretically. The scheme of a laser source used to study the dependence of the output laser power on the distance between the gratings is presented. It is experimentally found that the transmittance of the proposed structure strongly depends both on the distance between the grating planes and on the relative period shift of gratings in these planes. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microsecond gain-switched master oscillator power amplifier (1958 nm) with high pulse energy

An all-fibre master oscillator power amplifier (MOPA) emitting high-energy pulses at 1958 nm is presented. The seed laser is a microsecond gain-switched thulium-doped fibre laser (TDFL) pumped with a commercial 1550-nm pulsed fibre laser. The TDFL operates at a repetition rate f in the range of 10 to 100 kHz. The two-stage thulium-doped fibre amplifier is built to scale the energy of the pulses generated by the seed laser. The maximum output pulse energy higher than 0.5 mJ at 10 kHz is achieved which is comparable with the theoretical maximum extractable pulse energy. The slope efficiency of the second stage amplifier with respect to the pump power is 30.4% at f = 10 kHz. The wavelength of the output pulse laser is centred near 1958 nm at a spectral width of 0.25 nm after amplification. Neither nonlinear effects nor significant amplified spontaneous emission (ASE) is observed in the amplification experiments. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗