Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

FUELS-TOLUENE↗

Design and Modeling of the Off-Axis Parabolic Deformable (OPD) Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Subedi, Hari↗

Design and Modeling of the Off-Axis Parabolic Deformable Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Communication↗

Temperature Control Diagnostics for Sample Environments

In a scientific laboratory setting, standard equipment such as cryocoolers are often used as part of a custom sample environment system designed to regulate temperature over a wide range. The end user may be more concerned with precise sample temperature control than with base temperature. But cryogenic systems tend to be specified mainly in terms of cooling capacity and base temperature. Technical staff at scientific user facilities (and perhaps elsewhere) often wonder how to best specify and evaluate temperature control capabilities. Here we describe test methods and give results obtained at a user facility that operates a large sample environment inventory. Although this inventory includes a wide variety of temperature, pressure, and magnetic field devices, the present work focuses on cryocooler-based systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subject Matter Expert Workshop for the Use of Municipal and Commercial Equipment for Radiological Response and Recovery: National Urban Security Technology Laboratory Workshop Summary Report

This report documents equipment and methods to aid in a wide-area radiological or nuclear response and recovery effort in an urban environment. This report summarizes a workshop held in New York City. The objective of this workshop was to incorporate lessons learned from a prior workshop, close the gaps on some areas that were not discussed in the prior workshop, and include additional subject matter experts from critical infrastructure operations, such as tunnels and bridges, the Port Authority, and mass transit. Various missions were postulated in a hypothetical emergency scenario under five broad support goal categories. Based on the findings and input from a series of such workshops and meetings, we plan to develop “best practices” for use of equipment responding to and recovering from a wide-area radiological incident.

61 RADIATION PROTECTION AND DOSIMETRY↗

Life science payload definition and integration study, task C and D. Volume 3: Appendices

Research equipment requirements were based on the Mini-7 and Mini-30 laboratory concepts defined in Tasks A and B of the intial LSPD contract. Modified versions of these laboratories and the research equipment within them were to be used in three missions of Shuttle/Sortie Module. These were designated (1) the shared 7-day laboratory (a mission with the life sciences laboratory sharing the sortie module with another scientific laboratory), (2) the dedicated 7-day laboratory (full use of the sortie module), and (3) the dedicated 30-day laboratory (full sortie module use with a 30-day mission duration). In defining the research equipment requirements of these laboratories, the equipment was grouped according to its function, and equipment unit data packages were prepared.

Source record↗

Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

25 ENERGY STORAGE↗

Radiochemistry Education and Research Program at the Pennsylvania State University

A new Radiochemistry Education and Research Program was started at the Pennsylvania University, Radiation Science and Engineering Center. The program was initially supported by the Department of Energy, Radiochemistry Education Award Program (REAP). Using REAP funding as leverage we obtained support from the Los Alamos National Laboratory, Department of Homeland Security, Domestic Nuclear Detection Office, various internal funding from PSU and other entities. The PSU radiochemistry program primarily addresses radiochemistry education and secondarily nuclear and radiochemistry research. The education program consists of bolstering our existing radiochemistry and related courses; Nuclear and Radiochemistry, Radiation Detection and Measurement, Radiological Safety and developing new courses, e.g., Laboratory Experiments in Applied Nuclear and Radiochemistry, and Nuclear Methods in Science. A new laboratory has been created with state of the art equipment for the Laboratory Experiments in Applied Nuclear and Radiochemistry course. We also plan to revitalize the nuclear and radiochemistry research programs. We established a state-of-the-art Neutron Activation Analysis Laboratory and a gamma ray spectroscopy laboratory that has 10 stations including state-of-the-art nuclear spectroscopy hardware and software. In addition, we embarked on an expansion plan that included building a new neutron beam hall and neutron beam ports with a cold neutron source. One of the reasons to have a cold neutron source is for the development of a prompt gamma activation analysis facility. A detailed description of PSU radiochemistry education and research program will be given and the future plans will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANL Organization and Facility Management [Slides]

The Laboratory is a DOE Federally Funded Research and Development Center (FFRDC) administered by the NNSA. Therefore, Laboratory facilities and equipment are subject to NNSA oversight. Work at the Laboratory is also subject to many federal laws that apply to the Laboratory’s federal land and property.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Isolated Fast High-Voltage Switching Circuit

Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

Rizzi, Anthony↗

Results from the Operational Testing of the Eaton Smart Grid Capable Electric Vehicle Supply Equipment

The Idaho National Laboratory conducted testing and analysis of the Eaton smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Eaton for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Eaton smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

33 ADVANCED PROPULSION SYSTEMS↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification of Coatings for Launch Facilities and Ground Support Equipment Through the NASA Corrosion Technology Laboratory

Corrosion protection at NASA's Kennedy Space Center is a high priority item. The launch facilities at the Kennedy Space Center are located approximately 1000 feet from the Atlantic Ocean where they are exposed to salt deposits, high humidity, high UV degradation, and acidic exhaust from solid rocket boosters. These assets are constructed from carbon steel, which requires a suitable coating to provide long-term protection to reduce corrosion and its associated costs.

Ground Support Equipment↗

Life sciences payload definition and integration study, task C and D. Volume 1: Management summary

The findings of a study to define the required payloads for conducting life science experiments in space are presented. The primary objectives of the study are: (1) identify research functions to be performed aboard life sciences spacecraft laboratories and necessary equipment, (2) develop conceptual designs of potential payloads, (3) integrate selected laboratory designs with space shuttle configurations, and (4) establish cost analysis of preliminary program planning.

Source record↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

A hardware-in-the-loop approach for laboratory performance verification of flexible building equipment in a typical commercial building

The overall objective of the project is to develop datasets that measure the holistic load flexibility performance of a suite of commonly-used commercial building HVAC and thermal storage equipment using a hardware-in-the-loop test method. The development of the software side of the hardware-in-the-loop flexible load testbed is summarized in this paper.

Chen, Zhelun↗

TU-G-BRD-04: A Round Robin Dosimetry Intercomparison of Gamma Stereotactic Radiosurgery Calibration Protocols

Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalism by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.

60 APPLIED LIFE SCIENCES↗