Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “KERMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-F-T-49: Dosimetry Parameters and TPS Commissioning for the CivaSheet Directional Pd-103 Brachytherapy Source

Purpose: The CivaSheet is a new LDR Pd-103 brachytherapy device offering directional-radiation for preferentially irradiating malignancies with healthy-tissue sparing. Observations are presented on dosimetric characterization, TPS commissioning, and evaluation of the dosesuperposition- principle for summing individual elements comprising a planar CivaSheet Methods: The CivaSheet comprises individual sources (CivaDots, 0.05cm thick and 0.25cm diam.) inside a flexible bioabsorbable substrate with a 0.8cm center-to-center rectangular array. All non-radioactive components were measured to ensure accuracy of manufacturer-provided dimensional information. The Pd spatial distribution was gleaned from radioactive and inert samples, then modeled with the MCNP6 radiation-transport-code. A 6×6 array CivaSheet was modeled to evaluate the dose superposition principle for treatment planning. Air-kerma-strength was estimated using the NIST WAFAC geometry. Absorbed dose was estimated in water with polar sampling covering 0.05≤r≤15cm in 0.05cm increments and 0°≤θ≤180° in 1° increments. These data were entered into VariSeed9.0 and tested for the dose-superposition-principle. Results: The dose-rate-constant was 0.579 cGy/h/U with g(r) determined along the rotational-axis of symmetry (0°) instead of 90°. gP(r) values at 0.1, 0.5, 2, 5, and 10cm were 1.884, 1.344, 0.558, 0.088, and 0.0046. F(r,θ) decreased between 0° and 180° by factors of 270, 23, and 5.1 at 0.1, 1, and 10cm. The highest dose-gradient was at 92°, changing by a factor of 3 within 1° due to Au-foil shielding. TPS commissioning from 0.1≤r≤11cm and 0°≤θ≤180° demonstrated 2% reproducibility of input data except at the high-dose-gradient where interpolations caused 3% differences. Dose superposition of CivaDots replicated a multi-source CivaSheet array within 2% except where another CivaDot was present. Following implantation, the device is not perfectly planar. TPS accuracy utilizing the dose-superposition-principle through geometric repositioning of CivaDots supersedes TPS limitations of intersource shielding effects Conclusion: Dosimetric characterization, source commissioning, and evaluation of the dose-superposition-principle with VariSeed9.0 permits treatment planning for the CivaSheet brachytherapy device. Research supported in part by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

SU-G-201-06: Directional Low-Dose Rate Brachytherapy: Determination of the TG-43 Dose-Rate Constant Analog for a New Pd-103 Source

Purpose: The aim of this work is to determine the TG-43 dose-rate constant analog for a new directional low-dose rate brachytherapy source based on experimental methods and comparison to Monte Carlo simulations. The CivaSheet™ is a new commercially available planar source array comprised of a variable number of discrete directional source elements called “CivaDots”. Given the directional nature and non-conventional design of the source, modifications to the AAPM TG-43 protocol for dosimetry are required. As a result, various parameters of the TG-43 dosimetric formalism have to be adapted to accommodate this source. This work focuses on the dose-rate constant analog determination for a CivaDot. Methods: Dose to water measurements of the CivaDot were performed in a polymethyl methacrylate phantom (20×20×12 cm{sup 3}) using thermoluminescent dosimeters (TLDs) and Gafchromic EBT3 film. The source was placed in the center of the phantom, and nine TLD micro-cubes were irradiated along its central axis at a distance of 1 cm. For the film measurements, the TLDs were substituted by a (3×3) cm{sup 2} EBT3 film. Primary air-kerma strength measurements of the source were performed using a variable-aperture free-air chamber. Finally, the source was modeled using the Monte Carlo N-Particle Transport Code 6. Results: Dose-rate constant analog observed for a total of eight CivaDots using TLDs and five CivaDots using EBT3 film was within ±7.0% and ±2.9% of the Monte Carlo predicted value respectively. The average difference observed was −4.8% and −0.1% with a standard deviation of 1.7% and 2.1% for the TLD and the film measurements respectively, which are both within the comparison uncertainty. Conclusion: A preliminary investigation to determine the doserate constant analog for a CivaDot was conducted successfully with good agreement between experimental and Monte Carlo based methods. This work will aid in the eventual realization of a clinically-viable dosimetric framework for the CivaSheet. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent{sup ®} electronic brachytherapy source (Axxent{sup ®} source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent{sup ®} source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent{sup ®} source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent{sup ®} source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent{sup ®} source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft Inc. (a subsidiary of iCAD). This work was also supported by the Radiological Sciences T32 Training Grant through the University of Wisconsin-Madison Medical Physics department (5T32CA009206-37).

60 APPLIED LIFE SCIENCES↗

SU-G-201-15: Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy

Purpose: Nomogram as a simple QA tool for HDR prostate brachytherapy treatment planning has been developed and validated clinically. Reproducibility including patient-to-patient and physician-to-physician variability was assessed. Methods: The study was performed on HDR prostate implants from physician A (n=34) and B (n=15) using different implant techniques and planning methodologies. A nomogram was implemented as an independent QA of computer-based treatment planning before plan execution. Normalized implant strength (total air kerma strength Sk*t in cGy cm{sup 2} divided by prescribed dose in cGy) was plotted as a function of PTV volume and total V100. A quadratic equation was used to fit the data with R{sup 2} denoting the model predictive power. Results: All plans showed good target coverage while OARs met the dose constraint guidelines. Vastly different implant and planning styles were reflected on conformity index (entire dose matrix V100/PTV volume, physician A implants: 1.27±0.14, physician B: 1.47±0.17) and PTV V150/PTV volume ratio (physician A: 0.34±0.09, physician B: 0.24±0.07). The quadratic model provided a better fit for the curved relationship between normalized implant strength and total V100 (or PTV volume) than a simple linear function. Unlike the normalized implant strength versus PTV volume nomogram which differed between physicians, a unique quadratic model based nomogram (Sk*t)/D=−0.0008V2+0.0542V+1.1185 (R{sup 2}=0.9977) described the dependence of normalized implant strength on total V100 over all the patients from both physicians despite two different implant and planning philosophies. Normalized implant strength - total V100 model also generated less deviant points distorting the smoothed ones with a significantly higher correlation. Conclusion: A simple and universal, excel-based nomogram was created as an independent calculation tool for HDR prostate brachytherapy. Unlike similar attempts, our nomogram is insensitive to implant style and does not rely on reproducing dose calculations using TG-43 formalism, thus making it a truly independent check.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

TU-D-209-04: How Useful Are Indirect Dose Metrics for Estimating Peak Skin Dose in Interventional Cardiology?

Purpose: The purpose of this study was to determine if a relationship between indirect dose metrics and PSD could be established for fluoroscopically-guided interventional cardiology procedures. Methods: PSD were measured directly using XR-RV3 radiochromic film for 94 consecutive fluoroscopically guided interventional cardiology procedures performed at two sites. Procedures were both diagnostic and therapeutic in nature. Radiation dose structured reports (RDSR) were collected for each procedure and used to calculate indirect estimates of PSD which were compared to the measured PSD. Reference air kerma (Ka,r) was also compared to the measured PSD. Pearson’s correlation coefficient was calculated for each metric and metrics were compared to measured PSD using a two-tailed t-test. Data were log transformed prior to statistical analysis. Results: Both Ka,r and the calculated PSD were closely correlated with measured PSD at each sites (Ka,r: 0.92 and 0.86, indirect PSD: 0.91 and 0.88). At one site, neither Ka,r nor indirect PSD was significantly different from the measured PSD (p = 0.22 and p=0.054, respectively), while at the second site both Ka,r and indirect PSD were significantly higher than measured PSD (p<0.0001 and p<0.0001, respectively). In almost all cases, both Ka,r and indirect PSD overestimated the true PSD. Conclusions: The use of a range of gantry angles and table positions, along with variation in procedural imaging requirements, limits the utility of indirect dose metrics for predicting PSD for interventional cardiology procedures. A. Kyle Jones and Alexander S. Pasciak are owners of Fluoroscopic Safety, LLC.

60 APPLIED LIFE SCIENCES↗

Impact of ASTM Standard E722 update on radiation damage metrics

The impact of recent changes to the ASTM Standard E722 is investigated. The methodological changes in the production of the displacement kerma factors for silicon has significant impact for some energy regions of the 1-MeV(Si) equivalent fluence response function. When evaluating the integral over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in an increase in the total 1-MeV(Si) equivalent fluence of 2 7%. Response functions have been produced and are available for users of both the NuGET and MCNP codes.

74 ATOMIC AND MOLECULAR PHYSICS↗

User Manual for MC2-3 Gamma Library Generation

This document presents a detailed description of generating the gamma library for MC 2 -3 which includes delayed gammas and betas based on the 94 gamma energy groups. The updated methodologies associated with heating and gamma calculations are introduced, which account for the self-shielding effect on KERMA factors and perform the gamma transport calculations to condense the gamma data from 94 to 21 groups. For these updates, the PreGAMMA code was developed to prepare NJOY inputs and generate delayed gammas and betas, and the GenGAMMA code was updated to process the outputs of PreGAMMA and NJOY. This document briefly discusses verification results of the new gamma library using the ABTR fuel pin and the EBR-II benchmark problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detailed Description of the Derivation of the Silicon Damage Response Function

This report provides a set of consistent definitions for radiation damage metrics relevant to the modeling of displacement damage in materials. The limitations/approximations built into the various metrics are discussed, as are the intended applications that gave rise to community use of the damage metrics. Numerical tabulations are provided, based on the latest nuclear data, for recommended values of the neutron displacement kerma factor and various NRT-based damage energy metrics in silicon.

36 MATERIALS SCIENCE↗

Relationship between Metrics Used to Represent Displacement Damage in Materials

This report provides a set of consistent definitions for metrics relevant to the modeling of displacement damage in materials. The limitations/approximations built into the various metrics are discussed as is the intended application that gave rise to community use of the metric. Recommended sources for numerical tabulations of the neutron displacement kerma and the charged particle non-ionizing energy loss in some important semiconductor materials are also provided.

36 MATERIALS SCIENCE↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Monte Carlo Analyses of the FOEHN Experiment

The FOEHN critical experiment, which has been carried out at Cadarache (France) in the reactor EOLE in the early 70s, was designed to verify RHF design analyses. This study focuses on the impact of the FOEHN experiment uncertainties on the calculation of the energy deposition. The latter has been obtained by the Monte Carlo codes Serpent and MCNP. In the calculation of the energy deposition, the first code relies on KERMA factors whereas the latter code relies on Q-values. The two Monte Carlo codes share the same geometry and material specifications. In addition to the design and experiment parameters uncertainties, nuclear data also impacts the calculation of the energy deposition. In this study, the MCNP simulations use three different nuclear data library sets: ENDF/B versions VII.0, VII.1, and VIII.0. Finally, the ksens card of MCNP, using perturbation theory, has been used to identify the cross sections and isotopes with largest impact on the effective multiplication factor. By showing that the use of different software and computational methodologies and design parameters uncertainties do not significantly impact the core power distribution, this work demonstrate the appropriateness of the tools and methods employed for the conversion of involute-plate reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The SINBAD evaluation of legacy HPRR experiments [Slides]

The HPRR experiments were evaluated – legacy experiment: a lot of unknowns and high uncertainty. The SINBAD evaluation of legacy HPRR experiments version 1 is soon to be released. It will include neutron fluence and kerma with no shield, steel shield, and Lucite shield. Sample calculation results are mostly good, with notable artifacts due to Bonner sphere unfolding imprecisions that seem complex to be solved. Version 2 will include sulfur pellet activation results with the same shield configurations, and maybe gamma dose and fast results if there is interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Irradiation Assessment of a Lightweight Industrial Robot - Towards Faster, Safer and Sooner Waste Decommissioning - 20317

Robotic systems have been successfully applied in the nuclear industry for several decades as a safe approach to minimize the exposure dose of human operators. As nuclear waste management and decommissioning gathers pace, there is an emerging interest integrating modern off-the-shelf industrial robots in nuclear robotic systems which make use of complex electronics and software to improve functionality over traditional machines. The use of the industrial robots will significantly increase the pace of development of automated waste management systems at a reduced cost, and although these off-the-shelf robots are proven robust in typical industrial environments, performance in radioactive environments is less clear. This paper investigates the performance degradation of a lightweight industrial robot (KUKA iiwa 7 LBR 800) in a controlled radiation field, aiming to simulate conditions in highly radioactive nuclear waste handling facilities. The degradation of the industrial robot's performance is identified while measuring the air kerma dose-tolerance of sensitive components, via a systematic experimental methodology. The experience from this experiment has demonstrated the significant capabilities of industrial robots, which tolerated a large gamma dose of 164 Gy before a system failure. Future tests are planned, aiming to enable faster, safer and sooner waste management and decommissioning using complex robotic systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Code of Radiation Damage by Gamma - Paper 62

In recent years, the study of radiation damage of materials has seen a thrust because of the expectation of the high rate of radiation damage in fusion reactors, accelerator driven sub critical systems and damage of a control system of space vehicles by the high energy neutrons and gamma showers. Embrittlement of reactor vessels, corrosion of steel and swelling of fuel rods are the well known empirical examples of severe radiation damage. It is also realized that damage by high energy gammas is in no way insignificant, and it is equivalent to the damage by the neutrons. Secondly, value addition of certain materials like enhancement of electrical resistance, mechanical strength, color enhancement of precious stones on irradiation by neutrons and gammas and polymerization in the presence of gamma radiation add to the necessity of a Monte Carlo (MC) code of radiation damage in a wide range of energy. The JAIPU code, for the study of radiation damage by neutrons up to 10 MeV energy, incorporates features like development of secondary atomic cascade and PKA energy corrected for the ionization lose and production of Frenkel pair. MC estimation of both the primary and secondary displacements has been compared with the Frenkel pairs calculated using the NRT model. In the present work, JAIPU code is extended for irradiation of materials by high energy gammas. Here cascade generated by the incident gamma produces electrons by way of photo-electric, Compton and pair production until it is absorbed. The recoiled Frenkel pairs produced in electron + atom collision have been considered for the purpose of atomic cascade. Standard cross section libraries for gamma and electron interaction are used while for atom + atom collision we have made use of the IOTA code. In addition, in the code, the lattice structure of the irradiated material is simulated to know the positions of the photon interactions with atoms and the energy of electron it adds an extra feature of the position and size of the voids and the clusters produced on irradiation. The code has the possibility of calculation of 'absorbed radiation dose' and 'KERMA' and the interatomic distances of the displaced atoms. It may be pointed out that the code uses only the MC simulation of the number of displacements unlike several other approaches where the NRT model with PKA energy is used for gross estimation of the number of the displaced atoms. Thus, the code keeps an account of the positions of displaced atoms for the in-depth modification of the irradiated material. 1 MeV gamma seems to damage Fe up to several millimeters of its depth and this is mostly by the recoiled Compton electrons than photo electrons. The code is in the developmental stage and it has the capability of applications in the developing field of Radiology besides the shielding and other studies of radiation damage. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗