Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Flow Characteristics of UHV Nitrogen Arcjet

Flow characteristics in the nozzle of a nitrogen arcjet have been simulated by a model. Electrons, ions, and neutral atoms and molecules are represented as separate species. Dissociation, ionization, and recombination are treated as separate reactions. Thermal non-equilibrium is represented by a two-temperature model. Energy input to plasma from the arc is modeled as a source determined by local current and electrical conductivity. Momentum and energy losses and recombinations at the nozzle wall are included as source/sink determined by fluxes to the wall. The results show essentially frozen gas-phase reactions and thermal nonequilibrium due to Joule heating of electrons and in the expansion part of the nozzle. Wall interactions have strong effects on the results, indicating that they play important roles in the flow due to very high surface area relative to the volume of the plasma. For example, plasma velocity decreases from 6000 m per s without wall interactions to 3000 m per s with modest amount of wall interactions. These results also show reasonable agreement with optical emission measurements, which confirms that the arcjet plasma is far from LTE. The spectra suggest nitrogen dissociation levels of 0.3% - 9%, depending on nitrogen flow rate and arc plasma current, which also determine the relative amounts of excited atomic and molecular nitrogen. Langmuir probe studies of the source show that electron and ion fluxes increase with increasing power, and that the ion energy distribution shifts to lower energies. Typical ion fluxes were on the order of 4E-9 A/cm**2 with a maximum ion kinetic energy of 3.5eV. The median electron energy was 1eV, with a maximum of less than 4eV.

Chang, C. H.↗

Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities

With the need for long periods of extravehicular activities (EVAs) on the Moon or Mars or a near-asteroid, the need for long-performance batteries has increased significantly. The energy requirements for the EVA suit, as well as surface systems such as rovers, have increased significantly due to the number of applications they need to power at the same time. However, even with the best state-of-the-art Li-ion batteries, it is not possible to power the suit or the rovers for the extended period of performance. Carrying a charging system along with the batteries makes it cumbersome and requires a self-contained power source for the charging system that is usually not possible. An innovative method to charge and use the Li-ion batteries for long periods seems to be necessary and hence, with the advent of the Li-ion supercapacitors, a method has been developed to extend the performance period of the Li-ion power system for future exploration applications. The Li-ion supercapacitors have a working voltage range of 3.8 to 2.5 V, and are different from a traditional supercapacitor that typically has a working voltage of 1 V. The innovation is to use this Li-ion supercapacitor to charge Liion battery systems on an as-needed basis. The supercapacitors are charged using solar arrays and have battery systems of low capacity in parallel to be able to charge any one battery system while they provide power to the application. Supercapacitors can safely take up fast charge since the electrochemical process involved is still based on charge separation rather than the intercalation process seen in Li-ion batteries, thus preventing lithium metal deposition on the anodes. The lack of intercalation and eliminating wear of the supercapacitors allows for them to be charged and discharged safely for a few tens of thousands of cycles. The Li-ion supercapacitors can be charged from the solar cells during the day during an extended EVA. The Liion battery used can be half the capacity required for a nominal EVA. The small Li-ion battery can be divided into two parallel modules with independent charging ports that would allow the supercapacitors to charge one battery while the other is providing power to the rover or suit.

Jeevarajan, Judith↗

Separation of 'Uncharged' Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(sub 6), G(sub 8), and G9(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Separation of Uncharged Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(Sub 6), G(sub 8), and G(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Study of fluid mechanical helium argon ion laser

An approach to an argon ion laser based on gasdynamic techniques is presented. Improvement in efficiency and power output are achieved by eliminating high heat rejection problems and plasma confinement of the seal-off conventional lasers. The process of producing population inversion between the same energy levels, as in the conventional argon ion laser, has been divided into two phases by separating each other from the processes of ionization and subsequent excitation. Line drawings and graphs are included to amplify the theoretical presentation.

Source record↗

Aluminum under high pressure: 1 equation of state

A curve of applied pressure P versus lattice constant a is calculated for single crystal aluminum. It results from an application of the method of structural expansions for deriving the energies of simple metals, a method known to give reasonable results for the elastic constants even at second order in the effective electron-ion interaction. The method is taken from Fermi surface analysis . This essentially experimental information is used to verify that the extant face-centered cubic structure remains the preferred crystalline phase up to the highest pressures considered. Arguments are given to suggest that the P versus a curve should have reasonable a priori accuracy, which may be improved if experimental data in the intermediate pressure region can be provided to refine the energy dependent pseudo-potential. At 3 megabars the lattice constant is reduced by only 22%; the ion cores at this pressure are still very well separated.

Friedli, C.↗

Aluminum under high pressure. I - Equation of state

A curve of applied pressure versus lattice constant is calculated for single-crystal aluminum. It results from an application of the method of structural expansions for deriving the energies of simple metals, a method known to give reasonable results for the elastic constants even at second order in the effective electron-ion interaction. The latter is taken from Fermi-surface analysis, and it is verified that the extant face-centered cubic structure remains the preferred crystalline phase up to the highest pressures considered. Arguments are given to suggest that the curve should have reasonable a priori accuracy and can admit possible improvement if experimental data in the intermediate-pressure region can be provided to refine the (in principle) energy-dependent pseudopotential. At three megabars, the lattice constant is reduced by only 22 per cent; the ion cores at this pressure are still very well separated.

Friedli, C.↗

Mass spectrometer beam system for applications in the stratosphere

A special gas inlet system is required for reduction of high ambient pressures to ion source operating pressures for mass spectrometer investigations in the stratosphere for the determination of the abundance of minor constituents. A system has been designed which combines a mass spectrometer and a gas inlet system reducing pressure by differential pumping using high-speed liquid helium pumps and small orifices. The gas particles are formed into a neutral beam with a flag mechanism proceeding into the mass spectrometer ion source where they are ionized for subsequent mass separation. A laboratory model has been tested under conditions simulating stratospheric pressures. It was shown that the process is able to identify gases with abundances below 10 to the -8th. Some of the problems associated with gas analysis of trace constituents have been alleviated, and other applications of the system have been identified, such as pollution control and medicine.

Mauersberger, K.↗

Electrochemical performance and transport properties of a Nafion membrane in a hydrogen-bromine cell environment

The overall energy conversion efficiency of a hydrogen-bromine energy storage system is highly dependent upon the characteristics and performance of the ion-exchange membrane utilized as a half-cell separator. The electrochemical performance and transport properties of a duPont Nafion membrane in an aqueous HBr-Br2 environment were investigated. Membrane conductivity data are presented as a function of HBr concentration and temperature for the determination of ohmic voltage losses across the membrane in an operational cell. Diffusion-controlled bromine permeation rates and permeabilities are presented as functions of solution composition and temperature. Relationships between the degree of membrane hydration and the membrane transport characteristics are discussed. The solution chemistry of an operational hydrogen-bromine cell undergoing charge from 45% HBr to 5% HBr is discussed, and, based upon the experimentally observed bromine permeation behavior, predicted cell coulombic losses due to bromine diffusion through the membrane are presented as a function of the cell state-of-charge.

Baldwin, Richard S.↗

Interplanetary crew exposure estimates for galactic cosmic rays

Using the Langley Research Center galactic cosmic-ray transport computer code and the Computerized Anatomical Man model, initial estimates of interplanetary exposure of astronauts to galactic cosmic rays, during periods of solar minimum activity, are made for a realistic human geometry shielded by various thicknesses of spacecraft aluminum shielding. Conventional dose assessment in terms of total absorbed dose and dose equivalent is made for the skin, ocular lens, and bone marrow. Included in the analyses are separate evaluations of the contributions from the incident primary ions, from subsequent-generation fragmentation products, and from target fragments. In all cases considered, the equivalent sphere approximation yielded conservative overestimates for the actual organ exposures.

Townsend, Lawrence W.↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or a combination of adsorption and ion exchange processes. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission without resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or a combination of adsorption and ion exchange processes. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission without resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery L. Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery L. Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗

Lifetime estimates for sterilizable silver-zinc battery separators

The lifetime of separator membranes currently employed in the electrolyte environment of silver-zinc batteries was estimated at 3 to 5 years. The separator membranes are crosslinked polyethylene film containing grafted poly (potassium acrylate)(PKA), the latter being the hydrophilic agent which promotes electrolyte ion transport. The lifetime was estimated by monitoring the rate of loss of PKA from the separators, caused by chemical attack of the electrolyte, and relating this loss rate to a known relationship between battery performance and PKA concentration in the separators.

Cuddihy, E. F.↗

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗

Performance Evaluation of the T6 Ion Engine

The T6 ion engine is a 22-cm diameter, 4.5-kW Kaufman-type ion thruster produced by QinetiQ, Ltd., and is baselined for the European Space Agency BepiColombo mission to Mercury and is being qualified under ESA sponsorship for the extended range AlphaBus communications satellite platform. The heritage of the T6 includes the T5 ion thruster now successfully operating on the ESA GOCE spacecraft. As a part of the T6 development program, an engineering model thruster was subjected to a suite of performance tests and plume diagnostics at the Jet Propulsion Laboratory. The engine was mounted on a thrust stand and operated over its nominal throttle range of 2.5 to 4.5 kW. In addition to the typical electrical and flow measurements, an E x B mass analyzer, scanning Faraday probe, thrust vector probe, and several near-field probes were utilized. Thrust, beam divergence, double ion content, and thrust vector movement were all measured at four separate throttle points. The engine performance agreed well with published data on this thruster. At full power the T6 produced 143 mN of thrust at a specific impulse of 4120 seconds and an efficiency of 64%; optimization of the neutralizer for lower flow rates increased the specific impulse to 4300 seconds and the efficiency to nearly 66%. Measured beam divergence was less than, and double ion content was greater than, the ring-cusp-design NSTAR thruster that has flown on NASA missions. The measured thrust vector offset depended slightly on throttle level and was found to increase with time as the thruster approached thermal equilibrium.

Snyder, John Steven↗

Recovery and separation of precious metals from space

During the past year a viable procedure centered around centrifugal partition chromatography (CPC), a multistage liquid-liquid partitioning technique for the separation of precious metals (Pt, Pd, Rh, Ir, Os, Ru), was developed. Stable and inexpensive ligands that can be readily recycled to achieve the separations of the precious metals were identified. The separation methods developed so far yield three separate fractions: Pt, Pd, and Rh-Ir. The Rh-Ir pair can be separated in a subsequent run. The total amount of precious metals separated in a single experiment varied from 1 to 50 mg. The factors affecting the efficiencies of these separations were studied. The kinetics of the decomposition of the complex and the ion pair have a major bearing on these efficiencies, with slow kinetics resulting in poor efficiencies. The methods for the improvement of the efficiencies were also investigated. For example, significant improvement in the efficiencies and separation times for Pt and Pd were achieved by the use of chloride gradient in the mobile phase. Two papers were published and talks were presented on our work at the FACSS meeting in Anaheim, Oct. 1991, and at the Pittsburgh Conference in New Orleans, Mar. 1992.

Freiser, H.↗