Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Repowering and Retrofitting of Solar Inverters: A Field Case Study [Slides]

A handful of large-scale photovoltaic (PV) plants have undergone retrofitting and/or repowering of inverters for a variety of reasons, such as rapid product life-cycle innovations with lack of reverse compatibility, original equipment manufacturers (OEMs) exiting the inverter business, weather damage, more lucrative revenue opportunities driven by high contractual offtake price, and so on. Insights has been collected via expert elicitation and relevant staff involved in these retrofitting/repowering at the case study site. Selecting and installing inverters from a different OEM at the commercially operating PV plant provides a unique opportunity to thoroughly document inverter retrofitting/repowering. The case study describes compatibility of mechanical, electrical, communications, and other important aspects. The goal is to provide a public case study that improves the general knowledge of the solar industry about what is involved in repowering/retrofitting a PV plant and how others can best prepare.

14 SOLAR ENERGY↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additivity, Haag duality, and non-invertible symmetries

The algebraic approach to quantum field theory focuses on the properties of local algebras, whereas the study of (possibly non-invertible) global symmetries emphasizes global aspects of the theory and spacetime. We study connections between these two perspectives by examining how either of two core algebraic properties — “additivity” or “Haag duality” — is violated in a 1+1D CFT or lattice model restricted to the symmetric sector of a general global symmetry. For the Verlinde symmetry of a bosonic diagonal RCFT, we find that additivity is violated whenever the symmetry algebra contains an invertible element, while Haag duality is violated whenever it contains a non-invertible element. We find similar phenomena for the Kramers-Wannier and Rep(D 8 ) non-invertible symmetries on spin chains.

Discrete Symmetries↗

Elucidating Compositional Differences in Halide Perovskites for Normal and Inverted Perovskite Solar Cells

Over the recent few years, extensive research efforts have shifted from normal (n-i-p) to inverted (p-i-n) perovskite solar cells (PSCs), owing to their promising efficiency and operational stability, enabled by low-temperature processing. Despite a fundamentally identical operation principle (only structurally inverted), the optimized perovskite compositions for normal and inverted PSCs differ significantly across the literature, suggesting an underlying design principle for perovskite composition. Here, we unveil the role of cesium cation in enhancing interfacial contact between the perovskite layer and the underlying hole-transporting layer (HTL) in inverted PSCs. Comprehensive in situ and device characterization reveal that cesium incorporation promotes the formation of initial nucleation seeds for heterogeneous nucleation at the perovskite/hydrophobic HTL interface, thereby improving their contact. The resulting compositional heterogeneity explains the focus of recent studies on resolving this issue. This study provides mechanistic insight into designing perovskite compositions to further enhance the performance and longevity of PSCs.

Park, Keonwoo↗

Interplay Between Crustal‐Scale Thrusting, High Metamorphic Heating Rates, and the Development of Inverted Thermal‐Metamorphic Gradients: Numerical Models and Examples From the Caledonides of Northern Scotland

Abstract Understanding the processes that produce high prograde metamorphic heating rates and the development of inverted metamorphic sequences in collisional thrust belts remains a fundamental challenge for tectonics and metamorphic petrology. New 2D finite element models of crustal‐scale thrusts with variable slip rates (10, 20, 35, 50 km Myr −1 ) are used to examine how thrust sheet emplacement contributes to these processes. In the models, average prograde heating rates of 31–118 °C Myr −1 are observed in the footwall, with maximum transient heating rates of ∼167 °C Myr −1 occurring at the highest slip rate. Also, thrust sheet emplacement produces an inverted thermal gradient in the model footwall. At slip rates of 10 km Myr −1 , heating magnitudes >200 °C are observed >7 km structurally beneath the thrust plane. At slip rates of 20–50 km Myr −1 , models produce thermal penetration depths of 4–5 km for similar heating magnitudes. Petrologically determined heating rates for thrust footwalls in the Scandian orogenic wedge of northern Scotland mostly yield rates consistent with model results (10–230 °C Myr −1 ). The model‐derived magnitude of inverted thermal gradients is also similar to those indicated in texturally determined deformation temperature transects across the Scandian orogenic wedge (100 °C–180 °C). Combined, these results indicate that high heating rates can be produced by fault slip at typical plate velocities. Additionally, this implies that crustal‐scale thrusts are likely to produce inverted metamorphic sequences in most systems, provided that P‐T conditions during slip allow for metamorphic or recrystallization processes that would preserve evidence for such features.

Thigpen, J. Ryan↗

A classification of invertible phases of bosonic quantum lattice systems in one dimension

We study invertible states of 1D bosonic quantum lattice systems. Here we show that every invertible 1D state is in a trivial phase: after tensoring with some unentangled ancillas, it can be disentangled by a fuzzy analog of a finite-depth quantum circuit. If an invertible state has symmetries, it may be impossible to disentangle it in a way that preserves the symmetries, even after adding unentagled ancillas. We show that in the case of a finite unitary symmetry G , the only obstruction is an index valued in degree-2 cohomology of G . We show that two invertible G -invariant states are in the same phase if and only if their indices coincide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Impedance-Based Modeling and Stability Analysis Approach for Power Oscillations Between Grid-Forming Inverters

This paper presents a new modeling and analysis approach to address the small-signal stability issues among interconnected grid-forming (GFM) inverters. A novel phasor domain “power impedance” model is developed to capture the terminal characteristics of GFM inverters. Based on the developed models, a sum-type impedance stability criterion is proposed to analyze the power oscillations between GFM Inverters. The developed models are validated with EMT simulations and the stability analysis results using the proposed stability criterion can match both EMT simulations and eigenvalue analysis. In addition, the application of the developed model can be extended to the stability analysis of large-scale power system with high penetration of GFM inverters.

Liu, Hanchao↗

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

On Self-Security of Grid-Interactive Smart Inverters

The capability to exchange information with utility operators, aggregators, and nearby smart devices can make a grid-interactive inverter an intelligent cyber-physical device. However, the capability of exchanging information can also put the inverters at the risk of insecure operation. In this paper, possible software manipulations into the inverters are studied to understand their vulnerability to cyberattacks. Moreover, the state-of-the-art system-level and device-level cyber-defense measures are discussed, and advantages and drawbacks of each technique are provided. Studies show that a reference model can be implemented in device-level security to effectively examine incoming setpoints for detecting and preventing malicious or harmful actions. This paper particularly underlines the significance of device-level self-security and its advantages for grid-interactive inverters. Finally, recommendations for future studies are provided.

Gursoy, Mehmetcan↗

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗

Automating the Solar Interconnection Technical Evaluation Process: PREconfiguring and Controlling Inverter SEt-Points (PRECISE)

Utilities are receiving an increasing number of interconnection requests for distributed solar photovoltaic (PV) systems from their customers, requiring a solution to quickly and intelligently perform technical assessments of these requests and to manage these new renewable energy assets. In this paper, we present a stand-alone interconnection tool, PREconfiguring and Controlling Inverter SEt-points (PRECISETM), and how it overcomes the challenges of accelerating technical evaluations and leverages smart inverter functionality to provide local voltage support on an as-needed basis. The paper details the purpose and architecture of PRECISE, including tools, data source requirements, the model-based interconnection evaluation process, and technical results. PRECISE is an integrated software tool that customizes PV inverter settings for utilities by modeling and assessing impacts on local voltages and the need for advanced inverter functions (AIFs) (e.g., volt-VAR and volt-watt). PRECISE maximizes the use of readily available utility data sets to make fast online assessments of incoming PV interconnection requests and makes accept/reject recommendations along with custom settings for AIFs.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Examining the Feasibility of Modeling the Inner Current Loop of a Grid-Following Inverter in the Phasor-Based Solver

Historically, when modeling a grid-following (GFL) inverter in the phasor domain, the fast inner current loop is typically ignored. To achieve a more accurate modeling, the authors have attempted to model the inner current loop in the phasor domain, but experienced significant numerical stability issues. This paper conducts a detailed analysis and provides insight into the feasibility of modeling the inner current loop of a GFL inverter in the phasor domain. It points out that: a) because of the neglection of the inverter filter dynamic, the bandwidth of the inner current loop becomes infinite with typical parameters in the phasor domain, resulting in an inaccurate representation of the actual inner current loop, whose bandwidth is typically between 600 Hz to 2 kHz, and b) the relatively large simulation time step in the phasor simulation causes numerical stability issues when simulating such an inner current loop with an infinite bandwidth. Detailed electromagnetic (EMT) and phasor modeling, and frequency response analysis are performed to explain this phenomenon. The findings of this paper explain why it is inappropriate to model the fast current loop of a GFL inverter in the phasor domain.

Mohiuddin, Sheik Mohammad↗