EPCAPE-PT-LANL Measurements: Scanning Mobility Particle Sizer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Scanning Mobility Particle Sizer (TSI), DMA Classifier Model 3082 + CPC Detector Model 3752. Data Notes: The SMPS dataset is limited due to necessary instrument maintenance and subsequent extensive downtime. Data is only available from October 21 to November 8, 2023. Post November 22, 2023, the NanoScan instrument provided coverage for the latter half of the campaign. To ensure consistency, the data was resampled into uniform size bins ranging from 15 nm to 667 nm. This adjustment was required due to changes in size bins and the maximum diameter that occurred after maintenance and repairs. Multiple Charge Correction applied, Nanoparticle Agglomerate Mobility Analysis not applied, and Diffusion Correction applied. Header: - List [15 nm to 667 nm] middle of the size bin in nanometers: Data reports the concentration particles in this size bin per cubic centimeter, dN/dLog(dp). - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

FPGA-based tracking for the CMS Level-1 trigger using the tracklet algorithm

The high instantaneous luminosities expected following the upgrade of the Large Hadron Collider (LHC) to the High-Luminosity LHC (HL-LHC) pose major experimental challenges for the CMS experiment. A central component to allow efficient operation under these conditions is the reconstruction of charged particle trajectories and their inclusion in the hardware based trigger system. There are many challenges involved in achieving this: a large input data rate of about 20–40 Tb/s; processing a new batch of input data every 25 ns, each consisting of about 15,000 precise position measurements and rough transverse momentum measurements of particles (“stubs”); performing the pattern recognition on these stubs to find the trajectories; and producing the list of trajectory parameters within 4 µs. Here, this paper describes a proposed solution to this problem, specifically, it presents a novel approach to pattern recognition and charged particle trajectory reconstruction using an all-FPGA solution. The results of an end-to-end demonstrator system, based on Xilinx Virtex-7 FPGAs, that meets timing and performance requirements are presented along with a further improved, optimized version of the algorithm together with its corresponding expected performance.

47 OTHER INSTRUMENTATION↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam

We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. Here we studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6–10 μm position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.

47 OTHER INSTRUMENTATION↗

Pre-production results from ATLAS ITk Strip Sensors Quality Assurance Testchip

The production of strip sensors within the framework of the ATLAS Inner Tracker (ITk) development is a process which requires continuous evaluation during the full production period (about 4 years). Such an evaluation is divided into two different parts: Quality Control (QC), which focuses on the final product (the actual sensors) and tries to identify possible defects once the fabrication is completed, and Quality Assurance (QA), which aims to prevent deviations in the manufacturing process and uses specifically-designed test structures. The initial sensor pre-production consists of 5% (1041 sensors) of the total number of sensors expected during production. As part of pre-production, the collaboration has measured key parameters from miniature strip sensors (minis), monitor diodes (MD8), and the ATLAS Testchip, before and after irradiation. In this contribution we focus on the analysis of the results of the MD8 and the Testchip. All parameters have been obtained from the test structures (MD8, bias resistors, interdigitated structures, field oxide capacitors, coupling capacitors, punch-through protection structures and cross-bridge resistors) measured at the different test sites (KEK/Tsukuba, Birmingham, Toronto, Ljubljana, Valencia, Carleton, Prague, CNM-Barcelona). The results are compared to predefined pre- and post-irradiation specifications for each tested parameter.

47 OTHER INSTRUMENTATION↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. Here we, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.

47 OTHER INSTRUMENTATION↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The Advanced Global Atmospheric Gases Experiment (AGAGE) Data

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/datasets/doi: doi:10.15485/1781803), the latest update (Agage_gcmd_gcms.data.2022_01_03.tar.gz) includes 6 months of new data through the end of September 2020. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the AGAGE and affiliated stations (2022R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments. Data from the AGAGE and affiliated stations (total of 9 sites) between August 1993 and March 2021 are provided in “Agage_gcmd_gcms_data_2022_05_26_tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2022_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the AGAGE and affiliated stations (2022R2)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 9 sites) between August 1993 and December 2021 are provided in “Agage_gcmd_gcms_data_2022_11_15.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2022_v2.pdf". Additional information such as the mission and scientific objectives of the ALE/GAGE/AGAGE program can be found on the AGAGE website (https://agage.mit.edu/about/our-mission).

54 ENVIRONMENTAL SCIENCES↗