Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Cloud Hydrology and Albedo Synthesis Mission (CHASM)

This slide presentation reviews the Cloud Hydrology and Albedo Synthesis Mission (CHASM). The interaction of clouds with radiation and the hydrological cycle represents a huge uncertainty in our understanding of climate science and the modeling of climate system feedbacks. Despite the recognized need for a unified treatment of cloud processes, the present global average values of remotely sensed cloud liquid water and theoretically accepted values used for cloud physics and precipitation modeling differ by an order of magnitude. This is due in part to sampling and saturation effects, as well as to threedimensional cloud structure effects. In recent work with the Multiangle Imaging SpectroRadiometer (MISR) on Terra, we have gained new insights as to how the remote sensing approach could be significantly improved using a new instrument that combines passive optical (visible and near infrared) and microwave measurements, both as pushbroom scanners with multiple viewing angles, to the degree that measurements of liquid water path over deep convective clouds over land also become possible. This instrument would also have the ability of measuring height-resolved cloud-tracked winds using a hyper stereo retrieval technique. Deployment into a precessing low earth orbit would be optimal for measuring diurnal cloud activity. We have explored an instrument design concept for this that looks promising if we can establish partnerships that provide launch and bus capabilities.

hydrology↗

Investigation of Magmatic Activities on Early Mars Using Igneous Mineral Chemistry in Gale Crater, Mars

One objective of rover missions is exploring the geological context of the surroundings. Over the years, igneous petrology and sedimentology have been disconnected, the first investigating magmatic processes and volcanic activities, and the second seeking environmental conditions in the past and assessing the habitability of the planet. Although different, one is related to the other: igneous rocks are altered and broken down, leading to the formation of sedimentary rocks, which can in turn be used to back out the nature of their magmatic source. The Curiosity rover that landed in the 3.7 Gyr old impact crater Gale is traveling through sedimentary rocks. About fifty float rocks have been observed, and several of them with ambiguous texture and composition have been classified as igneous or sedimentary depending on studies such as Jake_M. The composition of several unambiguous igneous rocks has been analyzed [4- 6] but their heterogeneity at a larger instrumental (measurement size < 2 cm) scale prevents the measurement of a bulk composition as performed on Earth. An original approach avoiding these two last issues is to consider igneous mineral chemistry analyzed within igneous and sedimentary rocks to assess magmatic processes that could have formed them. Most Curiosity data are used to explore ancient environmental conditions, and a significant number of compositional analyses are under-explored for constraining magmatic activities. We will present how we can make use of sedimentary data for investigating igneous processes in the vicinity of Gale crater. Geological Context: We focus on the first 750 martian days, corresponding to measurements in a coherent lacustrine sedimentary unit called Bradbury, because all sedimentary rocks were sourced from the same watershed and appear to have a consistent source with minimal alteration [2-3]. Igneous detrital minerals including feldspar and pyroxene, are observed in sedimentary rocks. Monte Carlo models showed that minimal cation loss is observed based on the composition of all Bradbury rocks, implying negligible weathering [3]. Although clay minerals are detected in few rocks [7], chemical compositions of rocks can be explained by a mixture of primary igneous minerals [3]. Variation of composition within Bradbury rocks can be explained by mineral sorting and one distinct source component. While a common magmatic source is suggested, Bradbury sediments likely come from several volcanic eruptions from a single magmatic chamber [9- 10]. The occurrence of alkali minerals like sanidine and K-rich rocks throughout Bradbury supports the presence of a potassic component, likely trachytic, while plagioclase and a mafic composition suggest a basaltic component [8-9]. Instruments: Mineral chemistry can be estimated by three instruments onboard Curiosity. The CheMin instrument enables detection of mineral assemblages using X-ray diffraction (XRD). Using Rietveld refinement, each mineral is identified according to their 1D XRD pattern [11]. Note that distinction between pyroxene minerals is challenging with the CheMin instrument due to overlapping peaks on XRD patterns and low angular resolution of the instrument [12]. Then, using least square regression and optimization algorithms based on unit-cell parameters, mineral chemistry has been estimated by [11]. Plagioclase composition has been estimated using the NaAlSi3O8- CaAl2Si2O8 system and alkali feldspar is based on the NaAlSi3O8-KAlSi3O8 system (stars in Fig.1). Two mudstone samples (John Klein and Cumberland) and one sandstone sample (Windjana) were analyzed by CheMin at Yellowknife Bay and Kimberley, respectively. Figure 1. Ternary diagrams of feldspars (top) and pyroxene (bottom) quadrilateral. Stars correspond to CheMin composition and the gray patches to ChemCam composition. The colored dots are the composition of feldspar and pyroxene that crystallized during fractional crystallization at FMQ+1 of a melt extracted at distinct melting degree during the adiabatic ascent of a primitive mantle composition, without any water (left panels) and with 0.5 wt.% of water (right panels) at distinct pressure. The ChemCam instrument enables the analysis of the chemical compositions of rocks at hundreds of micrometer scale (350-550 μm) using laser induced breakdown spectroscopy (LIBS), which may provide the composition of minerals when they are larger than the beam spot (>550 μm) [13]. Within >5000 LIBS points, we performed a typical stoichiometric filtering allowing us to distinguish 56 feldspar and 10 pyroxene mineral compositions (grey patches in Fig. 1). Finally, the Alpha Particle X-ray Spectrometer (APXS) analyzes the composition of rocks with a 1.6 cm diameter spot size. Monte Carlo mass balance modeling allowed [3] to decipher a feldspar range varying between An30 and An40 (Fig. 1). Discussion: Although there could be a more complex history and other ways to form the whole compositional range of igneous minerals analyzed within the Bradbury formation, we are presenting here simple magmatic pathways commonly occurring on Earth using the thermodynamical softwares pMELTS and rhyoliteMELTS [14]. The objective is to find reasonable igneous processes that produce minerals that parallel the compositions of feldspar and pyroxene analyzed by the Curiosity rover. As commonly observed for mid-ocean ridge basalts, the adiabatic ascent of a primitive mantle composition [15] partially melting at 2 GPa has been modeled, followed by the extraction of a liquid at distinct degrees of partial melting, which undergoes fractional crystallization at an oxygen fugacity +1 log unit above the fayalite-magnetite-quartz (FMQ) buffer within the crust (0.02-0.4 GPa) with H2O = 0- 0.5 wt. %. These latter conditions correspond to those recorded within igneous clasts from the Noachian martian breccia NWA 7034 and paired and within Gale igneous rocks (colored dots in Fig. 1) [16-17]. To check the reliability of these 2-step models, we also tested fractional crystallization at similar conditions (FMQ+1; P=0.02-0.4 GPa; H2O = 0-0.5 wt. %) of starting compositions corresponding to that of magmas with distinct melting degrees obtained from isobaric experiments at 2 GPa [18]. Mineral compositions obtained from both models are similar. As shown on Fig. 1, the whole range of observed feldspar compositions cannot be reproduced by fractionation of one magma only. Indeed, while alkali feldspar and Na-plagioclase likely crystallized from fractional crystallization of a low-degree melt (here <15%), plagioclase and pyroxene can only be formed by fractional crystallization of a higher degree melt (here >19%). The corresponding liquid descent lines are broadly in agreement with compositions estimated by ChemCam corresponding to float igneous rocks (Fig. 2) [4-6]. Figure 2. Silica versus alkali content. Lines show the liquid lines of descent from magmas with distinct degrees of melting. Gray patches represents the composition of Gale igneous rocks [4-6]. Trachytic to rhyolitic magmas crystallize alkali feldspar, and andesite to dacite magmas likely form plagioclase. Therefore, at least two starting magmas at distinct melting degrees, which could easily come from a single mantle source, are necessary to explain the whole compositional range of feldspar and pyroxene analyzed within Bradbury rocks. Conclusion: Because rocks from the Bradbury formation are likely originating from the same magmatic source with minimal weathering as supported by several studies using different approaches, igneous mineral chemistry analyzed by CheMin and ChemCam allows us to back out reasonable magmatic pathways that could have crystallized them. Fractional crystallization of at least two starting magmas originating from distinct melting degrees of a single mantle source can explain the whole range of feldspar and pyroxene composition. Both alkaline and sub-alkaline liquids can be produced, with compositions corresponding to those of the igneous rocks analyzed by ChemCam within the Bradbury formation, highlighting the complexity of Mars magmatism.

Payre, V.↗

Status Update on the James Webb Space Telescope Project

The James Webb Space Telescope (JWST) is a large (6.6 m), cold <50 K), infrared (IR)-optimized space observatory that will be launched in approx.2018. The observatory will have four instruments covering 0.6 to 28 micron, including a multi-object spectrograph, two integral field units, and grisms optimized for exoplanets. I will review JWST's key science themes, as well as exciting new ideas from the recent JWST Frontiers Workshop. I will summarize the technical progress and mission status. Recent highlights: All mirrors have been fabricated, polished, and gold-coated; the mirror is expected to be diffraction-limited down to a wavelength of 2 microns. The MIRI instrument just completed its cryogenic testing. STScI has released exposure time calculators and sensitivity charts to enable scientists to start thinking about how to use JWST for their science.

Rigby, Jane R.↗

Instrumentation and Performance Analysis Plans for the HIFiRE Flight 2 Experiment

Supersonic combustion performance of a bi-component gaseous hydrocarbon fuel mixture is one of the primary aspects under investigation in the HIFiRE Flight 2 experiment. In-flight instrumentation and post-test analyses will be two key elements used to determine the combustion performance. Pre-flight computational fluid dynamics (CFD) analyses provide valuable information that can be used to optimize the placement of a constrained set of wall pressure instrumentation in the experiment. The simulations also allow pre-flight assessments of performance sensitivities leading to estimates of overall uncertainty in the determination of combustion efficiency. Based on the pre-flight CFD results, 128 wall pressure sensors have been located throughout the isolator/combustor flowpath to minimize the error in determining the wall pressure force at Mach 8 flight conditions. Also, sensitivity analyses show that mass capture and combustor exit stream thrust are the two primary contributors to uncertainty in combustion efficiency.

Gruber, Mark↗

Numerically Optimized Coronagraph Designs for the Habitable Exoplanet Imaging Mission (HabEx) Concept

The primary science goal of the Habitable Exoplanet Imaging Mission (HabEx), one of four candidate flagship missions under investigation, is to image and spectrally characterize Earth-like exoplanets. It is well known that pupil obscurations degrade coronagraphic performance and complicate coronagraph design, so HabEx is planned to have an off-axis, unobscured primary mirror. We utilize the circular symmetry of the aperture to investigate 1D-radial coronagraph optimization methods that are prohibitively time-consuming or intractable in 2D, such as diffractive pupil remapping and concurrent, multi-plane optimization. We also directly constrain sensitivities to dynamic, low-order Zernike aberrations, which are separable in polar coordinates and can thus be propagated as 1D-radial integrals. The mask technologies in our designs claim heritage from the extensive modeling and testbed experiments performed by the Wide-Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) project. In this paper, we detail our optimization methods and outline future work to complete our design survey.

Balasubramaian, Kunjithapatham↗

Entry Descent and Landing Workshop Proceedings: Commercial Sources for EDL Flight Tests - Volume 1

Commercial Off The Shelf is defined as a Federal Acquisition Regulation (FAR) term for commercial items, including services, available in the commercial marketplace that can be bought and used under government contracts. A need for COTS exists to help in reducing avionics cost associated with applicable missions. In a 2014 a Planetary Science Decadal Survey it was stated that it is imperative that NASA expand its investment in fundamental technology areas. Reduced mass and power requirements for spacecraft and their subsystems. New and improved sensors, instruments, and sampling systems; and Mission and trajectory design and optimization Two goals were written as part of the technology investment: 1. Reducing the cost of planetary missions 2. Improving their scientific capability and reliability...." COTS could certainty aid in reducing cost associated with the instrumentation systems.

Trombetta, Nick↗

Stray Light Suppression in the Goddard IRAM 2-Millimeter Observer (GISMO)

The Goddard-IRAM Superconducting 2 Millimeter Observer (GISMO) is an 8xl6 Transition Edge Sensor (TES) array of bolometers built as a pathfinder for TES detector development efforts at NASA Goddard Space Flight Center. GISMO has been used annually at the Institut de Radioastronomie Millimetrique (IRAM) 30 meter telescope since 2007 under engineering time and was opened in the spring of 2012 to the general astronomical community. The spring deployment provided an opportunity to modify elements of the room temperature optics before moving the instrument to its new permanent position in the telescope receiver cabin. This allowed for the possibility to extend the cryostat, introduce improved cold baffling and thus further optimize the stray light performance for final astronomical use of the instrument, which has been completed and validated. We will demonstrate and discuss several of the methods used to quantify and limit the influence of stray light in the GISMO camera.

Sharp, E. H.↗

Status Update on the James Webb Space Telescope Project

The James Webb Space Telescope (JWST) is a large (6.6 m), cold (<50 K), infrared (IR)-optimized space observatory that will be launched in approx.2018. The observatory will have four instruments covering 0.6 to 28 micron, including a multi-object spectrograph, two integral fie ld units, and grisms optimized for exoplanets. I will review JWST's k ey science themes, as well as exciting new ideas from the recent JWST Frontiers Workshop. I will summarize the technical progress and miss ion status. Recent highlights: All mirrors have been fabricated, polished, and gold-coated; the mirror is expected to be diffraction-limite d down to a wavelength of 2 micron. The MIRI instrument just complete d its cryogenic testing. STScI has released exposure time calculators and sensitivity charts to enable scientists to start thinking about how to use JWST for their science.

Rigby, Jane R.↗

Developing a Novel Platform for Characterizing Thermoelectric Materials for Uncooled Detectors for Land Imaging Applications

Thermal land imaging (imaging at ~8-14 micron optical wavelength) is an essential tool for understanding and managing terrestrial freshwater resources. Current thermal imaging instruments employ low temperature detectors, which require cryocoolers. Consequently, cost-saving reductions in size, weight, and power can be achieved by employing uncooled detectors. One uncooled detector concept, which NASA is pursuing, is a thermopile detector with sub-micron thick doped-Si thermoelectric materials. In order to characterize the thermoelectric properties of the doped silicon, we designed and optimized a novel apparatus. This simple apparatus measures the Seebeck coefficient with thermally isolated stages and LABVIEW automation. We optimized thermal stability using PID tuning and optimized the thermal contact between the thin film samples and stages using electrically conductive springs. Utilizing our apparatus, we measured the Seebeck coefficient of 0.45 micron thick phosphorus-doped single crystal Si samples bonded to alumina substrates. Using these Seebeck coefficient measurements and four-wire electrical resistivity measurements, we determined the relationship between the thermoelectric figure of merit and dopant concentration. These characterization results for doped-Si will guide our thermopile detector design to provide an optimal and competitive detector alternative for future thermal imaging instruments.

Reid, Riley A.↗

Experiments with a fully instrumented split Stirling cryocooler

A practical model that can be used to accurately size and optimally split stirling cryocoolers is discussed. A practical model that could be used to extrapolate existing designs to meet different specifications was developed. However, to do this detailed knowledge of the dynamic operating parameters of this type of cryocooler is required. The first stage is to fully instrument a refrigerator so that various dynamic parameters can be measured. The second stage involves the application of these measurements to the design and optimization of a range of coolers.

Faure, A.↗

(abstract) Pluto Integrated Camera-Spectrometer (PICS): a Low Mass, Low Power Instrument for Planetary Exploration

The concept we describe is an integrated instrument (a Pluto Integrated Camera-Spectrometer -- PICS) that will perform the functions of all three optical instruments required by the Pluto Fast Flyby Mission: the near-IR spectrometer, the camera, and the UV spectrometer. This integrated approach minimizes mass and power use. It also forced us early in the conceptual design to consider integrated observational sequences and integrated power management, thus ensuring compatible duty cycles (i.e., exposure times, readout rates) to meet the composite requirements for data collection, compression, and storage. Based on flight mission experience we believe that this integrated approach will result in substantial cost savings, both in reworking instrument designs during accommodation, as well as in sequence planning and integration. Finally, this integrated payload automatically yields a cohesive mission data set, optimized for correlative analysis. The presentation will provide details of the PICS instrument design and describe the fabrication and testing of the integrated SiC structure and optics at SSG Inc. Final integration and test plans for the prototype will also be described.

Pluto↗

Stratospheric limb radiance simulations for the HCl channel of CLAES

The earthlimb radiance of the HCl detector array of the CLAES instrument is simulated in order to specify and optimize the free spectral range for the etalon used in this spectral region and to select sampling positions which facilitate the recovery of HCl profiles. Considerations entering into the limb radiance computation of each contributing species are discussed. Simulations are then presented for tangent heights of 15 to 5 km for daytime and nighttime conditions, and their significance for HCl retrievals is addressed. The simulation results indicate that the HCl (P2) feature should be observable in the earth limb emission spectrum, and that an etalon with an FSR of 12.6/cm optimally avoids interference from OH emission lines blended with the HCl feature by adjacent transmission peaks.

Mergenthaler, J. L.↗

Infrared astronomy

The decade of 1990's presents an opportunity to address fundamental astrophysical issues through observations at IR wavelengths made possible by technological and scientific advances during the last decade. The major elements of recommended program are: the Space Infrared Telescope Facility (SIRTF), the Stratospheric Observatory For Infrared Astronomy (SOFIA) and the IR Optimized 8-m Telescope (IRO), a detector and instrumentation program, the SubMilliMeter Mission (SMMM), the 2 Microns All Sky Survey (2MASS), a sound infrastructure, and technology development programs. Also presented are: perspective, science opportunities, technical overview, project recommendations, future directions, and infrastructure.

Gillett, Frederick↗

Mid-Infrared Astronomy with the NGST

We present an overview of the science capabilities enabled by a mid-infrared camera/spectrometer on board the NGST. Even without full mid-IR optimization, a mid-infrared (5-30 microns) instrument on the NGST will be orders of magnitude more sensitive than any equivalent ground-based instrument/telescope combination. In the extragalactic arena, the mid-IR region is critical for a complete understanding of the or high-redshift universe, dusty star-formation regions at low and high redshifts, and starburst vs. AGN discrimination. In the local universe, great strides forward can be made using mid-IR imaging, spectroscopy, and coronagraphy of dusty and rocky disks of all ages, from protostellar to remnant debris disks. Near-neighbor detection and characterization can also be greatly advanced by mid-infrared observations.

Serabyn, E.↗

ViDI: Virtual Diagnostics Interface: The Future of Wind Tunnel Testing - Volume 1

The quality of data acquired in a given test facility ultimately resides within the fidelity and implementation of the instrumentation systems. Over the last decade, the emergence of robust optical techniques has vastly expanded the envelope of measurement possibilities. At the same time the capabilities for data processing, data archiving and data visualization required to extract the highest level of knowledge from these global, on and off body measurement techniques have equally expanded. Yet today, while the instrumentation has matured to the production stage, an optimized solution for gaining knowledge from the gigabytes of data acquired per test (or even per test point) is lacking. A technological void has to be filled in order to possess a mechanism for near-real time knowledge extraction during wind tunnel experiments. Under these auspices, the Virtual Diagnostics Interface, or ViDI, was developed.

Fleming, Gary A.↗

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3deg field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

Telescope↗

Sensitivity of Wide Bandwidth Radiometer for Remote Sensing of Ocean Salinity

Passive microwave remote sensing of sea surface salinity from space is currently being done with measurements in the 27 MHz wide spectral window at 1.413 GHz (L-band) protected for passive use. Modern L-band instruments, such as the radiometers on SMOS and Aquarius, have demonstrated the feasibility of monitoring surface salinity from space, and they have also demonstrated the need for better accuracy, especially in cold water. Proposals to improve accuracy have largely involved adding measurement at more frequencies. For example, adding lower frequencies to improve the sensitivity to salinity in cold water and adding higher frequencies to enable simultaneous retrieval of sea surface temperature which is needed in the retrieval of salinity. These strategies involve trade-offs, some obvious such as the effects of interference from anthropogenic sources of radio frequency radiation (RFI) when operating outside the protected band and the loss of spatial resolution at lower frequencies. But, some are more subtle and arise because of the dependence of the retrieval of salinity on other parameters of the ocean surface, in particular, water temperature and roughness (wind speed). The effect of these interdependencies on the potential accuracy of salinity remote sensing in the frequency range 0.3 – 3.0 GHz is examined here to gain insight into the potential for future wide bandwidth instruments for remote sensing of salinity and the optimization of their design. There is benefit including the low frequencies, especially for cold water, but a danger of increased error including frequencies above 1.5 - 2.0 GHz depending on temperature.

Microwave Remote Sensing↗