Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Preliminary Assessment of Step Effects on the BOLT Geometry in Mach 6 Flow

An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.

BOLT↗

A Preliminary Assessment of Step Effects on the BOLT Geometry in Mach 6 Flow

An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.

BOLT↗

Alignment and evaluation of the cryogenic corrected infrared astronomical satellite /IRAS/ telescope

Room temperature alignment and evaluation techniques for the Infrared Astronomical Satellite (IRAS) telescope, which has a primary mirror figured to correct for surface distortions and the 2 K operating temperature are discussed. Interferometric cryogenic testing of the 0.6 m, f/1.5 lightweighted beryllium primary mirror at its intended operating temperature reveals surface distortions that can be modeled with Zernike polynomials. With this model, it becomes possible to derive the 'inverse' of the cryowavefront error (ideal cryo mirror) and to figure the cryo correction into the primary mirror using Perkin-Elmer's Computer Controlled Polisher. It is recognized that during room temperature assembly of the system, misalignment of the secondary mirror can introduce additional unwanted aberrations that may cancel or distort the wavefront errors purposely introduced by the cryo figuring. To avoid this possible degradation and to ensure optimum telescope performance, the system Zernike polynomial coefficients and wavefront maps generated from the in-process alignment interferograms are monitored and compared to Zernike coefficients and wavefront maps for the cryo corrected primary mirror.

Harned, N.↗

A new technique to infer convective rainfall from satellite infrared cloud observations

GLAS-2, a modified version of the GLAS-1 technique developed by Negri et al. (1984) for estimating convective precipitation from GEO-satellite IR data, is introduced and demonstrated on the data set for the Florida Area Cumulus Experiment in 1980. In GLAS-2, rain cells are located by identification of all local blackbody-temperature minima below 253 K in an array of GOES digital data, and rain parameters are assigned on the basis of the one-dimensional cloud model of Adler and Mack (1984). The demonstration results are presented in graphs and tables and compared with those of GLAS-1 and a number of other methods as well as radar and rain-gage measurements. The false-alarm rate for GLAS-2 is found to be 0.54, somewhat better than that of other satellihte methods; further improvements are suggested.

Negri, A. J.↗

Retrieving cloud ice water content and geometrical thickness from microwave and infrared radiometric observations

Techniques are presented and their application illustrated for analysis of remotely sensed data collected with an aircraft carrying a multispectral cloud radiometer and an advanced microwave moisture sounder. The instruments were used on NASA high altitude flights to perform cloud field experiments. Sample IR and microwave brightness temperature data are provided as functions of the ice water path and of the ice water content. Quantitative models are described for deriving the cloud ice (or liquid) water content and the cloud geometric thickness from the radiometric data.

Wu, M.-L. C.↗

A solar chromosphere and spicule model based on far-infrared limb observations

Techniques developed for LTE radiative transfer problems in a rough atmosphere were used to compute a model chromosphere containing spicules consistent with high-resolution solar limb observations from 100 microns to 2.6 mm. The model consists of a smooth, plane-parallel temperature minimum region extending from the photosphere to a height of 1000 km and randomly distributed cylindrical spicules above this height. It is found that the observed limb brightness profiles are well fitted by spicules with electron temperatures on the order of 7000 K.

Braun, D.↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

Radiative transfer models

The purpose of this work was to assist with the development of analytical techniques for the interpretation of infrared observations. We have done the following: (1) helped to develop models for continuum absorption calculations for water vapor in the far infrared spectral region; (2) worked on models for pressure-induced absorption for O2 and N2 and their comparison with available observations; and (3) developed preliminary studies of non-local thermal equilibrium effects in the upper stratosphere and mesosphere for infrared gases. These new techniques were employed for analysis of balloon-borne far infrared data by a group at the Harvard-Smithsonian Center for Astrophysics. The empirical continuum absorption model for water vapor in the far infrared spectral region and the pressure-induced N2 absorption model were found to give satisfactory results in the retrieval of the mixing ratios of a number of stratospheric trace constituents from balloon-borne far infrared observations.

Horwitz, James L.↗

Temperature, Pressure, and Infrared Image Survey of an Axisymmetric Heated Exhaust Plume

The focus of this research is to numerically predict an infrared image of a jet engine exhaust plume, given field variables such as temperature, pressure, and exhaust plume constituents as a function of spatial position within the plume, and to compare this predicted image directly with measured data. This work is motivated by the need to validate computational fluid dynamic (CFD) codes through infrared imaging. The technique of reducing the three-dimensional field variable domain to a two-dimensional infrared image invokes the use of an inverse Monte Carlo ray trace algorithm and an infrared band model for exhaust gases. This report describes an experiment in which the above-mentioned field variables were carefully measured. Results from this experiment, namely tables of measured temperature and pressure data, as well as measured infrared images, are given. The inverse Monte Carlo ray trace technique is described. Finally, experimentally obtained infrared images are directly compared to infrared images predicted from the measured field variables.

Nelson, Edward L.↗

Application of an automatic cloud tracking technique to Meteosat water vapor and infrared observations

The automatic cloud tracking system was applied to METEOSAT 6.7 micrometers water vapor measurements to learn whether the system can track the motions of water vapor patterns. Data for the midlatitudes, subtropics, and tropics were selected from a sequence of METEOSAT pictures for 25 April 1978. Trackable features in the water vapor patterns were identified using a clustering technique and the features were tracked by two different methods. In flat (low contrast) water vapor fields, the automatic motion computations were not reliable, but in areas where the water vapor fields contained small scale structure (such as in the vicinity of active weather phenomena) the computations were successful. Cloud motions were computed using METEOSAT infrared observations (including tropical convective systems and midlatitude jet stream cirrus).

Endlich, R. M.↗

Synchrotron infrared spectroscopy at megabar pressures - Vibrational dynamics of hydrogen to 180 GPa

New techniques for measuring infrared spectra at megabar pressures using synchrotron radiation have been developed and applied to study the Q1(1), Qi(1) + Si(0), and QR(J) vibrational transitions of solid hydrogen to 180 GPa. The frequency difference between the Q1(1) infrared and Raman vibrons increases from 3/cm (zero pressure) to 510/cm (180 GPa), indicating a dramatic increase in intermolecular coupling with pressure. A negative frequency shift is observed for the infrared vibron above 140 GPa. A significant increase in frequency and LO-TO splitting of the lattice phonon is also documented.

Hanfland, M.↗

Infrared Emission Spectroscopy as a Reliability Tool

In this paper we report on a technique based on infrared emission spectroscopy which has been found to be useful for non-contact measurement of the temperature of a hot spot in the gate channel of a GaAs metal/semiconductor field effect transistor (MESFET). The technique was demonstrated on a powered and un-powered GaAs MESFET attaining a spatial resolution of 0.5 microns. A non-destructive submicron-size spot laser beam provided by an HeNe laser excites an extremely small local area of the gate channel of a GaAs MESFET under various operating conditions. Given the state of the experimental test system, we estimate a spatial resolution of about 0.1 microns and a spectral resolution of about 0. I Angstroms. This provides 15 - 100 times finer spatial resolution than can be obtained using the best passive IR systems available. The temperature resolution (less than 0.02 K/micron) of this technique is depend upon the spectrometer used, and that it can be improved further. The information obtained from this technique can be used to estimate device lifetimes for critical applications and for measurement of channel temperature of devices under actual operating conditions. Another potential use of the novel technique can be as a cost-effective prescreening tool for determining the "hot spot" channel temperature of devices under normal operating conditions which can further improve device design, yield enhancement, and reliable operation

Kim, Q.↗

High-resolution infrared spectroscopy of planetary atmospheres

Various techniques for high-resolution infrared spectroscopy of planetary atmospheres are reviewed. Resolving powers of a million are now possible at 1-5 microns with Fourier transform spectrometers and at 10 microns with heterodyne spectrometers. The extension of high-resolution spectroscopy to the far-infrared is currently under development. The role of ground-based high-resolution spectroscopy compared to observations by spacecraft is discussed.

Tokunaga, A. T.↗

Infrared Emission Spectroscopy as a Reliability Tool

In this paper we report on a technique based on infrared emission spectroscopy which has been found to be useful for non-contact measurement of the temperature of a hot spot in the gate channel of a GaAs metal/semiconductor field effect transistor (MESFET).

infrared↗

Remote sensing techniques for support of coastal zone resource management.

Description of remote sensing studies carried out for the purpose of developing and/or demonstrating techniques which can be employed for land use inventory, marsh vegetation classification, and water characteristics surveys. Attention is given to results obtained with (1) photo interpretation techniques and procedures for the development of land use information from high-altitude aircraft and satellite imagery, (2) computer based pattern recognition techniques utilizing multispectral scanner data for marsh vegetation classification, and (3) infrared and microwave techniques for the monitoring and surveying of coastal water temperature and salinity characteristics.

Piland, R. O.↗