Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Immersive Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Immersive Scientific Visualization of Molten-Salt Reactor Waste Characteristics Using Virtual Reality

Immersive visualization is changing how we explore, communicate, and understand complex scientific systems. In nuclear energy, an area in which data are often multidimensional, time-dependent, and difficult to interpret, virtual reality (VR) represents a powerful and intuitive informational medium. This work introduces a VR-based platform that visualizes the post-shutdown behavior and waste management lifecycle of molten-salt reactors (MSRs), a next-generation reactor type with unique operational and safety characteristics. The platform, built in Unity, is streamed on the Meta Quest 3 headset. It transforms high-fidelity simulation data into an interactive, immersive experience. Users can explore time-dependent reactor characteristics such as nuclide decay, which is a key factor for evaluating reactor waste strategies. The datasets were generated using the MOOSE (Multiphysics Object-Oriented Simulation Environment) framework and then processed through ParaView scripting for smooth integration into Unity. From a visualization standpoint, the platform emphasizes spatial storytelling, temporal exploration, and user-centered interaction. Users can navigate 3D reactor geometries, slice through volumetric data, and manipulate time to observe how physical phenomena evolve. Real-scale rendering and embodied interaction make the experience feel tangible. The interface is designed to be accessible, even to those without nuclear or simulation expertise. This lowers the barrier for stakeholders, policymakers, and the general public, while still supporting expert analysis and collaborative decision-making. This work shows how immersive visualization can function as both a scientific tool and a communication interface. By integrating simulation, processing, and visualization into a cohesive workflow, we offer a scalable framework for immersive scientific storytelling. The modular design supports future extensions to other reactor types and lifecycle stages, from shutdown to long-term storage, making the platform adaptable for both research and outreach.

99 - GENERAL AND MISCELLANEOUS↗

Detection of solar wind at synchronous orbit.

During the March 8, 1970 geomagnetic storm, the synchronous spacecraft ATS-5 spent more than 6 hours outside the magnetosphere. At the height of the storm, ATS was fortuitously located near local noon when both the on-board magnetometer and the UCSD plasma detector indicated that the environment had changed from typical magnetosheath (i.e. shocked) to interplanetary character (unshocked). This situation lasted for approximately 3 minutes at 2000 UT before the spacecraft was again immersed in the magnetosheath. Ground-based magnetograms show high activity, but no unusual features at this time. In the magnetosheath the component of magnetic field parallel to the earth axis was about -60 gamma with about plus or minus 30 gamma variations. Outside the magnetosheath, this dropped to an indicated 15 gamma with no large variations.

Deforest, S. E.↗

Modeling time-dependent corrosion fatigue crack propagation in 7000 series aluminum alloys

Stress corrosion cracking and corrosion fatigue experiments were conducted with the susceptible S-L orientation of AA7075-T651, immersed in acidified and inhibited NaCl solution, to provide a basis for incorporating environmental effects into fatigue crack propagation life prediction codes such as NASA FLAGRO. This environment enhances da/dN by five to ten-fold compared to fatigue in moist air. Time-based crack growth rates from quasi-static load experiments are an order of magnitude too small for accurate linear superposition prediction of da/dN for loading frequencies above 0.001 Hz. Alternate methods of establishing da/dt, based on rising-load or ripple-load-enhanced crack tip strain rate, do not increase da/dt and do not improve linear superposition. Corrosion fatigue is characterized by two regimes of frequency dependence; da/dN is proportional to f(exp -1) below 0.001 Hz and to F(exp 0) to F(exp -0.1) for higher frequencies. Da/dN increases mildly both with increasing hold-time at K(sub max) and with increasing rise-time for a range of loading waveforms. The mild time-dependence is due to cycle-time-dependent corrosion fatigue growth. This behavior is identical for S-L nd L-T crack orientations. The frequency response of environmental fatigue in several 7000 series alloys is variable and depends on undefined compositional or microstructural variables. Speculative explanations are based on the effect of Mg on occluded crack chemistry and embritting hydrogen uptake, or on variable hydrogen diffusion in the crack tip process zone. Cracking in the 7075/NaCl system is adequately described for life prediction by linear superposition for prolonged load-cycle periods, and by a time-dependent upper bound relationship between da/dN and delta K for moderate loading times.

Mason, Mark E.↗

A Laboratory Study of the Charging/Discharging Mechanisms of a Dust Particle Exposed to an Electron Beam

The interaction of micron sized particles or "dust particles" with different space and planetary environments has become an important area of research. One particular area of interest is how dust particles interact with plasmas. Studies have shown that charged dust particles immersed in plasmas can alter plasma characteristics, while ions and electrons in plasmas can affect a particle's potential and thereby, its interaction with other particles. The basis for understanding these phenomena is the charging mechanisms of the dust particle, specifically, how the particle's charge and characteristics are affected when exposed to ions and electrons. For example, when electrons collide with a dust particle, secondary electrons can be produced from the surface of a particle and can affect the surrounding plasma.

Venturini, C.C.↗

A Laboratory Study of the Charging/Discharging Mechanisms of a Dust Particle Exposed to an Electron Beam

The interaction of micron sized particles or "dust particles" with different space and planetary environments has become an important area of research. One particular area of interest is how dust particles interact with plasmas. Studies have shown that charged dust particles immersed in plasmas can alter plasma characteristics, while ions and electrons in plasmas can affect a particle's potential and thereby, its interaction with other particles. The basis for understanding these phenomena is the charging mechanisms of the dust particle, specifically, how the particle's charge and characteristics are affected when exposed to ions and electrons. At NASA Marshall Space Flight Center, a laboratory experiment has been developed to study the interaction of dust particles with electrons. Using a unique laboratory technique known as electrodynamic suspension, a single charged particle is suspended in a modified quadrupole trap. Once suspended, the particle is then exposed to an electron beam to study the charging/discharging mechanisms due to collisions of energetic electrons. The change in the particle's charge, approximations of the charging/discharging currents, and the charging/discharging yield are calculated.

Venturini, C. C.↗

Electronic Visualization Laboratory's 50th Anniversary Retrospective: Look to the Future, Build on the Past

September 2023 marks the 50th anniversary of the Electronic Visualization Laboratory (EVL) at University of Illinois Chicago (UIC). EVL's introduction of the CAVE Automatic Virtual Environment in 1992, the first widely replicated, projection-based, walk-in, virtual-reality (VR) system in the world, put EVL at the forefront of collaborative, immersive data exploration and analytics. However, the journey did not begin then. Since its founding in 1973, EVL has been developing tools and techniques for real-time, interactive visualizations—pillars of VR. But EVL's culture is also relevant to its successes, as it has always been an interdisciplinary lab that fosters teamwork, where each person's expertise contributes to the development of the necessary tools, hardware, system software, applications, and human interface models to solve problems. Over the years, as multidisciplinary collaborations evolved and advanced scientific instruments and data resources were distributed globally, the need to access and share data and visualizations while working with colleagues, local and remote, synchronous and asynchronous, also became important fields of study. This paper is a retrospective of EVL's past 50 years that surveys the many networked, immersive, collaborative visualization and VR systems and applications it developed and deployed, as well as lessons learned and future plans.

Johnson, Andrew E.↗

Biomedical support of man in space

The effects of G and/or exercise on cardiopulmonary adjustments to stresses are studied. The control of the cardiopulmonary system is examined using simulated microgravity (recumbency, immersion, lower body positive pressure, and 6-deg head-down tilt) and increased acceleration. It is observed that at rest and during exercise in simulated zero-6 environments, the stroke volume and cardiac output are initially increased and then (after prolonged exposure) return to prezero-G levels. Cardiovascular responses to increased gravity (1, 2, and 3 G) at rest and during exercise are analyzed; a decrease in plasma volume resulting in decreases in stroke volume and cardiac output, and an increase in heart rate are detected.

Pendergast, D. R.↗

Headphone and Head-Mounted Visual Displays for Virtual Environments

A realistic auditory environment can contribute to both the overall subjective sense of presence in a virtual display, and to a quantitative metric predicting human performance. Here, the role of audio in a virtual display and the importance of auditory-visual interaction are examined. Conjectures are proposed regarding the effectiveness of audio compared to visual information for creating a sensation of immersion, the frame of reference within a virtual display, and the compensation of visual fidelity by supplying auditory information. Future areas of research are outlined for improving simulations of virtual visual and acoustic spaces. This paper will describe some of the intersensory phenomena that arise during operator interaction within combined visual and auditory virtual environments. Conjectures regarding audio-visual interaction will be proposed.

Begault, Duran R.↗

Electrical Breakdown of Anodized Structures in a Low Earth Orbital Environmental

A comprehensive set of investigations involving arcing on a negatively biased anodized aluminum plate immersed in a low density argon plasma at low pressures (P(sub O), 7.5 x 10(exp -5) Torr) have been performed. These arcing experiments were designed to simulate electrical breakdown of anodized coatings in a Low Earth Orbital (LEO) environment. When electrical breakdown of an anodized layer occurs, an arc strikes, and there is a sudden flux of electrons accelerated into the ambient plasma. This event is directly followed by ejection of a quasi-neutral plasma cloud consisting of ejected material blown out of the anodized layer. Statistical analysis of plasma cloud expansion velocities have yielded a mean propagation velocity, v = (19.4 +/- 3.5) km/s. As the plasma cloud expands into the ambient plasma, energy in the form of electrical noise is generated. The radiated electromagnetic noise is detected by means of an insulated antenna immersed in the ambient plasma. The purpose of the investigations is (1) to observe and record the electromagnetic radiation spectrum resulting from the arcing process. (2) Make estimates of the travel time of the quasi-neutral plasma cloud based on fluctuations to several Langmuir probes mounted in the ambient plasma. (3) To study induced arcing between two anodized aluminum structures in close proximity.

Galofaro, J. T.↗

Postural Responses Following Space Flight and Ground Based Analogs

With the transition from the Shuttle program to the International Space Station (ISS), the opportunity to fly sensorimotor experiments in a weightless environment has become increasingly more difficult to obtain. As a result, more investigations have turned to ground-based analogs as a way of evaluating an experiment's viability. The two primary analogs available to most investigators are 6deg head down bed rest (HDBR) and dry immersion (DI). For the time being, HDBR investigations have been associated with studies conducted in the United States while the Russians and several other European Union states have concentrated their efforts on using DI as the space flight analog of choice. While either model may be viable for cardiovascular, bone and other system changes, vestibular and sensorimotor investigators have retained serious reservations of either analog's potential to serve as a replacement for a true weightless environment. These reservations have merit, but it is worthwhile to consider that not all changes associated with sensorimotor function during space flight are the result of top-down modifications, but may also be due to the lack, or change, of appropriate support surfaces applying force to the bottom of the feet. To this end we have compared quiet stance postural responses between short duration Space Shuttle flights, long duration ISS flights and HDBR of varying duration. Using these three platforms, representing different modifications of support we investigated postural ataxia using a quiet stance model. Quiet stance was obtained by asking the subjects to stand upright on a force plate, eyes open, arms at the side of the body for three min. From the force plate we obtained average sway velocity in two axes as well as length of line (stabilogram). These parameters were then related to EMG activity recorded from the medial gastrocnemius and lateral tibialis. It is significant to note that postural ataxia measured as quiet stance shows analogous changes between HDBR and space flight. Primary differences across short duration, long duration space flight and HDBR are related to the length of exposure associated with both space flight and HDBR.

Kofman, Igor S.↗

The Virtual Glovebox (VGX): An Immersive Simulation System for Training Astronauts to Perform Glovebox Experiments in Space

The era of the International Space Station (ISS) has finally arrived, providing researchers on Earth a unique opportunity to study long-term effects of weightlessness and the space environment on structures, materials and living systems. Many of the physical, biological and material science experiments planned for ISS will require significant input and expertise from astronauts who must conduct the research, follow complicated assay procedures and collect data and samples in space. Containment is essential for Much of this work, both to protect astronauts from potentially harmful biological, chemical or material elements in the experiments as well as to protect the experiments from contamination by air-born particles In the Space Station environment. When astronauts must open the hardware containing such experiments, glovebox facilities provide the necessary barrier between astronaut and experiment. On Earth, astronauts are laced with the demanding task of preparing for the many glovebox experiments they will perform in space. Only a short time can be devoted to training for each experimental task and gl ovebox research only accounts for a small portion of overall training and mission objectives on any particular ISS mission. The quality of the research also must remain very high, requiring very detailed experience and knowledge of instrumentation, anatomy and specific scientific objectives for those who will conduct the research. This unique set of needs faced by NASA has stemmed the development of a new computer simulation tool, the Virtual Glovebox (VGB), which is designed to provide astronaut crews and support personnel with a means to quickly and accurately prepare and train for glovebox experiments in space.

Smith, Jeffrey D.↗

Electrohydrodynamic Pool Boiling in Reduced Gravity

This research is concerned with studying the effects of applied electric fields on pool boiling in a reduced-gravity environment. Experiments are conducted at the NASA Lewis 2.2 sec Drop tower using a drop rig constructed at UC Davis. In the experiments, a platinum wire is heated while immersed in saturated liquid refrigerants (FC-72 and FC-87), or water, causing vapor formation at the wire surface. Electric fields are applied between the wire surface and an outer screen electrode that surrounds the wire. Preliminary normal-gravity experiments with water have demonstrated that applied electric fields generated by the rig electronics can influence boiling characteristics. Reduced-gravity experiments will be performed in the summer of 1996. The experiments will provide fundamental data on electric field strengths required to disrupt film boiling (for various wire heat generation input rates) in reduced gravity for a cylindrical geometry. The experiments should also shed light on the roles of characteristic bubble generation times and charge relaxation times in determining the effects of electric fields on pool boiling. Normal-gravity comparison experiments will also be performed.

Shaw, Benjamin D.↗

Development of a New Membrane Casting Apparatus for Studying Macrovoid Defects in Low-G

A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.

Lee, Hanyong↗

Using XR for Improving Scientific Discovery With Numerical Weather Models

Our work explores the use of extended reality (XR) to im- prove scientific discovery with numerical weather/climate models that inform Earth science digital twins, specifically the NASA Goddard Earth Observing System (GEOS) global atmospheric model. The overall project is named the Vi- sualization And Lagrangian dynamics Immersive eXtended Reality Toolkit (VALIXR), which has two main areas of focus: (1) enhancing the understanding of and interaction with model output data through advanced visualizations in the XR environment, and (2) the integration of Lagrangian dynamics into the GEOS model, which allows a natural, feature-specific analysis of Earth science phenomena as op- posed to traditional, fixed-point Eulerian dynamics. Here, we report initial work on these focus areas.

Thomas Grubb↗

Kinematic Characteristics of the Posture Corrective Responses After 6 Hours Exposure to Support Withdrawal Environment

Posture disorders are an inevitable consequence of exposure to microgravity . However, the role of different sensorimotor and sensory factors on postural function at different stages of the exposure to microgravity still remains unknown. The results obtained in a 6 hr dry immersion (DI) study where chest pushes served as a pre- and post-immersion perturbation, and DI was used as an analog of microgravity suggest that in addition to vestibular contributions, postural control may be related to a reduction of support loading and consequent decline of the tone of anti-gravitational muscles. Analysis of postural video data in response to chest pushes obtained before and after DI indicate that the structure of corrective responses was modified so that postural perturbations from threshold to moderate pushes showed a significant rise in the amplitude of ankle and knee angular displacement. With push intensity near the submaximal level, equilibrium was maintained by the elimination of excessive degrees of freedom; as manifested by the restriction of the hip joints mobility when coupled with a reduction of the knee and ankle displacement. These results suggest that DI increases the sensitivity of the posture control system by making posture control more rigid reflecting a change of the weight bearing receptors.

Sayenko D.↗

Semiconductor Nanostructures by Scientific Design (Final Technical Report)

We developed and used quantum simulation techniques to predict structural, electronic, optical and thermal properties affecting the scientific design of semiconductor nanostructures. We focused on the study of surfaces and interfaces at the nanoscale, in particular embedding and solvation of semiconductor nanoparticles, and provided a microscopic description of nanostructured materials in realistic environments, directly comparable with experimental conditions. We addressed three major problems: (i) the design of realistic structural models of integrated nanostructures, e.g. quantum dots embedded in solid matrices and nanostructures immersed in fluids; (ii) the development of efficient and accurate calculations to describe the excited state properties of nanostructures, beyond standard Density Functional Theory, so as to understand and predict electronic properties involved in renewable energy applications, for example solar conversion devices. In particular we developed and used methods based on a many body perturbation theory. (iii) the development of calculations of heat transport properties of nanostructured materials, for thermoelectric applications, including predictive calculations of thermal and electrical conductivity and of Seebeck coefficients. Specifically, we developed and used methods based on the Boltzmann transport equation and molecular dynamics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Discrete liquid/vapor detectors for use in liquid helium

Simple devices have been constructed and tested which can discriminate between liquid helium and its vapor. The devices are 0.25-mm doped silicon cubes suspended from 0.05-mm-diameter stainless steel and manganin wires. A small current is passed through the device heating it and lowering its resistance. The degree of self-heating is dependent on whether the device is immersed in liquid or is surrounded by vapor. The voltage across the device then indicates the presence of liquid or vapor. The devices are meant to operate in the milligravity environment of space. Tests simulating thick superfluid films which would be present in this case indicate less than 0.3 milliwatt per detector is sufficient to boil away these thick films. The detector response time under these conditions is less than 50 milliseconds.

Dipirro, M. J.↗