Ground-Truth Prediction to Accelerate Soft-Error Impact Analysis for Iterative Methods

Understanding the impact of soft errors on applications can be expensive. Often, it requires an extensive error injection campaign involving numerous runs of the full application in the presence of errors. In this paper, we present a novel approach to arriving at the ground truth--the true impact of an error on the final output--for iterative methods by observing a small number of iterations to learn deviations between normal and error-impacted execution. We develop a machine learning based predictor for three iterative methods to generate ground-truth results without running them to completion for every error injected. We demonstrate that this approach achieves greater accuracy than alternative prediction strategies, including three existing soft error detection strategies. We demonstrate the effectiveness of the ground truth prediction model in evaluating vulnerability and the effectiveness of soft error detection strategies in the context of iterative methods.

iterative methods, failure prediction, Soft error ↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of a cone-beam CT image via forward iterative projection matching

Purpose: To demonstrate the feasibility of reconstructing a cone-beam CT (CBCT) image by deformably altering a prior fan-beam CT (FBCT) image such that it matches the anatomy portrayed in the CBCT projection data set. Methods: A prior FBCT image of the patient is assumed to be available as a source image. A CBCT projection data set is obtained and used as a target image set. A parametrized deformation model is applied to the source FBCT image, digitally reconstructed radiographs (DRRs) that emulate the CBCT projection image geometry are calculated and compared to the target CBCT projection data, and the deformation model parameters are adjusted iteratively until the DRRs optimally match the CBCT projection data set. The resulting deformed FBCT image is hypothesized to be an accurate representation of the patient's anatomy imaged by the CBCT system. The process is demonstrated via numerical simulation. A known deformation is applied to a prior FBCT image and used to create a synthetic set of CBCT target projections. The iterative projection matching process is then applied to reconstruct the deformation represented in the synthetic target projections; the reconstructed deformation is then compared to the known deformation. The sensitivity of the process to the number of projections and the DRR/CBCT projection mismatch is explored by systematically adding noise to and perturbing the contrast of the target projections relative to the iterated source DRRs and by reducing the number of projections. Results: When there is no noise or contrast mismatch in the CBCT projection images, a set of 64 projections allows the known deformed CT image to be reconstructed to within a nRMS error of 1% and the known deformation to within a nRMS error of 7%. A CT image nRMS error of less than 4% is maintained at noise levels up to 3% of the mean projection intensity, at which the deformation error is 13%. At 1% noise level, the number of projections can be reduced to 8 while maintaining CT image and deformation errors of less than 4% and 13%, respectively. The method is sensitive to contrast mismatch between the simulated projections and the target projections when the soft-tissue contrast in the projections is low. Conclusions: By using prior knowledge available in a FBCT image, the authors show that a CBCT image can be iteratively reconstructed from a comparatively small number of projection images, thus saving acquisition time and reducing imaging dose. This will enable more frequent daily imaging during radiation therapy. Because the process preserves the CT numbers of the FBCT image, the resulting 3D image intensities will be more accurate than a CBCT image reconstructed via conventional backprojection methods. Reconstruction errors are insensitive to noise at levels beyond what would typically be found in CBCT projection data, but are sensitive to contrast mismatch errors between the CBCT projection data and the DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-EF-207-07: Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)

Purpose: Conventional dual energy CT (DECT) reconstructs CT and basis material images from two full-size projection datasets with different energy spectra. To relax the data requirement, we propose an iterative DECT reconstruction algorithm using one full scan and a second sparse-view scan by utilizing redundant structural information of the same object acquired at two different energies. Methods: We first reconstruct a full-scan CT image using filtered-backprojection (FBP) algorithm. The material similarities of each pixel with other pixels are calculated by an exponential function about pixel value differences. We assume that the material similarities of pixels remains in the second CT scan, although pixel values may vary. An iterative method is designed to reconstruct the second CT image from reduced projections. Under the data fidelity constraint, the algorithm minimizes the L2 norm of the difference between pixel value and its estimation, which is the average of other pixel values weighted by their similarities. The proposed algorithm, referred to as structure preserving iterative reconstruction (SPIR), is evaluated on physical phantoms. Results: On the Catphan600 phantom, SPIR-based DECT method with a second 10-view scan reduces the noise standard deviation of a full-scan FBP CT reconstruction by a factor of 4 with well-maintained spatial resolution, while iterative reconstruction using total-variation regularization (TVR) degrades the spatial resolution at the same noise level. The proposed method achieves less than 1% measurement difference on electron density map compared with the conventional two-full-scan DECT. On an anthropomorphic pediatric phantom, our method successfully reconstructs the complicated vertebra structures and decomposes bone and soft tissue. Conclusion: We develop an effective method to reduce the number of views and therefore data acquisition in DECT. We show that SPIR-based DECT using one full scan and a second 10-view scan can provide high-quality DECT images and accurate electron density maps as conventional two-full-scan DECT.

60 APPLIED LIFE SCIENCES↗

Calibration of ITER Instant Power Neutron Monitors: Recommended Scenario of Experiments at the Reactor

Instant power is a key parameter of the ITER. Its monitoring with an accuracy of a few percent is an urgent and challenging aspect of neutron diagnostics. In a series of works published in Problems of Atomic Science and Technology, Series: Thermonuclear Fusion under a common title, the step-by-step neutronics analysis was given to substantiate a calibration technique for the DT and DD modes of the ITER. A Gauss quadrature scheme, optimal for processing “expensive” experiments, is used for numerical integration of {sup 235}U and {sup 238}U detector responses to the point sources of 14-MeV neutrons. This approach allows controlling the integration accuracy in relation to the number of coordinate mesh points and thus minimizing the number of irradiations at the given uncertainty of the full monitor response. In the previous works, responses of the divertor and blanket monitors to the isotropic point sources of DT and DD neutrons in the plasma profile and to the models of real sources were calculated within the ITER model using the MCNP code. The neutronics analyses have allowed formulating the basic principles of calibration that are optimal for having the maximum accuracy at the minimum duration of in situ experiments at the reactor. In this work, scenarios of the preliminary and basic experimental ITER runs are suggested on the basis of those principles. It is proposed to calibrate the monitors only with DT neutrons and use correction factors to the DT mode calibration for the DD mode. It is reasonable to perform full calibration only with {sup 235}U chambers and calibrate {sup 238}U chambers by responses of the {sup 235}U chambers during reactor operation (cross-calibration). The divertor monitor can be calibrated using both direct measurement of responses at the Gauss positions of a point source and simplified techniques based on the concepts of equivalent ring sources and inverse response distributions, which will considerably reduce the amount of measurements. It is shown that the monitor based on the average responses of the horizontal and vertical neutron chambers remains spatially stable as the source moves and can be used in addition to the staff monitor at neutron fluxes in the detectors four orders of magnitude lower than on the first wall, where staff detectors are located. Owing to low background, detectors of neutron chambers do not need calibration in the reactor because it is actually determination of the absolute detector efficiency for 14-MeV neutrons, which is a routine out-of-reactor procedure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, Manufacture, and Experimental Serviceability Validation of ITER Blanket Components

In 2014, the Russian Federation and the ITER International Organization signed two Procurement Arrangements (PAs) for ITER blanket components: 1.6.P1ARF.01 “Blanket First Wall” of February 14, 2014, and 1.6.P3.RF.01 “Blanket Module Connections” of December 19, 2014. The first PA stipulates development, manufacture, testing, and delivery to the ITER site of 179 Enhanced Heat Flux (EHF) First Wall (FW) Panels intended for withstanding the heat flux from the plasma up to 4.7MW/m{sup 2}. Two Russian institutions, NIIEFA (Efremov Institute) and NIKIET, are responsible for the implementation of this PA. NIIEFA manufactures plasma-facing components (PFCs) of the EHF FW panels and performs the final assembly and testing of the panels, and NIKIET manufactures FW beam structures, load-bearing structures of PFCs, and all elements of the panel attachment system. As for the second PA, NIKIET is the sole official supplier of flexible blanket supports, electrical insulation key pads (EIKPs), and blanket module/vacuum vessel electrical connectors. Joint activities of NIKIET and NIIEFA for implementing PA 1.6.P1ARF.01 are briefly described, and information on implementation of PA 1.6.P3.RF.01 is given. Results of the engineering design and research efforts in the scope of the above PAs in 2015–2016 are reported, and results of developing the technology for manufacturing ITER blanket components are presented.

42 ENGINEERING↗

Hydrogen lines in the infrared region and spectral background for the thomson scattering diagnostics of the iter divertor plasma

Calculations are made of the plasma spectral background, which is important for the Thomson scattering diagnostics in the ITER divertor. Theoretical grounds have been elaborated for computing the hydrogen spectral line shapes in the infrared spectral region for a divertor plasma in ITER. The shape of the P-7 Paschen line (transition n = 7 {yields} n = 3) located near the laser scattering signal has been calculated for various lines of sight in the ITER divertor. Contributions from different mechanisms of broadening the P-7 line have been examined. The spectral intensities of bremsstrahlung and photorecombination continuum have been calculated. All calculations use data on the spatial distribution of temperatures and densities of all species of plasma particles computed with the SOLPS4.3 code for basic operation regimes of the ITER divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report on ITER Task Agreement 81-18

During 2007, the US International Thermonuclear Experimental Reactor (ITER) Project Office (USIPO) entered into a Task Agreement (TA) with the ITER International Organization (IO) to conduct Research and Development activity and/or Design activity in the area of Safety Analyses. There were four tasks within this TA, which were to provide the ITER IO with: 1) Quality Assurance (QA) documentation for the MELCOR 1.8.2 Fusion code, 2) a pedigreed version of MELCOR 1.8.2, 3) assistance in MELCOR input deck development and accident analyses, and 4) support and assistance in the operation of the MELCOR 1.8.2. This report, which is the final report for this agreement, documents the completion of the work scope under this ITER TA, designated as TA 81-18.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictive Simulations of ITER Including Neutral Beam Driven Toroidal Rotation

Predictive simulations of ITER [R. Aymar et al., Plasma Phys. Control. Fusion 44, 519 2002] discharges are carried out for the 15 MA high confinement mode (H-mode) scenario using PTRANSP, the predictive version of the TRANSP code. The thermal and toroidal momentum transport equations are evolved using turbulent and neoclassical transport models. A predictive model is used to compute the temperature and width of the H-mode pedestal. The ITER simulations are carried out for neutral beam injection (NBI) heated plasmas, for ion cyclotron resonant frequency (ICRF) heated plasmas, and for plasmas heated with a mix of NBI and ICRF. It is shown that neutral beam injection drives toroidal rotation that improves the confinement and fusion power production in ITER. The scaling of fusion power with respect to the input power and to the pedestal temperature is studied. It is observed that, in simulations carried out using the momentum transport diffusivity computed using the GLF23 model [R.Waltz et al., Phys. Plasmas 4, 2482 (1997)], the fusion power increases with increasing injected beam power and central rotation frequency. It is found that the ITER target fusion power of 500 MW is produced with 20 MW of NBI power when the pedesta temperature is 3.5 keV. 2008 American Institute of Physics. [DOI: 10.1063/1.2931037]

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements in Iterative Convergence of FUN3D Solutions

This paper presents a hierarchical adaptive nonlinear iteration method (HANIM) implemented in the NASA computational fluid dynamics code, FUN3D, to improve robustness and computational efficiency. In contrast to the legacy FUN3D iterative solver that relies on an approximate Jacobian, a simple multicolor Gauss-Seidel point-implicit iteration scheme, and linear Courant-Friedrichs-Lewy number (CFL) ramping, HANIM is based upon a hierarchy of modules including preconditioner, generalized conjugate residual, realizability check, nonlinear control, and CFL adaption modules. HANIM performance is systematically compared with the performance of the legacy solver of FUN3D and a baseline solver based on a preconditioner alone. Iterative solutions are compared for three benchmark cases: a subsonic separated flow around a hemisphere cylinder, a supersonic flow through a long duct, and a subsonic flow over the NASA wing-fuselage juncture model. Two Reynolds-averaged Navier-Stokes turbulence models are used in these computations, namely, the negative variant of the linear one-equation Spalart-Allmaras model and its nonlinear extension based on quadratic constitutive relations.

CFD↗

Fast Acting Eddy Current Driven Valve for Massive Gas Injection on ITER

Tokamak plasma disruptions present a significant challenge to ITER as they can result in intense heat flux, large forces from halo and eddy currents, and potential first-wall damage from the generation of multi-MeV runaway electrons. Massive gas injection (MGI) of high Z material using fast acting valves is being explored on existing tokamaks and is planned for ITER as a method to evenly distribute the thermal load of the plasma to prevent melting, control the rate of the current decay to minimize mechanical loads, and to suppress the generation of runaway electrons. A fast acting valve and accompanying power supply have been designed and first test articles produced to meet the requirements for a disruption mitigation system on ITER. The test valve incorporates a flyer plate actuator similar to designs deployed on TEXTOR, ASDEX upgrade, and JET [1 3] of a size useful for ITER with special considerations to mitigate the high mechanical forces developed during actuation due to high background magnetic fields. The valve includes a tip design and all-metal valve stem sealing for compatibility with tritium and high neutron and gamma fluxes.

Fast Acting Eddy current↗

The Roles and Developments needed for Diagnostics in the ITER Fusion Device

Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasma current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER Port Interspace Pressure Calculations

The ITER ('the way' in Latin) project in Cadarache, France, will operate the largest tokamak ever built to demonstrate the physical and technical feasibility of nuclear fusion as an energy source. The ITER vacuum vessel is equipped with 50 access ports. Each port has an opening in the bio-shield that communicates with a dedicated port cell. During tokamak operation, the bio-shield opening must be closed with a concrete plug to shield the radiation coming from the plasma. This port plug separates the port cell into a port interspace (between vacuum vessel closure lid and port plug) on the inner side and a port cell on the outer side. This paper presents calculations of pressures and temperatures in the ITER port interspace after a double-ended guillotine break (DEGB) of a pipe in the tokamak cooling water system (TCWS). It is assumed that the DEGB occurs during the worst possible conditions-during water baking operation, with water at 523 K (250 deg. C) and 4.4 MPa. These conditions are more severe than during normal tokamak operation with the water at 398 K (125 deg. C) and 2 MPa. Two computer codes are employed in these calculations: RELAP5-3D Version 4.2.1 to calculate blowdown releases from the pipe break, and MELCOR, Version 1.8.6 to calculate pressures and temperatures in the port interspace. A sensitivity study has been performed to optimize the maximum peak pressure in the port interspace volume of ITER. The optimum case was for a labyrinth area (FL131) of 0.5 m{sup 2} and a relief panel (FL135) kept open after the first cycle. This case keeps the pressure in the port interspace under 150 kPa and the temperatures under 385 K. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near Surface Disposal Facility Iterative Assessment - 19199

Canadian Nuclear Laboratories (CNL) is proposing the construction of a Near Surface Disposal Facility (NSDF) on the Chalk River site, in order to dispose of legacy low level waste and anticipated building debris from future decommissioning. A Performance Assessment is being conducted, using an iterative process, to assess the short and long term effects of this facility. Three iterations have already been completed, each building on the last, and a further iteration is underway to improve on the current results. This paper discusses the iterative process taken in these assessments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutronics for diagnostics in ITER - Paper 121

ITER, currently under construction in the south of France, will be the first tokamak producing large amounts of neutrons and having a fusion energy gain factor, which is the ratio between the fusion power produced and the input power necessary to maintain the plasma, greater than 10. ITER will be able to generate 500 MW of fusion power, from which 400 MW are 14.1 MeV neutrons from the Deuterium-Tritium fusion reactions in the thermonuclear plasma. For such nuclear machine neutronics are of paramount importance, being a design driver for many of its components, in particular its Ports and its numerous Diagnostics, for which the influence of neutronics is especially important in three main areas: - Shielding: there is a strong need to provide nuclear shielding to areas where human access is foreseen for maintenance. Also, to minimize any impact in the primary shielding components (blankets) in order to avoid significant increases in the heating of the Vacuum Vessel (VV) and Superconductive Coils. - Sensors and diagnostic components: most of the diagnostics have sensitive components that need to be shielded against radiation to survive. Efficient shielding is not always possible, and the radiation levels are usually the decisive factor for selecting the most appropriate component. - Neutron measurements: a large set of neutron diagnostics will be implemented to measure the neutron production and its emissivity profile. Although the scale and performance of ITER will not be very far from a commercial reactor, it is ultimately an experiment to improve the understanding of reactor-grade tokamak plasmas and their effect on plasma facing components. To accomplish this task, large efforts are being dedicated to design over 45 different diagnostics systems. This paper gives an overview of the main activities related to neutronics within the ITER Diagnostics Division. They include the neutron streaming problems in the Ports and the common neutronics issues of the diagnostics housed inside them, as well as the challenges of the in vessel diagnostics. Also the special calculations needed for the neutron diagnostics. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Paradigm Changes in High Temperature Plasma Physics Research and Implications for ITER

Significant high temperature plasma research in both the magnetic and inertial confinement regimes led to the official launching of the International Thermonuclear Experimental Reactor (ITER) project which is aimed at challenging controlled fusion power for human kind. In particular, such an endeavor originated from the fruitful research outcomes from the world wide magnetic confinement devices (primarily based on the Tokamak approach) mainly in advanced countries (US, EU, and Japan). In recent years, all new steady state capable Tokamak devices are operated and/or constructed in Asian countries and incidentally, the majority of the ITER consortium consists of Asian countries. This provides an opportunity to revisit the unresolved essential physics issues and/or extend the understanding of the transient physics to the required steady state operation so that ITER can benefit from these efforts. The core physics of a magnetically confined hot plasma has two essential components; plasma stability and cross-field energy transport physics. Complete understanding of these two areas is critical for the successful operation of ITER and perhaps, Demo reactor construction. In order to have stable high beta plasmas with a sufficiently long confinement time, the physics of an abrupt disruption and sudden deterioration of the energy transport must be understood and conquered. Physics issues associated with transient harmful MHD behavior and turbulence based energy transport are extremely complicated and theoretical understanding needs a clear validation and verification with a new research approach such as a multi-dimensional visualization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Overview Of The ITER In-Vessel Coil Systems

ELM mitigation is of particular importance in ITER in order to prevent rapid erosion or melting of the divertor surface, with the consequent risk of water leaks, increased plasma impurity content and disruptivity. Exploitable "natural" small or no ELM regimes might yet be found which extrapolate to ITER but this cannot be depended upon. Resonant Magnetic Perturbation has been added to pellet pacing as a tool for ITER to mitigate ELMs. Both are required, since neither method is fully developed and much work remains to be done. In addition, in-vessel coils enable vertical stabilization and RWM control. For these reasons, in-vessel coils (IVCs) are being designed for ITER to provide control of Edge Localized Modes (ELMs) in addition to providing control of moderately unstable resistive wall modes (RWMs) and the vertical stability (VS) of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗