Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICSBEP Benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

266 records · Page 15

Critical Configuration and Physics Measurements for Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

A series of critical experiments were completed from 1962–1965 at Oak Ridge National Laboratory’s (ORNL’s) Critical Experiments Facility (CEF) in support of the Medium-Power Reactor Experiments (MPRE) program. In the late 1950s, efforts were made to study “power plants for the production of electrical power in space vehicles.”(a) The MPRE program was a part of those efforts and studied the feasibility of a stainless-steel system, boiling potassium 1 MW(t), or about 140 kW(e), reactor. The program was carried out in [fiscal years] 1964, 1965, and 1966. A summary of the program’s effort was compiled in 1967.a The delayed critical experiments were a mockup of a small, potassium-cooled space power reactor for validation of reactor calculations and reactor physics methods. Initial experiments, performed in November and December of 1962, consisted of a core of unmoderated stainless-steel tubes, each containing 26 UO 2 fuel pellets, surrounded by a graphite reflector. Measurements were performed to determine critical reflector arrangements, relative fission-rate distributions, and cadmium ratio distributions. Subsequent experiments used beryllium reflectors and also measured the reactivity for various materials placed in the core. “The [assemblies were built] on [a] vertical assembly machine so that the movable part was the core and bottom reflector” (see Reference 1). The experiment studied in this evaluation was the second of the series and had the fuel rods in a 1.506-cm-triangular pitch. One critical configuration was found (see Reference 3). Once the critical configuration had been achieved, various measurements of reactivity, relative axial and radial activation rates of 235U,bc and cadmium ratios were performed. The cadmium ratio, reactivity, and activation rate measurements performed on the critical configuration are described in Sections 1.3, 1.4, and 1.7, respectively.

1.506-cm pitch↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

Oralloy (93.2 235 U) Bare Metal Annuli And Disks

A multitude of critical experiments with highly enriched uranium metal were conducted in the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. These experiments served to evaluate the storage, casting, and handling limits for the Y-12 Plant while also providing data for verification of different calculation methods and associated cross-sections for nuclear criticality safety applications. These included both solid cylinders and annuli of various diameters, interacting cylinders of various diameters, parallelepipeds, and reflected cylinders and annuli. The experiments described here involve a series of delayed critical stacks of bare oralloy HEU annuli and disks. Three of these experiments consist of stacking bare HEU annuli of varying diameters to obtain critical configurations. These annuli have nominal inner and outer diameters (ID/OD) including: 7 inches (") ID – 9" OD, 9" ID – 11" OD, 11" ID – 13" OD, and 13? ID – 15" OD. The nominal heights range from 0.125" to 1.5". The three experiments themselves range from 7" – 13", 7" – 15", and 9" – 15" in diameter, respectively. The fourth experiment ranges from 7" – 11", and along with different annuli, it also includes an 11" disk and several 7" diameter disks. All four delayed critical experiments were configured and evaluated by J. T. Mihalczo, J. J. Lynn, and D. E. McCarty from December of 1962 to February 1963 with additional information in their corresponding logbook.

42 ENGINEERING↗

Flattop Benchmark CED-2 (IER-423)

The final design for the Flattop HEU Core Benchmark is presented in this report. Physical measurements will be performed on Flattop components using modern instruments and techniques to define uncertainties necessary to meet contemporary ICSBEP standards. A preliminary re-evaluation of ICSBEP HMF-0028 (Flattop HEU Core) led to the development of IER-423 CED-1, wherein total relative uncertainties in $k_{eff}$ were provided based on a new detailed model. The estimated uncertainty on the total uncertainty is +100%/-0%, given a lack of documented uncertainties on mass, dimensions, and densities of predominantly the natural uranium (NU) and highly enriched uranium (HEU) components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity studies to Support TEX critical experiments design

In the frame of the ongoing Thermal/Epithermal experiments program, supported by the DOE-NCSP, we are characterizing expected data with analysis of sensitivity coefficients to nuclear data. The computations were performed for detailed and simplified models of the experimental configurations in order to demonstrate their invariance with respect to small geometry variations. The sensitivity coefficients were computed with recently developed precise methodologies using Monte Carlo tools (MCNP-6.1, SCALE 6.1 and MORET 5.C.1) with the following nuclear data libraries: ENDF/B-VII.0, ENDF/B-VII.1, and JEFF3.1. Since the considered experiments are devoted to tantalum data validation, their neutronic characteristics are compared with the relevant integral experiment data collected in the OECD/NEA ICSBEP Handbook. Although analysis of sensitivity coefficients taken alone is insufficient for an entire assessment, we can conclude that TEX experimental results can fill gaps in the available benchmarks to facilitate quantification of uncertainty for plutonium containing systems with epithermal neutron spectra (e.g. wet plutonium-based powders). However, analysis of sensitivity profiles demonstrates that an advanced statistical methodology will be needed to fit tantalum nuclear data or to evaluate the associated uncertainties. (authors)

42 ENGINEERING↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

reactivity worth measurements↗

Microreactor Assembly Transportation Cask Model Description for Criticality Safety Validation Basis Assessment

Criticality safety analyses are completed on a transportation cask used for microreactor assembly shipment to provide an example of model and analysis to industry for reproducing this type of study on their microreactor fuel shipment. The fuel assembly considered is based on a gas-cooled microreactor (GC-MR), which utilizes HALEU fuel in the form of TRISO particles and utilizes various design options considered in industry designs. Various versions of this GC-MR assembly were studied, with and without YH2 moderator, providing similar conclusions. The shipment cask design is revised based on an existing design ES-3100, developed by Y-12 for the transport of highly enriched uranium (HEU), but is enlarged to hold the GC-MR fuel assembly. Criticality safety analysis for the cask/GC-MR fuel assembly package was performed using the CSAS6 sequence of SCALE6.3.2, utilizing the ENDF/B-VII.1 based continuous energy neutron library, and the analysis strictly follows the guideline from NRC reference reports. Different scenarios, e.g. normal operation, undamaged cask with water flooded, damaged cask with optimal water moderation, have been analyzed and it could be concluded the package would always have a large margin of subcriticality even packed in an infinite array. Sensitivity and similarity analyses are also performed using the TSUNAMI sequence of SCALE6.3.2, and the similarity analysis uses all the experiments from the ICSBEP Handbook with Intermediate and Mixed Enriched Uranium (IEU) and Low Enriched Uranium (LEU) systems together with additional ones that are sponsored by the DNCSH program. These similarity analyses indicate that dry cases have no similar benchmark experiments (ck values greater than 0.8), which may become problematic if more assemblies are shipped together (or a fully loaded core is shipped) and margin to criticality is reduced. However, the damaged cask models with flooded assemblies exhibited similarities to many experiments with ck values greater than 0.8.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Updates to the n+ 63,65 Cu Angular Distributions [Slides]

The performance of the benchmark suite is very sensitive to changes in the angular distribution data. The quasi-differential measurements performed by Blain et al at RPI provide a valuable constraint. Furthermore, ENDF/B-VIII.0 disagrees with their measurements consistently at 300 keV (the transition between RRR and high energy). The next step is to conservatively adjust the Legendre coefficients near 300 keV, validating performance against both critical benchmarks and the RPI quasi-differential measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Increased Fidelity and Associated Computational cost of Detailed Integral Experiment Benchmarks [Slides]

It does not seem like the system is significantly more sensitive to diameters of components near the center of the core. Intuitively it is, but was not detectable with simulations run to a Monte Carlo k eff uncertainty of 0.00002. The system is more sensitive to heights of components near the center of the core. Most (if not all) Zeus style benchmarks have perturbed core component heights individually.

42 ENGINEERING↗

Microreactor Assembly Transportation Cask Model Description for Criticality Safety Validation Basis Assessment (Rev. 3)

Criticality safety analyses are completed on a transportation cask used for microreactor assembly shipment to provide an example of model and analysis to industry for reproducing this type of study on their microreactor fuel shipment. The fuel assembly considered is based on a gas-cooled microreactor (GC-MR), which utilizes HALEU fuel in the form of TRISO particles and utilizes various design options considered in industry designs. Various versions of this GC-MR assembly were studied, with and without YH 2 moderator, providing similar conclusions. The shipment cask design is revised based on an existing ES-3100 design, developed by Y-12 for the transport of highly enriched uranium (HEU), but is enlarged to hold the GC-MR fuel assembly. Criticality safety analysis for the cask/GC-MR fuel assembly package was performed using the CSAS6 sequence of SCALE6.3.2, utilizing the ENDF/B-VII.1 based continuous energy neutron library, and the analysis strictly follows the guideline from NRC reference reports. Different scenarios, e.g. normal operation, undamaged cask with water flooded, damaged cask with optimal water moderation, have been analyzed and it could be concluded the package would always have a large margin of subcriticality even packed in an infinite array. Sensitivity and similarity analyses are also performed using the TSUNAMI sequence of SCALE6.3.2, and the similarity analysis uses all the experiments from the ICSBEP Handbook with Highly Enriched Uranium (HEU), Intermediate and Mixed Enriched Uranium (IEU) and Low Enriched Uranium (LEU) systems, together with additional ones that are sponsored by the DNCSH program, and selected IRPhEP experiments using TRISO fuel and graphite moderator. These similarity analyses indicate that the dry nominal design has no similar benchmark experiments (ck values greater than 0.8), which may become problematic if more assemblies are shipped together (or a fully loaded core is shipped) and margin to criticality is reduced. However, the cask models with flooded assemblies exhibited similarities to many experiments with c k values greater than 0.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data?

Nuclear data are used for a variety of applications, including criticality safety, reactor performance, and material safeguards. Despite the breadth of use-cases, the effective neutron multiplication factor, keff, of ICSBEP critical assemblies are primarily used for nuclear data validation; these are sensitive to specific energy regions and nuclides and are unable to uniquely constrain nuclear data. As a consequence, general-purpose nuclear data libraries, such as ENDF/B-VIII.0, may have deficiencies that, while not apparent in criticality applications, negatively impact other applications, such as non-destructive analysis of special nuclear material and neutron diagnosed subcritical experiments. Recent work by the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project developed a machine learning tool, RAFIEKI, which uses random forests and the SHAP metric to determine which nuclear data contribute most to predicted bias between measured and simulated responses (e.g. keff). This paper contrasts RAFIEKI analysis applied to keff only against RAFIEKI analysis with keff paired with either LLNL pulsed sphere measurements or subcritical benchmarks. Two examples show that a) including pulsed sphere measurements substantially increases 9Be nuclear data importance to bias between 2 and 15 MeV, and b) including subcritical benchmarks has the potential for disentangling compensating errors between 240Pu (n,el) and (n,il) cross-sections between 0.1 and 10 MeV. These results show that RAFIEKI analysis applied to response sets that include, but go beyond, keff can aid nuclear data evaluators in identifying issues in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Addendum to ICSBEP Logbooks 12r, 13r, 14r and 15r for Polyethylene and Graphite Reflected HEU Metal Critical Experiments

This report documents the experimenters’ data sheets that were recently (2023) discovered for critical experiments with highly enriched uranium metal with polyethylene and graphite reflectors. These data sheets were produced at the time of the measurements, when the dimensional inspection reports for the polyethylene and graphite were available. However, at this writing, those inspection reports are not available but may be in unmarked storage for the Y-12 National Security Complex. However, the data sheets presented herein contain sketches of the experimental configurations and other additional information that is not in the logbooks, such as dimensions and masses of the graphite measurements. This report reproduces the experimental data sheets that complement the logbooks. Some of the data on these sheets and the logbooks can be used to infer the dimensions and masses that are not documented. Some obvious mistakes in the logbook and data sheets have been corrected. In the reproduced data sheets, some of the information is not clearly visible: some information, such as average values, can be obtained from other data in the sheets or logbook. This report should be sent to the International Criticality Safety Benchmark Program at Idaho National Laboratory to complement the existing Oak Ridge Critical Facility logbooks there.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A simple json format for storing and exchanging code calculation and experimental results

Calculation codes and code systems give their results in a plethora of different formats and/or files. For instance, MCNP gives a user the MCNP specific output file, the mctal file, the ptrac file, etc. while PARTISN has a PARTISN specific output file and a number of binary files with various kinds of information about the calculation. However, the results we are interested in are always the same. These can be single values such as the effective multiplication factor k eff or the effective delayed neutron fraction β eff . It can be histogram data (such as particle spectra, reaction rates, sensitivity profiles, etc.) or even pointwise data (for example the nuclide composition as a function of time, etc.). It is also worthwhile to note that this would also apply to experimental data that we may wish to compare with as well. Calculation and experimental results can basically be split into two components: attributes (or metadata) and the actual result itself. Attributes represent information about the result that are not necessarily required for its’ interpretation but that are still good to have. Often, these attributes are what we will want to filter results on. This means that these attributes are often the answer to specific questions we may have about the result. The following is a non exhaustive list of such basic questions: what type of result is it: e.g. the effective multiplication factor k eff , the effective delayed neutron fraction β eff , etc.; which case does it relate to: e.g. a specific ICSBEP case such as PU-MET-FAST-001-001; which code and version produced this result: e.g. MCNP 6.2, etc.; which nuclear data library was used to obtain the result: e.g. ENDF/B-VIII.0 or JEFF 3.3; which nuclide and reaction does it apply to (for reaction rates and sensitivity profiles); which volume in the geometry was it calculated in? The second component of the calculation or experimental result is the actual numerical data of the result. It is this data that we want to compare, exchange, plot, interpret, etc. It consists of values with optional uncertainties and units. It also includes the underlying structure (if any structure is required to interpret the result). Depending on the type of result, it may be a single value (e.g. the effective multiplication factor), an array of values (e.g. a reaction rate or particle spectrum) or even a multidimensional array. In order to exchange results between different organisations, for instance for benchmarking, people often resort to spreadsheets or custom text files that need to be filled out. While this approach works well if little information is to be exchanged, it can become cumbersome when dealing with large amounts of data (like for instance particle spectra for thousands of cases). In addition, such an approach does not always capture the metadata we may be interested in to allow for automated processing of these files. The purpose of this report is to propose a standardised json structure to store any type of result and present an associated python interface to interact with these results directly. For such a structure to be useful, it must fulfill a specific set of functional requirements that we try to meet with this proposal. The format must allow for the calculation result to stand by itself. This means that we should not have to look in multiple places to be able to understand it. For example, if the result relates to a particle spectrum, the group structure in which the result is given should be stored with it. The format should be code agnostic. This means that we do not need to know where it came from to understand it. The format should be result type agnostic. This means that the format must be generic enough so that we can even use it for results we have not thought of yet. The format should be relatively easy to interact with through different scripting or programming languages (i.e. the machine interface) while still providing a clean structure that can be used directly by any human.

97 MATHEMATICS AND COMPUTING↗