Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An Automatic Learning Framework for Smart Residential Communities

Predictability has been foundational to matching supply and demand in the day-to-day operation of the electric power system. Demand predictability is eroding because of the increased use of renewable energy resources and more sophisticated loads, such as electric vehicles and smart appliances. In this paper, an automatic software framework is described which can be used for load forecasting in smart communities. A time-varying clustering-based Markov chain approach is used to predict the energy consumption of residential buildings in a smart community. The training data is based on 1-minute meter data of occupied homes over one month. The data points are first clustered based on the energy consumption and the time of the day. Then, the original data is converted using the Centroids of the clusters. A time-varying Markov chain is subsequently trained to model the energy consumption behavior of residents for each home using the transformed data. The trained model is shown to successfully predict load in 5-minute intervals over a 24 hours period.

Zandi, Helia↗

High-performance and high-fidelity Monte Carlo solutions to the BEAVRS benchmark

The BEAVRS (Benchmark for Evaluation and Validation of Reactor Simulation) benchmark is solved by PRAGMA, the GPU-based continuous energy Monte Carlo code. The resulting solutions are comprised of the detailed simulation results of two cycles, each of which consists of the zero power physics test (ZPPT) and the core depletion calculations. The ZPPT consists of characteristic parameters, such as critical boron concentration (CBC), control rod bank worth, isothermal temperature coefficients, and assembly-wise detector signal, which are compared with measured data provided by the benchmark administration. The core depletion calculations were performed for both the hot full power and the load follow modes, and the comparison was made with the measured or deduced CBCs and assembly-wise detector signals. In the load follow calculations, the operating power history was approximately applied to simulate the real operation as closely as possible. PRAGMA performed the various calculations with a tremendous number of histories ranging up to hundreds of millions per cycle, exploiting GPUs' massively parallel performance. The load follow run time was shorter than 16 hours on a single rack of computing nodes mounded with 24 gaming GPUs with a remarkable agreement with the measurements for most comparisons. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An analytical investigation of the performance of solar collectors as nighttime heat radiators in airconditioning cycles

It was found that if the upper and lower ends of a collector were opened, large free convention currents may be set up between the collector surface and the cover glass(es) which can result in appreciable heat rejection. If the collector is so designed that both plates surfaces are exposed to convection currents when the upper and lower ends of the collector enclosure are opened, the heat rejection rate is 300 watts sq m when the plate is 13 C above ambient. This is sufficient to permit a collector array designed to provide 100 percent of the heating needs of a home to reject the accumulated daily air conditioning load during the course of a summer night. This also permits the overall energy requirements for cooling to be reduced by at least 15 percent and shift the load on the utility entirely to the nighttime hours.

Jones, C. B.↗

Quiet Clean Short-haul Experimental Engine (QCSEE) composite fan frame design report

An advanced composite frame which is flight-weight and integrates the functions of several structures was developed for the over the wing (OTW) engine and for the under the wing (UTW) engine. The composite material system selected as the basic material for the frame is Type AS graphite fiber in a Hercules 3501 epoxy resin matrix. The frame was analyzed using a finite element digital computer program. This program was used in an iterative fashion to arrive at practical thicknesses and ply orientations to achieve a final design that met all strength and stiffness requirements for critical conditions. Using this information, the detail design of each of the individual parts of the frame was completed and released. On the basis of these designs, the required tooling was designed to fabricate the various component parts of the frame. To verify the structural integrity of the critical joint areas, a full-scale test was conducted on the frame before engine testing. The testing of the frame established critical spring constants and subjected the frame to three critical load cases. The successful static load test was followed by 153 and 58 hours respectively of successful running on the UTW and OTW engines.

Mitchell, S. C.↗

Thermal stability of the microstructure of an aged Nb-Zr-C alloy

The effects of thermal aging with and without an applied stress on the microstructure of a Nb-Zr-C alloy containing 0.9 wt percent Zr and 0.06 percent C were studied. Chemical analysis, metallographic examination, energy dispersive X-ray spectra of the bulk material, and chemical and X-ray analyses of the phase-extracted residue were used to characterize the microstructure. The samples examined were from a creep strength study involving hot and cold working, and various combinations of exposure to temperatures ranging from 1350 to 1755 K with and without applied load times as long as 34,000 plus hours. The results showed that the initial microstructure consisted primarily of orthorombic precipitates of Nb sub C which were partially or completely transformed to face-centered cubic carbides of Nb and Zr, (Zr, Nb)C, upon prolonged exposure to elevated temperatures. Furthermore, it was found that the microstructure of the alloy is extremely stable owing to the very finely distributed precipitates throughout its matrix and along the grain boundaries. The lattice parameters of the cubic carbides were determined to vary from 0.458 to 0.465 nm as the Zr/Nb ratio varied from 38/62 to 75/25.

Uz, Mehmet↗

Washing Away the Worries About Germs

Fresh fruits and vegetables have been in demand by orbiting astronauts since the early days of the Space Shuttle. As one can imagine, however, oranges, onions, tomatoes, garlic, and other fresh items can provide a cornucopia of smells in a closed environment such as the Space Shuttle or the International Space Station (ISS), especially when they begin to perish. It does not help that they are loaded onto the Space Shuttle up to 24 hours in advance of a launch, and that the on-orbit shelf life is just 2 to 3 days for most, due to a lack of refrigeration. While such produce adds significant variety to astronauts diets and increases their morale, the odor that emanates from it as it ages can cause nausea. One of the last things astronauts need is associating this healthy fare with feelings of nausea. NASA is currently investigating the use of a commercial sanitation product it helped develop with private industry to thoroughly cleanse and, thus, increase the shelf life of fruits and vegetables being sent into space. Meanwhile, this product is ripe for the picking for consumers looking to do the same, and more, on Earth.

Source record↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

GSE Yearly Load Profiles for Each Airport Under Six Charging Scenarios

This dataset contains GSE yearly load profiles for each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse_load_profile_sample_day.png) GSE load profile of a sample day across different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Proposed Study Examining Individual Differences in Temporal Profiles of Cardiovascular Responses to Head Down Tilt During Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. Hypovolemia, reduced plasma volume, is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore lost plasma volume by giving crew salt tablets and water prior to re-entry. The main purpose of the proposed study is to define the temporal profile of cardiac responses to simulated 0-G conditions before and following a fluid loading countermeasure. 8 men and 8 women will be tested during 4 hour exposures at 6o head down tilt (HDT). Each subject will be given two exposures to HDT on separate days, one with and one without fluid loading (one liter of 0.9% saline solution). Stand tests (orthostatic stress) will be done before and after each HDT. Cardiac measures will be obtained with both impedance cardiography and echo ultrasound

Cowings, Patricia↗

Assessing Customer Experience and Business Models around Price-to-Device Communication and Smart Control Pathways in CalFlexHub

California is facing three major challenges in electrical grid operation: renewable overgeneration, steep evening ramping, and growing peak demand. The state has identified dynamic retail price response as a key strategy evidenced by CPUC’s Dynamic Rates proceeding and CEC’s Load Management Standards. Furthermore, the CEC launched a $16M “California Load Flexibility Research and Deployment Hub (CalFlexHub)” administered by Berkeley Lab to accelerate price-response flexible load technologies in buildings and EV charging. There are more than 16 laboratory and field demonstration projects in CalFlexHub, each demonstrating innovative automated price-response technologies. CalFlexHub tests various pathways through which hourly price signals and triggered control commands are communicated to load-flexible devices such as smart thermostats, heat pumps, water heaters, and EVs. We identified seven unique communication and control pathways, which involve combinations of third-party cloud, device OEM’s cloud, building central gateway, and local controller in between the price server and the load-flexible devices. It is important for utilities and policy makers to understand the long-term implications of each pathway in designing future programs and creating related policies and mandates for market transformation. We propose an evaluation framework including the following aspects: ● Functionality: connectivity and uptime, resilience, and optimization; ● Customer experience: simplicity in setup, troubleshooting support, continuity, customer choice, first cost, and ongoing cost; ● Business model and scalability: advance interoperability, holistic solution, bridge unique gap, customer base, and value streams and pricing structures. In this paper, we identify emerging business models associated with each communication pathway and discuss their positive features and challenges from the above aspects.

Liu, Jingjing↗

Analysis of wing truss stresses including the effect of redundancies

Airplane wing trusses are generally designed to contain redundant members (stagger wires and external drag wires) which, according to common practice, are not taken into account in calculations, so as to simplify the stress analysis by rendering the structure statically determinate. A more accurate method, in which the redundancies are included, involves a solution by means of Castigliano's method of least work. For the purpose of demonstrating the practical application of the method of least work this report presents examples for stresses of several cases of loading worked out for a structure similar to that of the Curtiss JN-4h. Case 1 was taken as the condition of velocity of 100 miles per hour combined with the angle of attack of maximum lift. Case 1a assumed the same loading but neglected the distortion of wooden members in the least-work analysis. So little error was involved in case 1a that this simplified method was employed for each succeeding case. Case 2 assumed a diving speed of 120 miles per hour and an angle of attack of no lift. Case 3 was worked out for the conditions imposed by the sand load recommended in NACA technical note no. 6.

Warner, E P↗

Load Composition Analysis in Support of the NERC Load Modeling Task Force. 2019-2020 Field Test of the Composite Load Model

In 2015, NERC’s reliability standards were revised to require the use of dynamic load models in transmission planning studies. To comply with the standards, planners must use load models that explicitly represent the dynamic behavior of the different constituents of load at each load bus within their transmission planning models. The most important of these constituents are motor-driven and power electronics-based loads. Collectively, these representations are known as composite load models. In anticipation of the compliance date for the new standards, NERC’s Load Modeling Task Force (LMTF), in 2019, initiated a field test of composite load models involving the regional reliability planning entities. In support of the field test, DOE and BPA researchers developed region-specific composite load models that could be assigned to each non-industrial load bus in the planning models for each of the North American interconnections. Separate models were developed for each hour of a summer peak day, a winter peak day, and a spring light-load day. This report is the technical documentation for the load composition analysis that was conducted to develop these non-industrial composite load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Erosion/corrosion of turbine airfoil materials in the high-velocity effluent of a pressurized fluidized coal combustor

Four candidate turbine airfoil superalloys were exposed to the effluent of a pressurized fluidized bed with a solids loading of 2 to 4 g/scm for up to 100 hours at two gas velocities, 150 and 270 m/sec, and two temperatures, 730 deg and 795 C. Under these conditions, both erosion and corrosion occurred. The damaged specimens were examined by cross-section measurements, scanning electron and light microscopy, and X-ray analysis to evaluate the effects of temperature, velocity, particle loading, and alloy material. Results indicate that for a given solids loading the extent of erosion is primarily dependent on gas velocity. Corrosion occurred only at the higher temperature. There was little difference in the erosion/corrosion damage to the four alloys tested under these severe conditions.

Zellars, G. R.↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Damage Accumulations Predictions for Boiler Components Via Microstructurally Informed Material Models

The goal of the project was to model material behavior and degradation during cyclic plasticity— with and without hold time—for nickel-based superalloys used in USC (ultra-super-critical) and A-USC (advanced-ultra-super-critical) boiler components. The study provided physically informed models, capturing the microstructural changes taking place in the industrial components under cyclic loading and long duration stress (up to 300,000 hours) and high temperature exposure (1100°F/593°C to 1400°F/760°C). The major developments were: 1) Qualitative and quantitative understanding of microstructure evolution (gamma prime precipitates), deformation (dislocation density), and damage mechanisms of Haynes ® 282 alloy. 2) Qualitative understanding of microstructural features generating local strain variations. 3) A continuum damage mechanics model (CDM) for Haynes ® 282 alloy at 1100°F to 1400°F capturing cyclic behavior with and without hold time. 4) Structural analysis for creep and LCF life predictions of an USC thick-wall Grade 91 superheater steel header and understanding life sensitivity to wall thickness of an AUSC Haynes ® 282 header.

20 FOSSIL-FUELED POWER PLANTS↗