Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homeland Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

MCNPX-PoliMi for Nuclear Nonproliferation Applications

In the past few years, efforts to develop new measurement systems to support nuclear nonproliferation and homeland security have increased substantially. Monte Carlo radiation transport is one of the simulation methods of choice for the analysis of data from existing systems and for the design of new measurement systems; it allows for accurate description of geometries, detailed modeling of particle-nucleus interactions, and event-by-event detection analysis. This paper describes the use of the Monte Carlo code MCNPX-PoliMi for nuclear-nonproliferation applications, with particular emphasis on the simulation of spontaneous and neutron-induced nuclear fission. In fact, of all possible neutron-nucleus interactions, neutron-induced fission is the most defining characteristic of special nuclear material (such as U-235 and Pu-239), which is the material of interest in nuclear-nonproliferation applications. The MCNP-PoliMi code was originally released from the Radiation Safety Shielding Center (RSSIC) at Oak Ridge National Laboratory in 2003 [1]; the MCNPX-PoliMi code contains many enhancements and is based on MCNPX ver. 2.7.0. MCNPX-PoliMi ver. 2.0 was released through RSICC in 2012 as a patch to MCNPX ver. 2.7.0 and as an executable [2].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron response characterization for an EJ299-33 plastic scintillation detector

Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here in this paper, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuous spectrum neutron source, obtained via the bombardment of 27 Al with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the scintillation decay time for different energy deposited by γ-rays and neutrons in a Cs 2 LiYCl 6 :Ce 3+ detector

In nuclear safeguards and homeland security applications, it is greatly beneficial to simultaneously detect γ-rays, thermal neutrons, and fast neutrons using a single detector with reasonable pulse shape discrimination capability, energy resolution comparable with or even better than NaI(Tl) detectors, and high detection efficiency. Cs 2 LiYCl 6 :Ce 3+ detector (CLYC) scintillation detectors have been proven to be one promising candidate to meet these requirements. In this work, the decay time and fraction of each scintillation component for different energy deposition and incident particle type (γ-ray, thermal neutron, and fast neutron) were investigated based on fitting the PMT anode output with exponential functions. For γ-rays, four components were determined with ultrafast decay time of less than one nanosecond and slow time in the order of magnitude of microsecond. It was found that the dependence on the energy deposited by γ-rays of the fraction as well as the decay time of the three slow components was small. However, significant dependence was observed for the ultrafast component. Two or three components were determined for thermal neutrons and fast neutrons without observing a component with fast decay time. To verify the approach used it was first applied to scintillation pulses induced by γ-rays in a NaI(Tl) detector. We found the results were consistent with well-known data already published in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectral analysis of shielded gamma ray sources using precalculated library data

In this paper, an approach has been developed for determining the intensity of a shielded source by first determining the thicknesses of three different shielding materials from a passively collected gamma-ray spectrum by making comparisons with predetermined shielded spectra. These evaluations are dependent on the accuracy and validity of the predetermined library spectra which were created by changing the thicknesses of the three chosen materials lead, aluminum and wood that are used to simulate any actual shielding. Each of the spectra produced was generated using MCNP5 with a sufficiently large number of histories to ensure a low relative error at each channel. The materials were held in the same respective order from source to detector, where each material consisted of three individual thicknesses and a null condition. This then produced two separate data sets of 27 total shielding material situations and subsequent predetermined libraries that were created for each radionuclide source used. The technique used to calculate the thicknesses of the materials implements a Levenberg–Marquardt nonlinear search that employs a tri-linear interpolation with the respective predetermined libraries within each channel for the supplied input unknown spectrum. Given that the nonlinear parameters require an initial guess for the calculations, the approach demonstrates first that when the correct values are input, the correct thicknesses are found. It then demonstrates that when multiple trials of random values are input for each of the nonlinear parameters, the average of the calculated solutions that successfully converges also produced the correct thicknesses. Under situations with sufficient information known about the detection situation at hand, the method was shown to behave in a manner that produces reasonable results and can serve as a good preliminary solution. Finally, this technique has the capability to be used in a variety of full spectrum inverse analysis problems including homeland security issues.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impurity Profiling to Match a Nerve Agent to Its Precursor Source for Chemical Forensics Applications

Chemical forensics is an emerging field in homeland security that aims to attribute a weaponized toxic chemical or related material to its source. Herein, for the first time, trace impurities originating from a chemical precursor were used to match a synthesized nerve agent to its precursor source. Specifically, multiple batches of sarin and its intermediate were synthesized from two commercial stocks of methylphosphonic dichloride (DC) and were then matched by impurity profiling to their DC stocks from out of five possible stocks. This was possible because each DC stock had a unique impurity profile that, for the tested stocks, persisted through synthesis, decontamination, and sample preparation. This work may form a basis for using impurity profiling to help find and prosecute perpetrators of chemical attacks.

Fraga, Carlos G.↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors

CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large mismatch in the thermal-expansion coefficient between the metal contacts and CZT, the contacts can undergo stress and mechanical degradation, which is the main cause for device instability over the long term. Here, we report for the first time on our use of Al-doped ZnO as the preferred electrode for such detectors. The material was selected because of its better contact properties compared to those of the metals commonly used today. Comparisons were conducted for the detector properties using different contacts and improvements in the performances of ZnO:Al-coated detectors are described in this paper. These studies show that Al:ZnO contacts to CZT radiation detectors offer the potential of becoming a transformative replacement for the common metallic contacts due to the dramatic improvements in the performance of detectors and improved long-term stability.

47 OTHER INSTRUMENTATION↗

Plasma physics and related challenges of millimeter-wave-to-terahertz and high power microwave generation

Homeland security and military defense technology considerations have stimulated intense interest in mobile, high power sources of millimeter-wave (mmw) to terahertz (THz) regime electromagnetic radiation, from 0.1 to 10 THz. While vacuum electronic sources are a natural choice for high power, the challenges have yet to be completely met for applications including noninvasive sensing of concealed weapons and dangerous agents, high-data-rate communications, high resolution radar, next generation acceleration drivers, and analysis of fluids and condensed matter. The compact size requirements for many of these high frequency sources require miniscule, microfabricated slow wave circuits. This necessitates electron beams with tiny transverse dimensions and potentially very high current densities for adequate gain. Thus, an emerging family of microfabricated, vacuum electronic devices share many of the same plasma physics challenges that are currently confronting 'classic' high power microwave (HPM) generators including long-life bright electron beam sources, intense beam transport, parasitic mode excitation, energetic electron interaction with surfaces, and rf air breakdown at output windows. The contemporary plasma physics and other related issues of compact, high power mmw-to-THz sources are compared and contrasted to those of HPM generation, and future research challenges and opportunities are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-ray waveguides

We have developed an approach for gamma-ray optics using layered structures acting as planar waveguides. Experiments demonstrating channeling of 122 keV gamma rays in two prototype waveguides validate the feasibility of this technology. Gamma-ray waveguides allow one to control the direction of radiation up to a few MeV. The waveguides are conceptually similar to polycapillary optics, but can function at higher gamma-ray energies. Optics comprised of these waveguides will be able to collect radiation from small solid angles or concentrate radiation into small area detectors. Gamma-ray waveguides may find applications in medical imaging and treatment, astrophysics, and homeland security.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tenfold improved sensitivity using high refractive-index substrates for surface plasmon sensing

Surface plasmon resonance sensors exploit the high sensitivity to local perturbations of plasma waves in a thin metal layer. These devices have a wide range of applications as biomedical, environmental, industrial, and homeland security. We concentrate on the theoretical aspects of the sensing principle. By calculations at various indexes of refraction we proved that using substrate material of higher index, sensitivity and dynamics range improve conspicuously. Finally, we show experimental data taken using a special transparent ceramic material of exceptionally high index of refraction n=2.04. Tests demonstrate sensitivity about one order of magnitude better than those obtained with conventional BK7 glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Yield With a Pulsed Surface Flashover Deuterium Source

As a step towards developing an ultra compact D-D neutron source for various defense and homeland security applications, a compact, low average power ion source is needed. Towards that end, we are testing a high current, pulsed surface flashover ion source, with deuterated titanium as the spark contacts. Neutron yield and source lifetime data will be presented using a low voltage (<100 kV) deuterated target. With 20 ns spark drive pulses we have shown >10{sup 6} neutrons/s with 1 kHz PRF.

43 PARTICLE ACCELERATORS↗

Radiochemistry Education and Research Program at the Pennsylvania State University

A new Radiochemistry Education and Research Program was started at the Pennsylvania University, Radiation Science and Engineering Center. The program was initially supported by the Department of Energy, Radiochemistry Education Award Program (REAP). Using REAP funding as leverage we obtained support from the Los Alamos National Laboratory, Department of Homeland Security, Domestic Nuclear Detection Office, various internal funding from PSU and other entities. The PSU radiochemistry program primarily addresses radiochemistry education and secondarily nuclear and radiochemistry research. The education program consists of bolstering our existing radiochemistry and related courses; Nuclear and Radiochemistry, Radiation Detection and Measurement, Radiological Safety and developing new courses, e.g., Laboratory Experiments in Applied Nuclear and Radiochemistry, and Nuclear Methods in Science. A new laboratory has been created with state of the art equipment for the Laboratory Experiments in Applied Nuclear and Radiochemistry course. We also plan to revitalize the nuclear and radiochemistry research programs. We established a state-of-the-art Neutron Activation Analysis Laboratory and a gamma ray spectroscopy laboratory that has 10 stations including state-of-the-art nuclear spectroscopy hardware and software. In addition, we embarked on an expansion plan that included building a new neutron beam hall and neutron beam ports with a cold neutron source. One of the reasons to have a cold neutron source is for the development of a prompt gamma activation analysis facility. A detailed description of PSU radiochemistry education and research program will be given and the future plans will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Establishment of an Undergraduate Research and Training Program in Radiochemistry at Florida Memorial University, a Historically Black College or University (HBCU)

With the passing of the Energy Policy Act of 2005, the United States is experiencing for the first time in over two decades, what some refer to as the 'Nuclear Renaissance'. The US Nuclear Regulatory Commission (NRC) recognizes this surge in application submissions and is committed to reviewing these applications in a timely manner to support the country's growing energy demands. Notwithstanding these facts, it is understood that the nuclear industry requires appropriately trained and educated personnel to support the growing needs of the nuclear industry and the US NRC. Equally important is the need to educate the next generation of students in nuclear non-proliferation, nuclear forensics and various aspects of homeland security for the national laboratories and the Department of Defense. From mechanical engineers educated and experienced in materials, thermal/fluid dynamics, and component failure analysis, to physicists using advanced computing techniques to design the next generation of nuclear reactor fuel elements, the need for new engineers, scientists, and health physicist has never been greater.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Start, Stop, Restart: The Recent History of Federal Funding for Radiochemistry Education

Over the course of the 2009, Federal Fiscal Year the U.S. Departments of Homeland Security and Defense will introduce university programs designed to provide the U.S. national laboratories with a highly qualified workforce in nuclear forensics. These programs are designed to recruit the best and brightest students, develop universities research and education activities, and to enhance university/laboratory(s) interactions nuclear forensics. The approach will be comprehensive in that it will target undergraduate and graduate students, faculty members and institutions. This will include an undergraduate research program designed to encourage emerging seniors to perform research at designated national laboratories throughout the United States. In addition to the undergraduate program, a nationally competitive graduate fellowship program in nuclear forensics was established in 2008. This program provides a four-year appointment with a monthly stipend, full payment of tuition and fees, the establishment of participating universities, and required post-graduate positions in nuclear forensics. A Nuclear Forensics Education Award program will also be introduced. This broad-based program will have an impact on university programs interested in developing nuclear forensics capabilities. This will include funds for instrumentation and equipment, faculty members, students, and curriculum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hypergolic fuel detection using individual single walled carbon nanotube networks

Accurate and reliable detection of hypergolic fuels such as hydrazine (N{sub 2}H{sub 4}) and its derivatives is vital to missile defense, aviation, homeland security, and the chemical industry. More importantly these sensors need to be capable of operation at low temperatures (below room temperature) as most of the widely used chemical sensors operate at high temperatures (above 300 deg. C). In this research a simple and highly sensitive single walled carbon nanotube (SWNT) network sensor was developed for real time monitoring of hydrazine leaks to concentrations at parts per million levels. Upon exposure to hydrazine vapor, the resistance of the air exposed nanotubes (p-type) is observed to increase rapidly while that of the vacuum-degassed nanotubes (n-type) is observed to decrease. It was found that the resistance of the sample can be recovered through vacuum pumping and exposure to ultraviolet light. The experimental results support the electrochemical charge transfer mechanism between the oxygen redox couple of the ambient and the Fermi level of the SWNT. Theoretical results of the hydrazine-SWNT interaction are compared with the experimental observations. It was found that a monolayer of water molecules on the SWNT is necessary to induce strong interactions between hydrazine and the SWNT by way of introducing new occupied states near the bottom of the conduction band of the SWNT.

77 NANOSCIENCE AND NANOTECHNOLOGY↗