Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical and dynamical conditions in interstellar clouds

Techniques for measuring the local and global parameters that describe molecular clouds are presented and illustrated by selected results. The local parameters which characterize a given location in a cloud are gas kinetic temperature, dust temperature, total density, magnetic field strength, abundance of species i, volume cooling and heating rates for gas and dust, and the thermal and turbulent velocities. Global properties which characterize the cloud as a whole include the size expressed as a length or area, the orientation and shape, the mass, and the integrated heating and cooling rates. If the cloud as a whole is collapsing or rotating, then the collapse velocity and the rotational velocity or angular momentum are global properties. An intermediate class of parameters which shares features of local and global properties includes the column density of species i, the total column density, and the average density.

Evans, N. J., II↗

Mesoscale budgets of heat and moisture in a convective system over the central United States

Mesoscale heat and moisture budget calculations from the April 10-11 AVE-SESAME central U.S. region are calculated in order to diagnose the effect of midlatitude organized convection on its environment. When averaged over an area greater than the observational scale, the noise levels of 5 C/day for the heat budget and 2 g/kg per day for the moisture budget are considerably reduced. The credibility of such area-averaged budget results is indicated by the general agreement obtained between the observed rainfall rate and the vertically integrated heat sources and moisture sinks. The vertical convective heating that is diagnosed from this organized midlatitude convection differs significantly from tropical structures diagnosed on much larger temporal and spatial scales. A time lag of several hours between the moisture convergence and rainfall rate is noted.

Kuo, Y.-H.↗

Gyrokinetic studies of trapped electron mode turbulence in the Helically Symmetric eXperiment stellarator

Gyrokinetic simulations of plasma microturbulence in the Helically Symmetric eXperiment are presented. Using plasma profiles relevant to experimental operation, four dominant drift wave regimes are observed in the ion wavenumber range, which are identified as different flavors of density-gradient-driven trapped electron modes. For the most part, the heat transport exhibits properties associated with turbulence driven by these types of modes. Additionally, long-wavelength, radially localized, nonlinearly excited coherent structures near the resonant central flux surface, not predicted by linear simulations, can further enhance flux levels. Integrated heat fluxes are compatible with experimental observations in the corresponding density gradient range. Despite low shearing rates, zonal flows are observed to regulate turbulence but can be overwhelmed at higher density gradients by the long-wavelength coherent structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A relative-intensity two-color phosphor thermography system

The NASA LaRC has developed a relative-intensity two-color phosphor thermography system. This system has become a standard technique for acquiring aerothermodynamic data in LaRC Hypersonic Facilities Complex (HFC). The relative intensity theory and its application to the LaRC phosphor thermography system is discussed along with the investment casting technique which is critical to the utilization of the phosphor method for aerothermodynamic studies. Various approaches to obtaining quantitative heat transfer data using thermographic phosphors are addressed and comparisons between thin-film data and thermographic phosphor data on an orbiter-like configuration are presented. In general, data from these two techniques are in good agreement. A discussion is given on the application of phosphors to integration heat transfer data reduction techniques (the thin film method) and preliminary heat transfer data obtained on a calibration sphere using thin-film equations are presented. Finally, plans for a new phosphor system which uses target recognition software are discussed.

Merski, N. Ronald↗

ELM-free and inter-ELM divertor heat flux broadening induced by edge harmonics oscillation in NSTX

A new n =1 dominated edge harmonic oscillation (EHO) has been found in NSTX. The new EHO, rotating toroidally in the counter-current direction and the opposite direction of the neutral beam, was observed during certain inter-ELM and ELM-free periods of H-mode operation. This EHO is associated with a significant broadening of the integral heat flux width (${{\lambda}_{\operatorname{int}}}$ ) by up to 150%, and a decrease in the divertor peak heat flux by >60%. An EHO induced filament was also observed by the gas puff imaging diagnostic. The toroidal rotating filaments could change the edge magnetic topology resulting in toroidal rotating strike point splitting and heat flux broadening. Finally, experimental result of the counter current rotation of strike points splitting is consistent with the counter-current EHO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ELM-free and inter-ELM divertor heat flux broadening induced by Edge Harmonics Oscillation in NSTX

A new n=1 dominated Edge Harmonic Oscillation (EHO) has been found in NSTX. The new EHO, rotating toroidally in the counter-current direction and the opposite direction of the neutral beam, was observed during certain inter-ELM and ELM-free periods of H-mode operation. This EHO is associated with a significant broadening of the integral heat flux width (?_int) by up to 150%, and a decrease in the divertor peak heat flux by >60%. An EHO induced filament was also observed by the gas puff imaging diagnostic. The toroidal rotating filaments could change the edge magnetic topology resulting in toroidal rotating strike point splitting and heat flux broadening. Experimental result of the counter current rotation of strike points splitting is consistent with the counter-current EHO.

Divertor heat flux width↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

High capacity demonstration of honeycomb panel heat pipes

High capacity honeycomb panel heat pipes were investigated as heat rejection radiators on future space platforms. Starting with a remnant section of honeycomb panel measuring 3.05-m long by 0.127-m wide that was originally designed and built for high-efficiency radiator fins, features were added to increase thermal transport capacity and thus permit test evaluation as an integral heat transport and rejection radiator. A series of subscale panels were fabricated and reworked to isolate individual enhancement features. Key to the enhancement was the addition of a liquid sideflow that utilizes pressure priming. A prediction model was developed and correlated with measured data, and then used to project performance to large, space-station size radiators. Results show that a honeycomb panel with 5.08-cm sideflow spacing and core modification will meet the design load of a 50 kW space heat rejection system.

Tanzer, H. J.↗

Application of fuel cells with heat recovery for integrated utility systems

This paper presents the results of a study of fuel cell powerplants with heat recovery for use in an integrated utility system. Such a design provides for a low pollution, noise-free, highly efficient integrated utility. Use of the waste heat from the fuel cell powerplant in an integrated utility system for the village center complex of a new community results in a reduction in resource consumption of 42 percent compared to conventional methods. In addition, the system has the potential of operating on fuels produced from waste materials (pyrolysis and digester gases); this would provide further reduction in energy consumption.

Shields, V.↗

Thermal properties of the pyrochlore, Y{sub 2}Ti{sub 2}O{sub 7}

The thermal conductivity and heat capacity of high-purity single crystals of yttrium titanate, Y{sub 2}Ti{sub 2}O{sub 7,} have been determined over the temperature range 2 K<=T<=300 K. The experimental heat capacity is in very good agreement with an analysis based on three acoustic modes per unit cell (with the Debye characteristic temperature, theta{sub D}, of ca. 970 K) and an assignment of the remaining 63 optic modes, as well as a correction for C{sub p}-C{sub v}. From the integrated heat capacity data, the enthalpy and entropy relative to absolute zero, are, respectively, H(T=298.15 K)-H{sub 0}=34.69 kJ mol{sup -1} and S(T=298.15 K)-S{sub 0}=211.2 J K{sup -1} mol{sup -1}. The thermal conductivity shows a peak at ca. theta{sub D}/50, characteristic of a highly purified crystal in which the phonon mean free path is about 10 {mu}m in the defect/boundary low-temperature limit. The room-temperature thermal conductivity of Y{sub 2}Ti{sub 2}O{sub 7} is 2.8 W m{sup -1} K{sup -1}, close to the calculated theoretical thermal conductivity, kappa{sub min}, for fully coupled phonons at high temperatures. - Graphical Abstract: The thermal conductivity and heat capacity of high-purity single crystals of yttrium titanate, Y{sub 2}Ti{sub 2}O{sub 7,} have been determined in the range 2 K<=T<=300 K. The thermal conductivity shows a peak at ca. theta{sub D}/50, characteristic of a highly purified crystal in which the phonon mean free path is about 10 {mu}m in the defect/boundary low-temperature limit.

36 MATERIALS SCIENCE↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Integral Plug-Type Heat-Flux Gauge

Integral thermoplug gauge measures flux of heat across specimen of material. New gauge not screwed or welded into place, but instead thermoplug and annulus electrical-discharge-machined (EDM) into specimen material. EDM process leaves no interface between material and thermoplug, thus inherently increasing gauge accuracy by eliminating interface and associated temperature discontinuity. Process also conducive to accurate fabrication of minute gauges.

Liebert, Curt H.↗

Modeling of radiative heating of base region of Jovian entry probe

The mechanism of radiative heating of the afterbody region of Jovian entry probe is analyzed. A theoretical model is derived to determine the average thermodynamic properties in the expanding region, recirculating region, recompression region, and neck region through application of one-dimensional conservation equations. Flow parameters are obtained from the shadowgraphs of a free-flight test. Radiative transfer is calculated using spectrally detailed computer codes accounting for nonequilibrium. The results show that the most severe heating occurs immediately behind the frustum, and that the recompression and neck regions are the major sources of radiation that heats the base stagnation point. The radiation flux to the base point is slightly stronger with ablation than without, its value being 0.11(43Pb/Ps)squared times that to the front stagnation point, where Pb/Ps is the ratio of base-to-front stagnation point pressures and its value is in the range 0.023-0.066. The time-integrated heat load to the base point is 18(43Pb/Ps)squared kJ/sq cm. Existing experimental data are shown to agree with the theoretical prediction.

Park, C.↗

Comparison of experimental and simulated critical heat flux tests with various cladding alloys: Sensitivity of iron-chromium-aluminum (FeCrAl) to heat transfer coefficients and material properties

In this paper we analyze the differences between previous transient critical heat flux (CHF) experiments using iron-chromium-aluminum (FeCrAl), Inconel 600, and stainless steel 316 (SS316) alloy test sections and best-estimate modeling results from widely-used nuclear engineering systems and subchannel analysis tools. FeCrAl is an Accident Tolerant Fuel (ATF) candidate cladding material. The thermal hydraulic performance and safety characteristics of FeCrAl are being evaluated to determine viability as a cladding material in Light Water Reactors (LWRs). In this study, the results of the CHF experiments conducted at atmospheric pressure and fixed inlet coolant temperature and mass flux are compared to models built in the fifth version of the Reactor Excursion and Leak Analysis Program (RELAP5-3D) and CTF, the modernized version of COBRA-TF developed by the Consortium for Advanced Simulation of LWRs (CASL). Results from RELAP5-3D and CTF showed differences from the experiments and from each other in predicting CHF. In the Inconel 600 case, both computational tools overpredicted CHF, which led to an underprediction in the tube outer surface temperature. In the SS316 and FeCrAl cases, CHF was underpredicted by the codes, leading to an overprediction of the tube outer surface temperature. To understand the discrepancies in CHF and post-CHF predictions, studies were performed using RELAP5-3D and RAVEN to determine the sensitivity of CHF and peak test section temperature, an analog to peak cladding temperature (PCT), to heat transfer coefficients, a CHF multiplier, and uncertainties in the thermal conductivity and volumetric heat capacity. We found that CHF depends most strongly on the CHF multiplier and thermophysical properties. A combination of these factors that produced the best match to the experiment based on CHF, PCT, and the total energy deposited into the tube was determined. The best match parameters were able to provide best-estimate predictions of the CHF and integral heat flux, but were still conservative when predicting the PCT. The best match set of parameters developed in this paper are intended only as a demonstration of an approach that could be applied in the future with a larger set of experiments to produce more accurate models of CHF and post-CHF behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary assessment of rover power systems for the Mars Rover Sample Return Mission

Four isotope power system concepts were presented and compared on a common basis for application to on-board electrical prime power for an autonomous planetary rover vehicle. A representative design point corresponding to the Mars Rover Sample Return (MRSR) preliminary mission requirements (500 W) was selected for comparison purposes. All systems concepts utilize the General Purpose Heat Source (GPHS) isotope heat source developed by DOE. Two of the concepts employ thermoelectric (TE) conversion: one using the GPHS Radioisotope Thermoelectric Generator (RTG) used as a reference case, the other using an advanced RTG with improved thermoelectric materials. The other two concepts employed are dynamic isotope power systems (DIPS): one using a closed Brayton cycle (CBC) turboalternator, and the other using a free piston Stirling cycle engine/linear alternator (FPSE) with integrated heat source/heater head. Near term technology levels have been assumed for concept characterization using component technology figure-of-merit values taken from the published literature. For example, the CBC characterization draws from the historical test database accumulated from space Brayton cycle subsystems and components from the NASA B engine through the mini-Brayton rotating unit. TE system performance is estimated from Voyager/multihundred Watt (MHW)-RTG flight experience through Mod-RTG performance estimates considering recent advances in TE materials under the DOD/DOE/NASA SP-100 and NASA Committee on Scientific and Technological Information programs. The Stirling DIPS system is characterized from scaled-down Space Power Demonstrator Engine (SPDE) data using the GPHS directly incorporated into the heater head. The characterization/comparison results presented here differ from previous comparison of isotope power (made for Low Earth Orbit (LEO) applications) because of the elevated background temperature on the Martian surface compared to LEO, and the higher sensitivity of dynamic systems to elevated sink temperature. The mass advantage of dynamic systems is significantly reduced for this application due to Mars' elevated background temperature.

Bents, David J.↗