Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hanford Site”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Evaluation of Gaseous Substrates for Microbial Immobilization of Contaminant Mixtures in Unsaturated Subsurface Sediments

Extensive vadose zone metals and organic contamination remains at many former industrial and defense manufacturing sites, and effective remedial solutions are needed to slow or prevent its migration to groundwater. In this study, the application of gaseous substrates to stimulate microbial respiratory reduction of comingled radioisotopes and nitrate under unsaturated conditions was examined for possible application at the Hanford Site, a former nuclear production facility in southeastern WA, USA. First, screening studies were performed to qualitatively measure the sediment respiratory response to 14 gaseous or volatile organic substrates at two moisture contents, 4% and 8%. Volatile substrates produced the strongest respiratory response, among them were butyrate, pentane, butyl acetate. Ethane and butane were the most effective gaseous substrates but only at 8% water content. Hanford sediment from two waste sites with distinctive chemistries were wetted to 7% moisture content, packed into columns, and treated with ethane or butane. After 4 weeks, columns were then leached to quantify retardation in the mobility of aqueous contaminant concentrations compared to no gas control columns. Treatment with both gases resulted in >80% removal of Cr from the aqueous phase. However, NO3 concentration and a waste sites exposure history to NO3 had a major effect on U and Tc reduction. Incomplete nitrate reduction outcompeted U and Tc in waste site sediments having limited prior exposure to NO3. Conversely, waste site sediments co-contaminated with NO3 were able to achieve highly reduced conditions resulting in complete denitrification of NO3, and delayed leaching of U and Tc. This implied effective reduction of both contaminants to less mobile species. This study demonstrates that unsaturated vadose sediments at Hanford waste sites have the capacity for a sustained respiratory response to gaseous substrate injection, which could potentially be deployed as part of an overall strategy to reduce the flux of long-lived radionuclides to groundwater at Hanford and other legacy waste sites.

Bagwell, Christopher E.↗

Development of Property Composition Models For RPP-WTP LAW Glasses (Final Report)

This report describes the development of property-composition models for low-activity waste (LAW) glasses for the River Protection Project Waste Treatment Plant (RPP-WTP) at the Hanford site. The RPP-WTP will separate Hanford tank wastes into LAW and high-level waste (HLW) streams and each stream will be vitrified separately. The development of LAW and HLW glass formulations for the RPP-WTP has been reported previously and is an ongoing activity. Acceptable formulations must meet a variety of processability, product quality, and waste loading requirements that are dictated either by the RPP-WTP contract or by the characteristics of the particular treatment processes that have been selected. These requirements amount to constraints on the acceptable ranges of certain glass properties. These properties are determined first and foremost by the composition of the glass or glass melt. Thus, while there is no direct way of controlling the glass properties of interest during production, there are simple and extremely effective methods of achieving the same result by instead controlling the glass composition. This basic principle is no different from that used to produce enormous volumes of commercial glass to meet exacting product specifications. An essential difference in waste vitrification, however, is that one of the raw materials (the waste itself) can be subject to considerable compositional uncertainty and variability. Thus, waste vitrification facilities and associated process control systems (of which, the operating envelope in glass formulation space is a key part) must, of course, be designed to be robust with respect to such variations. The determination of quantitative relationships between the glass properties that must be controlled and the glass composition can play an important role in the development of such facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Joint Inversion of Surface Electrical Resistivity Tomography and Seismic Refraction Data between the 200 Areas

Geologic stratigraphy on the Hanford Site influences groundwater and contaminant migration through the aquifer system and the vadose zone. The current geologic framework model (GFM) relies heavily on a sparse distribution of borehole data in some locations to map geologic contacts and hydrologic properties in the subsurface. Non-invasive geophysical methods such as electrical resistivity tomography (ERT), transient electromagnetic surveying, and seismic imaging are being used at Hanford to map subsurface structure in areas with limited well observations. This is to develop and mature the capability of geophysical methods to aid in GFM refinement, to identify regions of subsurface complexity, and for optimal well siting. A joint inversion of co-located seismic refraction and ERT data was carried out for data collected on a ~2.3-km profile between the 200 Areas on the Hanford Site. While ERT and seismic refraction images have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different and therefore information can be different or mutually complementary. Performing a joint inversion provides a reasonable option for a coherent, coupled interpretation for mutually complementary datasets. Between the 200 Areas, there are few boreholes to interpret the geologic framework model, and these data sets were obtained to provide a first line of evidence toward identifying stratigraphic structure. The seismic refraction and ERT data were independently inverted during fiscal year 2022 and broadly showed a two-layer structure with a trough-like feature that is ~1 km wide and upwards of 150 m deep. The depth of the trough feature was greater in the ERT image compared to the seismic image, which indicated a maximum depth of approximately 110 m. The objective of the joint inversion described in this report was to invert the seismic refraction and ERT data together while constraining the ERT image to be structurally similar to the seismic refraction image. The approach was applied using the geophysical inverse modeling program E4D, which has the capability to invert first-arrival times from seismic refraction data and ERT resistances using a “cross-gradient” constraint. The application of cross-gradient constraints with different weights produces ERT models that show a high degree of similarity within the upper 100 m (above ~120 m elevation). None of the ERT models show an improved structural similarity to the seismic result; therefore, it is recommended that further attempts to jointly interpret these models focus on petrophysics and image resolution. Petrophysical measurements of core samples would improve knowledge of what drives the ERT response in this region and, along with downhole geophysical measurements, could be used to “ground truth” the surface-based geophysical results. Image resolution studies would provide insight into which regions of the inverted images are reliable and which regions are poorly constrained.

58 GEOSCIENCES↗

The Hanford Lead Canister Collaboration

The Hanford Site, Management of the Cesium and Strontium Capsules (MCSC) Project is preparing to place cesium and strontium material into dry storage using stainless steel canisters that are housed inside vertical concrete casks. Part of the site’s aging management program is to use a spare canister system as a leading indicator canister to provide advance warning for signs of chloride induced stress corrosion cracking (CISCC) or any other kind of canister degradation that might take place over the system’s 300-year design life. The Hanford Lead Canister (HLC) will use electric heaters to simulate the decay heat of cesium and strontium to ensure the HLC simulates the environment and conditions the capsule-loaded systems will experience. In addition to being part of the site’s aging management program, the HLC is being made available for research and development that advances the industry regarding canister mitigation and repair (M&R). The HLC system closely resembles current spent nuclear fuel (SNF) dry storage systems, making the HLC useful for demonstrating technologies or performing research that is relevant to SNF canisters . Several organizations are collaborating to prepare the HLC, along with technical strategy, to perform the needed research and development activities, to include the Pacific Northwest National Laboratory (PNNL), Central Plateau Cleanup Company (CPCCo), and the Electric Power Research Institute (EPRI). In one example of this collaborative research, EPRI is planning to use the HLC to demonstrate in-situ M&R technologies under controlled conditions before the HLC is deployed at Hanford. There is a period of several years when the HLC will be available for canister M&R activity before it is deployed. This paper describes the development of the HLC, its role in the Hanford site’s MCSC Project aging management program, and some of the research activities that are planned for the HLC.

Klymyshyn, Nicholas A.↗

Feasibility of carbon foam-based sorbents for the abatement of gaseous mercury and iodine

The U.S. Department of Energy Hanford Site in Washington State is in the process of commissioning the Waste Treatment and Immobilization Plant to process a portion of the 54 million gallons of radioactive and chemical waste from cold war weapon production. Technologies for the capture of volatile species of concern are still being assessed, and new methods and materials are developed as operational and flowsheet mission risks are identified. One such area still being assessed is the abatement efficacy of the Carbon Adsorber units to retain gaseous mercury and 129 I released during processing. It is challenging to predict the mercury chemistry due to the variability of the feed, and different methods/materials are required for the capture of gaseous Hg 0 and Hg II compounds. In this study, the feasibility of using developmental carbon foam (CF) sorbents for the capture of iodine and mercury was assessed using static and dynamic flow testing and compared against a commercially available sorbent, BATII-37. Both CF and CF functionalized with bismuth particles (CF-Bi) chemisorbed iodine, and CF-Bi had similar mercury capture performance to BATII-37 in dynamic flow tests. While species loading concentrations were measurable, limitations in achieving a mass balance prevented a full evaluation of capture efficacy. Nonetheless, the results serve as an important first step in demonstrating the potential for simultaneous iodine and mercury capture.

Hanford site↗

The dynamic nature of risk in DOE facilities in the surveillance and maintenance program–with observations for risk communications

Here, we explore three case studies of facilities at two US Department of Energy (DOE) former nuclear weapons research and production sites—the Oak Ridge National Laboratory and the Hanford site—whose risk profiles have changed during their long-term management under the DOE's surveillance and maintenance (S&M) program. These case studies provide examples of the challenges faced in communicating to external stakeholders, such as federal and state regulators, local communities surrounding the site, as well as the general public, the circumstances surrounding unexpected events or the emergence/discovery of new risk-important information at historically high-risk sites. We identify common topics of importance from these case studies and suggest a taxonomy for risk communicators to use in informing the dialogues with individuals and organizations that may not be technically oriented or fully informed on the subject matter. The taxonomy is based on technical insights from the quintessential definition of risk known as the Kaplan–Garrick “risk triplet” as well as insights from regulatory guidance documents on risk communication with external stakeholders originally developed for the commercial nuclear power industry.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Surface 3D Electrical Resistivity Tomography Inversion of 2005 BC Cribs and Trenches Datasets

Hydrogeophysics, Inc. (HGI) conducted an electrical resistivity tomography (ERT) dataset at the BC Cribs and Trenches site, located in the Central Plateau of the Hanford Site. The 20 trenches and 6 cribs received large volumes of liquid inorganic waste in the 1950s, resulting in a large inventory of contaminants in the vadose zone. The objective of the ERT survey was to map plume extents resulting from the legacy discharges. The HGI interpretation of the resistivity data was performed using geometric inversion to interpolate 2D lines into a 3D image. To demonstrate a newly developed geophysical code capability (E4D), the resistivity data were re-processed to fit a full 3D model of the bulk electrical conductivity. This proof-of-concept model inversion was executed in calendar year 2011, as the large dataset was well-suited for the use of high-performance computing. The 3D re-processing of the BC Cribs and Trenches ERT data conducted in 2011 resolved the true bulk electrical conductivity. This means that all of the resistivity data were fit to a single model of the bulk electrical conductivity, with true horizontal and vertical dimensions. This differed from the HGI data interpretation approach that used geometric inversion to process 2D lines independently, which were then interpolated into a 3D image. Both the full 3D re-processing and the 2D interpolation to a 3D image demonstrated a higher electrical conductivity observed immediately beneath the trenches and cribs. The electrical conductivity is strongly correlated with nitrate concentrations, indicating the presence of nitrate and other co-located contaminants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Characterization of Cementitious Waste Forms for Immobilization of Granular Activated Carbon, Silver Mordenite, and HEPA Filter Media Solid Secondary Waste

At the Department of Energy’s Hanford site, over 53 million gallons of chemically complex and radioactive wastes have been stored in 177 underground tanks. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is under construction and is designed to treat and immobilize these wastes. During operations of WTP, solid secondary wastes (SSWs) will be generated as a result of waste treatment, vitrification, off-gas management, and supporting process activities. SSW treatment processes and resulting disposal pathways for the final disposition form of the SSW are needed to support direct feed low activity waste (DFLAW) operations and facilitate continued operation of WTP. The SSWs produced through WTP operations are expected to include used process equipment, contaminated tools and instruments, decontamination wastes, high-efficiency particulate air (HEPA) filters, carbon absorption beds (granular activated carbon, GAC), silver mordenite (AgM) and spent ion-exchange resins. These waste streams are planned to be immobilized in a cementitious waste form and disposed of either as stabilized/blended (non-debris) or encapsulated (debris) in a cementitious waste form. Accordingly, cementitious waste forms from these streams were included in the 2017 Integrated Disposal Facility (IDF) Performance Assessment (PA). The input data used to represent these SSW forms in the 2017 IDF PA involved many assumptions and associated uncertainties. This data limitation was due to the lack of material- and site-specific data available for representative SSW materials in cementitious matrices. To verify the assumed values used in the IDF PA and fill this limitation in available data, Washington River Protection Solutions, LLC (WRPS), has initiated a program targeted toward gathering site specific data relevant to Hanford SSW disposal. The work within this report is a continuation of this ongoing program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intern Poster Session 08/13: Autonomous Nuclear Robotics: Applications in nuclear waste inspection and hot cell experiments

The nuclear industry is experiencing renewed interest in autonomous robotics, yet most deployed systems remain teleoperated with limited autonomy. This work presents two contributions toward fully autonomous nuclear robotic systems: autonomous waste inspection at the Hanford Site and an autonomous hot cell laboratory framework. Inspections of Hanford's underground waste storage tanks are performed manually at significant cost and personnel exposure. We developed a reinforcement-learning (RL) training pipeline for a custom-built inspection arm. In parallel, we are designing an autonomous laboratory framework for post-irradiation examination in hot cells at the Specimen Preparation Laboratory (SPL) that integrates computer vision, task and motion planning, hardware execution, and operator-in-the-loop control. These systems demonstrate a path toward safer, more efficient nuclear operations by reducing human exposure while maintaining rigorous human oversight at critical decision points.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ambient airborne solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

Airborne solids concentrations were measured on a near daily basis at two Hanford, Washington sites after the eruption of Mount St. Helens on May 18, 1980. These sites are about 211 km east of Mount St. Helens. Collected airborne solids included resuspended volcanic ash plus normal ambient solids. Average airborne solids concentrations were greater at the Hanford meteorological station sampling site which is 24 km northwest of the Horn Rapids dam sampling site. These increased concentrations reflect the sampling site proximity to greater ash fallout depths. Both sites are in low ash fallout areas although the Hanford meteorological station site is closer to the greater ash fallout areas. Airborne solids concentrations were decreased by rain, but airborne solids concentrations rapidly increased as surfaces dried. Airborne concentrations tended to become nearly the same at both sampling sites only for July 12 and 13.

Sehmel, G. A.↗

Online Analytics for Remedy Support at DOE Environmental Management Sites

Environmental data is important for managing environmental restoration/waste site remediation, planning of monitoring efforts, addressing climate resilience, and engaging with stakeholders and regulators. A major challenge is how to manage the many different types and the large volume of environmental data in a way that allows practitioners and site managers to understand data implications and support decisions. The Suite Of Comprehensive Rapid Analysis Tools for Environmental Sites (SOCRATES, https://www.pnnl.gov/projects/socrates) is a web application that provides data access, visualization, and rapid analytics to help make sense of environmental data, support remedy decisions, and communicate information. Development of SOCRATES has been funded through the DOE Richland Operations Office (RL) to support communication and decision making for the Hanford Site, thus is only tied into Hanford environmental data. However, the capabilities of SOCRATES are more broadly applicable to DOE-EM sites engaged in environmental remediation and management. This report describes the work to develop mechanisms for bringing non-Hanford data into SOCRATES so that other DOE-EM sites could make use of the visualization and analysis capabilities to support communication and decision making related to managing environmental restoration/waste site remediation, optimization/exit strategies for pump-and-treat systems, planning monitoring efforts, addressing climate resilience, and/or engaging with stakeholders and regulators. The background, approach, data transfer formats, examples, and next steps for this new SOCRATES-EM software are described in this report.

54 ENVIRONMENTAL SCIENCES↗

Integrating Analytical Solutions and U-Net Model for Predicting Groundwater Contaminant Plumes in Pump-and-Treat Systems

Pump-and-treat (P&T) is a common technique for groundwater remediation involving the extraction and treatment of contaminated water above ground. Optimizing the design and operation of the P&T well network is essential for maximizing the system’s effectiveness and efficiency. However, this optimization often necessitates many model evaluations, leading to computationally demanding tasks. This study introduces a novel approach that integrates analytical solutions for groundwater dynamics with the U-Net (Ronneberger et al., 2015) deep learning framework to predict groundwater contaminant plume migration under dynamic pumping conditions. By incorporating the Thiem equation (Thiem, 1906) into the input preprocessing, the U-Net model transforms sparse well data into a continuous spatial field that captures the hydraulic impacts of pumping activities. This integration enables the model to leverage both deep learning capabilities and classical physics-based groundwater theories, enhancing prediction accuracy and computational efficiency. These advancements can facilitate rapid, large-scale evaluations of P&T optimization simulations, allowing for timely and effective decision-making in well placement and system management. We demonstrate the model's robust performance across both simplified transient 2D models and a more complex 3D heterogeneous site model at the 200 West P&T facility at the Hanford Site. The U-Net-based model offers substantial computational advantages, reducing simulation times significantly compared to full physics-based models and providing a powerful tool for rapid site evaluation and P&T system optimization, such as evaluating alternative P&T well network designs. Our findings highlight the potential of advanced machine learning models to significantly enhance the efficiency and sustainability of groundwater remediation efforts, offering a novel application of U-Net architecture in environmental science.

Pump-and-treat↗

Hanford Tank Vapors in Worker Breathing Zones - Source, Dispersion, and Receptor Data - 20373

A wide range of organic and inorganic chemicals from historical Hanford Site processes are now stored in 177 underground storage tanks at the Hanford tank farms. Workers at the Hanford tank farms have expressed concerns about chemical vapor exposures for many years. During the spring of 2014, worker reports of chemical odors and/or symptoms prompted the development of the Savannah River National Laboratory Hanford Tank Vapor Assessment Team (TVAT) and their resulting independent assessment and recommendations concerning tank farm worker reports of vapors. The Tank Vapor Assessment report included a hypothesis that 'vapors coming out of tanks in high concentration (bolus) plumes sporadically intersected with the breathing zones of workers, resulting in brief but intense exposures to some workers.' The focus of this effort is to present current knowledge to describe the mechanisms by which workers may experience short duration vapor concentrations above background in the tank farms environment. The TVAT hypothesis that workers have experienced concentrations approaching 80% of the tank headspace up to 3 meters (10 feet) from tank sources is not supported by sampling data or modeling results. Modeling indicates that concentrations are quickly reduced from the source, and that the upper end of predicted concentrations at worker breathing zones are a factor of 10 or more lower than source concentrations. Area measurements corroborate the fact that worker breathing zone concentrations are 10 to 100 times lower than source concentrations, and events with elevated concentrations are rare. These reduced vapor concentration levels may result in detectable odors or irritation, depending on a worker's specific odor threshold and sensitivity to the chemical species. Short-duration vapor events may be mitigated by evaluating daily atmospheric conditions in conjunction with planned tank farm activities. Monitoring changing conditions related to tank vapors concentrations at the source and within worker breathing zone is also an important step to protect workers from short duration elevated concentration events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 26: Risk-Based Approaches to Environmental Remediation and Adaptive Site Management

This panel discussed the needs and importance of developing risk-based approaches to environmental remediation that will enable complex sites to be adaptively managed by applying cost-effective remedies that are protective of human health and the environment. The discussion emphasized risk-based approaches within decision processes and subsequent incorporation into regulatory decision documents. Remedy approaches, remediation exit strategies, and long-term monitoring plans that support risk-based end-states for difficult-to-remediate sites were discussed Panelists with presentations: Risk-Informed Approaches to Environmental Remediation and Adaptive Site Management (Vicky Freedman); ITRC Adaptive Site Management Perspective (Michael Truex); Optimization During Operations and Maintenance Phase at the Hanford Site 200-ZP-1 Groundwater Operable Unit (Emerald Laija, Kate Amrhein, Michael Truex); Adaptive Management: EPA Overview (Benjamin Simes); Decommissioning and Environmental Remediation Section Division of Nuclear Fuel Cycle and Waste Technology (Horst Monken Fernandes)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ precipitation of hydrous ferric oxide (HFO) for remediation of subsurface iodine contamination

A practical approach for in-situ hydrous ferric oxide (HFO) precipitation was developed for iodine immobilization under field-scale conditions at the Hanford Site. A series of 1D meter-long bench top column experiments packed with Hanford sediments was conducted with a single acidic ferric solution (0.1 M, pH = 1.5) injection. Because carbonate and clay minerals are widely present in sediments, self-pH buffering of the injected acidic ferric solution occurred due to mineral dissolution, leading to HFO precipitation under a neutral condition. Up to ~12 mg/g HFO successfully precipitated and evenly distributed in the column sediments, and the remobilization of the neo-formed HFO precipitates was limited (< 4 wt.% after 100 pore volumes of flushing). The transport of IO3- in the HFO-amended sediments was strongly retarded through both adsorption and co-precipitation processes. However, reversible adsorption of iodine on HFO was observed, which might limit its application to slow moving groundwater systems.

Wang, Guohui↗

Strontium Speciation in Relevant Tank Waste Components Examined by Electrospray Ionization Mass Spectrometry

The identification of chemical species formed in complex nuclear waste is crucial for the development and employment of advanced separations technologies to remediate the Hanford site by processing tank waste. The current Tank Side Cesium Removal (TSCR) process deployed at Hanford utilizes crystalline silicotitanate (CST) ion exchange (IX) media to aid in the separation of low-activity waste for proper treatment and disposal. The inorganic IX media is highly selective for Cs but has been shown to also remove Sr from caustic simulants and small-scale IX processing of Hanford tank waste.(Fiskum, Rovira et al. 2019, Fiskum, Campbell et al. 2021, Westesen, Campbell et al. 2022) Quantitative Sr removal has not been observed in all tank waste supernates tested; thus, to better understand Sr removal and effectively predict processing behavior through TSCR, it is necessary to first investigate Sr speciation in tank waste. This work utilized electrospray ionization mass spectrometry (ESI-MS) to identify ionic Sr complexes that form in the presence of NO 3 –, NO 2 –, OH–, and Cl–. Although our results show that NO 3 –, NO 2 –, and OH– are competitive for Sr 2+ binding, previous data from IX studies indicate that [SrOH] + is not the dominant species of concern in tank waste processing schemes.(Fiskum, Campbell and Trang-Le 2020) Our results show that the [Sr(NO3)]+ species and the [Sr(NO2)] + species form in considerable abundances, which may affect the ability to separate Sr using CST in nuclear waste separation processes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗