Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid

In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude. Since most substations are unmanned and have limited physical security protection, cyber breaches into power grid substations present a risk. Nowadays, the susceptibility of SDN architecture to cyber-attacks has exhibited a notable increase in recent years, as indicated by research findings. This suggests a growing concern regarding the potential for cybersecurity breaches within the SDN framework. In this paper, we propose a hybrid intrusion detection system (IDS)-integrated SDN architecture for detecting and preventing the injection of malicious IEC 61850-based generic object-oriented system event (GOOSE) messages in a digital substation. Additionally, this program locates the fault’s location and, as a form of mitigation, disables a certain port. Furthermore, implementation examples are demonstrated and verified using a hardware-in-the-loop (HIL) testbed that mimics the functioning of a digital substation.

Liu, Chen-Ching [Virginia Tech] (ORCID:00000002894↗

Cyber Physical Grid-Interactive Distributed Energy Resources Control for VPP Dispatch and Regulation

This paper presents a cyber-physical algorithm for grid-interactive Distributed Energy Resource (DER) control to enable two features of Virtual Power Plants (VPPs) dispatch and grid voltage regulation, considering the communication and security impacts. We first formulate the DER dispatch problem as a real-time, iterative, and grid-interactive DER control problem. Thereafter, we consider a probabilistic traffic model to characterize packet delays and loss in a communication network, and study how the delays enter the process of information exchange among the grid measurement units, local DER controllers and the grid control center that coordinately execute this dispatch algorithm. Finally, a strategy combining delay threshold and modified message update rules is proposed to immune the asynchrony resulting from the communications network traffic and it avoids possible numerical instabilities and sensitivities of the tracking and regulation capabilities of this DER control algorithm. By implementing the proposed cyber-physical algorithm on the modified IEEE 37-node system, our preliminary results exhibit that the uncertainties of the underlying communications infrastructure must be considered for the VPP tracking and regulation capabilities of any DER in a generic Cyber-Physical System (CPS), because the delayed voltage measurements in the uplink/bi-link cases result in the off-track in VPP dispatch and jittery in voltage regulation.

cyber-physical algorithm↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - Asimily Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator (TM) (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Physical Grid-Interactive Distributed Energy Resources Control for VPP Dispatch and Regulation: Preprint

This paper presents a cyber-physical algorithm for grid interactive DER control to enable two features of Virtual Power Plants (VPPs) dispatch and grid voltage regulation, considering the communication and security impacts. We first formulate the DER dispatch problem as a real-time, iterative, and grid-interactive DER control problem. Thereafter, we consider a probabilistic traffic model to characterize packet delays and loss in a communication network, and study how the delays enter the process of information exchange among the grid measurement units, local DER controllers and the grid control center that coordinately execute this dispatch algorithm. Finally, we propose a cyber-physical grid-interactive DER control algorithm using the previous message strategy. The tracking and regulation capabilities of this proposed algorithm can be made immune to the asynchrony resulting from the communications network traffic. We carry out simulations to show possible numerical instabilities and sensitivities of the tracking and regulation capabilities on the proposed strategy. Our results exhibit that the uncertainties of the underlying communications infrastructure must be considered in the control algorithm for the VPP tracking and regulation capabilities of any DER in a generic Cyber-Physical System (CPS).

co-simulation↗

Progress and prospects of thermo-mechanical energy storage – A critical review

The share of electricity generated by intermittent renewable energy sources is increasing (now at 26% of global electricity generation) and the requirements of affordable, reliable and secure energy supply designate grid-scale storage as an imperative component of most energy transition pathways. The most widely deployed bulk energy storage solution is pumped-hydro energy storage (PHES), however, this technology is geographically constrained. Alternatively, flow batteries are location independent and have higher energy densities than PHES, but remain associated with high costs and low lifetimes, which highlights the importance of developing and utilizing additional larger-scale, longer-duration and long-lifetime energy storage alternatives. Here, we review a class of promising bulk energy storage technologies based on thermo-mechanical principles, which includes: compressed-air energy storage (CAES), liquid-air energy storage (LAES) and pumped-thermal electricity storage (PTES). The thermodynamic principles upon which these thermo-mechanical energy storage (TMES) technologies are based are discussed and a synopsis of recent progress in their development is presented, assessing their ability to provide reliable and cost-effective solutions. The current performance and future prospects of TMES systems are examined within a unified framework and a thermoeconomic analysis is conducted to explore their competitiveness relative to each other as well as when compared to PHES and flow battery systems. This includes carefully selected thermodynamic and economic methodologies for estimating the component costs of each configuration in order to provide a detailed and fair comparison at various system sizes. The analysis reveals that the technical and economic characteristics of TMES systems are such that, especially at higher discharge power ratings and longer discharge durations, they can offer promising performance (round-trip efficiencies higher than 60%) along with high lifetimes (> 30 years), low specific costs (often below 100 $/kWh), low ecological footprints and unique sector-coupling features compared to other storage options. TMES systems have significant potential for further progress and the thermoeconomic comparisons in this paper can be used as a benchmark for their future evolution.

25 ENERGY STORAGE↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

Modeling Failure of Electrical Transformers due to Effects of a HEMP Event

Understanding the effect of a high-altitude electromagnetic pulse (HEMP) on the equipment in the United States electrical power grid is important to national security. A present challenge to this understanding is evaluating the vulnerability of transformers to a HEMP. Evaluating vulnerability by direct testing is cost-prohibitive, due to the wide variation in transformers, their high cost, and the large number of tests required to establish vulnerability with confidence. Alternatively, material and component testing can be performed to quantify a model for transformer failure, and the model can be used to assess vulnerability of a wide variety of transformers. This project develops a model of the probability of equipment failure due to effects of a HEMP. Potential failure modes are cataloged, and a model structure is presented which can be quantified by the results of small-scale coupon tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Utility Data Exchange (UUDEX) Functional Design Requirements - Rev 1

This document provides a set of high-level functional design requirements for Universal Utility Data Exchange (UUDEX). These requirements include a set of use cases, data exchanges supported by UUDEX, both for grid operations and for cyber security data, functional requirements for data exchange, data models used by UUDEX, data exchange architectures, and security considerations. These functional design requirements are intended to be used in more detailed design documents.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Feasibility of Utilizing a Low-Cost UWB Radar for Hardware Implant & Counterfeit Device Detection

Hardware implants & counterfeit devices in the US power grid pose a significant national security threat. Asset owners currently have few options for detecting the presence of such devices “in the wild”. The goal of this work is to develop a non-invasive sensing method to solve this problem. In this work we evaluate the feasibility of implementing a nonlinear UWB radar tomography system to differentiate between electronic internals of externally-similar devices using low-cost off-the-shelf hardware.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydropower Cybersecurity Value-at-Risk Framework

Hydropower remains one of the strongest forms of renewable energy generation methods. It is crucial to address the increasing risks associated with the rapid digitization. The push towards decarbonization also factors in the need to ensure security and resilience for grid-connected renewable energy resources. This report summarizes the U.S. Department of Energy's Water Power Technologies Office's effort to develop a cybersecurity valuation methodology that assists hydropower stakeholders in assessing risks associated with plan operations and gathers valuation guidance through a web-based application. The Hydropower Cybersecurity Value-at-Risk Framework delivers a platform for industry members to perform self-assessments and make informed decisions on their cybersecurity investments.

13 HYDRO ENERGY↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

The Cybersecurity Value-at-Risk Framework

Hydropower remains one of the strongest forms of renewable energy generation methods. It is crucial to address the increasing risks associated with the rapid digitization. The push towards decarbonization also factors in the need to ensure security and resilience for grid-connected renewable energy resources. This report summarizes the U.S. Department of Energy's Water Power Technologies Office's effort to develop a cybersecurity valuation methodology that assists hydropower stakeholders in assessing risks associated with plan operations and gathers valuation guidance through a web-based applicaiton. The Hydropower Cybersecurity Value-at-Risk Framework delivers a platform for industry members to perform self assessments and make informed decisions on their cybersecurity investments.

CVF↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Securing Digital Energy Infrastructure: Procurement, Contracting, and Supply Chain Risk Management Guidance

Recognizing the scale of this industry challenge, the United States (U.S.) Department of Energy (DOE) Grid Deployment Office (GDO) and Cybersecurity Energy Security & Emergency Response office have launched a multi-year BESS supply chain security initiative to identify consequence-driven approaches to addressing BESS supply chain security and provide resources to support prioritization of supply chain security efforts associated with the procurement of BESS equipment and services. This guide is one element of the supporting resources to be provided and sets forth a framework and guidance for procurement bidding, selection, risk analysis, and agreements stakeholders can implement to mitigate cybersecurity risks across the entirety of battery system component ecosystem, including the interconnected software and hardware required for control and monitoring BESSs.

25 ENERGY STORAGE↗

Developing a Distributed Trust Model for Distributed Energy Resources

Electric power system operators can manage distribution system reliability by coordinating end customer usage of distributed energy resources. The end customers in this regard are Service Provisioning Customers, who provide their energy resources to a Grid Service Provider, which in turn dispatches large aggregations of distributed energy resources to provide reliable service to the power system.The security of this system relies upon information protection mechanisms, as described in IEEE 2030.5. However, in addition to preventive security measures, a monitoring function is required to ensure trustworthiness. Trust models are a method to detect and respond to both expected and unexpected behavior. Different trust models are required for various types and characteristics of each situation. This paper will describe the topics that must be considered when developing a trust model as it applies to distributed energy resources. The major contribution of this paper is the creation and application of a Distributed Trust Model applied to distributed energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗