Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Adaptation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Integrating Data Centers and Grid Technologies at Scale

This presentation focuses on the challenge of integrating AI-driven data centers with the power grid at scale. It examines the AI data center capacity challenge and the role of new Medium Voltage Direct Current (MVDC) and other grid-enhancing technologies in enabling efficient and reliable power delivery. The session will highlight the National Laboratory of the Rockies' ARIES capabilities and planning tools, along with collaborative examples involving Verrus, Compass, and Schneider through the Agora test bed for grid-friendly data center evaluations, and ON. Energy for UPS evaluation. It will showcase the NLR Stable Grid Platform for studying oscillations caused by large-scale data centers, along with planning tools to assess grid security and reliability. Additionally, the presentation covers reconductoring strategies to increase grid capacity and explores innovative data center architectures, including the Advanced DC Architectures with Power-electronic Transformers (ADAPT) platform, which enables testing of complete DC architectures for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global field reconstruction from sparse sensors with Veronoi tessellation-assisted deep learning

Achieving accurate and robust global situational awareness of a complex time-evolving field from a limited number of sensors has been a longstanding challenge. This reconstruction problem is especially difficult when sensors are sparsely positioned in a seemingly random or unorganized manner, which is often encountered in a range of scientific and engineering problems. Moreover, these sensors can be in motion and can become online or offline over time. The key leverage in addressing this scientific issue is the wealth of data accumulated from the sensors. As a solution to this problem, we propose a data-driven spatial field recovery technique founded on a structured grid-based deep-learning approach for arbitrary positioned sensors of any numbers. It should be noted that the naïve use of machine learning becomes prohibitively expensive for global field reconstruction and is furthermore not adaptable to an arbitrary number of sensors. In the present work, we consider the use of Voronoi tessellation to obtain a structured-grid representation from sensor locations enabling the computationally tractable use of convolutional neural networks. One of the central features of the present method is its compatibility with deep-learning based super-resolution reconstruction techniques for structured sensor data that are established for image processing. The proposed reconstruction technique is demonstrated for unsteady wake flow, geophysical data, and three-dimensional turbulence. The current framework is able to handle an arbitrary number of moving sensors, and thereby overcomes a major limitation with existing reconstruction methods. The presented technique opens a new pathway towards the practical use of neural networks for real-time global field estimation.

Fukami, Kai↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

An Orbital Basis Set for Double Photoionization of Atoms and Molecules

The ab initio theoretical treatment of one-photon double photoionization processes has been limited to atoms and diatomic molecules by the challenges posed by large grid-based representations of the double ionized continuum wave function. To provide a path for extensions to polyatomics, an energy-adapted orbital basis approach is demonstrated that reduces the dimensions of such representations and simultaneously allows larger time steps in time-dependent computational descriptions of double ionization. Additionally, an algorithm that exploits the diagonal nature of the two-electron integrals in the grid basis and dramatically accelerates the transformation between grid and orbital representations is presented. Excellent agreement between the present results and benchmark theoretical calculations is found for H – and Be atoms, as well as the hydrogen molecule, including for the triply differential cross sections that relate the angular distribution and energy sharing of all of the particles in the molecular frame.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Two-Phase Turbulence Statistics from High Fidelity Dispersed Droplet Flow Simulations in a Pressurized Water Reactor (PWR) Sub-Channel with Mixing Vanes

In the dispersed flow film boiling regime (DFFB), which exists under post-LOCA (loss-of-coolant accident) conditions in pressurized water reactors (PWRs), there is a complex interplay between droplet dynamics and turbulence in the surrounding steam. Experiments have accredited particular significance to droplet collision with the spacer-grids and mixing vane structures and their consequent positive feedback to the heat transfer recorded in the immediate downstream vicinity. Enabled by high-performance computing (HPC) systems and a massively parallel finite element-based flow solver—PHASTA (Parallel Hierarchic Adaptive Stabilized Transient Analysis)—this work presents high fidelity interface capturing, two-phase, adiabatic simulations in a PWR sub-channel with spacer grids and mixing vanes. Selected flow conditions for the simulations are informed by the experimental data found in the literature, including the steam Reynolds number and collision Weber number (Wec={40,80}), and are characteristic of the DFFB regime. Data were collected from the simulations at an unprecedented resolution, which provides detailed insights into the continuous phase turbulence statistics, highlighting the effects of the presence of droplets and the comparative effect of different Weber numbers on turbulence in the surrounding steam. Further, axial evolution of droplet dynamics was analyzed through cross-sectionally averaged quantities, including droplet volume, surface area and Sauter mean diameter (SMD). The downstream SMD values agree well with the existing empirical correlations for the selected range of Wec. The high-resolution data repository from the simulations herein is expected to be of significance to guide model development for system-level thermal hydraulic codes.

Saini, Nadish↗

Challenges and Opportunities for Electric Utility Modeling and Asset Valuation Frameworks: Case Study on Valuing New Pumped Storage Hydropower

Asset valuation by electric utilities is becoming increasingly difficult in the rapidly changing electric sector. Rapid deployment of variable generation and inverter-based storage systems along with uncertain demand growth, climate, policies, and other factors create a challenging environment for understanding the value proposition of a new potential asset. This report describes an effort between the Tennessee Valley Authority (TVA) and three U.S. Department of Energy laboratories to perform a detailed review of utility modeling and analysis practices for asset valuation and identify challenges and opportunities for advancing its methods into the future. It focuses on a case study of new potential pumped storage hydropower (PSH) because of growing interest in new PSH capacity to provide energy balancing, firm capacity, and a range of ancillary services. Staff from the DOE labs conducted systematic interviews about current practices in capacity expansion modeling, production-cost modeling, hydrological modeling, and transmission stability modeling while also discussing how scenario analysis is conducted and how models and data are integrated. The effort resulted in a set of model, integration, and scenario recommendations that could be valuable to TVA, other utilities, system operators, and other stakeholders conducting integrated grid analysis. Individual model recommendations suggest exploring computational tradeoffs with detail and resolution across spatiotemporal structure, supply- and demand-side details, transmission overlays, market interactions, and ancillary services. Automated processes to pass data between models and conduct larger scenario suites could also enhance valuation practices by enabling a more consistent study of asset value across a broader range of uncertain future grid conditions where PSH could be particularly valuable. TVA and other industry stakeholders can learn from and adapt applied research-grade methods developed by DOE laboratories and other research institutions to improve decision making and accelerate progress towards a reliable, economic, sustainable energy system.

13 HYDRO ENERGY↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

A projection method for particle resampling

Particle discretizations of partial differential equations are advantageous for high-dimensional kinetic models in phase-space due to their better scalability than continuum approaches with respect to dimension. Complex processes collectively referred to as particle noise hamper long time simulations with particle methods. One approach to address this problem is particle mesh adaptivity, or remapping, known as particle resampling and remeshing. Here, this work introduces a resampling method that projects particles to and from a (finite element) function space. The method is simple, using standard sparse linear algebra and finite element techniques, and it preserves all moments up to the order of a polynomial represented exactly by the continuum function space. It is distinguished from most other mesh-based methods in that new particle positions and number are decoupled from the mesh, allowing particle and continuum meshes to be adapted relatively independently. While this work is developed with structured particle and continuum phase-space grids on 1X + 1V Vlasov-Poisson models of Landau damping and two-stream instability, the method is well-suited to unstructured grids. Stable long time dynamics are demonstrated up to time T = 500. Reproducibility artifacts and data are publicly available.

Kinetic methods↗

Energy, economic, and environmental tradeoffs at run-of-river hydropower facilities

Hydropower’s ability to quickly adapt to variability from wind and solar generation by fluctuation flow rates can allow the electricity grid to integrate more renewable capacity. However, these rapid flow fluctuations, required to meet variability needs, can negatively impact aquatic ecosystems. In this study, we quantified energy-economic-environment tradeoffs at five conventional hydropower facilities (i.e. hydropower produced ad a dam on a river channel) across the United States to identify a mix of operational regimes that can provide flexibility to support variable renewable energy integration and environmental protections. Model results show a range of ability to meet demand from 4.7% to 97.8% depending on which case study is considered. Additionally, when modeling the case study facilities on a range of RoR conditions, allowing a % of inflow as discharge, we found the range of 140–200% of inflow allowed as discharge lead to lowest environmental impact while meeting the highest amount of demand. Our sensitivity analysis results demonstrated the Richard-Baker Flashiness Index, used to measure flowrate changes, and Revenue, were negatively correlated with the percent of hydropower generation within the defined Regional Energy Deployment System balancing area (i.e. region in which energy demand and energy supply is balanced based on the Regional Energy Deployment System model) yet positively correlated to the variable renewable energy generation percentage in the defined balancing area. In conclusion, our results suggest hydropower operations can aid in increasing renewable energy generation while limiting environmental impacts when considering a holistic analysis of energy-economic-environment tradeoffs.

Economic impact↗

Onslow Beach Washover Fan Morphology from 2012 to 2015

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of encroachment pressures in surrounding areas, impairments due to other anthropogenic disturbances, and changes in climate and sea level. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and also optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the second 5 years of the program (DCERP2) are presented in the DCERP2 Final Report.There were four overarching objectives of DCERP2. The first objective was to understand the effects of climate change impacts, including warming temperatures, variability in the hydrological cycle, storm events, and sea level rise on the coastal ecosystems at MCBCL from observations and measurements made over the 10-year program. The second objective was to understand the carbon cycle of the coastal and terrestrial ecosystems at MCBCL through a highly integrated sampling program. The third objective was to develop models, tools, and indicators to evaluate current and projected future ecosystem state changes and translate scientific findings into actionable information for installation managers. The last objective was to recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.These grid files were created from data collected using a Riegl 3-D laser scanner. Millions of x, y, and z points from the F2 Washover Fan on Onslow Beach were processed using the MARS software package to define a bare-earth model. Grid files were imported into Golden Software Surfer version 19 for editing and exported from that application as .grd files. Files can be opened in Surfer or ArcMap, but the coordinate system information will be lost if opened in ArcMap. These data were collected to quantify the morphological changes that occur on a washover fan through time.

54 ENVIRONMENTAL SCIENCES↗