Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geologic carbon storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Storage Field Development Plan: One Earth Energy

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, and operational plans, and costs associated with the proposed One Earth Sequestration Carbon Capture and Storage (OES-CCS) site in McLean County, Illinois, near Gibson City. The proposed storage complex, known as the Mt. Simon Storage Complex, comprises the Cambrian Mt. Simon Sandstone reservoir and the primary seal, the Cambrian Eau Claire Formation. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Ordovician St. Peter Sandstone. Geologic characterization of the Mt. Simon Storage Complex at the OES-CCS site was performed by the Illinois Storage Corridor CarbonSAFE Phase III project, which also prepared and submitted three UIC Class VI applications to construct three injection wells; the permit applications were submitted and are in the federal EPA review process. A characterization well, OEE #1, was drilled to collect site-specific data. These data were analyzed and used to develop the UIC Class VI applications. The OEE #1 well will be converted to an in-zone monitoring (IZM) well for the injection phase. The proposed buildout for the OES-CCS site includes (1) three injection wells (OES #1, OES #2, and OES #3), (2) two IZM wells, (3) two above confining zone (ACZ) monitoring wells, one of which will be used to monitor the lowermost USDW, (4) capture and compression facilities, and (5) transportation facilities, i.e., pipelines. A pre-operational testing program was proposed in the Class VI permit application and will be employed at the site pending approval. Additional pre-injection (baseline), syn-injection, and post-injection monitoring and site care procedures will be followed by OES to ensure that injection activities are protective of human health and the environment. Injection is scheduled to begin in 2025, distributed across the three injection wells in accordance with the permit operating conditions. One Earth Sequestration intends to inject up to 90 million tonnes of CO 2 over a period of approximately 20 years. Injection will begin at approximately 0.5 million tonnes of CO 2 annually and ramp up to a maximum of 4.5 million tonnes annually. Daily injection rates are expected to range from 1,400 to 1,500 tonnes per day initially and reach a maximum of approximately 4,225 tonnes per day, depending on site geology and injectivity at each injection well location, and CO 2 availability. The costs associated with the OES-CCS project include pre-operational costs (e. g. additional seismic data acquisition and well drilling), capture and transportation facility and equipment costs, predicted field operating expenditures (OpEx), and decommissioning and post-injection site care (PISC) costs. The risks associated with project activities, such as site construction, injection operations, and verification of secure storage were evaluated, and mitigation strategies proposed to alleviate those risks.

09 BIOMASS FUELS↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Numerical Modeling of Anisotropic Elastic-Wave Sensitivity Propagation for Optimal Design of Time-Lapse Seismic Surveys

Reliable subsurface time-lapse seismic monitoring is crucial for many geophysical applications, such as enhanced geothermal system characterization, geologic carbon utilization and storage, and conventional and unconventional oil/gas reservoir characterization, etc. In this work, we develop an elastic-wave sensitivity propagation method for optimal design of cost-effective time-lapse seismic surveys considering the fact that most of subsurface geologic layers and fractured reservoirs are anisotropic instead of isotropic. For anisotropic media, we define monitoring criteria using qP- and qS-wave sensitivity energies after decomposing qP- and qS-wave components from the total elastic-wave sensitivity wavefield using a hybrid time- and frequency-domain approach. Geophones should therefore be placed at locations with significant qP- and qS-wave sensitivity energies for cost-effective time-lapse seismic monitoring in an anisotropic geology setting. Our numerical modeling results for a modified anisotropic Hess model demonstrate that, compared with the isotropic case, subsurface anisotropy changes the spatial distributions of elastic-wave sensitivity energies. Consequently, it is necessary to consider subsurface anisotropies when designing the spatial distribution of geophones for cost-effective time-lapse seismic monitoring. This finding suggests that it is essential to use our new anisotropic elastic-wave sensitivity modeling method for optimal design of time-lapse seismic surveys to reliably monitor the changes in subsurface reservoirs, fracture zones or target monitoring regions.

97 MATHEMATICS AND COMPUTING↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Climate vs Energy Security: Quantifying the Trade-offs of BECCS Deployment and Overcoming Opportunity Costs on Set-Aside Land

Bioenergy with carbon capture and storage (BECCS) sits at the nexus of the climate and energy security. We evaluated trade-offs between scenarios that support climate stabilization (negative emissions and net climate benefit) or energy security (ethanol production). Our spatially explicit model indicates that the foregone climate benefit from abandoned cropland (opportunity cost) increased carbon emissions per unit of energy produced by 14–36%, making geologic carbon capture and storage necessary to achieve negative emissions from any given energy crop. The toll of opportunity costs on the climate benefit of BECCS from set-aside land was offset through the spatial allocation of crops based on their individual biophysical constraints. Dedicated energy crops consistently outperformed mixed grasslands. We estimate that BECCS allocation to land enrolled in the Conservation Reserve Program (CRP) could capture up to 9 Tg C year –1 from the atmosphere, deliver up to 16 Tg CE year –1 in emissions savings, and meet up to 10% of the US energy statutory targets, but contributions varied substantially as the priority shifted from climate stabilization to energy provision. Furthermore, our results indicate a significant potential to integrate energy security targets into sustainable pathways to climate stabilization but underpin the trade-offs of divergent policy-driven agendas.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data for Climate vs Energy Security: Quantifying the Trade-offs of BECCS Deployment and Overcoming Opportunity Costs on Set-Aside Land

Bioenergy with carbon capture and storage (BECCS) sits at the nexus of the climate and energy security. We evaluated trade-offs between scenarios that support climate stabilization (negative emissions and net climate benefit) or energy security (ethanol production). Our spatially explicit model indicates that the foregone climate benefit from abandoned cropland (opportunity cost) increased carbon emissions per unit of energy produced by 14–36%, making geologic carbon capture and storage necessary to achieve negative emissions from any given energy crop. The toll of opportunity costs on the climate benefit of BECCS from set-aside land was offset through the spatial allocation of crops based on their individual biophysical constraints. Dedicated energy crops consistently outperformed mixed grasslands. We estimate that BECCS allocation to land enrolled in the Conservation Reserve Program (CRP) could capture up to 9 Tg C year–1 from the atmosphere, deliver up to 16 Tg CE year–1 in emissions savings, and meet up to 10% of the US energy statutory targets, but contributions varied substantially as the priority shifted from climate stabilization to energy provision. Our results indicate a significant potential to integrate energy security targets into sustainable pathways to climate stabilization but underpin the trade-offs of divergent policy-driven agendas.

Field Data↗

Caprock Remains Water Wet Under Geologic CO 2 Storage Conditions

Abstract Carbon storage technology is primarily targeted in saline formations, which is a porous rock matrix filled with brine, sealed with a low permeability caprock. There are significant variations of CO 2 wetting properties, typically reported in the literature as contact angle of CO 2 and brine interacting with a rock material, suggesting that CO 2 could become wetting under geostorage conditions and negatively impact containment effectiveness. Here, we performed the first controlled laboratory measurements of CO 2 ‐brine contact angles on shale rocks from low permeability sealing formations with distinctive mineralogic properties—calcite‐rich, quartz‐rich, and dolomite‐rich. We targeted temperatures at 40° and 100°C, pressures at 8.3, 34.5, and 62.1 MPa, and salinity at 35,000 and 260,000 ppm. Results show no significant change in contact angle with mineralogy, temperature, pressure, salinity, and CO 2 bubble size. We conclude that caprocks will remain water‐wet at geologic CO 2 storage conditions and will not lose their capillary sealing capacity.

Tapriyal, Deepak↗

Facies Analysis and Depositional Environments of the Upper Cambrian Eau Claire Formation in Central and Northern Illinois

The Cambrian Eau Claire Formation is a confining unit for geologic carbon dioxide (CO2) storage, and potentially a confining unit for hydrogen storage, within the underlying Mount Simon Sandstone in the Central and Northern Illinois Basin. However, extensive regional studies on lateral continuity, environment of deposition, and depositional fabric of the Eau Claire Formation in the Illinois Basin are minimal compared to studies of the underlying Mount Simon Sandstone. This study presents an integrated facies analysis using sedimentological, stratigraphic, ichnological, and mineralogical data to interpret the depositional environments of the Eau Claire Formation, emphasizing the dynamic nature of sedimentary systems. By combining core analyses, thin-section analysis, facies interpretation from geophysical logs, and regional stratigraphic framework interpretation, this work provides insights into the integrated depositional framework across diverse depositional environments. These findings suggest that the Eau Claire Formation in the Central and Northern Illinois Basin was deposited in a shallow marine environment, ranging from tidal flats to offshore settings. Its mixed siliciclastic-carbonate succession was primarily controlled by relative sea-level change.

58 GEOSCIENCES↗

Minimizing exposure to legacy wells and avoiding conflict between storage projects: Exploring area of review as a screening tool

Elevated pressure from large-volume injection is a key driver of risk and project cost. If transmissive features (e.g., non-isolating wells or fracture systems) are present, increased injection-zone pressure can drive fluids from depth toward protected freshwater resources. In US Carbon Capture and Storage (CCS) law, the area at risk is known as the Area of Review (AoR). The size and number of potentially transmissive features to be evaluated and possibly remediated or managed is a function of the size and location of the AoR. The size of the AoR depends on several variables, including properties of the injection zone, properties of protected resources, and injection rate and duration. Evaluation of the intersection of these variables across a portfolio of sites highlights the injection zone depth and boundary conditions as top-level controls. Deep injection, use of multiple stacked injection zones, reduced injection rate and choice of injection well location can all be used to minimize AoR and the number of potentially transmissive features within it. Here, we introduce the concept of pressure space (defined as connected pore volume times pressure) as the key subsurface commodity for CO 2 storage and we suggest that it forms a more robust basis for leasing and regulation than pore space alone.

58 GEOSCIENCES↗

Nonequilibrium Physics of Multiphase Flow in Porous Media: Wettability and Disorder

Carbon capture and geologic storage, dissociation of methane hydrates in permafrost, enhanced oil recovery, and water dropout in low-temperature fuel cells, all have something in common: two or more fluids flow simultaneously through a porous medium; and the displacement of one fluid by another is often unstable (either due to gravity or viscous forces). Yet, our ability to model multiphase flow in porous media has remained a challenge. The traditional equations are unable to predict, explain, or even reproduce, the formation of the complex patterns observed in experiments. The overarching goal of the project is to develop new physical understanding of the role of wettability and disorder in multiphase flow through permeable media, and to develop new mathematical and computational models at the pore scale and at the continuum scale.

58 GEOSCIENCES↗

EFRC-MUSE: Multi-Scale Fluid-Solid Interactions in Architected and Natural Materials

Phase interactions and fluid properties in geological and other environments are critical in applications ranging from hydrogen production and geologic storage and recovery, carbon dioxide storage and sequestration, and the sustainable use of water resources. The four goals of EFRC-MUSE: Multi-Scale Fluid-Solid Interactions in Architected and Natural Materials were based on the priority directions articulated in the Basic Research Needs documents, and the scientific needs in nanoscience. 1. Develop a fundamental understanding of confinement and surface interactions in mesoscale media with nanometer-sized pores on the phase behavior, thermodynamic and multiphase flow properties of multicomponent fluid mixtures. 2. Examine the impact of mineralogy and material heterogeneity on mechanical properties to better understand chemo-mechanical interactions in material failure. 3. Determine in-operando cross-scale structural and nanostructural material properties with fluids in confinement and flow under realistic condi

58 GEOSCIENCES↗

OES CO 2 Pipeline FEED Project Design Basis Memorandum

The OES CO₂ Pipeline project will move captured carbon dioxide from two ethanol facilities near Gibson City, Illinois, roughly 7.8 miles southeast to three injection wells outside Anchor, where it will be permanently stored underground. The system is designed to handle up to 4.5 million metric tonnes per year of dense-phase CO₂ at pressures up to 2,500 psig, using 16-inch mainline pipe and 10.750-inch laterals made from API 5L X-60 and X-65 steel. Wall thicknesses vary depending on location, with thinner pipe in open country, heavier wall at road crossings, and the heaviest where the pipe passes under highways or railroads via horizontal directional drill. The pipe gets a fusion-bonded epoxy coating, with an added abrasion-resistant layer wherever it's bored or drilled. Major water crossings will use HDD rather than open trenching. The pipeline will be cathodically protected, equipped with SCADA-compatible pressure and temperature instrumentation, and monitored for leaks using a computational pipeline monitoring system per API RP 1130. Hydrostatic testing will be performed at 1.25 times design pressure, and an ILI caliper run will follow to catch any construction defects. Several items, including fracture toughness requirements, specific NDE methods, and ILI tool selection, are left for the detailed design phase. The whole system falls under 49 CFR Part 195 and ASME B31.4, and Gulf Interstate Engineering prepared this document as the FEED-level design basis under the CarbonSAFE Phase III program.

09 BIOMASS FUELS↗

TCCSP Site Characterization and Feasibility Report

The Tulare County Carbon Storage Project (TCCSP) focused on establishing the geological and commercial viability of a 50 million metric ton (MMT) carbon storage complex located in Tulare County, California. The geologic scope of work included collecting new and existing subsurface data, such as two-dimensional (2D) seismic data, advanced geophysical logs, core and fluid samples, and specialized core-analysis datasets, to support the integration and interpretation of findings from earlier tasks. These efforts contributed to the comprehensive feasibility study for commercial carbon capture and storage (CCS) development at the TCCSP site and in the surrounding region. The TCCSP project team evaluated the feasibility of the Lower Monterey Group (Santa Margarita Sand Member or its equivalent), Temblor Formation sand members (Olcese, Jewett, Vedder), and Lodo-Martinez Zone (Domengine Sandstone, Walker Formation, Lodo Formation, and the Martinez Sand) to serve as commercial CCS reservoirs along with potential for the Upper Monterey Group (Reef Ridge, Antelope Members) and the Kreyenhagen Formation to vertically seal underlying reservoirs from shallow above-zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subsurface Energy Systems Mapping Inquiry Tool (MapIT)

The Subsurface Energy Systems Mapping Inquiry Tool (MapIT) is an online web mapping tool designed to help users discover available public-sourced data to facilitate data exploration for subsurface energy exploration and characterization efforts for resource identification (e.g. critical minerals, hydrocarbons, geothermal) as well as injection of geologic sequestration of carbon dioxide (e.g. enhanced oil recovery, saline storage, etc.). Modules within the tool curate data related to geology, faults, fractures, injection and confining zones, hydrologic information, groundwater, groundwater wells, geomechanical and petrophysical data, and geochemical data. User documentation on how to use the tool is also provided. Data have been collected from authoritative national, state, and local sources and made available in this tool. The data is also available as a data catalog and Esri Geodatabase at: https://edx.netl.doe.gov/dataset/mapit-database Disclaimer: There is no guarantee of completeness or appropriateness for individual user’s requirements. Use of this tool is solely at the discretion of the user. See full Federal Disclaimer for further information (https://netl.doe.gov/home/disclaimer). This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. https://www.netl.doe.gov/home/disclaimer

Carbon Sequestration↗

Basin-scale study of CO 2 storage in stacked sequence of geological formations

Commercial scale decarbonization through carbon capture and storage may likely involve many CO 2 storage projects located in close proximity. The close proximity could raise concerns over caprock integrity associated with reservoir pressure buildup and interference among adjacent projects. Commercial-scale injection will also require large prospective CO 2 storage resource and high injectivity in the targeted storage formations. To accommodate the need for both large resource and high injectivity, project operators could consider injecting CO 2 into a stacked sequence of formations. This analysis investigates the benefits of injecting CO 2 into a vertically stacked sequence of saline formations, over injecting the same amount of CO 2 into a single saline formation, in addressing these challenges. Our analysis shows that injecting into the stacked sequence mitigates the extent of pressure buildup among the stacked formations, while still achieving the same or greater target CO 2 storage volumes. Among cases modeled, the resulting pressure buildup front is most reduced when each storage site distributes injection volumes over several wells, each of which injects a portion of the total CO 2 mass across the stacked sequence. This favorable case not only results in the smallest CO 2 aerial footprint, but also shows the largest reduction in the pressure buildup at the top of perforation at the injection wells (upwards of approximately 46% compared to the single-formation storage), the result of which is crucial to maintain caprock integrity. This analysis provides insights into required decision-making when considering multi-project deployment in a shared basin.

42 ENGINEERING↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Prairie State Generating Company Static and Dynamic Modeling

A reservoir modeling study was conducted to assess the feasibility of storing 162.5 million tonnes (8.125 million tonnes annually) of industrially sourced carbon dioxide (CO 2 ) in the St. Peter – Everton and Knox storage complexes at the Prairie State Generating Company’s (PSGC) site near Marissa, Washington County, Illinois (PSGC site). Two separate models were constructed for the St. Peter – Everton and the Knox storage complexes. The St. Peter and Everton sandstones are the target storage units for the St. Peter – Everton storage complex. The Knox Group formations are the target storage units for the Knox storage complex. The Maquoketa Shale is the primary confining unit for both storage complexes. The static reservoir models used as input to the dynamic reservoir models of the storage complexes were developed from interpretations of logs (e.g., gamma ray, resistivity, porosity, photoelectric, and sonic), structure surfaces using data from 36 wells, thickness maps, well test data, seismic data, and permeability data in PetrelTM.

01 COAL, LIGNITE, AND PEAT↗

Prairie State Generating Company Site: Storage Field Development Plan

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, operational plans, and costs associated with the proposed Prairie State Energy Campus - Carbon Capture and Storage (PSEC-CCS) project in Washington County, Illinois, near Marissa. The proposed storage complex, known as the St. Peter-Everton Storage Complex, comprises the St. Peter Sandstone and Everton sandstone reservoirs, with the Maquoketa Shale serving as the primary confining unit and the Knox Group as lower confining unit. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Pennsylvanian section.

01 COAL, LIGNITE, AND PEAT↗