Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Hadron-quark phase transition in asymmetric matter with dynamical quark masses

The two-equation-of-state model is used to describe the hadron-quark phase transition in asymmetric matter formed at high density in heavy-ion collisions. For the quark phase, the three-flavor Nambu-Jona-Lasinio effective theory is used to investigate the influence of dynamical quark mass effects on the phase transition. At variance to the MIT-Bag results, with fixed-current quark masses, the main important effect of the chiral dynamics is the appearance of an end point for the coexistence zone. We show that a first-order hadron-quark phase transition may take place in the region T subset of (50-80) MeV and {rho}{sub B} subset of (2-4){rho}{sub 0}, which is possible to be probed in the new planned facilities, such as FAIR at GSI-Darmstadt and NICA at JINR-Dubna. From the isospin properties of the mixed phase, some possible signals are suggested. The importance of chiral symmetry and dynamical quark mass on the hadron-quark phase transition is stressed. The difficulty of an exact location of a critical end point comes from its appearance in a region of competition between chiral symmetry breaking and confinement, where our knowledge of effective QCD theories is still rather uncertain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time- and spectrally resolved measurements of laser-driven hohlraum radiation

At the GSI Helmholtz center for heavy-ion research combined experiments with heavy ions and laser-produced plasmas are investigated. As a preparation to utilize indirectly heated targets, where a converter hohlraum provides thermal radiation to create a more homogeneous plasma, this converter target has to be characterized. In this paper the latest results of these measurements are presented. Small spherical cavities with diameters between 600 and 750 {mu}m were heated with laser energies up to 30 J at 532-nm wavelength. Radiation temperatures could be determined by time-resolved as well as time-integrated diagnostics, and maximum values of up to 35 eV were achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time Modulation of the {beta}{sup +}-Decay Rate of H-Like {sup 140}Pr{sup 58+} Ions

Recent experimental data at GSI on the rates of the number of daughter ions, produced by the nuclear K-shell electron capture (EC) decays of the H-like ions {sup 140}Pr{sup 58+} and {sup 142}Pm{sup 60+}, suggest that they are modulated in time with periods T{sub EC}{approx_equal}7 sec and amplitudes a{sub EC}{approx_equal}0.20. Since it is known that these ions are unstable also under the nuclear positron ({beta}{sup +}) decays, we study a possible time dependence of the nuclear {beta}{sup +}-decay rate of the H-like {sup 140}Pr{sup 58+} ion. We show that the time dependence of the {beta}{sup +}-decay rate of the H-like {sup 140}Pr{sup 58+} ion as well as any H-like heavy ions cannot be observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing the Hydrogen Melting Line at High Pressures by Dynamic Compression

We investigate the capabilities of dynamic compression by intense heavy ion beams to yield information about the high pressure phases of hydrogen. Employing ab initio simulations and experimental data, a new wide range equation of state for hydrogen is constructed. The results show that the melting line up to its maximum as well as the transition from molecular fluids to fully ionized plasmas can be tested with the beam parameters soon to be available. We demonstrate that x-ray scattering can distinguish between phases and dissociation states.

43 PARTICLE ACCELERATORS↗

Search for the Pygmy Dipole Resonance in {sup 68}Ni at 600 MeV/nucleon

The {gamma} decay from Coulomb excitation of {sup 68}Ni at 600 MeV/nucleon on a Au target was measured using the RISING setup at the fragment separator of GSI. The {sup 68}Ni beam was produced by a fragmentation reaction of {sup 86}Kr at 900 MeV/nucleon on a {sup 9}Be target and selected by the fragment separator. The {gamma} rays produced at the Au target were measured with HPGe detectors at forward angles and with BaF{sub 2} scintillators at backward angles. The measured spectra show a peak centered at approximately 11 MeV, whose intensity can be explained in terms of an enhanced strength of the dipole response function (pygmy resonance). Such pygmy structure has been predicted in this unstable neutron-rich nucleus by theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

One-Neutron Removal Measurement Reveals {sup 24}O as a New Doubly Magic Nucleus

The first measurement of the momentum distribution for one-neutron removal from {sup 24}O at 920A MeV performed at GSI, Darmstadt is reported. The observed distribution has a width (FWHM) of 99{+-}4 MeV/c in the projectile rest frame and a one-neutron removal cross section of 63{+-}7 mb. The results are well explained with a nearly pure 2s{sub 1/2} neutron spectroscopic factor of 1.74{+-}0.19 within the eikonal model. This large s-wave probability shows a spherical shell closure thereby confirming earlier suggestions that {sup 24}O is a new doubly magic nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the In-Medium K{sup 0} Inclusive Cross Section in {pi}{sup -}-Induced Reactions at 1.15 GeV/c

The K{sup 0} meson production by {pi}{sup -} mesons of 1.15 GeV/c momentum on C, Al, Cu, Sn, and Pb nuclear targets was measured with the FOPI spectrometer at the Schwer-Ionen-Synchrotron accelerator of GSI. Inclusive production cross sections and the momentum distributions of K{sup 0} mesons are compared to scaled elementary production cross sections and to predictions of theoretical models describing the in-medium production of kaons. The data represent a new reference for those models, which are widely used for interpretation of the strangeness production in heavy-ion collisions. The presented results demonstrate the sensitivity of the kaon production to the reaction amplitudes inside nuclei and point to the existence of a repulsive KN potential of 20{+-}5 MeV at normal nuclear matter density.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Evidence of Space Charge Driven Emittance Coupling in High Intensity Linear Accelerators

In high intensity linacs emittance exchange driven by space charge coupling may lead to the well-known 'equipartitioning' phenomenon if the stop band at sigma{sub ||}=sigma{sub perpendicular} is crossed at sufficiently slow rate. This Letter is the first experimental evidence of this phenomenon in a high intensity linear accelerator, here the UNILAC at GSI. Measurements of emittances at the entrance and exit of one drift tube linac tank comprising 15 lattice cells are taken for a set of transverse and longitudinal tunes. The onset of exchange on the stop band of previously derived 'stability charts' confirms theoretical predictions. The measured transverse emittance growth also compares well with results from the beam dynamics simulation codes DYNAMION and TRACEWIN.

43 PARTICLE ACCELERATORS↗

Spectroscopy of element 115 decay chains

A high-resolution a, X-ray and -ray coincidence spectroscopy experiment was conducted at the GSI Helmholtzzentrum fu r Schwerionenforschung. Thirty correlated a-decay chains were detected following the fusion-evaporation reaction 48Ca + 243Am. The observations are consistent with previous assignments of similar decay chains to originate from element Z = 115. The data includes first candidates of fingerprinting the decay step Mt --> Bh with characteristic X rays. For the first time, precise spectroscopy allows the derivation of excitation schemes of isotopes along the decay chains starting with elements Z > 112. Comprehensive Monte-Carlo simulations accompany the data analysis. Nuclear structure models provide a first level interpretation.

Rudolph, Dirk↗

Fourth order resonance of a high intensity linear accelerator*

For a high intensity beam, the 4\nu=1 resonance of a linear accelerator is manifested through the octupolar term of space charge potential when the depressed phase advance \sigma is close to and below 90 but no resonance effect is observed when \sigma just above 90 . To verify that this is a resonance, a frequency analysis is performed and a study of resonance crossing from above and from below the resonance is conducted. It is observed that this fourth order resonance is dominating over the better known envelope instability and practically replacing it. Simulation study shows a clear emittance growth by this resonance and its stopband. One of the authors [DJ] proposed an experiment to measure the stopband of this resonance to GSI using the UNILAC.

43 PARTICLE ACCELERATORS↗

Incoherent effect of space charge and electron cloud

Trapping by resonances or scattering off resonances induced by space charge (SC) or electron cloud (EC) in conjunction with synchrotron motion can explain observations of slow beam loss and emittance growth, which are often accompanied by changes in the longitudinal beam profile. In this paper we review the recent progress in understanding and modeling of the underlying mechanisms, highlight the differences and similarities between space charge and electron cloud, and discuss simulation results in the light of experimental observations, e.g., at GSI, CERN, and BNL. In particular, we address the role of the pinched electrons and describe in detail the complexity of the electron pinch formation. We present simulation results within a dipole or in a field-free region of the beam pipe, which reveal the morphology and main features of this phenomenon, explain the physical origin of the complex electron structures like stripe in either field configuration, and discuss the dependence on some key parameters.

43 PARTICLE ACCELERATORS↗

Heavy-ion tumor therapy: Physical and radiobiological benefits

High-energy beams of charged nuclear particles (protons and heavier ions) offer significant advantages for the treatment of deep-seated local tumors in comparison to conventional megavolt photon therapy. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum (Bragg peak) near the end of range with a sharp fall-off at the distal edge. Taking full advantage of the well-defined range and the small lateral beam spread, modern scanning beam systems allow delivery of the dose with millimeter precision. In addition, projectiles heavier than protons such as carbon ions exhibit an enhanced biological effectiveness in the Bragg peak region caused by the dense ionization of individual particle tracks resulting in reduced cellular repair. This makes them particularly attractive for the treatment of radio-resistant tumors localized near organs at risk. While tumor therapy with protons is a well-established treatment modality with more than 60 000 patients treated worldwide, the application of heavy ions is so far restricted to a few facilities only. Nevertheless, results of clinical phase I-II trials provide evidence that carbon-ion radiotherapy might be beneficial in several tumor entities. This article reviews the progress in heavy-ion therapy, including physical and technical developments, radiobiological studies and models, as well as radiooncological studies. As a result of the promising clinical results obtained with carbon-ion beams in the past ten years at the Heavy Ion Medical Accelerator facility (Japan) and in a pilot project at GSI Darmstadt (Germany), the plans for new clinical centers for heavy-ion or combined proton and heavy-ion therapy have recently received a substantial boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mass of 101 Sn and Bayesian extrapolations to the proton drip line

The favorable energy configurations of nuclei at magic numbers of 𝑁 neutrons and 𝑍 protons are fundamental for understanding the evolution of nuclear structure. The 𝑍 = 50 (tin) isotopic chain is a frontier for such studies, with particular interest at and around the doubly magic 100 Sn isotope, for which the mass is a topic of debate. Precise mass values for neutron-deficient isotopes provide necessary anchor points for mass models to test extrapolations near the proton drip line, where experimental studies remain out of reach. In this work, we report a Penning trap mass measurement of 101 Sn . The determined mass excess of −59889.89⁢(96) keV for 101 Sn represents a factor-of-300 improvement over the current precision and indicates that 101 Sn is less bound than previously thought. Mass predictions from a recently developed Bayesian model combination framework employing statistical machine learning and nuclear masses computed within seven global models based on nuclear density functional theory agree within 1⁢𝜎 with experimental masses from the 48 ≤ 𝑍 ≤ 52 isotopic chains. The framework's resilience to new mass data gave confidence in the extrapolation of tin masses down to 𝑁 = 46. Our calculations suggest that 96 Sn is a two-proton drip line nucleus and predict a mass excess of −58090⁢(800) keV for 100 Sn , showing a preference within 1⁢𝜎 for the mass of 100 Sn derived from the 𝛽-delayed 𝑄 value measured at GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total fission cross section of {sup 181}Ta and {sup 208}Pb induced by protons at relativistic energies

Total fission cross section induced by protons in {sup 181}Ta and {sup 208}Pb at energies in the range of 300 to 1000 A MeV have been measured at GSI (Germany) using the inverse kinematics technique. A dedicated setup with high efficiency made it possible to determine these cross sections with high accuracy. The new data seed light in the controversial results obtained so far and contribute to the understanding of the fission process at high excitation energies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient species identification for Pacific salmon genetic monitoring programs

Abstract Genetic monitoring of Pacific salmon in the Columbia River basin provides crucial information to fisheries managers that is otherwise challenging to obtain using traditional methods. Monitoring programs such as genetic stock identification (GSI) and parentage‐based tagging (PBT) involve genotyping tens of thousands of individuals annually. Although rare, these large sample collections inevitably include misidentified species, which exhibit low genotyping success on species‐specific Genotyping‐in‐Thousands by sequencing (GT‐seq) panels. For laboratories involved in large‐scale genotyping efforts, diagnosing non‐target species and reassigning them to the appropriate monitoring program can be costly and time‐consuming. To address this problem, we identified 19 primer pairs that exhibit consistent cross‐species amplification among salmonids and contain 51 species informative variants. These genetic markers reliably discriminate among 11 salmonid species and two subspecies of Cutthroat Trout and have been included in species‐specific GT‐seq panels for Chinook Salmon, Coho Salmon, Sockeye Salmon, and Rainbow Trout commonly used for Pacific salmon genetic monitoring. The majority of species‐informative amplicons (16) were newly identified from the four existing GT‐seq panels, thus demonstrating a low‐cost approach to species identification when using targeted sequencing methods. A species‐calling script was developed that is tailored for routine GT‐seq genotyping pipelines and automates the identification of non‐target species. Following extensive testing with empirical and simulated data, we demonstrated that the genetic markers and accompanying script accurately identified species and are robust to missing genotypic data and low‐frequency, shared polymorphisms among species. Finally, we used these tools to identify Coho Salmon incidentally caught in the Columbia River Chinook Salmon sport fishery and used PBT to determine their hatchery of origin. These molecular and computing resources provide a valuable tool for Pacific salmon conservation in the Columbia River basin and demonstrate a cost‐effective approach to species identification for genetic monitoring programs.

Robinson, Zachary L.↗

Analysis of metabolic washout of positron emitters produced during carbon ion head and neck radiotherapy

Purpose: Particle Therapy Positron Emission Tomography (PT-PET) is a suitable method for verification of therapeutic dose delivery by measurements of irradiation-induced β{sup +}-activity. Due to metabolic processes in living tissue β{sup +}-emitters can be removed from the place of generation. This washout is a limiting factor for image quality. The purpose of this study is to investigate whether a washout model obtained by animal experiments is applicable to patient data.Methods: A model for the washout has been developed by Mizuno et al. [Phys. Med. Biol. 48(15), 2269–2281 (2003)] and Tomitani et al. [Phys. Med. Biol. 48(7), 875–889 (2003)]. It is based upon measurements in a rabbit in living and dead conditions. This model was modified and applied to PET data acquired during the experimental therapy project at GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, Germany. Three components are expected: A fast one with a half life of 2 s, a medium one in the range of 2–3 min, and a slow component of the order of 2–3 h. Ten patients were selected randomly for investigation of the fast component. To analyze the other two components, 12 one-of-a-kind measurements from a single volunteer patient are available.Results: A fast washout on the time scale of a few seconds was not observed in the patient data. The medium processes showed a mean half life of 155.7 ± 4.6 s. This is in the expected range. Fractions of the activity not influenced by the washout were found.Conclusions: On the time scale of an in-beam or in-room measurement only the medium-time washout processes play a remarkable role. A slow component may be neglected if the measurements do not exceed 20 min after the end of the irradiation. The fast component is not observed due to the low relative blood filled volume in the brain.

61 RADIATION PROTECTION AND DOSIMETRY↗