Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Trends in alkali metal hydrosulfides: A combined Fourier transform microwave/millimeter-wave spectroscopic study of KSH (X{sup ~1}A{sup ′})

The pure rotational spectrum of KSH (X{sup ~1}A{sup ′}) has been measured using millimeter-wave direct absorption and Fourier transform microwave (FTMW) techniques. This work is the first gas-phase experimental study of this molecule and includes spectroscopy of KSD as well. In the millimeter-wave system, KSH was synthesized in a DC discharge from a mixture of potassium vapor, H{sub 2}S, and argon; a discharge-assisted laser ablation source, coupled with a supersonic jet expansion, was used to create the species in the FTMW instrument. Five and three rotational transitions in the range 3–57 GHz were recorded with the FTMW experiment for KSH and KSD, respectively, in the K{sub a} = 0 component; in these data, potassium quadrupole hyperfine structure was observed. Five to six transitions with K{sub a} = 0–5 were measured in the mm-wave region (260–300 GHz) for the two species. The presence of multiple asymmetry components in the mm-wave spectra indicates that KSH has a bent geometry, in analogy to other alkali hydrosulfides. The data were analyzed with an S-reduced asymmetric top Hamiltonian, and rotational, centrifugal distortion, and potassium electric quadrupole coupling constants were determined for both isotopolgues. The r{sub 0} geometry for KSH was calculated to be r{sub S-H} = 1.357(1) Å, r{sub K-S} = 2.806(1) Å, and θ{sub M-S-H} (°) = 95.0 (1). FTMW measurements were also carried out on LiSH and NaSH; metal electric quadrupole coupling constants were determined for comparison with KSH. In addition, ab initio computations of the structures and vibrational frequencies at the CCSD(T)/6-311++G(3df,2pd) and CCSD(T)/aug-cc-pVTZ levels of theory were performed for LiSH, NaSH, and KSH. Overall, experimental and computational data suggest that the metal-ligand bonding in KSH is a combination of electrostatic and covalent forces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of the Kinetics of the Phase Transition of the First Order in Tetracosane C{sub 24}H{sub 50} by Fourier-Transform IR Spectroscopy

The kinetics of the development of the structural phase transition of the first order in monodisperse samples of tetracosane C{sub 24}H{sub 50} has been studied using Fourier-transform IR spectroscopy. Temperature dependences of frequencies and intensities of rocking (in the region of ν ~ 720 cm{sup –1}) and bending (in the region of ν ~ 1470 cm{sup –1}) vibration modes of CH{sub 2} groups in trans methylene sequences in crystalline cores of elementary lamellae has been analyzed. It has been shown that the solid-phase transition of the first order develops by the heterogeneous mechanism in a narrow temperature interval ΔT ~ 2 K according to the theory of diffuse phase transitions of the first order and is caused by changes in the symmetry of crystallographic cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Numerical study of the effect of normalised window size, sampling frequency, and noise level on short time Fourier transform analysis

Photonic Doppler velocimetry, also known as heterodyne velocimetry, is a widely used optical technique that requires the analysis of frequency modulated signals. This paper describes an investigation into the errors of short time Fourier transform analysis. The number of variables requiring investigation was reduced by means of an equivalence principle. Error predictions, as the number of cycles, samples per cycle, noise level, and window type were varied, are presented. The results were found to be in good agreement with analytical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data. The algorithm is completely automatic and requires very little processing time. The algorithm is cost efficient and can be easily adopted for everyday clinical use.

60 APPLIED LIFE SCIENCES↗

Fourier transform infrared spectroscopy measurements of multi-phonon and free-carrier absorption in ZnO

Fourier transform infrared (FTIR) measurements were carried out on thin films and bulk single crystals of ZnO over a wide temperature range to study the free-carrier and multi-phonon infrared absorptions and the effects of hydrogen incorporation on these properties. Aluminum-doped ZnO thin films were deposited on quartz substrates using atomic-layer deposition (ALD) and sol–gel methods. Hall-effect measurements showed that the ALD films have a resistivity of ρ = 1.11 × 10 –3 Ω cm, three orders of magnitude lower than sol–gel films (ρ = 1.25 Ω cm). This result is consistent with the significant difference in their free-carrier absorption as revealed by FTIR spectra obtained at room temperature. By reducing the temperature to 80 K, the free carriers were frozen out, and their absorption spectrum was suppressed. From the FTIR measurements on ZnO single crystals that were grown by the chemical vapor transport method, we identified a shoulder around 3350 cm –1 and associated it with the presence of two or more hydrogen ions in a Zn vacancy. After reducing the hydrogen level in the crystal, the measurements revealed the multi-phonon absorption of ZnO in the range of 700–1200 cm –1 . Furthermore, this study shows that the multi-phonon absorption bands can be completely masked by the presence of a large concentration of hydrogen in the crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The application of Fourier transform spectroscopy to the remote identification of solids in the solar system

The techniques of Fourier transform spectroscopy combined with large aperture telescopes and advances in detector technology now permit infrared (at a wavelength greater than 1 micron) observations of the surfaces of small solar system objects such as asteroids and satellites. The results demonstrate that this activity can produce important new compositional information related to the origin and evolution of the solar system. The detection of water ice in Saturn's rings and on some of the satellites of Jupiter and Saturn confirm expectations that ices are important mineralogical components in the chemistry of the outer solar system. More recent studies of the mineralogical composition of the surfaces of asteroids provide a new observational link to the origin of meteorites and the early thermal history of the solar system. These results have been dependent upon supporting laboratory studies of the spectral behavior of ices and minerals to define the potential, and limitations, of the method. Since many of the astronomical observations have been exploratory in nature, prospects are good that continued refinement of the techniques will lead to additional insights.

Larson, H. P.↗

Determination of grain size distribution function using two-dimensional Fourier transforms of tone pulse encoded images

Microstructural images may be tone pulse encoded and subsequently Fourier transformed to determine the two-dimensional density of frequency components. A theory is developed relating the density of frequency components to the density of length components. The density of length components corresponds directly to the actual grain size distribution function from which the mean grain shape, size, and orientation can be obtained.

Generazio, E. R.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

Measurements of deuterium quadrupole coupling in propiolic acid and fluorobenzenes using pulsed-beam Fourier transform microwave spectrometers

The pure rotational spectra of deuterated propiolic acids (HCCCOOD and DCCCOOH), 1-fluorobenzene (4-d{sub 1}), and 1,2-difluorobenzene (4-d{sub 1}) in their ground states have been measured using two Fourier transform microwave (FTMW) spectrometers at the University of Arizona. For 1-fluorobenzene (4-d{sub 1}), nine hyperfine lines of three different ΔJ = 0 and 1 transitions were measured to check the synthesis method and resolution. For 1,2-difluorobenzene (4-d{sub 1}), we obtained 44 hyperfine transitions from 1 to 12 GHz, including 14 different ΔJ = 0, 1 transitions. Deuterium quadrupole coupling constants along the three principal inertia axes were well determined. For deuterated propiolic acids, 37 hyperfine lines of Pro-OD and 59 hyperfine lines of Pro-CD, covering 11 and 12 different ΔJ = − 1, 0, 1 transitions, respectively, were obtained from 5 to 16 GHz. Deuterium quadrupole coupling constants along the three inertia axes were well resolved for Pro-OD. For Pro-CD, only eQq{sub aa} was determined due to the near coincidence of the CD bond and the least principal inertia axis. Some measurements were made using a newer FTMW spectrometer employing multiple free induction decays as well as background subtraction. For 1-fluorobenzene (4-d{sub 1}) and 1,2-difluorobenzene (4-d{sub 1}), a very large-cavity (1.2 m mirror dia.) spectrometer yielded very high resolution (2 kHz) spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of the one-dimensional Fourier transform for tracking moving objects in noisy environments

In Riddle and Rajala (1981), an algorithm was presented which operates on an image sequence to identify all sets of pixels having the same velocity. The algorithm operates by performing a transformation in which all pixels with the same two-dimensional velocity map to a peak in a transform space. The transform can be decomposed into applications of the one-dimensional Fourier transform and therefore can gain from the computational advantages of the FFT. The aim of this paper is the concern with the fundamental limitations of that algorithm, particularly as relates to its sensitivity to image-disturbing parameters as noise, jitter, and clutter. A modification to the algorithm is then proposed which increases its robustness in the presence of these disturbances.

Rajala, S. A.↗

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of grain-size distribution function using two-dimensional Fourier transforms of tone-pulse-encoded images

Microstructural images may be tone pulse encoded and subsequently Fourier transformed to determine the two-dimensional density of frequency components. A theory is developed relating the density of frequency components to the density of length components. The density of length components corresponds directly to the actual grain-size distribution function from which the mean grain shape, size, and orientation can be obtained.

Generazio, E. R.↗

Continued Development of a Planetary Imaging Fourier Transform Spectrometer (PIFTS)

This report describes continued efforts to evaluate a breadboard of a Planetary Imaging Fourier Transform Spectrometer (PIFTS). The PIFTS breadboard was developed under prior PIDDP funding. That effort is described in the final report for NASA Grant NAG5-6248 and in two conference papers (Sromovsky et al. 2000; Revercomb et al. 2000). The PIFTS breadboard was designed for near-IR (1-5.2 micrometer imaging of planetary targets with spectral resolving powers of several hundred to several thousand, using an InSb detector array providing at least 64x64 pixels imaging detail. The major focus of the development effort was to combine existing technologies to produce a small and low power design compatible with a very low mass flyable instrument. The objective of this grant (NAG5-10729) was further characterization of the breadboard performance, including intercomparisons with the highly accurate non-imaging Advanced Emitted Radiance Interferometer (AERI) (Revercomb et al. 1994; Best et al. 1997).

Sromovsky, L. A.↗

Reference Ultraviolet Wavelengths of Cr III Measured by Fourier Transform Spectrometry

We report Cr III ultraviolet (UV) transition wavelengths measured using a high-resolution Fourier transform spectrometer (FTS), for the first time, available for use as wavelength standards. The doubly ionized iron group element spectra dominate the observed opacity of hot B stars in the UV, and improved, accurate, wavelengths are required for the analysis of astronomical spectra. The spectrum was excited using a chromium-neon Penning discharge lamp and measured with the Imperial College vacuum ultraviolet FTS. 140 classified 3d(exp 3)4s- 3d(exp 3)4p Cr III transition lines, in the spectral range 38,000 to 49,000 cm(exp -1) (2632 to 2041 A), the strongest having wavelength uncertainties less than one part in 10(exp 7), are presented.

Smillie, D.G.↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adding diffuse reflectance infrared Fourier transform spectroscopy capability to extended x-ray-absorption fine structure in a new cell to study solid catalysts in combination with a modulation approach

We describe a novel cell used to combine in situ transmission X-ray absorption spectroscopy (XAS) with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) in a single experiment. The novelty of the cell design compared to current examples is that both radiations are passed through an X-ray and IR transparent window in direct contact with the sample. This innovative geometry also offers a wide surface for IR collection. In order to avoid interference from the crystalline IR transparent materials (e.g., CaF{sub 2}, MgF{sub 2}, diamond) a 500 μm carbon filled hole is laser drilled in the center of a CaF{sub 2} window. The cell is designed to represent a plug flow reactor, has reduced dead volume in order to allow for fast exchange of gases and is therefore suitable for experiments under fast transients, e.g., according to the concentration modulation approach. High quality time-resolved XAS and DRIFTS data of a 2 wt.% Pt/Al{sub 2}O{sub 3} catalyst are obtained in concentration modulation experiments where CO (or H{sub 2}) pulses are alternated to O{sub 2} pulses at 150 °C. We show that additional information can be obtained on the Pt redox dynamic under working conditions thanks to the improved sensitivity given by the modulation approach followed by Phase Sensitive Detection (PSD) analysis. It is anticipated that the design of the novel cell is likely suitable for a number of other in situ spectroscopic and diffraction methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗