Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Compact Microscope Imaging System with Intelligent Controls

The figure presents selected views of a compact microscope imaging system (CMIS) that includes a miniature video microscope, a Cartesian robot (a computer- controlled three-dimensional translation stage), and machine-vision and control subsystems. The CMIS was built from commercial off-the-shelf instrumentation, computer hardware and software, and custom machine-vision software. The machine-vision and control subsystems include adaptive neural networks that afford a measure of artificial intelligence. The CMIS can perform several automated tasks with accuracy and repeatability . tasks that, heretofore, have required the full attention of human technicians using relatively bulky conventional microscopes. In addition, the automation and control capabilities of the system inherently include a capability for remote control. Unlike human technicians, the CMIS is not at risk of becoming fatigued or distracted: theoretically, it can perform continuously at the level of the best human technicians. In its capabilities for remote control and for relieving human technicians of tedious routine tasks, the CMIS is expected to be especially useful in biomedical research, materials science, inspection of parts on industrial production lines, and space science. The CMIS can automatically focus on and scan a microscope sample, find areas of interest, record the resulting images, and analyze images from multiple samples simultaneously. Automatic focusing is an iterative process: The translation stage is used to move the microscope along its optical axis in a succession of coarse, medium, and fine steps. A fast Fourier transform (FFT) of the image is computed at each step, and the FFT is analyzed for its spatial-frequency content. The microscope position that results in the greatest dispersal of FFT content toward high spatial frequencies (indicating that the image shows the greatest amount of detail) is deemed to be the focal position.

McDowell, Mark↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Detection of coherent optical phonons in a thin bismuth film by ultrafast electron diffraction

Coherent dynamics of lattice oscillations in a ∼20-nm-thick film obtained by thermal sputtering of bismuth is studied using ultrashort electron bunches synchronised with femtosecond laser pulses irradiating the sample. The Fourier analysis of ultrafast electron diffraction (UED) data shows that the observed modulation of the signal is due to the ensemble of modes corresponding to optical phonons with frequencies of approximately 3, 6 and 9 THz. A conclusion is made that these peaks correspond to the manifestation of the bismuth A{sub 1g} mode (three-terahertz peak), as well as its first and second overtones, which is probably due to quantum confinement in a 20-nm Bi nanostructure. The possibility of a detailed study of the quantum-size effect in bismuth with the help of a transmission UED is analysed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

Foundations of machine learning for low-temperature plasmas: methods and case studies

Abstract Machine learning (ML) and artificial intelligence have proven to be an invaluable tool in tackling a vast array of scientific, engineering, and societal problems. The main drivers behind the recent proliferation of ML in practically all aspects of science and technology can be attributed to: (a) improved data acquisition and inexpensive data storage; (b) exponential growth in computing power; and (c) availability of open-source software and resources that have made the use of state-of-the-art ML algorithms widely accessible. The impact of ML on the field of low-temperature plasmas (LTPs) could be particularly significant in the emerging applications that involve plasma treatment of complex interfaces in areas ranging from the manufacture of microelectronics and processing of quantum materials, to the LTP-driven electrification of the chemical industry, and to medicine and biotechnology. This is primarily due to the complex and poorly-understood nature of the plasma-surface interactions in these applications that pose unique challenges to the modeling, diagnostics, and predictive control of LTPs. As the use of ML is becoming more prevalent, it is increasingly paramount for the LTP community to be able to critically analyze and assess the concepts and techniques behind data-driven approaches. To this end, the goal of this paper is to provide a tutorial overview of some of the widely-used ML methods that can be useful, amongst others, for discovering and correlating patterns in the data that may be otherwise impractical to decipher by human intuition alone, for learning multivariable nonlinear data-driven prediction models that are capable of describing the complex behavior of plasma interacting with interfaces, and for guiding the design of experiments to explore the parameter space of plasma-assisted processes in a systematic and resource-efficient manner. We illustrate the utility of various supervised, unsupervised and active learning methods using LTP datasets consisting of commonly-available, information-rich measurements (e.g. optical emission spectra, current–voltage characteristics, scanning electron microscope images, infrared surface temperature measurements, Fourier transform infrared spectra). All the ML demonstrations presented in this paper are carried out using open-source software; the datasets and codes are made publicly available. The FAIR guiding principles for scientific data management and stewardship can accelerate the adoption and development of ML in the LTP community.

Physics↗

Spin-lattice and spin-electronic interactions in the van der Waals semiconductor C⁢o 2 ⁢P 2 ⁢S 6

Here, we report the results of a temperature-dependent reflection spectroscopy study, across a wide energy range (~ 0.01 to 3 eV), of unsubstituted and 40% Zn substituted for Co, for the transition-metal phosphorus trichalcogenide, C⁢o 2 ⁢P 2 ⁢S 6 . We observe a transition from a paramagnetic to antiferromagnetic state with a Néel temperature at T N ~ 120 K that is completely suppressed in Zn-substituted samples. At 300 K we identify four narrow (~ 1 meV) infrared active phonon modes while at 70 K (below T N ) we observe that the low-energy phonons, dominated by Co motion, resolve into two modes. These low-energy modes are asymmetric, indicating coupling to a broad electronic continuum. We also report a broad (~ 30 meV) low-temperature infrared absorption band that appears near T N that we suggest is determined by a multiphonon-assisted 2-magnon absorption process. At 300 K in higher-energy spectra, we observe considerable absorption starting from 0.20 ± 0.02 eV which we associate with inter-C⁢o 2+ ion 3⁢d transitions. At temperatures below T N the number of electronic absorption bands increases from 4 to 6, indicating a lowering of the symmetry around the C⁢o 2+ ions. On substituting 40% Zn for Co, the antiferromagnetic transition is suppressed along with temperature-dependent changes in the phonon and electronic spectra. The temperature-dependent spectral changes indicate strongly correlated behavior between the infrared active lattice vibrations, the electronic excitations, and magnetism in unsubstituted C⁢o 2 ⁢P 2 ⁢S 6 .

2-dimensional systems↗

SETI - High sensitivity searches at NASA with high speed tape recorders

The paper reports the two observing programs conducted to compare two techniques which have been proposed as methods for performing the requisite Fourier transformations in very large multichannel spectrum analysers (MCSA): the direct digital FFT and optical transform processor. The details of the observations at NRAO utilizing a direct digital FFT are given. A description of the NAIC, Arecibo observations utilizing an optical processor at the Environmental Research Institute of Michigan (ERIM) and a microdensitometer at Electromagnetics System Laboratories (ESL) is presented. For both observing programs, statistical analysis of the power spectra produced by the nonreal-time MCSAs (or post-processing) was accomplished.

Tarter, J.↗

[Photodissociation of Acetylene and Acetone using Step-Scan Time-Resolved FTIR Emission Spectroscopy]

The photodissociation of acetylene and acetone was investigated as a function of added quenching gas pressures using step-scan time-resolved FTIR emission spectroscopy. Its main components consist of Bruker IFS88, step-scan Fourier Transform Infrared (FTIR) spectrometer coupled to a flow cell equipped with Welsh collection optics. Vibrationally excited C2H radicals were produced from the photodissociation of acetylene in the unfocused experiments. The infrared (IR) emission from these excited C2H radicals was investigated as a function of added argon pressure. Argon quenching rate constants for all C2H emission bands are of the order of 10(exp -13)cc/molecule.sec. Quenching of these radicals by acetylene is efficient, with a rate constant in the range of 10(exp -11) cc/molecule.sec. The relative intensity of the different C2H emission bands did not change with the increasing argon or acetylene pressure. However, the overall IR emission intensity decreased, for example, by more than 50% when the argon partial pressure was raised from 0.2 to 2 Torr at fixed precursor pressure of 160mTorr. These observations provide evidence for the formation of a metastable C2H2 species, which are collisionally quenched by argon or acetylene. Problems encountered in the course of the experimental work are also described.

McLaren, Ian A.↗

A Polarimetric Extension of the van Cittert-Zernike Theorem for Use with Microwave Interferometers

The van Cittert-Zernike theorem describes the Fourier-transform relationship between an extended source and its visibility function. Developments in classical optics texts use scalar field formulations for the theorem. Here, we develop a polarimetric extension to the van Cittert-Zernike theorem with applications to passive microwave Earth remote sensing. The development provides insight into the mechanics of two-dimensional interferometric imaging, particularly the effects of polarization basis differences between the scene and the observer.

Piepmeier, J. R.↗

A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

Heverly, Matthew↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

The composite classification problem in optical information processing

Optical pattern recognition allows objects to be recognized from their images and permits their positional parameters to be estimated accurately in real time. The guiding principle behind optical pattern recognition is that a lens focusing a beam of coherent light modulated with an image produces the two-dimensinal Fourier transform of that image. When the resulting output is further transformed by the matched filter corresponding to the original image, one obtains the autocorrelation function of the original image, which has a peak at the origin. Such a device is called an optical correlator and may be used to recognize the locate the image for which it is designed. (From a practical perspective, an approximation to the matched filter must be used since the spatial light modulator (SLM) on which the filter is implemented usually does not allow one to independently control both the magnitude and phase of the filter.) Generally, one is not just concerned with recognizing a single image but is interested in recognizing a variety of rotated and scaled views of a particular image. In order to recognize these different views using an optical correlator, one may select a subset of these views (whose elements are called training images) and then use a composite filter that is designed to produce a correlation peak for each training image. Presumably, these peaks should be sharp and easily distinguishable from the surrounding correlation plane values. In this report we consider two areas of research regarding composite optical correlators. First, we consider the question of how best to choose the training images that are used to design the composite filter. With regard to quantity, the number of training images should be large enough to adequately represent all possible views of the targeted object yet small enough to ensure that the resolution of the filter is not exhausted. As for the images themselves, they should be distinct enough to avoid numerical difficulties yet similar enough to avoid gaps in which certain views of the target will be unrecognized. One method that we introduce to study this problem is called probing and involves the creation of the artificial imagery. The second problem we consider involves the clasification of the composite filter's correlation plane data. In particular, we would like to determine not only whether or not we are viewing a training image, but, in the former case, we would like to determine which training image is being viewed. This second problem is investigated using traditional M-ary hypothesis testing techniques.

Hall, Eric B.↗

Discovery of a Similar to 5 Day Characteristic Timescale in the Kepler Power Spectrum of Zw 229-15

We present time series analyses of the full Kepler dataset of Zw 229− 15. This Kepler light curve- with a baseline greater than three years, composed of virtually continuous, evenly sampled 30-minute measurements - is unprecedented in its quality and precision. We utilize two methods of power spectral analysis to investigate the optical variability and search for evidence of a bend frequency associated with a characteristic optical variability timescale. Each method yields similar results. The first interpolates across data gaps to use the standard Fourier periodogram. The second, using the CARMA-based time-domain modeling technique of Kelly et al., does not need evenly-sampled data. Both methods find excess power at high frequencies that may be due to Kepler instrumental effects. More importantly both also show strong bends (delta alpha is approx. 2) at timescales of approx. 5 days, a feature similar to those seen in the X-ray PSDs of AGN but never before in the optical. This observed approx. 5 day timescale may be associated with one of several physical processes potentially responsible for the variability. A plausible association could be made with light -crossing, dynamical or thermal timescales, depending on the assumed value of the accretion disk size and on unobserved disk parameters such as alpha and H¬R. This timescale is not consistent with the viscous timescale, which would be years in a approx. 10(exp7) solar mass AGN such as Zw 229− 15. However there must be a second bend on long (& 1 year) timescales, and that feature could be associated with the viscous timescale.

timescale↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

Comparison of various methods for mathematical analysis of the Foucault knife edge test pattern to determine optical imperfections

The linearized integral equation for the Foucault test of a solid mirror was solved by various methods: power series, Fourier series, collocation, iteration, and inversion integral. The case of the Cassegrain mirror was solved by a particular power series method, collocation, and inversion integral. The inversion integral method appears to be the best overall method for both the solid and Cassegrain mirrors. Certain particular types of power series and Fourier series are satisfactory for the Cassegrain mirror. Numerical integration of the nonlinear equation for selected surface imperfections showed that results start to deviate from those given by the linearized equation at a surface deviation of about 3 percent of the wavelength of light. Several possible procedures for calibrating and scaling the input data for the integral equation are described.

Gatewood, B. E.↗

Apparatus and Method for Measuring Strain in Optical Fibers using Rayleigh Scatter

An apparatus and method for measuring strain in an optical fiber using the spectral shift of Rayleigh scattered light. The interference pattern produced by an air gap reflector and backscattered radiation is measured. Using Fourier Transforms, the spectrum of any section of fiber can be extracted. Cross correlation with an unstrained measurement produces a correlation peak. The location of the correlation peak indicates the strain level in the selected portion of optical fiber.

Froggatt, Mark E.↗

Electrochemical Reactivity and Passivation of Silicon Thin-Film Electrodes in Organic Carbonate Electrolytes

This work focuses on the mechanisms of interfacial processes at the surface of amorphous silicon thin-film electrodes in organic carbonate electrolytes to unveil the origins of the inherent nonpassivating behavior of silicon anodes in Li-ion batteries. Attenuated total reflection Fourier-transform infrared spectroscopy, X-ray absorption spectroscopy, and infrared near-field scanning optical microscopy were used to investigate the formation, evolution, and chemical composition of the surface layer formed on Si upon cycling. Herein, we found that the chemical composition and thickness of the solid/electrolyte interphase (SEI) layer continuously change during the charging/discharging cycles. This SEI layer “breathing” effect is directly related to the formation of lithium ethylene dicarbonate (LiEDC) and LiPF6 salt decomposition products during silicon lithiation and their subsequent disappearance upon delithiation. Furthermore, the detected appearance and disappearance of LiEDC and LiPF6 decomposition compounds in the SEI layer are directly linked with the observed interfacial instability and poor passivating behavior of the silicon anode.

25 ENERGY STORAGE↗