Compton Observatory observations of clusters of galaxies and extragalactic radio sources

This task involved the investigation of the emission of clusters of galaxies, particularly those which contain extended radio emission, in the gamma-ray region of the spectrum. Observations were made of several clusters using the Compton Observatory EGRET instrument. For each cluster a measured flux or upper limit on the gamma-ray flux was obtained. In only one case, Abell 2199, was there a significant measured flux. This source is spatially confused with a know blazar in the field of view. The observation is consistent with all emissions being from the blazar.

Source record↗

Airborne Sunphotometer and Solar Spectral Flux Radiometer Measurements During INTEX/ITCT 2004

During the period 12 July - 8 August 2004, the NASA Ames 14-channel Airborne Tracking Sunphotometer (MTS-14) and Solar Spectral Flux Radiometer (SSFR) were operated aboard a Jetstream 31 (J31) aircraft and acquired measurements during nineteen science flights (approx. 53 flight hours) over the Gulf of Maine in support of the INTEX-NA (INtercontinental chemical Transport Experiment-North America) and ITCT (Intercontinental Transport and Chemical Transformation of anthropogenic pollution) field studies. In this paper, we will present results from analyses of those data sets. AATS-14 measures the direct solar beam transmission at fourteen discrete wavelengths (354-2138 nm), and provides instantaneous measurements of aerosol optical depth (AOD) spectra and water vapor column content, in addition to vertical profiles of aerosol extinction and water vapor density during suitable aircraft ascents and descents. SSFR consists of separate nadir and zenith viewing hemispheric FOV sensors that yield measurements of up- and downwelling solar irradiance at a spectral resolution of approx. 8-12 nm over the wavelength range 300-1700 nm. The objectives of the J31-based measurements during INTEX/ITCT were to provide AOD data for the evaluation of MODIS (MODerate-resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectro-Radiometer) AOD retrievals, quantify sea surface spectral albedo (which can contribute the largest uncertainty to satellite aerosol retrievals for low aerosol loading), test closure (consistency) among suborbital results, test chemical-transport models using AOD profiles, and assess regional radiative forcing by combining satellite and suborbital results. Specific J31 flight patterns were designed to achieve these objectives, and they included a mixture of vertical profiles (spiral and ramped ascents and descents) and constant altitude horizontal transects at a variety of altitudes. Additional information is included in the original extended abstract.

Russell, P. B.↗

Performance of an Advanced Stirling Convertor Based on Heat Flux Sensor Measurements

The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower, Inc., and NASA Glenn Research Center. The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot-end and cold-end temperatures, and specified electrical power output for a given heat input. It is difficult to measure heat input to Stirling convertors due to the complex geometries of the hot components, temperature limits of sensor materials, and invasive integration of sensors. A thin-film heat flux sensor was used to directly measure heat input to an ASC. The effort succeeded in designing and fabricating unique sensors, which were integrated into a Stirling convertor ground test and exposed to test temperatures exceeding 700 C in air for 10,000 hr. Sensor measurements were used to calculate thermal efficiency for ASC-E (Engineering Unit) #1 and #4. The post-disassembly condition of the sensors is also discussed.

Wilson, Dcott D.↗

Performance of an Advanced Stirling Convertor Based on Heat Flux Sensor Measurements

The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower, Inc., and NASA Glenn Research Center. The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot-end and cold-end temperatures, and specified electrical power output for a given heat input. It is difficult to measure heat input to Stirling convertors due to the complex geometries of the hot components, temperature limits of sensor materials, and invasive integration of sensors. A thin-film heat flux sensor was used to directly measure heat input to an ASC. The effort succeeded in designing and fabricating unique sensors, which were integrated into a Stirling convertor ground test and exposed to test temperatures exceeding 700 C in air for 10,000 hr. Sensor measurements were used to calculate thermal efficiency for ASC-E (Engineering Unit) #1 and #4. The post-disassembly condition of the sensors is also discussed.

Wilson, Scott D.↗

Crystal microbalance measures condensable molecular fluxes

Quartz crystal quantitatively measures molecular fluxes emanating from and condensing on spacecraft surfaces. Vibrating in a thickness shear mode, the crystal is frequency sensitive to changes in mass on its surface and can measure a fractional monolayer of a condensate.

Stephens, J. B.↗

Uncertainties in turbulent statistics and fluxes of CO2 associated with density effect corrections

Density effect corrections (DEC) are applied to adjust raw CO2 fluxes measured by eddy covariance (EC) systems with open-path gas analyzers. DEC is also required for adjusting the measured CO2 concentration fluctuations to obtain the adjusted CO2 for analyzing turbulent statistics or quantifying fluxes. However, our data show that the power spectra of the DEC-adjusted CO2 are distorted in the high frequency range, as compared with the corresponding spectra of temperature and water vapor density. This contradicts the similarity behavior of scalars, as suggested by Monin-Obukhov similarity theory. It is demonstrated that such a distortion is caused by the DEC-induced spikes in the DEC-adjusted CO2, altering turbulent statistics of CO2 and scalar similarity between CO2 and other scalars. Our results suggest that CO2 fluxes are overestimated by applying DEC especially under high Bowen ratio conditions, potentially leading to substantial uncertainties in long-term ecosystem carbon exchange in dry regions.

Gao, Zhongming↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

FAST Drift Scan Survey for Ηι Intensity Mapping: I. Preliminary Data Analysis

This work presents the initial results of the drift-scan observation for the neutral hydrogen (Hi) intensity mapping survey with the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The data analyzed in this work were collected in night observations from 2019 through 2021. The primary findings are based on 28 hr of drift-scan observation carried out over 7 nights in 2021, which covers 60 deg 2 sky area. Our main findings are, first, our calibration strategy can successfully correct both the temporal and bandpass gain variation over the 4 hr drift-scan observation. Second, the continuum maps of the surveyed region are made with frequency resolution of 28 kHz and pixel area of $_{2.95\,{\mathrm{arcmin}}^{2}}$. The pixel noise levels of the continuum maps are slightly higher than the forecast assuming $T$ sys = 20 K, which are 36.0 mK (for 10.0 s integration time) at the 1050–1150 MHz band, and 25.9 mK (for 16.7 s integration time) at the 1323–1450 MHz band, respectively. Third, the flux-weighted differential number count is consistent with the NRAO-VLA Sky Survey (NVSS) catalog down to the confusion limit ~7 mJy beam –1 . Finally, the continuum flux measurements of the sources are consistent with those found in the literature. The difference in the flux measurement of 81 isolated NVSS sources is about 6.3%. Our research offers a systematic analysis for the FAST Hi intensity mapping drift-scan survey and serves as a helpful resource for further cosmology and associated galaxies sciences with the FAST drift-scan survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Topographic Correction of Geothermal Heat Flux in Greenland and Antarctica

Earth’s thick, polar ice sheets insulate the bedrock beneath them from the colder temperatures at the ice surface. Consequently, the small amount of geothermal heat that Earth’s bedrock releases can have a disproportionate role in controlling ice flow. Geothermal heat flux measurements beneath ice sheets are sparse, and models do not presently account for variable bed topography. Here, we present a simple statistical method for correcting geothermal heat flux models to make them consistent with known subglacial bed topography. This method is based on previous geothermal heat flux measurements across valleys and ridges, and it helps us explore the broader significance of geothermal heat flux variability beneath the Greenland and Antarctic ice sheets. Our method can also be used to estimate the influence of topography on geothermal heat flux in non-ice-covered areas.

William Colgan↗

BOREAS TGB-5 CO2, CH4 and CO Chamber Flux Data Over the NSA

The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB-5) team collected a variety of trace gas concentration and flux measurements at several NSA sites. This data set contains carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) chamber flux measurements conducted in 1994 at upland forest sites that experienced stand-replacement fires. These measurements were acquired to understand the impact of fires on soil biogeochemistry and related changes in trace gas exchange in boreal forest soils. Relevant ancillary data, including data concerning the soil temperature, solar irradiance, and information from nearby un-burned control sites, are included to provide a basis for modeling the regional impacts of fire and climate changes on trace gas biogeochemistry. The data are provided in tabular ASCII files.

Burke, Roger↗

Soil surface CO2 fluxes on the Konza Prairie

The utilization of a soil chamber to measure fluxes of soil-surface CO2 fluxes is described in terms of equipment, analytical methods, and estimate quality. A soil chamber attached to a gas-exchange system measures the fluxes every 5-15 min, and the data are compared to measurements of the CO2 fluxes from the canopy and from the soil + canopy. The soil chamber yields good measurements when operated in a closed system that is ported to the free atmosphere, and the CO2 flux is found to have a diurnal component.

Norman, J. M.↗

Dated soil C–N–P profiles, water quality, and chamber fluxes across Ohio and Michigan wetlands (2024–2025)

This dataset includes dated soil core chemistry (bulk density, phosphorus, nitrogen and carbon concentrations), water quality, and chamber flux measurements collected from wetlands in the Midwest United States—12 sites in Ohio, one site in Indiana, one site in Michigan—collected in the spring or summer of 2024 or 2025, all in (.csv) format. These data were generated to examine how wetland restoration, management activities, and time since restoration affect biogeochemical processes, carbon sequestration, nutrient accumulation, water quality, and greenhouse gas emissions. Specifically, these data aim to investigate how restored wetlands differ from natural wetlands in terms of carbon, nitrogen, phosphorus dynamics, as well as carbon dioxide and methane fluxes. Also included are surface and porewater quality parameters and chamber flux measurements across these different wetlands. Sampling was conducted at various sites representing a range of restoration stages, from about 4 years post-restoration up to 105 years post-restoration, and also includes a natural wetland used as a reference in Michigan. These data can be used to determine carbon sequestration rates, nutrient cycling, and to enhance our understanding of biogeochemical responses to wetland restoration in temperate ecosystems. This data package contains (1) a csv file (Water_Quality.csv) containing water quality data (dissolved organic carbon, total dissolved nitrogen, and temperature) organized by location; (2) a csv file (Soil_C_N_P_Seq.csv) containing carbon, nitrogen, and phosphorus concentrations at each soil level and time of each soil level, as well as their sequestration rates; (3) a csv file (CH4_CO2_Flux.csv) including methane and carbon dioxide fluxes that were measured with a chamber; (4) a file-level metadata (FLMD.csv) file that lists each file contained in the dataset with associated metadata; (5) a data dictionary (DD.csv) file that contains terms/column headers used throughout the files along with a definition, units, and data type; and (6) a locations metadata file (Location_metadata.csv).

Earth Science > Atmosphere > Atmospheric Chemistry↗

Three-Dimensional Model Synthesis of the Global Methane Cycle

A synthesis of the global methane cycle is presented to attempt to generate an accurate global methane budget. Methane-flux measurements, energy data, and agricultural statistics are merged with databases of land-surface characteristics and anthropogenic activities. The sources and sinks of methane are estimated based on atmospheric methane composition and variations, and a global 3D transport model simulates the corresponding atmospheric responses. The geographic and seasonal variations of candidate budgets are compared with observational data, and the available observations are used to constrain the plausible methane budgets. The preferred budget includes annual destruction rates and annual emissions for various sources. The lack of direct flux measurements in the regions of many of these fluxes makes the unique determination of each term impossible. OH oxidation is found to be the largest single term, although more measurements of this and other terms are recommended.

Fung, I.↗

Heat-flux gage measurements on a flat plate at a Mach number of 4.6 in the VSD high speed wind tunnel, a feasibility test (LA28)

The feasibility of employing thin-film heat-flux gages was studied as a method of defining boundary layer characteristics at supersonic speeds in a high speed blowdown wind tunnel. Flow visualization techniques (using oil) were employed. Tabulated data (computer printouts), a test facility description, and photographs of test equipment are given.

Source record↗

Multiwavelength Observations of Strong Flares from the TeV Blazar 1ES 1959+650

Following the detection of strong TeV gamma ray flares from the BL Lac object 1 ES 1959+650 with the Whipple 10 m Cerenkov telescope on 2002 May 16 and 17, we performed intensive target of opportunity radio, optical, X-ray, and TeV ?ray observations from 2002 May 18 to August 14. Observations with the X-ray telescope RossiX-Ray Timing Explorer and the Whipple and HEGRA gamma-ray telescopes revealed several strong flares, enabling us to sensitively test the X-ray--gamma-ray flux correlation properties. Although the X-ray and gamma-ray fluxes seemed to be correlated in general, we found an orphan gamma-ray flare that was not accompanied by an X-ray flare. While we detected optical flux variability with the Boltwood and Abastumani observatories, the data did not give evidence for a correlation of the optical flux variability with the observed X-ray and 7-ray flares. Within statistical errors of about 0.03 Jy at 14.5 GHz and 0.05 Jy at 4.8 GHz, the radio fluxes measured with the University of Michigan Radio Astronomy Observatory stayed constant throughout the campaign; the mean values agreed well with the values measured on 2002 May 7 and June 7 at 4.9 and 15 GHz with the Very Large Array and at 4.8 GHz with archival flux measurements. After describing in detail the radio, optical, X-ray and gamma-ray light curves, and spectral energy distributions (SEDs), we present initial modeling of the SED with a simple synchrotron self- Compton model. With the addition of another TeV blazar with good broadband data, we consider the set of all TeV blazars, to begin to look for a connection of the jet properties to the properties of the central accreting black hole thought to drive the jet. Remarkably, the temporal and special X-ray and gamma-ray emission characteristics of TeV blazars are very similar, even though the mass estimates of their central black holes differ by up to 1 order of magnitude.

Krawczynski, H.↗

A Cavity-Enhanced UV Absorption Instrument for High-Precision, Fast-Time-Response Ozone Measurements

The NASA Rapid Ozone Experiment (ROZE) is a broadbandcavity-enhanced UV absorption instrument for the detection of in situozone (O3).ROZE uses an incoherent LED light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ~104 m. Due to its high-sensitivity and smalloptical cell volume, ROZE demonstratesa 1𝜎precision of 80 pptv (0.1 s) and 31 pptv (1 s), as well as an 𝑒-fold timeresponseof 50 ms. ROZE can be operated in a range of field environments, including low-and high-altitude research aircraft,and is particularly suited toO3vertical flux measurements usingthe eddy covariance technique.ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September2019and validated against a well-established chemiluminescence measurement of O3.Aflight within the marine boundary layer also demonstrated flux measurement capabilities, and we observeda mean O3deposition velocityof 0.029 ± 0.005 cm s–1to the ocean surface.The performance characteristics detailed below make ROZE a robust, versatile instrument for fieldmeasurements of O3.

Rapid Ozone Experiment (ROZE)↗

Integral Plug-Type Heat-Flux Gauge

Integral thermoplug gauge measures flux of heat across specimen of material. New gauge not screwed or welded into place, but instead thermoplug and annulus electrical-discharge-machined (EDM) into specimen material. EDM process leaves no interface between material and thermoplug, thus inherently increasing gauge accuracy by eliminating interface and associated temperature discontinuity. Process also conducive to accurate fabrication of minute gauges.

Liebert, Curt H.↗

Quantitative calculations of helium ion escape fluxes from the polar ionospheres

An attempt is made to reduce the discrepancy between the earlier theoretical model and the recent experimental observations of H(+) outward fluxes for winter and summer hemispheres by improving the theoretical model. The helium photoionization cross sections used are accurate to 10%, the latest solar EUV fluxes measured by the Atmosphere Explorer satellites are incorporated, and the most recent MSIS model of the neutral atmosphere is contained in the model. A range of conditions covering solar cycle, seasonal, and geomagnetic conditions are studied. The results show a maximum H(+) escape flux of 1.4 times 10 to the 7th per sq cm per sec for solar maximum, winter, low magnetic activity conditions, which is within the scatter of the measured fluxes. The computed summer H(+) escape flux is a factor of 20 lower than the winter value. Possible reasons for the slight discrepancy between theory and experiment in summer are discussed.

Raitt, W. J.↗