Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Combination of grazing incidence x-ray fluorescence with x-ray reflectivity in one table-top spectrometer for improved characterization of thin layer and implants on/in silicon wafers

As Grazing Incidence X-ray Fluorescence (GIXRF) analysis does not provide unambiguous results for the characterization of nanometre layers as well as nanometre depth profiles of implants in silicon wafers by its own, the approach of providing additional information using the signal from X-ray Reflectivity (XRR) was tested. As GIXRF already uses an X-ray beam impinging under grazing incidence and the variation of the angle of incidence, a GIXRF spectrometer was adapted with an XRR unit to obtain data from the angle dependent fluorescence radiation as well as data from the reflected beam. A θ-2θ goniometer was simulated by combining a translation and tilt movement of a Silicon Drift detector, which allows detecting the reflected beam over 5 orders of magnitude. HfO{sub 2} layers as well as As implants in Silicon wafers in the nanometre range were characterized using this new setup. A just recently published combined evaluation approach was used for data evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The first X-ray diffraction measurements on Mars

The Mars Science Laboratory landed in Gale crater on Mars in August 2012, and the Curiosity rover then began field studies on its drive toward Mount Sharp, a central peak made of ancient sediments. CheMin is one of ten instruments on or inside the rover, all designed to provide detailed information on the rocks, soils and atmosphere in this region. CheMin is a miniaturized X-ray diffraction/X-ray fluorescence (XRD/XRF) instrument that uses transmission geometry with an energy-discriminating CCD detector. CheMin uses onboard standards for XRD and XRF calibration, and beryl:quartz mixtures constitute the primary XRD standards. Four samples have been analysed by CheMin, namely a soil sample, two samples drilled from mudstones and a sample drilled from a sandstone. Rietveld and full-pattern analysis of the XRD data reveal a complex mineralogy, with contributions from parent igneous rocks, amorphous components and several minerals relating to aqueous alteration. In particular, the mudstone samples all contain one or more phyllosilicates consistent with alteration in liquid water. In addition to quantitative mineralogy, Rietveld refinements also provide unit-cell parameters for the major phases, which can be used to infer the chemical compositions of individual minerals and, by difference, the composition of the amorphous component.

Chemistry↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Enhanced Tracker

We report the study and development of a novel new charged particle detector, a "Quantum Enhanced Tracker" for 3D imaging of charged particle tracks. The proposed detector relies on, and benefits from, the extremely high sensitivity of atoms, prepared in a specific quantum superposition, to external perturbations. Atoms are prepared in a so-called "dark superposition" state, a passing charged particle will disturb this quantum state, allowing atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct imaging of the particle trajectory with high resolution. This method has similarities with Cherenkov detectors where a charged particle produces light along its track, but with the major advantages of enhanced sensitivity due to the low energy required to perturb the engineered quantum state, the ability to amplify the signal using a drive laser passing through the medium, and the ability to provide a 3D track.

Zhang, Shukui↗

Ultraviolet absorption: Experiment MA-059

A technique devised to permit the measurement of atmospheric species concentrations is described. This technique involves the application of atomic absorption spectroscopy and the quantitative observation of resonance fluorescence in which atomic or molecular species scatter resonance radiation from a light source into a detector. A beam of atomic oxygen and atomic nitrogen resonance radiation, strong unabsorbable oxygen and nitrogen radiation, and visual radiation was sent from Apollo to Soyuz. The density of atomic oxygen and atomic nitrogen between the two spacecraft was measured by observing the amount of resonance radiation absorbed when the line joining Apollo and Soyuz was perpendicular to their velocity with respect to the ambient atmosphere. Results of postflight analysis of the resonance fluorescence data are discussed.

Donahue, T. M.↗

High resolution, low energy avalanche photodiode X-ray detectors

Silicon avalanche photodiodes have been fabricated, and their performance as X-ray detectors has been measured. Photon sensitivity and energy resolution were measured as a function of size and operating parameters. Noise thresholds as low as 212 eV were obtained at room temperature, and backscatter X-ray fluorescence data were obtained for aluminum and other light elements. It is concluded that the results with the X-ray detector are extremely encouraging, and the performance is challenging the best available proportional counters. While not at the performance level of either cryogenic silicon or HgI2, these device operate at room temperature and can be reproduced in large numbers and with much larger areas than typically achieved with HgI2. In addition, they are rugged and appear to be indefinitely stable.

Farrell, R.↗

An assessment of natural radionuclides in water of Langat River estuary, Selangor

An estuary is an area that has a free connection with the open sea and it is a dynamic semi-enclosed coastal bodies. Ex-mining, aquaculture and industrial areas in Selangor are the sources of pollutants discharged into the estuary water. Radionuclides are considered as pollutants to the estuary water. Gamma radiations emitted by natural radionuclides through their decaying process may give impact to human. The radiological effect of natural radionuclides which are {sup 226}Ra, {sup 228}Ra, {sup 40}K, {sup 238}U and {sup 232}Th, were explored by determining the respective activity concentrations in filtered water along the Langat estuary, Selangor. Meanwhile, in- situ water quality parameters such as temperature, dissolve oxygen (DO), salinity, total suspended solid (TSS), pH and turbidity were measured by using YSI portable multi probes meter. The activity concentration of {sup 226}Ra, {sup 228}Ra and {sup 40}K were determined by using gamma-ray spectrometry with high-purity germanium (HPGe) detector. The activity concentrations of {sup 226}Ra, {sup 228}Ra and {sup 40}K in samples are in the range of 0.17 - 0.67 Bq/L, 0.16 - 0.97 Bq/L and 1.22 - 5.57 Bq/L respectively. On the other hand, the concentrations of uranium-238 and thorium-232 were determined by using Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF). The thorium concentrations are between 0.17 ppm to 0.28 ppm and uranium concentrations were 0.25 ppm to 0.31 ppm. The results show activity concentrations of radionuclides are slightly high near the river estuary. The Radium Equivalent, Absorbed Dose Rate, External Hazard Index, and Annual Effective Dose of {sup 226}Ra, {sup 228}Ra and {sup 40}K are also studied.

54 ENVIRONMENTAL SCIENCES↗

Signal generation and mixing electronics for frequency-domain lifetime and spectral fluorometry

The present invention additionally comprises a method and apparatus for generating and mixing signals for frequency-domain lifetime and spectral fluorometry. The present invention comprises a plurality of signal generators that generate a plurality of signals where the signal generators modulate the amplitude and/or the frequency of the signals. The present invention uses one of these signals to drive an excitation signal that the present invention then directs and transmits at a target mixture, which absorbs the energy from the excitation signal. The property of fluorescence causes the target mixture to emit an emitted signal that the present invention detects with a signal detector. The present invention uses a plurality of mixers to produce a processor reference signal and a data signal. The present invention then uses a processor to compare the processor reference signal with the data signal by analyzing the differences in the phase and the differences in the amplitude between the two signals. The processor then extracts the fluorescence lifetime and fluorescence spectrum of the emitted signal from the phase and amplitude information using a chemometric analysis.

Cruce, Tommy C.↗

Signal generation and mixing electronics for frequency-domain lifetime and spectral fluorometry

The present invention additionally comprises a method and apparatus for generating and mixing signals for frequency-domain lifetime and spectral fluorometry. The present invention comprises a plurality of signal generators that generate a plurality of signals where the signal generators modulate the amplitude and/or the frequency of the signals. The present invention uses one of these signals to drive an excitation signal that the present invention then directs and transmits at a target mixture, which absorbs the energy from the excitation signal. The property of fluorescence causes the target mixture to emit an emitted signal that the present invention detects with a signal detector. The present invention uses a plurality of mixers to produce a processor reference signal and a data signal. The present invention then uses a processor to compare the processor reference signal with the data signal by analyzing the differences in the phase and the differences in the amplitude between the two signals. The processor then extracts the fluorescence lifetime and fluorescence spectrum of the emitted signal from the phase and amplitude information using a chemometric analysis.

Cruce, Tommy Clay↗

Apollo scientific experiments data handbook

A brief description of each of the Apollo scientific experiments was described, together with its operational history, the data content and formats, and the availability of the data. The lunar surface experiments described are the passive seismic, active seismic, lunar surface magnetometer, solar wind spectrometer, suprathermal ion detector, heat flow, charged particle, cold cathode gage, lunar geology, laser ranging retroreflector, cosmic ray detector, lunar portable magnetometer, traverse gravimeter, soil mechanics, far UV camera (lunar surface), lunar ejecta and meteorites, surface electrical properties, lunar atmospheric composition, lunar surface gravimeter, lunar seismic profiling, neutron flux, and dust detector. The orbital experiments described are the gamma-ray spectrometer, X-ray fluorescence, alpha-particle spectrometer, S-band transponder, mass spectrometer, far UV spectrometer, bistatic radar, IR scanning radiometer, particle shadows, magnetometer, lunar sounder, and laser altimeter. A brief listing of the mapping products available and information on the sample program were also included.

Eichelman, W. F.↗

Data from the Mars Science Laboratory CheMin XRD/XRF Instrument

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity uses a Co tube source and a CCD detector to acquire mineralogy from diffracted primary X-rays and chemical information from fluoresced X-rays. CheMin has been operating at the MSL Gale Crater field site since August 5, 2012 and has provided the first X-ray diffraction (XRD) analyses in situ on a body beyond Earth. Data from the first sample collected, the Rocknest eolian soil, identify a basaltic mineral suite, predominantly plagioclase (approx.An50), forsteritic olivine (approx.Fo58), augite and pigeonite, consistent with expectation that detrital grains on Mars would reflect widespread basaltic sources. Minor phases (each <2 wt% of the crystalline component) include sanidine, magnetite, quartz, anhydrite, hematite and ilmenite. Significantly, about a third of the sample is amorphous or poorly ordered in XRD. This amorphous component is attested to by a broad rise in background centered at approx.27deg 2(theta) (Co K(alpha)) and may include volcanic glass, impact glass, and poorly crystalline phases including iron oxyhydroxides; a rise at lower 2(theta) may indicate allophane or hisingerite. Constraints from phase chemistry of the crystalline components, compared with a Rocknest bulk composition from the APXS instrument on Curiosity, indicate that in sum the amorphous or poorly crystalline components are relatively Si, Al, Mg-poor and enriched in Ti, Cr, Fe, K, P, S, and Cl. All of the identified crystalline phases are volatile-free; H2O, SO2 and CO2 volatile releases from a split of this sample analyzed by the SAM instrument on Curiosity are associated with the amorphous or poorly ordered materials. The Rocknest eolian soil may be a mixture of local detritus, mostly crystalline, with a regional or global set of dominantly amorphous or poorly ordered components. The Rocknest sample was targeted by MSL for "first time analysis" to demonstrate that a loose deposit could be scooped, sieved to <150 microns, and delivered to instruments in the body of the rover. A drilled sample of sediment in outcrop is anticipated. At the time of writing this abstract, promising outcrops are in range and this talk will provide an update on data collected with the CheMin instrument.

Vaniman, David↗

Using NDA Techniques to Improve Safeguards Metrics on Burnup Quantification and Plutonium Content in LWR SNF

Globally, there exists a long history in reprocessing in evaluation of the shipper/receiver difference (SRD) on spent nuclear fuel (SNF) received and processed. Typically, the declared shipper s values for uranium and plutonium in SNF (based on calculations involving the initial manufacturer s data and reactor operating history) are used as the input quantities to the head-end process of the facility. Problems have been encountered when comparing these values with measured results of the input accountability tank contents. A typical comparison yields a systematic bias indicated as a loss of 5 7 percent of the plutonium (Pu) and approximately 1 percent for the uranium (U). Studies suggest that such deviation can be attributed to the non-linear nature of the axial burnup values of the SNF. Oak Ridge National Laboratory and Texas A&M University are co-investigating the development of a new method, via Nondestructive Assay (NDA) techniques, to improve the accuracy in burnup and Pu content quantification. Two major components have been identified to achieve this objective. The first component calculates a measurement-based burnup profile along the axis of a fuel rod. Gamma-ray data is collected at numerous locations along the axis of the fuel rod using a High Purity Germanium (HPGe) detector designed for a wide range of gamma-ray energies. Using two fission products, 137Cs and 134Cs, the burnup is calculated at each measurement location and a profile created along the axis of the rod based on the individual measurement locations. The second component measures the U/Pu ratio using an HPGe detector configured for relatively low-energy gamma-rays including x-rays. Fluorescence x-rays from U and Pu are measured and compared to the U/Pu ratio determined from a destructive analysis of the sample. This will be used to establish a relationship between the measured and actual values. This relationship will be combined with the burnup analysis results to establish a relationship between fission product activity and Pu content. It is anticipated that this new method will allow receiving facilities to make a limited number of NDA, gamma-ray, measurements to confirm the shipper declared values for burnup and Pu content thereby improving the SRD.

Burnup↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Soft X-Ray Scattering from Stripe-Ordered La 2 - x Ba x Cu O 4 Detected by a Transition-Edge Sensor Array Detector

Resonant soft x-ray scattering (RSXS) is a leading probe of valence-band order in materials best known for detecting charge-density-wave order in copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background, which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition-edge-sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La 2 - x Ba x Cu O 4 at the Cu L 3 / 2 edge (932.2 eV) using a TES detector with 1.5-eV resolution, to evaluate its utility for mitigating the fluorescence-background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a five to ten times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES introduces a promising method to reducing background in RSXS studies and may lead to discoveries in materials exhibiting valence-band order that is fluctuating or glassy.

36 MATERIALS SCIENCE↗

Integrated X-ray detection system for determination of nuclear material concentration

An integrated system of X-ray Absorption Spectrometry (XAS), also called L-edge densitometry for uranium (LED) and X-ray Fluorescence spectrometry (XRF) is designed using Monte Carlo simulation for determining concentration of uranium and minor actinides for safeguard. The system can be useful to determination uranium and minor actinide, such as plutonium, neptunium, and etc., concurrently. The equipment is compact compared to the K-edge densitometer with high purity germanium detector which needs liquid nitrogen cooling since a low energy X-ray source is used. The system has been validated from simulation and analysis of the transmitted and reflected spectrum. The concentrations of nuclear material samples are obtained from this study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗