Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The La Mesa Fire: Studies and Observations from 1975 through 2012

In 1996, Swetnam and Baisan stated the following: “The 1977 La Mesa burn was a wake-up call to perhaps the most pressing forest health problem in Southwestern forests—historically anomalous, catastrophic wildfire in the ponderosa pine—created by many decades of fire exclusion.” However, the wake-up call was only momentary and was forgotten until the Dome Fire (1996), Oso Complex Fire (1998), and Cerro Grande Fire (2000) burned lands within the community of Los Alamos, Los Alamos National Laboratory (LANL), Bandelier National Monument (BNM), and Santa Fe National Forest (SFNF). After the Dome Fire, several initiatives were under way to understand the wildland-urban interface and the conditions that have brought the forests of the Pajarito Plateau dangerously close to multiple, large, and intense wildfires. After the Dome Fire, the Interagency Wildfire Management Team was formed, bringing together adjoining agencies to deal with the ever-increasing threat of conflagration that could result in loss of property and human life. This study is about the history before and after the La Mesa Fire—at the time, the first large wildfire on the Pajarito Plateau in over 80 years. It represents 37 years of research and observations that began when management of fire on the Pajarito Plateau was first being explored by BNM. It documents changes in vegetation composition since June 1977 and shows the progression of change in understanding fire’s essential place in the ecosystems of the Pajarito Plateau. The study began in 1975 and 1976, when Loren Potter and I examined previously burned areas to determine a fire frequency for the east Jemez Mountains. We had examined areas of 10 acres or more that had burned at various times, e.g., 1939, 1945, 1950, 1955, 1960, and 1976. A year and a half into the study, the La Mesa Fire ignited on Mesa del Rito, ultimately burning about 15,000 acres of BNM, SFNF, and LANL, including our established plots. After the fire, we set up 20- by 50-meter permanent plots along four ornithological transects established by ornithologist Roland Wauer. Wauer’s transects were mostly in ponderosa pine, with one in mixed conifer and one in the piñon-juniper woodland. Plots within the ponderosa pine were visited in 1977, 1978, 1985, 1992, 1998, 1999, 2010, 2011 and 2012. We mapped the standing trees, photographed each plot, and collected data on the understory components. Transects in the mixed conifer were visited in 1977, 1992, 1999, 2010 and 2012. Plots in the piñon-juniper were visited in 1977, 1999, and 2010 for taking photographs and data years after the fire. Additionally, plots were established in LANL Technical Area 49 as a control to post-fire seeding. We visited these plots in 1977, 1992, and 1998. Ironically, this study ends with another large fire burning over the plots we have followed all these years. In June 2011, the Las Conchas Fire became the largest fire in New Mexico’s history to that time and burned most of the area of the La Mesa Fire and the plots studied over the years. In this report, we summarize information about the vegetation changes within the boundaries of the La Mesa Fire. Thirty-seven years of observations and studies have provided long-term data related to regeneration of trees, water relations of grasses and pines, the influence of seeding with non-native grasses, pyrodendrochronology, and plant succession as related to fire.

54 ENVIRONMENTAL SCIENCES↗

Fire Modeling of a Facility for Combustible Loading

The purpose of this project was to create a fire model of the facility. Results from the model will be used to establish standoff distances from combustible fuel packages in the facility, in order to protect material from a thermal event.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization and Stimulation of Selenium Reducing Microbial Consortia from Real Flue Gas Desulfurization Wastewater Biological Treatment System

Selenium is released into the environment via anthropogenic activities such as coal combustion. The U.S. Environmental Protection Agency’s Effluent Limitation Guideline (ELG) Rule limits the release of selenium species into U.S. waterways. To meet the ELG limit for selenium, coal-fired power plants must treat the wastewater produced by the flue gas desulfurization (FGD) systems. Selenium removal is of interest because small changes of the concentrations of selenium in the environment can cause detrimental ecological consequences. Biological treatment is used to remediate this wastewater, but little is known about the individual species in the microbial consortium that reduce toxic water-soluble selenium oxyanions to insoluble elemental selenium. To optimize current biological treatment capabilities of this water, the selenium-reducing capabilities must be leveraged. In order to do so, the selenium-reducing bacteria (SeRB) in biological treatment systems must be characterized. This study will be the first to characterize the microbial consortia from a real FGD WW biological treatment system and provide insights on how to better achieve selenium removal via biological treatment. This work will provide insights into the microorganisms predominantly responsible for the reduction of selenium oxyanions in FGD wastewater biological treatment systems, which can be used to better optimize more efficient biological treatment strategies of this industrial waste.

geomicrobiology↗

Low Frequency Electromagnetic Pulse and Explosions

This paper reviews and summarizes prior work related to low frequency (< 100 Hz) EMP (ElectroMagnetic Pulse) observed from explosions. It focuses on how EMP signals might, or might not, be useful in monitoring underground nuclear tests, based on the limits of detection, and physical understanding of these signals. In summary: (1) Both chemical and nuclear explosions produce an EMP. (2) The amplitude of the EMP from underground explosions is at least two orders of magnitude lower than from above ground explosions and higher frequency components of the signal are rapidly attenuated due to ground conductivity. (3) In general, in the near field, that is distances (r) of less than 10s of kilometers from the source, the amplitude of the EMP decays approximately as 1/r{sup 3}, which practically limits EMP applications to very close (<{approx}1km) distances. (4) One computational model suggests that the EMP from a decoupled nuclear explosion may be enhanced over the fully coupled case. This has not been validated with laboratory or field data. (5) The magnitude of the EMP from an underground nuclear explosion is about two orders of magnitude larger than that from a chemical explosion, and has a larger component of higher frequencies. In principle these differences might be used to discriminate a nuclear from a chemical explosion using sensors at very close (<{approx}1 km) distances. (6) Arming and firing systems (e.g. detonators, exploding bridge wires) can also produce an EMP from any type of explosion. (7) To develop the understanding needed to apply low frequency EMP to nuclear explosion monitoring, it is recommended to carry out a series of controlled underground chemical explosions with a variety of sizes, emplacements (e.g. fully coupled and decoupled), and arming and firing systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cooperative Education

M-3 Focused Experiments is a group at Los Alamos National Lab (LANL) and is under the Dynamic Experiments Division. Their work surrounds the diagnostics and study of explosives and their interaction with materials. The data collected is used to better understand the erratic nature of explosions and high velocity projectiles. Through better comprehension of this science, the overall national security will be improved while innovations are made along the way. Despite the strong drive for research and development, the lab holds safety above all else and constantly updates procedures to protect LANL employees and their environment. At any time, there are multiple projects going on at once within the team and I am tasked with assisting the Firing Site Leaders and various research diagnosticians in any way possible with the setup, testing, and execution of data collection for each experiment. Such data includes velocity, fragmentation characteristics, and the spread of energy across the material to name a few. During my summer employment with the lab, my main goal is to maintain a questioning attitude and learn as much possible about the research and development side of science and engineering. Throughout the duration of the Co-op, many experiments will take place at specially designed firing sites which is where I will be spending most of my time.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Performance of a Surface Barrier for Waste Isolation and Flux Reduction at the Hanford Site - 16099

Based on the knowledge gained from a decade of laboratory, field, and numerical studies, the Prototype Hanford Barrier (PHB) was designed and constructed between late 1993 and late 1994 over the 216-B-57 Crib in the 200-BP-1 Operable Unit at the Hanford Site. The PHB has been monitored since 1994 to evaluate the physical, hydrologic, and ecological performance. Two stress tests were carried out in the past: 1) an enhanced (about 3 times the multi-year average of 160 mm/year) precipitation test from water year (WY) 1995 to WY1997, which included simulated 1000-year return, 24-hour rainstorms in March of each year, and 2) a controlled fire test in 2008. The purpose of this article is to present the main findings of the PHB demonstration since 1994. From 1994 to 2013-during which time the barrier experienced 3 years of enhanced precipitation, three 1000-year return, 24-hour simulated rainstorms, and a controlled fire-the PHB limited drainage to well below the 0.5 mm yr{sup -1} design criterion and had minimal erosion. Although the test period represents only 2% of the design life, the observations suggest the PHB is robust enough to control drainage and isolate subsurface contaminants. Future barrier performance will depend on barrier stability and hydrology. Given the 19-year record of successful performance and considering all processes and mechanisms that could degrade barrier stability and hydrology in the future, the results suggest that the PHB is very likely to perform for at least the remainder of its 1000-year design life. This conclusion is based on two assumptions: 1) the exposed sub-grade receives protection against erosion and 2) institutional controls prevent inadvertent human activity on the barrier. The findings at the PHB are useful for the design and monitoring of future surface barriers at Hanford and elsewhere. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crashworthiness Models for Automotive Batteries - Report on Project 2088-A031-15 for DOT/NHTSA

Safety is a key element of any device designed to store energy, in particular electrochemical batteries, which convert energy of chemical reactions to electrical energy. Safety considerations are especially important when applied to large automotive batteries designed for propulsion of electric vehicles (EV). The high amount of energy stored in EV battery packs translates to higher probability of fire in case of severe deformation of battery compartment due to automotive crash or impact caused by road debris. While such demand for safety has resulted in heavier protection of battery enclosure, the mechanisms leading to internal short circuit due to deformation of the battery are not well understood even on the level of a single electrochemical cell. Moreover, not all internal shorts result in thermal runaway, and thus a criterion for catastrophic failure needs to be developed. This report summarizes the effort to pinpoint the critical deformation necessary to trigger a short via experimental study on large format automotive Li-ion cells in a rigid spherical indentation configuration. Cases of single cells and cell stacks undergoing indentation were investigated. Mechanical properties of cell components were determined via experimental testing and served as input for constitutive models of Finite Element (FE) analysis. The ability of the model to predict the behavior of cell(s) under spherical indentation and to predict failure leading to internal short circuit was validated against experiments. The necessity of resolving pairs of negative and positive electrodes in the FE formulation is clearly demonstrated by comparing layer-resolved simulations with simulations involving batteries with homogenized material properties. Finally, a coupled solution of electrochemical-electrical-thermal (EET) problem on a Nissan Leaf battery module was demonstrated towards the goal of extending the simulations to module level.

25 ENERGY STORAGE↗

Crashworthiness Models for Automotive Batteries

Safety is a key element of any device designed to store energy, particularly of electrochemical batteries, which convert energy of chemical reactions to electrical energy. Safety considerations are especially important when applied to large automotive batteries designed for propulsion of electric vehicles (EV). The high amount of energy stored in EV battery packs translates to higher probability of fire in case of severe deformation of battery compartment due to automotive crash or impact caused by road debris. While such demand for safety has resulted in heavier protection of battery enclosure, the mechanisms leading to internal short circuit due to deformation of the battery are not well understood even on the level of a single electrochemical cell. Moreover, not all internal shorts result in thermal runaway, and thus a criterion for catastrophic failure needs to be developed. This report summarizes the effort to pinpoint the critical deformation necessary to trigger a short via experimental study on large format automotive Li-ion cells subjected to large deformations as those occurring in deformation of battery module or pack. Mechanical properties of cell components were determined via experimental testing and served as input for constitutive models of Finite Element (FE) analysis. It has been rationalized that long-range stress fields occurring in spherical indentation of battery modules would trigger different deformation and failure scenarios compared to indentation of a single cell supported by a rigid flat surface. In order to investigate large deformations characteristic of battery module, a custom experimental set up has been built where the pouch cell was deformed against a compliant backing, which was represented by a ballistic clay. Experiments were also conducted on deformation of stacks of 10 pouch cells, - configuration representing half-module in Ford Focus EV battery pack without cooling plates and structural components. Comparison of the results shows promise for the compliant backing setup for safety evaluation of battery cells under more realistic conditions compared to indentation of single cell against undeformable backing where compression and electrode particle penetration through separator could be the major mechanism for short circuit.

25 ENERGY STORAGE↗

Crashworthiness Models for Automotive Batteries (NHTSA-ORNL 2018)

Safety is a key element of any device designed to store energy.Electrochemical batteries convert energy of chemical reactions to electrical energy. Safety considerations are especially important when applied to large automotive batteries designed for propulsion of electric vehicles (EV). The high amount of energy stored in EV battery packs translates to higher probability of fire in case of severe deformation of battery compartment due to automotive crash or impact caused by road debris. While such demand for safety has resulted in heavier protection of battery enclosure, the mechanisms leading to internal short circuit due to deformation of the battery are not well understood even on the level of a single electrochemical cell. Moreover, not all internal shorts result in thermal runaway, and thus a criterion for catastrophic failure needs to be developed.

25 ENERGY STORAGE↗

Flammable Gas Generation and Control at the Idaho Completion Project Legacy Combustible Gas Generation - 20191

On April 11, 2018, four drums containing transuranic waste at the Idaho National Laboratory underwent over-pressurization, ejecting their lids and spreading radiological waste within a facility. An investigation has found that waste in the drums generated methane gas, which contributed to the event. Subsequent to the investigation, the potential for drums to have methane and other flammable analytes whose concentrations could approach or exceed the lower flammability limit (LFL) and the adequacy of the controls to prevent or mitigate a possible deflagration was evaluated. An extensive review of the historical records was performed to determine how many drums exceed the LFL. The historical record identified a small quantity of drums that exceeded the LFL for xylene, hydrogen, and methane. The primary codified applicable code or standard for handling drums is 29 CFR 1910.120 (j) 'Handling Drums and Containers.' It is used throughout the commercial and government sector. This code is integrated throughout the Fluor Idaho safety management programs and procedures to control the Standard Industrial Hazards (SIHs) associated with drum and container handling. Example requirements include: - Drums and containers are inspected, and their integrity assured prior to being moved. - Site operations are organized to minimize the amount of drum or container movement. - When there is a reasonable possibility of flammable atmospheres being present, material handling equipment and hand tools are of the type to prevent sources of ignition. Drums and containers under pressure, as evidenced by bulging or swelling, are not moved until the cause for excess pressure is determined and appropriate containment procedures have been implemented to protect employees from explosive relief of the drum. Drums which exceed the WIPP FGA limit have NCRs associated with them. Once a drum fails flammable gas sampling, an NCR is initiated. The NCR drives placement into NCR dense pack rows. A standing order drives placement of the FGA failures to a single planer segregation location. These drums are not allowed for further processing or shipment until the NCR has been cleared. Once in the single planer rows, follow-up FGA testing is performed by CCP. The NCR is dispositioned by follow-up sampling occurring after adequate time has been provided for the gas to diffuse through the filter assembly, or, in some cases, the drums are repackaged into additional drums to reduce the source term. To date, the ICP project has performed approximately 1.5 million drums moves without a deflagration event due to combustible gas generation. Flammable gas generation in a transuranic waste drum is not unique to the ICP but is common across the DOE complex. Based on the experience at Idaho, application of industry standards is sufficient to control the risk of drum deflagration due to drum movements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 1607-F1 Sanitary Sewer System (124-F-1) and the 100-F-26:8 (1607-F1) Sanitary Sewer Pipelines Waste Sites, Waste Site Reclassification Form 2004-130

The 1607-F1 Sanitary Sewer System (124-F-1), consisted of a septic tank, drain field, and associated pipelines that received sanitary waste water from the 1701-F Gatehouse, 1709-F Fire Station, and the 1720-F Administrative Office via the 100-F-26:8 pipelines. The septic tank required remedial action based on confirmatory sampling. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F-26:8 pipelines↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 72 Outdoor Live Fire Range Safety Upgrades Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction and upgrade activities in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed upgrades are intended to improve range safety to help fulfill the mission requirements of maintaining a trained and qualified armed Protective Force.

54 ENVIRONMENTAL SCIENCES↗

Handling and Treatment of Sodium-Potassium Alloy (NaK) after the Loss of Key Personnel - 19002

In September 2010, during cleanup and removal efforts associated with a glovebox containing a sodium-potassium alloy (NaK) cooling system, a NaK reaction event occurred. Near the end of the evolution, which was at a Materials and Fuels Complex (MFC) research facility at the Idaho National Laboratory, a 2 to 3-ounce sample of NaK was being transferred from a metal can to a polyethylene bottle so it could be sent to the disposal outlet for verification analysis. During the transfer, a reaction of the NaK with ambient air was observed in both the metal can and sample container. The potential for a reaction was identified during the planning of this activity and mitigating steps were included in the procedures. In response, the two containers were flooded with argon, closed, and observed overnight. No additional reaction was noted. The sample container and metal can were packaged into a 10-gallon drum and transferred to a permitted storage location pending disposal. While the other containers generated from the deactivation and decommissioning activity were sent off-site for disposal, the 10-gal drum remained due to concerns by a staff specialist that the material could contain potassium superoxide (KO{sub 2}) as a result of the reaction event. The intent at that time was to treat the NaK in a Resource Conservation and Recovery Act (RCRA)-permitted treatment facility at MFC, instead of sending it off-site for disposal. The container was labeled, inspected, and managed as a hazardous waste. Due to the complexities associated with safely handling and treating NaK and KO{sub 2}, the container remained in storage. Treatment and disposal of the NaK and KO{sub 2} container was revisited in 2016, when researchers and chemists were consulted regarding the potential for superoxide formation and the best means to safely store and treat the container. The facility came to realize that due to the retirements of key personnel, it needed to provide current employees operational experience with the handling and treatment of NaK. An outside company was identified and contracted to provide training and consulting services. Several Battelle Energy Alliance, Inc. (BEA) personnel then attended an alkali metals safety training class. The training course provided participants with classroom and hands-on instruction associated with: - Hazards associated with handling and using sodium and NaK; - Proper personal protection equipment, spill control techniques, and first aid; - Common design approaches for buildings, systems, and equipment used to contain sodium and NaK; - What to expect in the event of a water reaction and how to respond; - How to properly prepare for a fire and contain/extinguish small metal fires; - A hands-on demonstration of NaK reaction and controls. Following the training, a procedure was developed to open the container, and inspect and treat the NaK. In June 2017, facility operations personnel successfully completed the inspection and treatment of the NaK drum, eliminating the legacy liability. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Evaluation of joint resistance in SSC Rutherford type cable splices for Torus magnet for the Jefferson Lab 12 GeV Upgrade

The Hall B 3.6-T superconducting torus magnet is being designed and built as part of the Jefferson Lab 12-GeV upgrade. The magnet consists of six trapezoidal coils connected in series, with an operating current of 3770 A. The magnet and the joints (or splices) connecting the coils are all conduction cooled by supercritical 4.6-K helium. This paper studies the design and manufacturing process of the splices made between two SSC Rutherford-type cables and discusses the tests performed to evaluate the performance of the splices under varying incident magnetic fields.

Ghoshal, Probir K.↗

Causal Analysis Report for Thunder Range Block VIII Test - Management Concern

From July 24th -27th, 2018, Sandia National Laboratories (SNL) was conducting a series of explosive tests (referred to as Block VIII Tests) at Thunder Range. Thunder Range is an explosive testing range located on Kirtland Air Force Base and operated by SNL. The testing occurred on Range 7, a fragmentation range that is authorized for activities up to a maximum of 2,000 pounds net explosive weight (NEW). The maximum NEW for the Block VIII tests was 114 lbs. The specific management concern is that although the Thunder Range team identified controls to provide protection for essential personnel, those controls were not adequately evaluated before testing occurred. There were several controls in place at Thunder Range when the block VW test was executed. Engineered controls including Fire Control Point (FCP) placement, FCP structure design, and administrative controls involving communications. These controls were in place but not thoroughly evaluated for adequacy in meeting requirements related to sound pressure and fragments before the test was executed. Compliance with the remaining requirements was achieved. The lack of evaluation did not result in harm to personnel, equipment, or structures but was deemed as an opportunity to further understand how compliance with DOE-STD-1212-2012 could be better achieved with defensible evidence. The information provided in the remainder of this report discusses these controls and the deficiencies that contributed to this management concern.

42 ENGINEERING↗

Elucidating Arsenic and Selenium Speciation in Coal Fly Ashes

Coal fly ash (CFA) is produced during the coal combustion process and contains trace elements (<100 ppm) including selenium (Se) and arsenic (As), both detrimental for environmental and human health. Existing management strategies for CFAs involve disposal in landfills and ash ponds, as well as beneficial usage in other applications such as in concrete. Both the direct disposal and beneficial usage of CFA raise concerns for environmental hazards due to the potential leaching of Se and As. CFAs were classified as reusable material by the U.S. Environmental Protection Agency (EPA) with the first federal regulation (Disposal of Coal Combustion Residuals from Electric Utilities, CCR) for its disposal established six years ago. During coal combustion process, parameters such as furnace firing type, emissions controls, coal rank, use of additives, and particulate matter controls, could contribute to significant variability in As/Se concentrations and their speciation. Although there have been a handful of studies on As/Se speciation on small sets of samples, they do not fully represent the current state of coal-fired electrical generating units. Little information exists on the detailed speciation (e.g. oxidation state, complexation state) of As/Se in large set of fly ash samples. To better investigate the role of the potential contributing parameters, a large-scale survey study with representative samples of typical coal source and combustion conditions is highly desired. The overall goal of this research is to systematically characterize As and Se speciation of representative coal fly ash samples using state-of-the-art synchrotron based spectroscopic and microscopic techniques, in order to develop a correlation between coal source/type, operation condition, As/Se speciation, and As/Se mobility. A detailed survey study was conducted documenting the current state-of-knowledge on fossil power generating units as a function of coal type/source, operating conditions, environmental control systems, additive use, and fly ash handling methods. Based on this survey, a matrix of fly ash samples representing a range of conditions were chosen and collected. The collected ash samples were analyzed for bulk characteristics such as elemental composition, microstructure, chemical and mineralogical composition, surface area, and particle size distribution. State-of-the-art synchrotron X-ray microscopy and spectroscopy techniques were applied to reveal the molecular scale speciation information of As and Se, such as oxidation state, association with other elements/minerals, and complexation states.

01 COAL, LIGNITE, AND PEAT↗