Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FeN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development and characterization of PdCr temperature-compensated wire resistance strain gage

A temperature-compensated resistance static strain gage with potential to be used to 600 C was recently developed. Gages were fabricated from specially developed palladium-13 w/o chromium (Pd-13Cr) wire and platinum (Pt) compensator. When bonded to high temperature Hastelloy X, the apparent strain from room temperature to 600 C was within 400 microstrain for gages with no preheat treatment and within 3500 microstrain for gages with 16 hours prestabilization at 640 C. The apparent strain versus temperature relationship of stabilized PdCr gages were repeatable with the reproducibility within 100 microstrain during three thermal cycles to 600 C and an 11 hours soak at 600 C. The gage fabrication, construction and installation is described. Also, the coating system used for this compensated resistance strain gage is explained. The electrical properties of the strain sensing element and main characteristics of the compensated gage including apparent strain, drift and reproducibility are discussed.

Lei, Jih-Fen↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 800 C

A temperature compensated static strain gage, which is fabricated from palladium-13w/o chromium (Pd13Cr) alloy and a platinum (Pt) compensator, is being developed and was tested over a temperature range to 800 C at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 800 C than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4w/o zirconia overcoating. Test results to 800 C indicate apparent strain variations of less than 300 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. Apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

The apparent strain stability and repeatability of a BCL3 resistance strain gage

Experiments were conducted at NASA-Lewis to study the effect of microstructural instability on the apparent strain stability and reproducibility of a BCL3 resistance strain gage. The resistance drift of the gage at various temperatures in the phase transition temperature range (PTTR) was measured. The effects of the heating and cooling rates with which the gage passed through the PTTR on the apparent strain characteristics of the gage were also studied. BCL3 gage, like other Fe-Cr-Al based gages, exhibited apparent strain instability in the temperature range of 700 to 1100 F due to the reversible microstructural transition the gage materials experienced in this temperature range. The BCL3 gage had a maximum apparent strain drift in the neighborhood of 770 F with an average drift rate of approx. -440 microstrain/hr in 2 hrs. The use of the BCL3 gage as well as other Fe-Cl-Al based gages for static strain measurements within the PTTR should be avoided unless the time durations in the PTTR are small enough to introduce a neglible drift. The microstructure transition that the BCL3 gage underwent occurred in the temperature range of 750 to 1050 F during heating and around 1000 to 800 F during cooling. The heating rate, and, in particular, the cooling rate with which the gage passed through the PTTR affected the shape and the repeatability of the apparent strain curve of the gage.

Lei, Jih-Fen↗

PdCr based high temperature static strain gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium-13 wt pct chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least 1000 microstrain. The apparent strain varied within 300 microstrain from room temperature to 800 C with a reproducibility within 50 microstrain between thermal cycles to 800 C. The sputtered thin film PdCr strain gage, whose size was 8 x 8 mm and 10 microns thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 C.

Lei, Jih-Fen↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 1500 F

A temperature compensated static strain gauge, which is fabricated from Pd13Cr alloy and a Pt compensator, is being developed and has been tested over a temperature range to 1500 F at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 500 F than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4 wt pct zirconia overcoating. Test Results to 1500 F indicate apparent strain variations of less than 250 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. The apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Pd/Cr Strain Gauges For High Temperatures

Temperature-compensated Pd/Cr electrical-resistance strain gauges measure static strains in combustors, blades, and vanes of gas turbine engines. Made of alloy of 87 weight percent Pd and 13 weight percent Cr. Microstructure highly stable; undergoes no transformation of phase between ambient temperature and 1,000 degrees C. Gives highly repeatable readings with low drift at temperatures from ambient to 600 degrees C.

Lei, Jih-Fen↗

Protective Coats For High-Temperature Strain Gauges

Addition of some rare-earth oxides to prior alumina (only) coating material increases maximum service temperature of palladium/chromium-wire strain gauges. Pd/Cr wires used at temperatures up to 800 degrees C without excessive drift in electrical resistance. Oxides used: zirconia (ZrO2), yttria (Y2O3), ceria (CeO2), and hafnia (HfO2). Addition of one of these oxides to decrease oxidation of wire at high temperature. Protection against oxidation increases with concentration of rare-earth oxide. Addition of ZrO2 at 4 to 6 weight percent or Y2O3 at 1 weight percent results in smallest drift in electrical resistance.

Lei, Jih-Fen↗

Palladium-chromium static strain gages for high temperatures

An electrical resistance strain gage that can provide accurate static strain measurement to a temperature of 1500 F or above is being developed both in fine wire and thin film forms. The gage is designed to be temperature compensated on any substrate material. It has a dual element: the gage element is a special alloy, palladium-13wt percent chromium (PdCr), and the compensator element is platinum (Pt). Earlier results of a PdCr based wire gage indicated that the apparent strain of this gage can be minimized and the repeatability of the apparent strain can be improved by prestabilizing the gage on the substrate for a long period of time. However, this kind of prestabilization is not practical in many applications and therefore the development of a wire gage which is prestabilized before installation on the substrate is desirable. This paper will present our recent progress in the development of a prestabilized wire gage which can provide meaningful strain data for the first thermal cycle. A weldable PdCr gage is also being developed for field testing where conventional flame-spraying installation can not be applied. This weldable gage is narrower than a previously reported gage, thereby allowing the gage to be more resistant to buckling under compressive loads. Some preliminary results of a prestabilized wire gage flame-sprayed directly on IN100, an engine material, and a weldable gage spot-welded on IN100 and SCS-6/(beta)21-S Titanium Matrix Composite (TMC), a National Aero-Space Plane (NASP) structure material, will be reported. Progress on the development of a weldable thin film gage will also be addressed. The measurement technique and procedures and the lead wire effect will be discussed.

Lei, Jih-Fen↗

Palladium-chromium static strain gage for high temperature propulsion systems

The present electrical strain gage for high temperature static strain measurements is in its fine-wire and thin-film forms designed to be temperature-compensated on any substrate material. The gage element is of Pd-Cr alloy, while the compensator is of Pt. Because the thermally-induced apparent strain of this compensated wire strain gage is sufficiently small, with good reproducibility between thermal cycles to 800 C, output figures can be corrected within a reasonable margin of error.

Lei, Jih-Fen↗

High temperature static strain measurement with an electrical resistance strain gage

An electrical resistance strain gage that can supply accurate static strain measurement for NASP application is being developed both in thin film and fine wire forms. This gage is designed to compensate for temperature effects on substrate materials with a wide range of thermal expansion coefficients. Some experimental results of the wire gage tested on one of the NASP structure materials, i.e., titanium matrix composites, are presented.

Lei, Jih-Fen↗

High-Temperature Resistance Strain Gauges

Resistance strain gauges developed for use at high temperatures in demanding applications like testing aircraft engines and structures. Measures static strains at temperatures up to 800 degrees C. Small and highly reproducible. Readings corrected for temperature within small tolerances, provided temperatures measured simultaneously by thermocouples or other suitable devices. Connected in wheatstone bridge.

Lei, Jih-Fen↗

More About High-Temperature Resistance Strain Gauges

Two reports present additional information on electrical-resistance strain gauges described in "High-Temperature Resistance Strain Gauges" (LEW-15379). For protection against oxidation at high temperatures, gauges covered, by flame spraying, with coats of alumina containing up to 1 weight percent of yttria or, perferably, containing 4 to 6 weight percent of zirconia.

Englund, D. R.↗

High temperature strain measurement with a resistance strain gage

A PdCr based electrical resistance strain gage was demonstrated in the laboratory to be a viable sensor candidate for static strain measurement at high temperatures. However, difficulties were encountered while transferring the sensor to field applications. This paper is therefore prepared for recognition and resolution of the problems likely to be encountered with PdCr strain gages in field applications. Errors caused by the measurement system, installation technique and lead wire attachment are discussed. The limitations and some considerations related to the temperature compensation technique used for this gage are also addressed.

Lei, Jih-Fen↗

Evaluation of Pd-Cr Wires for Strain Gage Application

A newly developed alloy, palladium-13 weight percent chromium (Pd13Cr), was identified by United Technologies Research Center under a NASA contract to be the best material for high temperature strain gage applications. An electrical resistance strain gage that can provide accurate static strain measurement to a temperature higher than that of a commercially available gage is urgently needed in aerospace and aeronautics research. A strain gage made of a 25.4 micron (1 mil) diameter Pd13Cr wire has been recently demonstrated to be usable for static strain measurements to 800 C. This compares to the 400 C temperature limit of the commercially available strain gages. The performance of the Pd-Cr gage, however, strongly depends on the quality of the Pd13Cr wire. Four batches of Pd-Cr wires purchased from three different manufacturers were therefore evaluated to determine the best source of the wire for strain gage applications. The three suppliers were Precious Metal Institute in China, Sigmund Cohn Co., and G & S Titanium, Inc. in the United States. Two batches of wires obtained from Previous Metal Institute in 1987 and 1992, respectively are referred to herein as China87 and China92 wires. The mechanical, chemical and electrical properties of these wires, both as-received and after high temperature exposures at 800 C for 50 hours were analyzed. The elastic modulus and the failure strength of the wires were evaluated using a tensile test machine equipped with a laser speckle strain measurement system. The chemical and microstructural properties of the wires were inspected using a plasma atomic emission spectrometer and a scanning electron microscope (SEM) equipped with an energy dispersive X-ray spectroscope (EDS). The electrical stability and repeatability of the wires were determined by measuring the electrical resistance of the wires during three thermal cycles to 1000 C and a ten-hour soak at 1000 C. As a result of this study, the wire which has the highest strength, the least impurities content, the best oxidation resistance and the best electrical stability will be selected for upcoming strain gage applications.

Lei, Jih-Fen↗

Advances in Thin Film Sensor Technologies for Engine Applications

Advanced thin film sensor techniques that can provide accurate surface strain and temperature measurements are being developed at NASA Lewis Research Center. These sensors are needed to provide minimally intrusive characterization of advanced materials (such as ceramics and composites) and structures (such as components for Space Shuttle Main Engine, High Speed Civil Transport, Advanced Subsonic Transports and General Aviation Aircraft) in hostile, high-temperature environments and for validation of design codes. This paper presents two advanced thin film sensor technologies: strain gauges and thermocouples. These sensors are sputter deposited directly onto the test articles and are only a few micrometers thick; the surface of the test article is not structurally altered and there is minimal disturbance of the gas flow over the surface. The strain gauges are palladium-13% chromium based and the thermocouples are platinum-13% rhodium vs. platinum. The fabrication techniques of these thin film sensors in a class 1000 cleanroom at the NASA Lewis Research Center are described. Their demonstration on a variety of engine materials, including superalloys, ceramics and advanced ceramic matrix composites, in several hostile, high-temperature test environments are discussed.

Lei, Jih-Fen↗

High-temperature Strain Sensor and Mounting Development

This report describes Government Work Package Task 29 (GWP29), whose purpose was to develop advanced strain gage technology in support of the National Aerospace Plane (NASP) Program. The focus was on advanced resistance strain gages with a temperature range from room temperature to 2000 F (1095 C) and on methods for reliably attaching these gages to the various materials anticipated for use in the NASP program. Because the NASP program required first-cycle data, the installed gages were not prestabilized or heat treated on the test coupons before first-cycle data were recorded. NASA Lewis Research Center, the lead center for GWP29, continued its development of the palladium-chromium gage; NASA Langley Research Center investigated a new concept gage using Kanthal A1; and the NASA Dryden Flight Research Center chose the well-known BCL-3 iron-chromium-aluminum gage. Each center then tested all three gages. The parameters investigated were apparent strain, drift strain, and gage factor as a function of temperature, plus gage size and survival rate over the test period. Although a significant effort was made to minimize the differences in test equipment between the three test sites (e.g., the same hardware and software were used for final data processing), the center employed different data acquisition systems and furnace configurations so that some inherent differences may be evident in the final results.

Williams, W. Dan↗

Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

Lei, Jih-Fen↗

Thin Film Sensors for Minimally-Intrusive Measurements in Harsh High Temperature Environment

Advanced thin film sensors are being developed to provide accurate surface temperature, heat flux and strain measurements for components used in hostile propulsion environments. These sensors are sputter deposited and microfabricated directly onto the test articles with no additional bonding agent. The thickness of the sensors is only a few micrometers which creates minimal disturbance of the gas flow over the test surface. Thus thin film sensors have the advantage over conventional wire- based sensors by providing minimally intrusive measurement and having a faster response. These thin film sensors are being developed for characterization of advanced materials and structures in hostile, high-temperature environments, and for validation of design codes. This paper presents the advances of three high temperature thin film sensor technologies developed at NASA Lewis Research Center: thermocouples, heat-flux gages and strain gages. The fabrication techniques of these thin film sensors which include physical vapor deposition, photolithography patterning and lead Wire attachment are described. Sensors demonstrations on a variety of engine materials, including superalloys, ceramics and advanced ceramic matrix composites, in several hostile, high-temperature test environments are presented. The advantages and limitations of thin film sensor technology are also discussed.

Lei, Jih-Fen↗