Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Predicting Flaw-Induced Resonance Spectrum Shift with Theoretical Perturbation Analysis

Resonance inspection is an emerging non-destructive evaluation (NDE) technique which uses the resonance spectra differences between the good part population and the flawed parts to identify anomalous parts. It was previously established that finite-element (FE)-based modal analysis can be used to predict the resonance spectrum for an engineering scale part with relatively good accuracy. However, FE-based simulations can be time consuming in examining the spectrum shifts induced by all possible structural flaws. This paper aims at developing a computationally efficient perturbation technique to quantify the frequency shifts induced by small structural flaws, based on the FE simulated resonance spectrum for the perfect part. A generic automotive connecting rod is used as the example part for our study. The results demonstrate that the linear perturbation theory provides a very promising way in predicting frequency changes induced by small structural flaws. As the flaw size increases, the discrepancy between the perturbation analysis and the actual FE simulation results increases due to nonlinearity, yet the perturbation analysis is still able to predict the right trend in frequency shift.

Acoustics↗

Measurement of electron density in complex plasmas of the PK-3 plus apparatus on the International Space Station

Dust particles in discharge are often levitated in a sheath region rather than in bulk plasma under gravitational conditions (on Earth). Gravity compresses dust clouds, and the gravitational force restricts the motion of the dust particles. Microgravity gives the plasmas, including dust particles, so-called complex (dusty) plasmas, where dust particles are embedded in a completely charge-neutral region of the bulk plasma. The dust cloud, as an uncompressed strongly-coupled Coulomb system, corresponds to an atomic model with physical phenomena, e.g., crystallization, phase transition, and so on. Since the phenomena are tightly connected to plasma states expressed by plasma parameters, it is significant to estimate the plasma parameters, such as electron density and temperature. The present work shows the electron density measured by the frequency shift probe in the apparatus for microgravity experiments currently boarding on the International Space Station (PK-3 plus). The frequency shift probe measurement gave electron density in the order of 10{sup 8} cm{sup -3} as a typical value in the apparatus, and demonstrated the detection of electrons in plasmas with dust particles. The spatial distribution profile of the electron density obtained in this measurement presents an aspect for the void formation of dust clouds under microgravity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stimulated concentration (diffusion) light scattering on nanoparticles in a liquid suspension

A nonlinear growth of the light scattering intensity has been observed and the frequency shift of the spectral line of scattered light has been measured in light backscattered in suspensions of diamond and latex nanoparticles in water. The shift corresponds to the HWHM of the line of spontaneous scattering on particles. We may conclude that there exists stimulated concentration (diffusion) light scattering on variations of the particle concentration, which is also called the stimulated Mie scattering. In a fibre probe scheme, the growth of the shift of the scattered spectral line is observed with an increase in the exciting beam power. The variation of the frequency shift with an increase in the exciting power is explained by convection in liquid. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microcomputerized electric field meter diagnostic and calibration system

A computerized field meter calibration system which includes an apparatus for testing the calibration of field meters normally utilized for measuring electromagnetic field potentials is described. A reference voltage is applied to the field meter for causing signals to be produced on the output terminals thereof. A bank of relays is provided for selectively connecting output terminals of the field meter to a multiplexer by means of a digital voltmeter and an oscilloscope. A frequency-shift-keyed receiver is also connected to one of the terminals of the field meter for transmitting and converting a frequency shift keyed signal to a digital signal which is, subsequently, applied to the multiplexer.

Holley, L. D.↗

Observations of plasma waves in the solar wind interaction region of Comet Giacobini-Zinner at high time resolution

High-time-resolution spectra of plasma wave emissions detected in the interaction region of Comet Giacobini-Zinner with the solar wind reveal a wave phenomenology much more complicated than first reported. Spectra often exhibit three or more independent peaks, which become more prominent the deeper into the interaction region the spacecraft traversed. The main peaks correspond to whistler emissions below the electron cyclotron frequency, a midfrequency peak near the maximum Doppler shift frequency for waves with k lambda(D) = 1, a high-frequency peak above the Doppler shift maximum frequency, and electron plasma oscillations at the plasma frequency. Similar multipeaked spectra are also observed downstream from weak shocks at Earth, which suggests that the plasma wave generation mechanisms responsible need not require particle populations created by photoionization.

Moses, S. L.↗

Probing hysteretic elasticity in weakly nonlinear materials

Our work is aimed at assessing the elastic and dissipative hysteretic nonlinear parameters' repeatability (precision) using several classes of materials with weak, intermediate and high nonlinear properties. In this contribution, we describe an optimized Nonlinear Resonant Ultrasound Spectroscopy (NRUS) measuring and data processing protocol applied to small samples. The protocol is used to eliminate the effects of environmental condition changes that take place during an experiment, and that may mask the intrinsic elastic nonlinearity. As an example, in our experiments, we identified external temperature fluctuation as a primary source of material resonance frequency and elastic modulus variation. A variation of 0.1 C produced a frequency variation of 0.01 %, which is similar to the expected nonlinear frequency shift for weakly nonlinear materials. In order to eliminate environmental effects, the variation in f{sub 0} (the elastically linear resonance frequency proportional to modulus) is fit with the appropriate function, and that function is used to correct the NRUS calculation of nonlinear parameters. With our correction procedure, we measured relative resonant frequency shifts of 10{sup -5} , which are below 10{sup -4}, often considered the limit to NRUS sensitivity under common experimental conditions. Our results show that the procedure is an alternative to the stringent control of temperature often applied. Applying the approach, we report nonlinear parameters for several materials, some with very small nonclassical nonlinearity. The approach has broad application to NRUS and other Nonlinear Elastic Wave Spectroscopy approaches.

58 GEOSCIENCES↗

Orientational atom interferometers sensitive to gravitational waves

We present an atom interferometer that differs from common atom interferometers as it is not based on the spatial splitting of electronic wave functions, but on orienting atoms in space. As an example we present how an orientational atom interferometer based on highly charged hydrogen-like atoms is affected by gravitational waves. We show that a monochromatic gravitational wave will cause a frequency shift that scales with the binding energy of the system rather than with its physical dimension. For a gravitational wave amplitude of h=10{sup -23} the frequency shift is of the order of 110 {mu}Hz for an atom interferometer based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current atom interferometers in 1 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic dispersion of Langmuir waves. I. The Langmuir decay instability

We derive a fully kinetic, three-dimensional dispersion relation for Langmuir waves with a focus on the Langmuir decay instability (LDI). The kinetic dispersion is compared to the standard fluid dispersion found with an equation of state (EOS) closure. The EOS closure fails to capture the intricacies of the nonlinear pressure when high frequency electron plasma waves (EPWs) couple to low frequency ion acoustic waves (IAWs). In particular, we find discrepancies in the k{lambda}{sub d} scaling of the LDI growth rate, where k is the wavenumber of the incident EPW and {lambda}{sub d} is the Debye length. As a result, the kinetic dispersion relation for LDI results in instability thresholds that can be in excess of twice those predicted by the fluid theory. Both the fluid and kinetic dispersion relations predict a nonlinear frequency shift due to the beating of the pump and scattered EPWs, but again the k{lambda}{sub d} scaling of these frequency shifts differ. In addition, the kinetic dispersion predicts a nonlinear reduction in the IAW damping from the three-wave interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Line Emission from an Accretion Disk Around a Rotating Black Hole: Toward a Measurement of Frame Dragging

Line emission from an accretion disk and a corotating hot spot about a rotating black hole are considered for possible signatures of the frame-dragging effect. We explicitly compare integrated line profiles from a geometrically thin disk about a Schwarzschild and an extreme Kerr black hole, and show that the line profile differences are small if the inner radius of the disk is near or above the Schwarzschild stable-orbit limit of radius 6GM/sq c. However, if the inner disk radius extends below this limit, as is Possible in the extreme Kerr spacetime, then differences can become significant, especially if the disk emissivity is stronger near the inner regions. We demonstrate that the first three moments of a line profile define a three-dimensional space in which the presence of material at small radii becomes quantitatively evident in broad classes of disk models. In the context of the simple, thin disk paradigm, this moment-mapping scheme suggests formally that the iron line detected by the Advanced Satellite,for Cosmology and Astrophysics mission from MCG --6-30-15 (Tanaka et al.) is approximately 3 times more likely to originate from a disk about a rotating black hole than from a Schwarzschild system. A statistically significant detection of black hole rotation in this way may be achieved after only modest improvements in the quality of data. We also consider light curves and frequency shifts in line emission as a function of time for corotating hot spots in extreme Kerr and Schwarzschild geometries. The frequency-shift profile is a valuable measure of orbital parameters and might possibly be used to detect frame dragging even at radii approaching 6GM/sq c if the inclination angle of the orbital plane is large. The light curve from a hot spot shows differences as well, although these too are pronounced only at large inclination angles.

Bromley, Benjamin C.↗

Differential temperature sensor system and method

A differential temperature sensor system and method of determining a temperature shift of an optical resonator and its surroundings are provided. The differential temperature sensor system includes a light generating device capable of generating a beam having a carrier frequency, a modulator capable of modulating the beam with a sideband frequency, and an optical resonator capable of supporting an ordinary mode and an extraordinary mode. The system includes an ordinary mode-lock setup capable of locking the carrier frequency of the beam to the ordinary mode of the optical resonator and an extraordinary mode-lock setup capable of locking the sideband frequency of the beam to the extraordinary mode of the optical resonator by providing a specific radio frequency to the modulator substantially corresponding to a frequency shift between the ordinary mode and the extraordinary mode of the optical resonator resulting from a temperature change of the optical resonator. A processor precisely calculates the differential temperature based upon the frequency shift between the ordinary mode and extraordinary mode of the optical resonator.

Savchenkov, Anatoliy A.↗

Spectral control of nonclassical light pulses using an integrated thin-film lithium niobate modulator

Abstract Manipulating the frequency and bandwidth of nonclassical light is essential for implementing frequency-encoded/multiplexed quantum computation, communication, and networking protocols, and for bridging spectral mismatch among various quantum systems. However, quantum spectral control requires a strong nonlinearity mediated by light, microwave, or acoustics, which is challenging to realize with high efficiency, low noise, and on an integrated chip. Here, we demonstrate both frequency shifting and bandwidth compression of heralded single-photon pulses using an integrated thin-film lithium niobate (TFLN) phase modulator. We achieve record-high electro-optic frequency shearing of telecom single photons over terahertz range (±641 GHz or ±5.2 nm), enabling high visibility quantum interference between frequency-nondegenerate photon pairs. We further operate the modulator as a time lens and demonstrate over eighteen-fold (6.55 nm to 0.35 nm) bandwidth compression of single photons. Our results showcase the viability and promise of on-chip quantum spectral control for scalable photonic quantum information processing.

Optics↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Chronocoulometry for quantitative control of mass removal in micro-structures and sensors

In this work, tungsten wires have been etched in a KOH electrolyte solution. Based on the oxidation state of the electrolytic dissolution reaction's product and time integration of the Faradaic current produced during the reaction, this method is capable of providing a direct measurement of the change in mass of a structure from anodic dissolution. To assess the application of this process for controlled mass removal spanning sub-micrograms to milligrams, two experimental studies and accompanying uncertainty analyses have been undertaken. In the first of these, 5 tungsten wires of length 30 mm were used to remove mass values ranging from 50 to 350 {mu}g. Uncertainty estimates indicate relative combined standard uncertainties of less than 0.3% in the mass changes determined from the measurement of Faradaic current. Comparison of the mass change determined using the electrolytic method, and using a precision ultra-microbalance agreed within this uncertainty. The charge-based method was then applied to modify the dynamic characteristics of a quartz tuning fork oscillator. In these experiments, tungsten fiber attached to one tine of the oscillator was etched in 5 {mu}g increments up to 120 {mu}g of total removed mass. In general, frequency shifts of 2.8 Hz{center_dot}{mu}g{sup -1} were observed, indicating sub-microgram resolution for the characterization of probes based on frequency shift and charge-based mass measurement. Taken together, this study provides the basis for a precision method for determining changes in mass based on electrical measurements from an electrochemical system. The utility of this technique is demonstrated through controlled modification of the dynamic properties of a mechanical oscillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Dependence of the Microwave Dielectric Behavior of Selected Materials

A very sensitive thermal bath is designed to study the effect of temperature on the microwave dielectric response of a sample of nickel oxide and cobalt oxide. The sample under study is placed in a microwave resonant cavity in the TE(sub 011) mode. The perturbations of the electric field are recorded in terms of the frequency shifts and the width changes of the microwave resonant signal as seen on the oscilloscope. The real and imaginary parts of the dielectric constant are calculated by using the values of the frequency shifts and width changes in the Slater's perturbation equations. The dielectric behavior of nickel oxide and cobalt oxide and also their mixture is studied at a microwave frequency of 9.2 GHz as a function of temperature. A computer program is written to analyze the dielectric constant values at different temperatures. The resonant cavity seems to be very sensitive in studying the dielectric relaxation mechanism in these materials. The dielectric behavior is also analyzed using Debye's equations, and relaxation times for these materials are calculated at microwave frequencies.

Dahiya, Jai N.↗

Distributed Brillouin fiber laser sensor

Brillouin fiber sensors can provide distributed strain and temperature measurements over long distances in standard off-the-shelf fiber by measuring the Brillouin frequency shift as a function of position along a fiber. The primary drawback of these systems is their limited sensitivity, which results from the challenge in identifying the Brillouin frequency shift to within a small fraction of the Brillouin linewidth. In this work, we introduce a technique that overcomes this fundamental limitation by establishing a series of lasing modes that experience Brillouin amplification at discrete spatial locations in the test fiber. The linewidth narrowing and high intensity associated with the lasing transition enable precise measurements of this lasing frequency. As an initial demonstration, we present a sensor that simultaneously excites 40 lasing modes in a 400 m fiber, providing a measurement of the strain at 40 discrete locations with a spatial resolution of 4 m. Each sensor exhibits a minimum detectable strain as low as 4 nε/Hz 1/2 with a dynamic range of >5 mε and a bandwidth of ~10 kHz. As the first demonstration that Brillouin lasing can be used for distributed fiber sensing, this work establishes an approach that could enable ultra-high strain sensitivity using off-the-shelf fiber.

47 OTHER INSTRUMENTATION↗

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rogue Mode Shileding in NSLS-II Multipole Vacuum Chambers

Modes with transverse electric field (TE-modes) in the NSLS-II multipole vacuum chamber can be generated at frequencies above 450MHz due to its geometric dimensions. Since the NSLS-II BPM system monitors signals within 10 MHz band at RF frequency of 500 MHz, frequencies of higher-order modes (HOM) can be generated within the transmission band of the band pass filter. In order to avoid systematic errors in the NSLS-II BPM system, we introduced frequency shift of HOMs by using RF metal shielding located in the antechamber slot. We demonstrated numerical modeling and experimental studies of the spurious TE modes in the NSLS-II vacuum chambers with antechamber slot. Calculated frequencies of TE-modes in considered chambers with and without RF shielding were verified experimentally. Flexible BeCu RF shielding inside each chamber at proper location shifts frequencies of H{sub 10p}-modes above {approx}900MHz, except chambers S6 odd and even. These chambers need special attention because of synchrotron radiation from downstream magnets. S6 odd multipole vacuum chamber needs to be measured and the RF shielding length has to be optimized. RF shielding looks adequate for baseline design. Fifty percent of open space provides adequate pumping speed.

25mm434mhz↗