Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Sailboard Fin Design

In high performance boardsailing, demands on the vertical fin or "skeg" often produce "spinout" - when the skeg loses horizontal lift creating a force imbalance and causing the tail of the board to slide sideways. Richard Caldwell, RACE Technology, Inc. used NASA airfoil technology to solve this problem and formed a business based on his solution. After determining that the spinout resulted from air ventilating down the low pressure side of the underwater fin, he adapted the airfoil technology to the design of a short board skeg, which would overcome the problem and lower the drag, resulting in improved performance. He patented his RACE 145 foil section, formed his company and later returned to Langley for additional technical assistance. The company's newest product is a rigid sail that also incorporates NASA technology and has excellent performance. This company no longer exists - product is no longer in production.

Source record↗

Measured Base Pressures on Several Twin Rocket-Nozzle Configurations at Mach Numbers of 0.6 to 1.4 with Effects Due to Nozzle Canting and Stabilizing Fins

An experimental investigation has been conducted at Mach numbers of 0.6 to 1.4 to determine the base pressures on several cylindrical afterbody configurations having two propulsive nozzles and to determine the effect on base pressure of stabilizing fins and the canting outward of the propulsive nozzles. Nozzle design Mach numbers of 2.0 and 3.43 were employed in this investigation and cold air at total pressures up to 120 times the free-stream static pressure was used to simulate nozzle flow. The results show that canting the nozzles outward 11 degrees was effective in increasing base pressures at supersonic speeds and that stabilizing fins caused a decrease in base pressure. The magnitudes of base pressure coefficients obtained in this investigation were consistent with those obtained on similar configurations in previous jet-effect investigations.

Cubbage, James M.↗

Flight Investigations at High-Subsonic, Transonic, and Supersonic Speeds to Determine Zero-Lift Drag of Fin-Stabilized Bodies of Revolution having Fineness Ratios of 12.5, 8.91, and 6.04 and Varying Positions of Maximum Diameter

Rocket-powered models were flown at high-subsonic, transonic, and supersonic speeds to determine the zero-lift drag of fin-stabilized parabolic bodies of revolution differing in fineness ratio and in position of maximum diameter. The present paper presents the results for fineness ratio 12.5, 8.91 and 6.04 bodies having maximum diameters located at stations of 20, 40, 60, and 80 percent of body length. All configurations had cut-off sterns and all had equal base, frontal, and exposed fin areas. For most of the supersonic-speed range models having their maximum diameters at the 60-percent station gave the lowest values of drag coefficient. At supersonic speeds, increasing the fineness ratio generally reduced the drag coefficient for a given position of maximum diameter.

Hart, Roger G.↗

Impact of Cubic Pin Finned Surface Structure Geometry upon Spray Cooling Heat Transfer

Experiments were conducted to study the effects of enhanced surface structures on heat flux using spray cooling. The surface enhancements consisted of cubic pin fins machined on the top surface of copper heater blocks. The structure height, pitch, and width were parametrically vaned. Each copper block had a projected cross-sectional area of 2.0 sq cm. Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2 x 2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data were obtained under nominally degassed (chamber pressure of 41.4 kPa) and gassy conditions (chamber with N2 gas at 100.7 kPa) with a bulk fluid temperature of 20.5 C. Results for both the degassed and gassy cases show that structure width and separation distance have a dominant effect upon the heat transfer for the size ranges used. Cubic pin fin height had little impact upon heat flux. The maximum critical heat flux (CHF) attained for any of the surfaces was 121 W/sq cm, giving an enhancement of 51% relative to the flat surface case under nominally degassed conditions. The gassy case had a maximum CHF of 149 W/sq cm, giving an enhancement of 38% relative to the flat surface case.

Silk, Eric A.↗

Fully-Implicit Navier-Stokes (FIN-S)

FIN-S is a SUPG finite element code for flow problems under active development at NASA Lyndon B. Johnson Space Center and within PECOS: a) The code is built on top of the libMesh parallel, adaptive finite element library. b) The initial implementation of the code targeted supersonic/hypersonic laminar calorically perfect gas flows & conjugate heat transfer. c) Initial extension to thermochemical nonequilibrium about 9 months ago. d) The technologies in FIN-S have been enhanced through a strongly collaborative research effort with Sandia National Labs.

Kirk, Benjamin S.↗

Simulation of Grid-Fin Control Surfaces

Conference poster using previously disclosed techniques and methods (see ARC 16210 & 16212). We present simulations of grid-fin control surfaces to demonstrate geometric complexity and numerical robustness. These results have relevance to high-performance computing and performance of grid-fin-based control systems.

Aftosmis, Michael J.↗

Analytic Couple Modeling Introducing Device Design Factor, Fin Factor, Thermal Diffusivity Factor, and Inductance Factor

A set of convenient thermoelectric device solutions have been derived in order to capture a number of factors which are previously only resolved with numerical techniques. The concise conversion efficiency equations derived from governing equations provide intuitive and straight-forward design guidelines. These guidelines allow for better device design without requiring detailed numerical modeling. The analytical modeling accounts for factors such as i) variable temperature boundary conditions, ii) lateral heat transfer, iii) temperature variable material properties, and iv) transient operation. New dimensionless parameters, similar to the figure of merit, are introduced including the device design factor, fin factor, thermal diffusivity factor, and inductance factor. These new device factors allow for the straight-forward description of phenomenon generally only captured with numerical work otherwise. As an example a device design factor of 0.38, which accounts for thermal resistance of the hot and cold shoes, can be used to calculate a conversion efficiency of 2.28 while the ideal conversion efficiency based on figure of merit alone would be 6.15. Likewise an ideal couple with efficiency of 6.15 will be reduced to 5.33 when lateral heat is accounted for with a fin factor of 1.0.

Seebeck effect↗

Pin fin compliant heat sink with enhanced flexibility

Methods of using heat sinks include placing a pin fin compliant heat sink on a non-flat surface. The pin fin complaint heat sink has top and bottom plates connected by a plurality of pins arranged vertically between the top and bottom plates. The top and bottom plates are vertically conformed to local deviations of the non-flat surface. The top and bottom plates are laterally conformed to an overall shape of the surface. At least either the top or bottom plate is corrugated.

42 ENGINEERING↗

Measurement of Convective Heat Transfer Coefficients with Supercritical CO2 in Novel Additively Manufactured Helically Patterned Pin Fin Tubes Using the Wilson Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO2 flowing in pin-fin patterned pipes in the Heat Exchange and Experimental Testing (HEET) facility at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures in the HEET rig were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over typical Reynolds number range in sCO2, the measured Nu and friction factors were within 7% of classical correlations for smooth tube flow.The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section. Pin length to diameter aspect ratios were 1.33 and 2, while the pin diameter to tube diameter ratio was 0.188 and 0.125. Tests were performed for ReD varying from 6.9×104 to 2.2×105 and at conditions equivalent to the low pressure outlet (8.69 MPa, 361 K) of the low temperature recuperator (LTR) in an indirect sCO2 power cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients.For the better performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.188), the local heat transfer coefficient increased by 112% relative to the Dittus-Boelter correlation at the LTR low pressure outlet. This corresponded to a 282% increase in the product of the heat transfer coefficient and the surface area. Large pressure drops across the test articles were observed.

Searle, Matthew↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

The Experimental and Numerical Investigation of Internal Heat Transfer for Supercritical Carbon Dioxide Cooling in a Staggered Pin Fin Array and Single-Jet Impingement

Over the past decade, the drive to reduce greenhouse gas emissions and to increase thermal efficiency for turbomachinery has invigorated the application of supercritical carbon dioxide (sCO2) power cycles for energy generation. Compared to the industry standard air cycles, sCO2 applications hold the potential for several advantages, including higher efficiencies, smaller footprints, and zero greenhouse gas emissions. However, like any turbomachinery application, the turbine inlet temperature must increase to increase thermal efficiency. This introduces the need for internal cooling features to avoid material failure as operating conditions rise. Two standard features include pin fin turbulators in the trailing edge and jet impingement in the airfoil's leading edge. Over the past several decades, these features have been the subject of extensive research. However, the move to the sCO2 operating environment creates the need to re-visit these features to quantify the heat transfer capabilities within this supercritical cooling environment. The first objective of this paper is to discuss the development of the experimental demonstration for internal heat transfer testing at 200 bar and 400 Celsius, which sits well within the CO2 supercritical region. Next, the heat transfer for pin fin turbulators and single-jet impingement in the sCO2 environment is compared to existing air data-derived correlations to quantify any deviations from literature correlations. Finally, the experimental process aims to validate internal cooling conjugate heat transfer numerical simulations for sCO2 turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Hydrogen desorption using honeycomb finned heat exchangers integrated in adsorbent storage systems

One of the main technical hurdles associated with adsorbent based hydrogen storage systems is relative to their ability to discharge hydrogen effectively, as dictated by fuel cell requirements. In this study, a new honeycomb finned heat exchanger concept was examined to evaluate its potential as a heat transfer system for hydrogen desorption. A bench scale 0.5 L vessel was equipped with the proposed heat exchanger, filled with MOF-5® adsorbent material. The heating power, required to desorb hydrogen, was provided by a 100 W electric heater placed in the center of the honeycomb structure. Two desorption tests, at room temperature and under cryogenic temperatures, were carried out to evaluate the hydrogen desorption performance of the proposed system under different operating conditions. The bench scale vessel performance was verified from both an experimental and a modeling point of view, demonstrating the ability to desorb about 45% of the adsorbed hydrogen in reduced time and applying low heating power. Further modeling analyses were also carried out showing the potential of the proposed system to reach high hydrogen discharging rates at cryogenic temperature conditions and operating pressures between 100 bar and 5 bar. The proposed adsorption system also demonstrated to be able to discharge all the available hydrogen in less than 500 s operating at cryogenic conditions and with a nominal heating power of 100 W.

25 ENERGY STORAGE↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strongly Heated Turbulent Flow in a Channel with Pin Fins

Large-eddy simulations (LES) were performed to study the turbulent flow in a channel of height H with a staggered array of pin fins with diameter D = H/2 as a function of heating loads that are relevant to the cooling of turbine blades and vanes. The following three heating loads were investigated—wall-to-coolant temperatures of Tw/Tc = 1.01, 2.0, and 4.0 - where the Reynolds number at the channel inlet was 10,000 and the back pressure at the channel outlet was 1 bar. For the LES, two different subgrid-scale models—the dynamic kinetic energy model (DKEM) and the wall-adapting local eddy-viscosity model (WALE)—were examined and compared. This study was validated by comparing with data from direct numerical simulation and experimental measurements. The results obtained show high heating loads to create wall jets next to all heated surfaces that significantly alter the structure of the turbulent flow. Results generated on effects of heat loads on the mean and fluctuating components of velocity and temperature, turbulent kinetic energy, the anisotropy of the Reynolds stresses, and velocity-temperature correlations can be used to improve existing RANS models.

42 ENGINEERING↗