Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Explosion Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

High Speed Measurements using Fiber-optic Bragg Grating Sensors

Fiber grating sensors may be used to monitor high-speed events that include catastrophic failure of structures, ultrasonic testing and detonations. This paper provides insights into the utility of fiber grating sensors to measure structural changes under extreme conditions. An emphasis is placed on situations where there is a structural discontinuity. Embedded chirped fiber Bragg grating (CFBG) sensors can track the very high-speed progress of detonation waves (6-9 km/sec) inside energetic materials. This paper discusses diagnostic instrumentation and analysis techniques used to measure these high-speed events.

42 ENGINEERING↗

Nevada Test Site National Emission Standards for Hazardous Air Pollutants Calendar Year 2008

The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office. From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to under-ground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by winds) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the North Las Vegas Facility (NLVF), an NTS support complex in the city of North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2008a) limits the release of radioactivity from a U.S. Department of Energy facility (e.g., the NTS) to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from other man-made sources such as medical treatments. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR, 2008a). At any one location, if multiple radionuclides are detected then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide's concentration by its CL and then adding the fractions together) is less than 1.0. In 2008, the potential dose from radiological emissions to air, from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.9 mrem/yr; well below the 10 mrem/yr dose limit. Air sampling data collected at all six pseudo-critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61 (CFR, 2008a). Concentrations ranged from less than 1 percent to a maximum of 19 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers (12 miles) from the NTS boundary, concentrations at this location would be only a small fraction of that measured on the NTS. Potential dose to the public from NLVF was also very low at 0.00006 mrem/yr; more than 160,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colloquium : Neutrino detectors as tools for nuclear security

For over 40 years, physicists have discussed possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This Colloquium presents a broad overview of several potential neutrino applications, including the near-field monitoring of known reactors, far-field monitoring of known or discovery of undeclared reactors, detection of reactor waste streams, and detection of nuclear explosions. Recent detector advances have made near-field monitoring feasible, whereas farther-field reactor detection and waste stream detection monitoring may be possible in some cases with further research and development. Very long-range reactor monitoring and nuclear explosion detection do not seem feasible for the foreseeable future due to considerable physical and/or practical constraints.

42 ENGINEERING↗

Application of machine learning to estimate fireball characteristics and their uncertainty from infrared spectral data

Experiments or events involving high explosives (HE) can be monitored remotely by infrared (IR) sensors to gather information about the configuration or materials involved in the device. Researchers at the Air Force Institute of Technology (AFIT) developed a phenomenological model for HE fireball spectra in the IR range that allows for parameters to be extracted from Fourier transform infrared (FTIR) data. This model includes parameters tied to physical characteristics of the fireball: temperature, size, soot, and gas concentrations. Previous works have sought to recover these parameters by the fitting of either whole spectra or select wavenumber bands to this phenomenological model. Difficulties arise due to the complex relationships between the parameters to be fit. Uncertainty quantification of the estimated fireball parameters is also problematic since HE experiments do not have any ground truth information on the parameters. It is suggested that artificial neural network (ANN) based approaches may be well suited to this problem, because of their ability to capture complex and highly nonlinear relationships. As such, this work seeks to explore the efficacy of deep artificial neural networks (DNNs) for this problem of parameter recovery from spectra and to also investigate the uncertainty of recovering the fireball parameters from FTIR data. Networks are designed using the hyperparameter optimization tool Hyperopt and trained/tested on artificial data generated using the phenomenological model developed by AFIT. The results of applying the network to the artificial data set are compared to a physics-based band approach that uses a selected number of bands based on their physical properties. Information on the uncertainty of estimating parameters from remotely sensed experimental data is obtained by treating the accuracy of the DNN model on artificial data as an upper bound and by examining the impact of emissivity due to soot on parameter estimation error; the results for artificial data are likely to be optimistic as compared to recovering parameters from experimental data.

42 ENGINEERING↗

Novel Gas Composition Sensor for Monitoring Advanced Power Generation Systems

Power generation based on combustion will be an important part of American energy production for the foreseeable future. Optimization of the combustion process to maximize fuel efficiency and minimize harmful emissions will benefit from sensors capable of withstanding the harsh high pressure and high temperature environment typically found in the chamber. These devices must be versatile and easy to use with low probe cost in order to gain widespread acceptance and use. Physical Sciences Inc. and the research group of Prof. Scott Sanders at the University of Wisconsin have designed and demonstrated a novel sensor system for monitoring the concentration of multiple gas species in power generation systems. The system combines a novel laser from the optical telecommunications industry with a high-temperature measurement probe, sensitive detection electronics, and data processing algorithms. The Phase I program resulted in a successful demonstration of broadband spectroscopy combined with sensitive detection and chemometric algorithms to detect multiple gas species at high temperatures and pressures. A novel optical probe based on a sapphire fiber architecture that is compatible with the conditions expected in coal gasification systems was also designed. The initial target application for the proposed sensor is the monitoring of full scale, advanced power generation systems including coal gasifiers and gas turbines. The technology developed in this work may also be applied to many additional industrial processes, including continuous emission monitoring, pharmaceutical manufacturing and explosives detection. The ability to identify multiple species and measure their concentrations in a gas mixture will allow manufacturers to increase yields and reduce costs.

20 FOSSIL-FUELED POWER PLANTS↗

Tracer Gas Model Development and Verification in PFLOTRAN

Tracer gases, whether they are chemical or isotopic in nature, are useful tools in examining the flow and transport of gaseous or volatile species in the underground. One application is using detection of short-lived argon and xenon radionuclides to monitor for underground nuclear explosions. However, even chemically inert species, such as the noble gases, have bene observed to exhibit non-conservative behavior when flowing through porous media containing certain materials, such as zeolites, due to gas adsorption processes. This report details the model developed, implemented, and tested in the open source and massively parallel subsurface flow and transport simulator PFLOTRAN for future use in modeling the transport of adsorbing tracer gases.

07 ISOTOPE AND RADIATION SOURCES↗

Fiber-optic sensing in cryogenic environments

Passive optical sensors using fiber-optic signal transmission to a remote monitoring station are explored as an alternative to electrical sensors used to monitor the status of explosive propellants. The designs of passive optical sensors measuring liquid level, pressure, and temperature in cryogenic propellant tanks are discussed. Test results for an experimental system incorporating these sensors and operating in liquid nitrogen demonstrate the feasibility of passive sensor techniques and indicate that they can serve as non-hazardous replacements for more conventional measuring equipment in explosive environments.

Sharma, M.↗

Proton-transfer-reaction/ion-mobility-spectrometer and method of using the same

A high-pressure hollow cathode ionizer is combined with an ion-mobility-spectrometer (IMS) for the detection of trace amounts of organic compounds in gas. The ionizer uses H.sub.3 0.sup.+, ions which do not react with air to ionize the organic compounds and the organic compounds are soft ionized. The ionized organic compounds are detected in the IMS at levels of parts per billion and identified using calibrated reference tables. Applications include but are not limited to the fields of: (1) medicine as a breath analyzer for detection of lung cancer, diabetes, liver cirrhosis, (2) law enforcement in drug interdiction and explosives detection, (3) food monitoring and control, (4) environmental monitoring and (5) space applications.

Kanik, Isik↗

LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RADIATION DETECTION CHALLENGES

Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM

Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Digital Data Acquisition Graphical User Interface

Traditional radioxenon measurements have been done by ground based fixed systems, however in recent years there has been an increased need for systems capable of quick deployment or even complete mobility. Using the Pixie-4 data acquisition (DAQ) system can help reduce the electronics footprint of both current systems, like the radioxenon Radionuclide Laboratory 16 (RL-16) and the Swedish Automatic Unit for Noble Gas Acquisition (SAUNA), as well as future systems. Pacific Northwest National Laboratory (PNNL) has developed a Linux based Nyx graphical user interface (GUI) for Pixie-4 cards. The Nyx software can be installed on various Linux platforms and is written in C++. This software offers a rich user interface for configuring and operating the Pixie4 card and PNNL designed high voltage (HV) cards. Nyx allows one to quickly get a nuclear detector operational by maintaining the core diagnostic features built into the Pixie-4 cards. First, Nyx maintains the multitude of adjustable parameters accessible in the Pixie-4 cards, which allows one to customize settings to take full advantage of a particular detector. Nyx also maintains an oscilloscope feature which is extremely useful to optimize settings and to verify proper detector behavior and is often the first feature used in Nyx during detector setup. Finally, Nyx allows the user to collect data in several formats including full pulse shapes to basic histograms. Overall, it is the corner stone for the transition of beta-gamma systems to a state-of-the-art digitizing DAQ.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Progress in Advanced Spectral Analysis of Radioxenon

Improvements to a Java based software package developed at Pacific Northwest National Laboratory (PNNL) for display and analysis of radioxenon spectra acquired by the International Monitoring System (IMS) are described here. The current version of the Radioxenon JavaViewer implements the region of interest (ROI) method for analysis of beta-gamma coincidence data. Upgrades to the Radioxenon JavaViewer will include routines to analyze high-purity germanium detector (HPGe) data, Standard Spectrum Method to analyze beta-gamma coincidence data and calibration routines to characterize beta-gamma coincidence detectors. These upgrades are currently under development; the status and initial results will be presented. Implementation of these routines into the JavaViewer and subsequent release is planned for FY 2011-2012.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

False alarms and the IMS infrasound network: Understanding the factors influencing the creation of false events

The International Monitoring System (IMS) infrasound network has been designed to acquire the necessary data to detect and locate explosions in the atmosphere with a yield equivalent to 1 kiloton of TNT anywhere on Earth. A major associated challenge is the task of automatically processing data from all IMS infrasound stations to identify possible nuclear tests for subsequent review by analysts. This paper is the first attempt to quantify the false alarm rate (FAR) of the IMS network, and in particular to assess how the FAR is affected by the numbers and distributions of detections at each infrasound station. To ensure that the results are sufficiently general, and not dependent entirely on one detection algorithm, the assessment is based on two detection algorithms that can be thought of as end members in their approach to the trade-off between missed detections and false alarms. The results show that the FAR for events formed at only two arrays is extremely high (ranging from 10’s to 100’s of false events per day across the IMS network, depending on the detector tuning). It is further shown that the FAR for events formed at three or more IMS arrays is driven by ocean-generated waves (microbaroms), despite efforts within both detection algorithms for avoiding these signals, indicating that further research into this issue is merited. Overall, the results highlight the challenge of processing data from a globally sparse network of stations to detect and form events. On the basis of these results, it is shown that further work on understanding signal and noise characteristics is needed before attempting to automatically form events detected at only two arrays on the global network. In particular, more work is required to reduce false alarms caused by the detection of microbarom signals.

47 OTHER INSTRUMENTATION↗

Impacts of future nuclear power generation on the international monitoring system

Many countries are considering nuclear power as a means of reducing greenhouse gas emissions, and the IAEA (IAEA, 2022) has forecasted nuclear power growth rates up to 224% of the 2021 level by 2050. Nuclear power plants release trace quantities of radioxenon, an inert gas that is also monitored under international agreements as a signature of nuclear weapons tests. To better understand how nuclear energy growth (and resulting Xe emissions) could affect this global nonproliferation architecture, we modeled daily releases of radioxenon isotopes used for nuclear explosion detection in the International Monitoring System (IMS) that is part of the Comprehensive Nuclear Test-Ban Treaty: 131m Xe, 133 Xe, 133m Xe, and 135 Xe to examine the change in the number of radioxenon detections as compared to the 2021 detection levels. If a 40-station IMS network is used, the detections of 133 Xe in 2050 would range from 82% for the low-power scenario to 195% for the high-power scenario, compared to the detections in 2021. If an 80-station IMS network is used, the detections of 133 Xe in 2050 would range from 83% of the 2021 detection rate for the low-power scenario to 209% for the high-power scenario. Essentially no detections of 131m Xe and 133m Xe are expected. The high growth scenario could lead to a six-fold increase in 135 Xe detections, but the total number of detections is still small (on the order of 1 detection per day in the entire network).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗