Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ethernet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

266 records · Page 15

SpaceVPX Interoperability Assessment

The existing VMEbus (VersaModular Eurocard bus) International Trade Association (VITA)-78 industry standard, also known as SpaceVPX, is an avionics board- and chassis-level standard derived from the OpenVPX standard as defined in VITA-65. While VITA-65 defines backplane and board-level profiles from COTS vendors to ensure interoperability of products used in developing systems and subsystems, the VITA-78 standard defines SpaceVPX to incorporate fault tolerance features that are required by many spaceflight systems. However, VITA-78 allows so much flexibility that interoperability between modules cannot be assured. This assessment provides guidelines on the use of, and extensions to, the VITA-78 standard to enable avionics interoperability for future NASA missions. The assessment team was comprised of subject matter experts (SMEs) from Goddard Space Flight Center (GSFC), the Jet Propulsion Laboratory (JPL), Johnson Space Center (JSC), and Langley Research Center (LaRC). The team included valuable external consulting support from a SME who was a key participant in the development of the VITA-78 standard. The team had extensive collaboration with the NASA Space Technology Mission Directorate (STMD) High Performance Spaceflight Computing (HPSC) project, specifically in the development of SpaceVPX interconnect findings, observations, and NESC recommendations. To provide an understanding of the breadth of implementations that SpaceVPX must accommodate, multiple NASA use cases were analyzed to assess the requirements for SpaceVPX implementations across a wide range of NASA missions (Appendix C). Applications included crewed missions, science missions, and orbital and surface robotic systems. Product surveys were conducted to assess the level of industry support for SpaceVPX, applications, and the variations in their implementations (Appendix D). In-depth analysis was conducted in the areas of: (a) power management and distribution, (b) form factors and daughtercards, (c) interconnect, and (d) fault tolerance. Leveraging the use cases, product surveys, and SMEs from multiple NASA Centers, these areas were analyzed to determine the range of implementations permitted by the VITA-78 standard and potential interoperability issues. Applicable findings and NESC recommendations were provided for each area. During this assessment, there were multiple opportunities to engage with other agencies to learn about their interest in SpaceVPX, their strategies for implementing SpaceVPX-based systems, and their internal development efforts. These engagements also generated findings and NESC recommendations. Based on this assessment analysis, NESC recommendations were made regarding the feature set and module profiles to support NASA SpaceVPX implementations. This feature set includes restrictions on features in VITA-78, and extensions to the standard. Key recommendations in this area include the use of 10 Gigabit Ethernet and Peripheral Component Interconnect Express (PCIe) as high bandwidth interconnect on the backplane, the retention of SpaceWire interconnect for control functions, and support for 3U (unit) and 6U, form factors for NASA systems. Restrictions were proposed on the usage of user-defined signals to promote interoperability, and specific power managements and distribution schemes for 3U systems. Beyond the technical implementation of SpaceVPX, recommendations were made on areas that warrant further investigation. Primary among these is the recommendation for NASA to collaborate with other space-going agencies and industry to incorporate recommendations into a future ‘dot spec’ of VITA-78. This would ensure wide adoption and availability of the modules that comply with the specification. The assessment includes appendices with candidate module profiles that can be considered as a starting point for this activity, and example systems based on the recommendations. Follow-on studies are recommended for architectures beyond SpaceVPX to address potential enhancements including condensed set of interconnect, software required to implement protocol layers on the interconnect (and other features), alternative power architectures, and system-level testability.

SpaceVPX↗

Laser Communications Relay Demonstration: Experiments With Delay Tolerant Networking

The Laser Communications Relay Demonstration (LCRD) is a NASA mission that is presently providing a link between two optical ground stations on Earth and geosynchronous orbit; this capability will be extended to include a laser terminal on the International Space Station (ISS). From a practical perspective, LCRD provides a 1Gbps Ethernet link with an anticipated round-trip time of 4 seconds. Delay Tolerant Networking (DTN) is being used to transcend LCRDs capabilities from a point-to-point link to true network connectivity. Indeed, integrating the LCRD link into any network, such as one aboard the ISS, adds new hops and paths. In this paper, we detail DTN experiments conducted using LCRD to demonstrate how DTN and optical capabilities complement each other to enable the next generation of space communication modalities. We conclude with considerations on using LCRD to connect the ISS to the optical ground stations.

Alan Hylton↗

Separation Assurance in Urban Air Mobility Systems Using Shared Scheduling Protocols

Ensuring safe separation between aircraft is a critical challenge in air traffic management, particularly in urban air mobility (UAM) environments where high traffic density and low altitudes require precise control. In these environments, conflicts often arise at the intersections of flight corridors, posing significant risks. We propose a tactical separation approach leveraging shared scheduling protocols, originally designed for Ethernet networks and operating systems, to coordinate access to these intersections. Using a decentralized Markov decision process framework, the proposed approach enables aircraft to autonomously adjust their speed and timing as they navigate these critical areas, maintaining safe separation without a central controller. We evaluate the effectiveness of this approach in simulated UAM scenarios, demonstrating its ability to reduce separation violations to zero while acknowledging trade-offs in flight times as traffic density increases. Additionally, we explore the impact of non-compliant aircraft, showing that while shared scheduling protocols can no longer guarantee safe separation, they still provide significant improvements over systems without scheduling protocols.

Separation Assurance↗

Separation Assurance in Urban Air Mobility Systems Using Shared Scheduling Protocols

Ensuring safe separation between aircraft is a critical challenge in air traffic management, particularly in urban air mobility (UAM) environments where high traffic density and low altitudes require precise control. In these environments, conflicts often arise at the intersections of flight corridors, posing significant risks. We propose a tactical separation approach leveraging shared scheduling protocols, originally designed for Ethernet networks and operating systems, to coordinate access to these intersections. Using a decentralized Markov decision process framework, the proposed approach enables aircraft to autonomously adjust their speed and timing as they navigate these critical areas, maintaining safe separation without a central controller. We evaluate the effectiveness of this approach in simulated UAM scenarios, demonstrating its ability to reduce separation violations to zero while acknowledging trade-offs in flight times as traffic density increases. Additionally, we explore the impact of non-compliant aircraft, showing that while shared scheduling protocols can no longer guarantee safe separation, they still provide significant improvements over systems without scheduling protocols.

system safety↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronous High-frequency Distributed Readout For Edge Processing At The Fermilab Main Injector And Recycler

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more systematic study of the machine and improved displays of routine operation. However, current projects are demanding more data and at a faster rate from this aging hardware. One such project, Real-time Edge AI for Distributed Systems (READS), requires the high-frequency, low-latency collection of synchronized BLM readings from around the approximately two-mile accelerator complex. Significant work has been done to develop new hardware to monitor the VME backplane and broadcast BLM measurements over Ethernet, while not disrupting the existing operations critical functions of the BLM system. This paper will detail the design, implementation, and testing of this parallel data pathway.

43 PARTICLE ACCELERATORS↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Field Programmable Gate Array Data Capture for Control Systems

Some Industrial Control Systems (ICS) networks are based on protocols such as Serial and Industrial Ethernet. These protocols currently have no existing cybersecurity monitoring tools, leaving a large gap in the cyber defense of critical infrastructure. In order to analyze such ICS traffic, it is first necessary to implement methods of capturing the ICS data. Whereas traditional methods of analyzing data would use microprocessors, the nature of high-speed analog data can be difficult to implement on such a versatile processor, as they are rather inefficient for doing a single task. Whereas Field Programmable Gate Arrays (FPGAs) provide an adequate tool in analyzing high speed data, as despite the lack of program versatility, Programmable Logic can implement a solution with minimal clock cycles, allowing time for each new packet of data to be captured before a new data sample is taken.

42 ENGINEERING↗

Approaches for Autonomous Peer to Peer Communication: For Resilient Community Microgrids

The final phase of the Islandable Communications task of the SECURE project consisted of integrating the islandable communications network into a microgrid simulation at NREL. Initially integration was planned for a microgrid implemented as a mix of simulation and physical hardware. As the project evolved, the microgrid became fully simulated. The simulation environment was structured to break out the communication paths that would pass over a communication network in a field demonstration. The Islandable Communication network was integrated into the simulation environment, allowing both a commercial cellular carrier and a Private LTE network to be evaluated. The microgrid simulation showed differences in performance and behavior when operating over the wireless networks (compared to operating over wired Ethernet in the lab). These differences point to further research opportunities to better understand how microgrid communication carried over real-world or impaired networks affects the microgrid system behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercialization of the Transportation-Security, Tracking, and Reporting System (T-STAR)

The Transportation-Security, Tracking, and Reporting System (T-STAR) was developed by the National Nuclear Security Administration, NA-21, Office of Radiological Security (ORS) to provide a transportation security system for detection and tracking during transport of Category 1 and Category 2 radiological material. Few off-the-shelf systems for conveyance tracking offer detection of a cargo compartment breach or a removal of the cargo. Systems that do offer this capability often require permanent installation through modifying of the conveyance itself. This is not sustainable in many countries where ORS is building use, storage, and transport security capacity. The development of T-STAR has moved from fielding robust prototypes deployed in countries ranging from North America, Latin America and Central Asia to a commercially produced product that can now be deployed to provide enhanced security during transit. Each prototype deployment resulted in important lessons learned, which informed the requirements for the final commercial product. T-STAR uses both cellular and Iridium satellite modems to provide redundant communications to provide the configuration, status, and alerts to a server monitoring the shipment, which is accessible using a multilanguage browser-based user interface. A wireless security system employing using Z-wave sensors for intrusion detection located in the conveyance provide low cost but effective solution for a wide range of conveyance types. Additional capabilities include the ability to monitor a vehicles’ CANBUS (Controller Area Network) system, an ethernet port for high throughput sensor information such as video cameras, and the ability to power and use advanced external sensor payloads. These features make the T-STAR a capable and expandable security gateway that can be deployed on a variety of conveyances from box trucks to open trailers. The ability to provide tracking, monitoring, and detection provide a key component in overall best practices designed to protect shipments of radioactive material.

Schultze, Michael [ORNL] (ORCID:0000000283205671)↗

Design and Testing of the Address in Real-Time Data Driver Card for the Micromegas Detector of the ATLAS New Small Wheel Upgrade

The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data in the Micro-Mesh Gaseous Structure (Micromegas) detector of the ATLAS New Small Wheel (NSW) upgrade. The Address in Real Time (ART) signals are generated by the front-end ASIC, named VMM chip, to indicate the address of the first above-threshold event. A custom ASIC (ART ASIC) is designed to receive the ART signals from the VMM chip and implement the hit-selection. The processed data from the ART ASIC will be transmitted out of the NSW through the GBTx serializer, the unidirectional Versatile Twin Transmitter (VTTx) and fiber optical links. The ART signal is critical for the ATLAS experiment trigger selection thus the performance and stability of the ADDC is very important. To ensure extensive testing of the ADDC, an FPGA Mezzanine Card (FMC) based testing platform and a special designed firmware/software are developed. We find that this test platform works with the commercial Xilinx VC707 FPGA development kit, independent of the other electronics of the NSW it can test all the functions of the ADDC and its long-term stability. This paper will introduce the design, testing procedure and results of the ADDC and the FMC testing platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗