Advancing Artificial Intelligence with Liquid Argon Neutrino Experiments (Technical Report)

The grant allowed two main contributions: 1) The development of a first successful demonstration of the employment of Optimal Transport in liquid argon time projection chamber neutrino detectors. Optimal Transport, used in other contexts and specifically with LHC calorimetric data, was adapted to address a key particle identification challenge in LArTPCs: the separation of pi0 backgrounds from single-electrons produced in charged-current electron neutrino interactions. The work, leveraging ML methods such as k-nearest-neighbor (kNN) and support-vector-machine (SVM), showed an increase in background rejection of a factor of two or more. Work is now ongoing to incorporate this development in physics analyses for LArTPC experiments and more broadly expand the use of OT in LArTPC detectors including DUNE. This work was done in collaboration with the phenomenology group led by Nathaniel Craig at UCSB. 2) The deployment of NuGraph2, a graph neural network developed for LArTPC reconstruction, in the MicroBooNE experiment. NuGraph2 uses novel graph-neural-network methods on the rather simple LArTPC inputs of reconstructed hits, greatly simplifying the workflow compared to the use of waveform or signal-deconvolved wire ROIs. The network performed particle classification and was shown to address many challenging problems in LArTPC imaging including track-shower separation and the identification of protons and charged pions from primary muons. Our group collaborated with Giuseppe Cerati (FNAL scientist) who is one of the core developers of NuGraph2 to integrate this tool in MicroBooNE’s analysis framework. This consisted in tow key contributions: a) Studying performance on real data, which came with several months of iterations because the MC-trained version of the network was found to show significant bias that our group investigated and addressed. b) Integrating the output hit labeling of NuGraph2 into the existing particle tracking and shower reconstruction code. As a result of this work led by our team NuGraph2 is now enabling a suite of new analyses which benefit from enhanced capabilities and thus broader physics reach. The grant supported primarily the salary of UCSB graduate student Chuyue “Michaelia” Fang as well as partial summer salary support for PI Caratelli. Some funds were used for travel by Michaelia to ML related schools and conferences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D track reconstruction of low-energy electrons in the MIGDAL low pressure optical time projection chamber

Here, we demonstrate three-dimensional track reconstruction of electrons in a low pressure (50 Torr) optical TPC consisting of two glass GEMs with an ITO strip readout in CF 4 and CF 4 /Ar mixtures. The reconstructed tracks show a variety of event topologies, including short tracks from photoelectrons induced by 55 Fe 5.9 keV X-rays and long tracks from gamma ray interactions and beta decays. Algorithms for event identification and track ridge detection are discussed as well as multiple methods for integrating information from the camera image and ITO waveforms with the goal of full 3D reconstruction of the track.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel Phase and Power Detector

An electronic signal-processing system determines the phases of input signals arriving in multiple channels, relative to the phase of a reference signal with which the input signals are known to be coherent in both phase and frequency. The system also gives an estimate of the power levels of the input signals. A prototype of the system has four input channels that handle signals at a frequency of 9.5 MHz, but the basic principles of design and operation are extensible to other signal frequencies and greater numbers of channels. The prototype system consists mostly of three parts: An analog-to-digital-converter (ADC) board, which coherently digitizes the input signals in synchronism with the reference signal and performs some simple processing; A digital signal processor (DSP) in the form of a field-programmable gate array (FPGA) board, which performs most of the phase- and power-measurement computations on the digital samples generated by the ADC board; and A carrier board, which allows a personal computer to retrieve the phase and power data. The DSP contains four independent phase-only tracking loops, each of which tracks the phase of one of the preprocessed input signals relative to that of the reference signal (see figure). The phase values computed by these loops are averaged over intervals, the length of which is chosen to obtain output from the DSP at a desired rate. In addition, a simple sum of squares is computed for each channel as an estimate of the power of the signal in that channel. The relative phases and the power level estimates computed by the DSP could be used for diverse purposes in different settings. For example, if the input signals come from different elements of a phased-array antenna, the phases could be used as indications of the direction of arrival of a received signal and/or as feedback for electronic or mechanical beam steering. The power levels could be used as feedback for automatic gain control in preprocessing of incoming signals. For another example, the system could be used to measure the phases and power levels of outputs of multiple power amplifiers to enable adjustment of the amplifiers for optimal power combining.

Li, Samuel↗

Cosmic ray isotope abundances from chromium to nickel

IRIS, a telescope consisting of a large-area precision Cerenkov detector, scintillators, spark chambers, and a passive stack of Lexan polycarbonate track detectors, was exposed to the primary cosmic radiation for 6.6 sq m sr hr in a balloon flight in 1976. This measurement has yielded the isotopic composition of the iron-group elements Cr, Mn, Fe, and Ni with an average mass resolution of 0.65 amu for the energies 320-500 MeV per amu at the detector. This experiment places the most severe constraints to date on deviation from solar-system composition of the source of the cosmic radiation. Upper limits of 10 percent are placed on the ratios Fe-54/Fe-56 and Fe-58/Fe-56, which are inconsistent with large departures from solar system source composition reported by other workers. The isotopic measurements of Fe and Ni preclude the possibility that these cosmic rays were produced in a single e-process zone. The mean mass of Mn is less than 55, indicating the presence of electron-capture species produced by spallation.

Tarle, G.↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Advanced Energetic Pair Telescope (AdEPT}: A Future Medium-Energy Gamma-Ray Balloon (and Explorer?) Mission

Gamma-ray astrophysics probes the highest energy, exotic phenomena in astrophysics. In the medium-energy regime, 0.1-200 MeV, many astrophysical objects exhibit unique and transitory behavior such as the transition from electron dominated to hadron dominated processes, spectral breaks, bursts, and flares. Medium-energy gamma-ray imaging however, continues to be a major challenge particularly because of high background, low effective area, and low source intensities. The sensitivity and angular resolution required to address these challenges requires a leap in technology. The Advance Energetic Pair Telescope (AdEPT) being developed at GSFC is designed to image gamma rays above 5 MeV via pair production with angular resolution of 1-10 deg. In addition AdEPT will, for the first time, provide high polarization sensitivity in this energy range. This performance is achieved by reducing the effective area in favor of enhanced angular resolution through the use of a low-density gaseous conversion medium. AdEPT is based on the Three-Dimensional Track Imager (3-DTI) technology that combines a large volume Negative Ion Time Projection Chamber (NITPC) with 2-D Micro-Well Detector (MWD) readout. I will review the major science topics addressable with medium-energy gamma-rays and discuss the current status of the AdEPT technology, a proposed balloon instrument, and the design of a future satellite mission.

Hunter, Stanley D.↗

The Mu2e straw tracker detector status and prototype results

The Mu2e experiment will search for charge-lepton flavor violating (CLFV) muon to electron conversion. It aims to achieve a four-orders of magnitude improvement in sensitivity over previous experiments, allowing it to probe new physics at mass scales up to 10 4 TeV . A precision momentum measurement is needed to resolve the monoenergetic electron that is the signal of CLFV conversion from muon decay-in-orbit backgrounds. Here, this is achieved in Mu2e using a low-mass cylindrical straw tracker operated in vacuum, consisting of 21,000 thin-wall mylar straws held at tension. The Mu2e tracker is now in production and will be completed during 2025. We will discuss the design and status of the experiment and the tracker detector, and show results from data taken with the first tracker module.

Gaseous detector↗

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

The Micro-Arcsecond Metrology Testbed

The Micro-Arcsecond Metrology (MAM) testbed is a ground-based system of optical and electronic equipment for testing components, systems, and engineering concepts for the Space Interferometer Mission (SIM) and similar future missions, in which optical interferometers will be operated in outer space. In addition, the MAM testbed is of interest in its own right as a highly precise metrological system. The designs of the SIM interferometer and the MAM testbed reflect a requirement to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer with sufficient spatial resolution to generate astrometric data with angular resolution at the microarcsecond level. The internal path is to be measured by use of a small metrological laser beam of 1,319-nm wavelength, whereas the position of the starlight fringe is to be estimated by use of a charge-coupled-device (CCD) image detector sampling a large concentric annular beam. For the SIM to succeed, the optical path length determined from the interferometer fringes must be tracked by the metrological subsystem to within tens of picometers, through all operational motions of an interferometer delay line and siderostats. The purpose of the experiments performed on the MAM testbed is to demonstrate this agreement in a large-scale simulation that includes a substantial portion of the system in the planned configuration for operation in outer space. A major challenge in this endeavor is to align the metrological beam with the starlight beam in order to maintain consistency between the metrological and starlight subsystems at the system level. The MAM testbed includes an optical interferometer with a white light source, all major optical components of a stellar interferometer, and heterodyne metrological sensors. The aforementioned subsystems are installed in a large vacuum chamber in order to suppress atmospheric and thermal disturbances. The MAM is divided into two distinct subsystems: the test article (TA), which is the interferometer proper, and the inverse interferometer pseudo-star (IIPS), which synthesizes the light coming from a distant target star by providing spatially coherent wavefronts out of two mirrors, separated by the MAM baseline, that feed directly into two siderostats that are parts of the TA. The two feed mirrors of the IIPS are articulated (in translation and tilt) in order to simulate stars located at different orientations in space, while still illuminating the TA siderostats. The spectrum of the simulated starlight of the IIPS corresponds to that of a blackbody at a temperature of about 3,100 K.

Goullioud, Renaud↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LGAD-Based Silicon Sensors for 4D Detectors

Low-Gain Avalanche Diodes (LGAD) are a class of silicon sensors developed for the fast detection of Minimum Ionizing Particles (MIPs). The development was motivated by the need of resolving piled-up tracks of charged particles emerging from several vertexes originating from the same bunch-crossing in High-Energy Physics (HEP) collider experiments, which, however, are separated not only in space but also in time by a few tens of picoseconds. Built on thin silicon substrates and featuring an internal moderate gain, they provide fast signals for excellent timing performance, which are therefore useful to distinguish the different tracks. Unfortunately, this comes at the price of poor spatial resolution. To overcome this limitation, other families of LGAD-based silicon sensors which can deliver in the same substrate both excellent timing and spatial information are under development. Such devices are, to name a few, capacitively coupled LGADs (AC-LGAD), deep-junction LGADs (DJ-LGAD) and trench-isolated LGADs (TI-LGADs). These devices can be fabricated by even small-scale research-focused clean rooms for faster development within the scientific community. However, to scale up production, efforts towards integrating these sensor concepts in CMOS substrates, with the obvious advantage of the possibility of integrating part of the read-out electronics in the same substrate, have begun.

spatial resolution↗

Target-Tracking Camera for a Metrology System

An analog electronic camera that is part of a metrology system measures the varying direction to a light-emitting diode that serves as a bright point target. In the original application for which the camera was developed, the metrological system is used to determine the varying relative positions of radiating elements of an airborne synthetic aperture-radar (SAR) antenna as the airplane flexes during flight; precise knowledge of the relative positions as a function of time is needed for processing SAR readings. It has been common metrology system practice to measure the varying direction to a bright target by use of an electronic camera of the charge-coupled-device or active-pixel-sensor type. A major disadvantage of this practice arises from the necessity of reading out and digitizing the outputs from a large number of pixels and processing the resulting digital values in a computer to determine the centroid of a target: Because of the time taken by the readout, digitization, and computation, the update rate is limited to tens of hertz. In contrast, the analog nature of the present camera makes it possible to achieve an update rate of hundreds of hertz, and no computer is needed to determine the centroid. The camera is based on a position-sensitive detector (PSD), which is a rectangular photodiode with output contacts at opposite ends. PSDs are usually used in triangulation for measuring small distances. PSDs are manufactured in both one- and two-dimensional versions. Because it is very difficult to calibrate two-dimensional PSDs accurately, the focal-plane sensors used in this camera are two orthogonally mounted one-dimensional PSDs.

Liebe, Carl↗

NASA Tech Briefs, January 2011

The topics include: 1) Distributed Aerodynamic Sensing and Processing Toolbox; 2) Collaborative Supervised Learning for Sensor Networks; 3) Hazard Detection Software for Lunar Landing; 4) Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme; 5) Network-Capable Application Process and Wireless Intelligent Sensors for ISHM; 6) Interface Supports Multiple Broadcast Transceivers for Flight Applications; 7) FPGA Sequencer for Radar Altimeter Applications; 8) Miniature Sapphire Acoustic Resonator - MSAR; 9) Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents; 10) SAD5 Stereo Correlation Line-Striping in an FPGA; 11) Hybrid Composite Cryogenic Tank Structure; 12) Nanoscale Deformable Optics; 13) Reliability-Based Design Optimization of a Composite Airframe Component; 14) Zinc Oxide Nanowire Interphase for Enhanced Lightweight Polymer Fiber Composites; 15) Plasma Igniter for Reliable Ignition of Combustion in Rocket Engines; 16) Wire Test Grip Fixture; 17) A Sub-Hertz, Low-Frequency Vibration Isolation Platform; 18) Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics; 19) Nanoparticle/Polymer Nanocomposite Bond Coat or Coating; 20) High-Resolution Wind Measurements for Offshore Wind Energy Development; 21) Spring Tire; 22) Marsviewer 2008; 23) Mission Services Evolution Center Message Bus; 24) Major Constituents Analysis for the Vehicle Cabin Atmosphere Monitor; 25) Astronaut Health Participant Summary Application; 26) Adaption of the AMDIS Method to Flight Status on the VCAM Instrument; 27) Natural Language Interface for Safety Certification of Safety-Critical Software; 28) Cryogenic Caging for Science Instrumentation; 29) Wide-Range Neutron Detector for Space Nuclear Applications; 30) In Situ Guided Wave Structural Health Monitoring System; 31) Multiplexed Energy Coupler for Rotating Equipment; 32) Attitude Estimation in Fractionated Spacecraft Cluster Systems; 33) Full Piezoelectric Multilayer-Stacked Hybrid Actuation/Transduction Systems; 34) Active Flow Effectors for Noise and Separation Control; 35) Method and System for Temporal Filtering in Video Compression Systems; 36) Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples; 37) Multiple-Zone Diffractive Optic Element for Laser Ranging Applications; 38) Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver; 39) Two-Photon-Absorption Scheme for Optical Beam Tracking; 40) High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities; 41) Wide-Field Optic for Autonomous Acquisition of Laser Link; 42) Extracting Zero-Gravity Surface Figure of a Mirror; 43) Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects; 44) Visual Object Recognition and Tracking of Tools; 45) Method for Implementing Optical Phase Adjustment; 46) Visual SLAM Using Variance Grid Maps; 47) Rapid Calculation of Spacecraft Trajectories Using Efficient Taylor Series Integration; 48) Efficient Kriging Algorithms; 49) Predicting Spacecraft Trajectories by the WeavEncke Method; 50) An Augmentation of G-Guidance Algorithms; 51) Comparison of Aircraft Icing Growth Assessment Software; 52) Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz; 53) Estimation of Coriolis Force and Torque Acting on Ares-1; 54) Null Lens Assembly for X-Ray Mirror Segments; and 55) High-Precision Pulse Generator.

Source record↗

Novel usage of deep learning and high-performance computing in long-baseline neutrino oscillation experiments

Mención Internacional en el título de doctorDeep-learning methods are playing a crucial role in numerous scientific and industrialapplications. Over the past two decades, these techniques have helped in the collection,reconstruction, and analysis of large data samples in particle physics experiments. Themain topic of this PhD research is the study of deep-learning techniques in long-baselineneutrino oscillation experiments. Neutrinos are mysterious light elementary particles,and their investigation is essential to shed light on some of the remaining open questionsin physics. The work presented here describes an algorithm based on a convolutionalneural network developed to provide highly accurate and efficient selections of electronneutrino and muon neutrino interactions in the Deep Underground Neutrino Experiment(DUNE). With this algorithm, the electron neutrino (antineutrino) selection efficiencypeaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between2-5 GeV. The selection efficiency for muon neutrino (antineutrino) interactions is foundto have a maximum of 96% (97%) and exceeds 90% (95%) efficiency for reconstructedneutrino energies above 2 GeV. When considering all electron neutrino and antineutrinointeractions as signal (both those appearing from oscillations and those intrinsic tothe beam), a selection purity of 90% is achieved. These event selections are criticalto maximise the sensitivity of the experiment to CP-violating effects, key to furtherunderstand the matter-antimatter asymmetry of the Universe.In high-energy physics experiments, deep learning has also been explored for producingfast simulations and physically-motivated manipulations of simulated images. Some ofthose simulations, such as the light production and detection, are very computationallyexpensive and require novel methods to produce the necessary samples while controllingthe varied underlying physics model parameters. To do so, we invented the model-assistedgenerative adversarial network (MAGAN), first validated on simple generic case studiesand then successfully applied to the DUNE photon-detector simulation.Moreover, we also developed graph neural networks for 3D-voxel classification ofambiguities and optical crosstalk for a different particle physics experiment, most preciselyfor the proposed SuperFGD. This novel 3D-granular plastic-scintillator neutrino detectorwill be used to upgrade the near detector of the T2K neutrino oscillation experiment, and our method reports efficiencies and purities of 94-96% per event in the classificationof particle track voxels.Due to the growth and complexity of deep neural networks, researchers have beeninvestigating techniques to train those networks in a more computationally-efficient way.Many efforts have been made by the community to optimise deep-learning models byparallelising or distributing their training computation across multiple devices. In thisthesis, we study an approach based on data locality for those neural networks that cannotbenefit from scaling their computation due to a significant bottleneck in the data I/O.The research also includes a detailed study on the performance of deep neural networkson hardware accelerator boards.Los métodos de aprendizaje profundo son cada vez más utilizados en numerosas aplicacionescientíficas e industriales hoy en día. Durante las dos últimas décadas, estastécnicas se han empleado en la recolección, reconstrucción y análisis de la gran cantidadde datos generados por experimentos de física de partículas. El tema principal de estatesis doctoral es el uso de estos modelos de aprendizaje profundo en experimentos defísica de neutrinos, en concreto en los experimentos de larga distancia DUNE y T2K. Losneutrinos, partículas fundamentales neutras, de las más ligeras del Universo, pueden serclave para explicar algunas de las cuestiones todavía sin resolver en física fundamental.Entre las diferentes contribuciones que esta tesis ha hecho a su estudio, cabe destacar eldesarrollo de un algoritmo basado en una red de neuronas convolucional para seleccionarcon gran eficiencia y precisión las interacciones de neutrinos electrónicos y muónicos enel Deep Underground Neutrino Experiment (DUNE). La eficiencia de selección obtenidapara neutrinos (antineutrinos) electrónicos alcanza un máximo del 90% (94%) y supera el85% (90%) para neutrinos con energías reconstruidas en el rango 2-5 GeV. La selección deneutrinos (antineutrinos) muónicos tiene una eficiencia máxima del 96% (97%) y excedeel 90% (95%) para neutrinos con energías reconstruidas de más de 2 GeV. Considerandocomo señal todas las interacciones de neutrinos y antineutrinos electrónicos (procedentestanto de oscilaciones como intrínsecos en el haz inicial), se logra una pureza en la seleccióndel 90%. Dichas selecciones de eventos son fundamentales para maximizar la sensibilidaddel experimento a los efectos de violació...