Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Science and technology results from the OSS-1 payload on the Space Shuttle

The OSS-1 Payload of nine experiments was carried on the STS-3 Space Shuttle flight in March of 1982. The OSS-1 Payload contained four instruments that evaluated specific aspects of the Orbiter's environment, including the levels of particulate, gaseous and electromagnetic emissions given off by the Orbiter, and the interactions between the Orbiter and the surrounding plasma. In addition to these environmental observations, these instruments performed scientific investigations in astronomy and in space plasma physics, including active experiments in electron beam propagation. Other experiments were in the areas of solar physics, plant growth, micrometeorite studies and the technology of actively controlled heat pipes. We present the initial results from these experiments, with some implications of these results for future operation of space experiments from the Shuttle payload bay. One major result was the unexpected discovery of a faint surface-induced optical glow created near the Shuttle surfaces by impacts of ambient atmospheric atoms and molecules.

short duration↗

Landsat-7 ETM+ On-Orbit Reflective-Band Radiometric Stability and Absolute Calibration

The Landsat-7 spacecraft carries the Enhanced Thematic Mapper Plus (ETM+) instrument. This instrument images the Earth land surface in eight parts of the electromagnetic spectrum, termed spectral bands. These spectral images are used to monitor changes in the land surface, so a consistent relationship, i.e., calibration, between the image data and the Earth surface brightness, is required. The ETM+ has several on- board calibration devices that are used to monitor this calibration. The best on-board calibration source employs a flat white painted reference panel and has indicated changes of between 0.5% to 2% per year in the ETM+ response, depending on the spectral band. However, most of these changes are believed to be caused by changes in the reference panel, as opposed to changes in the instrument's sensitivity. This belief is based partially on on-orbit calibrations using instrumented ground sites and observations of "invariant sites", hyper-arid sites of the Sahara and Arabia. Changes determined from these data sets indicate are 0.1% - 0.6% per year. Tests and comparisons to other sensors also indicate that the uncertainty of the calibration is at the 5% level.

FROM↗

Final Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst↗

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

COMPARISON OF THEORY AND MEASUREMENTS OF A TWO-STAGE LIGHT-GAS GUN

A comparison of techniques for obtaining projectile velocity history on a two-stage launcher and discuss gun code accuracy vis-a-vis pressure gauges and the new photonic Doppler velocimetry (PDV) technique is presented. The PDV technique itself is described in a companion paper. The PDV records were differentiated to compute acceleration and, hence, base pressure. Two acceleration episodes are revealed in the data. Base pressure values were compared with measurements from stationary pressure gauges and with predictions of a standard two-stage gun code. The agreement with the pressure gages was satisfactory. Code predictions did not account for the two acceleration stages. However, for the main acceleration episode, the predicted base pressure is in good agreement with the smoothed pressure computed from the PDV record. Both the gauge records and PDV contain short-time pressure spikes which are apparently real. Therefore, use of computed base pressure for projectile design may lead to failures if the projectile is vulnerable to pressure spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

6.5 kW, Yb:YAG Ceramic Thin Disk Laser

The operation of a 1030 nm, single, thin disk laser which produced 6.5 kW of laser output power with 57 percent slope efficiency is reported. The Yb:YAG ceramic gain element is 200 {mu}m thick, bonded to a 1 mm, undoped, ceramic YAG cap. The gain element is pumped by diodes at 940 nm. The maximum incident pump intensity was 5 kW/cm{sup 2}, which yielded an output intensity of 2.6 kW/cm{sup 2} of multimode laser radiation. Rigrod analysis suggests that the laser operates with inhomogeneous gain saturation. This is attributed to the enhanced, spatial-hole-burning effect when the gain element is adjacent to a mirror. The pump threshold and output intensities were independent of pump spot size, which validates area scaling. Observed thermal lensing contributions include thermal-expansion-induced disk flexure, pump-edge-induced temperature profile and a strong thermal imprint of the cooling nozzle due to the direct jet impingement on the high reflection (HR) coated side. Weak absorption of the 1030 nm intracavity intensity in the undoped cap and/or the anti-reflection (AR) coating led to excess heating that limited the extracted power intensity. These results suggest ceramic Yb:YAG can be scaled to higher powers using optimized thin disk elements and improved disk thermal management techniques.

36 MATERIALS SCIENCE↗

Thicker, more efficient superconducting strip-line detectors for high throughput macromolecules analysis

Fast detectors with large area are required in time-of-flight mass spectrometers for high throughput analysis of biological molecules. We fabricated and characterized subnanosecond 1x1 mm{sup 2} NbN superconducting strip-line detectors. The influence of the strip-line thickness on the temporal characteristics and efficiency of the detector for the impacts of keV accelerated molecules is investigated. We find that the increase of thickness improves both efficiency and response time. In the thicker sample we achieved a rise time of 380 ps, a fall time of 1.38 ns, and a higher count rate. The physics involved in this behavior is investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advances in terahertz solid-state physics and devices

Terahertz (THz) science and technology have attracted tremendous attention owing to their potential applications in areas including high-speed communications, nondestructive evaluation, biological and medical sensing, and national security.1,2 Terahertz waves bridge electronics and photonics, as well as classical and quantum physics, making them equally attractive for fundamental studies of novel physical phenomena. To realize a broad range of real terahertz applications, it is essential to develop compact solid- state devices for terahertz sources, detectors, modulators, and compact systems. These devices often employ quantum materials and heterostructures and can incorporate other features including carrier transfer using atomic layer epitaxy, micro- and electromechanical systems, plasmonic resonators, and metamaterials. To optimize these devices, we have to understand and control ultrafast carrier dynamics in these advanced materials. Furthermore, we have organized a Special Topic in the Journal of Applied Physics to highlight the state-of-the-art in terahertz solid-state devices while also unveiling the properties of these materials on an ultrafast timescale.

47 OTHER INSTRUMENTATION↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

CASSINI UVIS STELLAR OCCULTATION OBSERVATIONS OF SATURN's RINGS

The Cassini spacecraft's Ultraviolet Imaging Spectrograph (UVIS) includes a high-speed photometer (HSP) that has observed more than 100 stellar occultations by Saturn's rings. Here, we document a standardized technique applied to the UVIS-HSP ring occultation datasets delivered to the Planetary Data System as higher level data products. These observations provide measurements of ring structure that approaches the scale of the largest common ring particles ({approx}5 m). The combination of multiple occultations at different viewing geometries enables reconstruction of the three-dimensional structure of the rings. This inversion of the occultation data depends on accurate calibration of the data so that occultations of different stars taken at different times and under different viewing conditions can be combined to retrieve ring structure. We provide examples of the structure of the rings as seen from several occultations at different incidence angles to the rings, illustrating changes in the apparent structure with viewing geometry.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPROVED CONSTRAINTS ON PRIMORDIAL NON-GAUSSIANITY FOR THE WILKINSON MICROWAVE ANISOTROPY PROBE 5-YEAR DATA

We present constraints on the nonlinear coupling parameter f{sub nl} with the Wilkinson Microwave Anisotropy Probe (WMAP) data. We use an updated method based on the spherical Mexican hat wavelet (SMHW) which provides improved constraints on the f{sub nl} parameter. This paper is a continuation of a previous work by Curto et al., where several third-order statistics based on the SMHW were considered. In this paper, we use all the possible third-order statistics computed from the wavelet coefficient maps evaluated at 12 angular scales. The scales are logarithmically distributed from 6.9 arcmin to 500 arcmin. Our analysis indicates that f{sub nl} is constrained to -18 < f{sub nl} < +80 at 95% confidence level (CL) for the combined V+W WMAP map. This value has been corrected by the presence of undetected point sources, which adds a positive contribution of DELTAf{sub nl} = 6 +- 5. Our result excludes at approx99% CL the best-fitting value f{sub nl} = 87 reported by Yadav and Wandelt. We have also constrained f{sub nl} for the Q, V, and W frequency bands separately, finding compatibility with zero at 95% CL for the Q and V bands but not for the W band. We have performed some further tests to understand the cause of this deviation which indicate that systematics associated with the W radiometers could be responsible for this result. Finally, we have performed a Galactic north-south analysis for f{sub nl}. We have not found any asymmetry, i.e., the best-fitting f{sub nl} for the northern pixels is compatible with the best-fitting f{sub nl} for the southern pixels.

79 ASTRONOMY AND ASTROPHYSICS↗

OBSERVATIONS OF THE NEAR-INFRARED SPECTRUM OF THE ZODIACAL LIGHT WITH CIBER

Interplanetary dust (IPD) scatters solar radiation which results in the zodiacal light that dominates the celestial diffuse brightness at optical and near-infrared wavelengths. Both asteroid collisions and cometary ejections produce the IPD, but the relative contribution from these two sources is still unknown. The low resolution spectrometer (LRS) onboard the Cosmic Infrared Background ExpeRiment (CIBER) observed the astrophysical sky spectrum between 0.75 and 2.1 {mu}m over a wide range of ecliptic latitude. The resulting zodiacal light spectrum is redder than the solar spectrum, and shows a broad absorption feature, previously unreported, at approximately 0.9 {mu}m, suggesting the existence of silicates in the IPD material. The spectral shape of the zodiacal light is isotropic at all ecliptic latitudes within the measurement error. The zodiacal light spectrum, including the extended wavelength range to 2.5 {mu}m using Infrared Telescope in Space (IRTS) data, is qualitatively similar to the reflectance of S-type asteroids. This result can be explained by the proximity of S-type asteroidal dust to Earth's orbit, and the relatively high albedo of asteroidal dust compared with cometary dust.

79 ASTRONOMY AND ASTROPHYSICS↗

THE NORTH AMERICAN AND PELICAN NEBULAE. II. MIPS OBSERVATIONS AND ANALYSIS

We present observations of {approx}7 deg{sup 2} of the North American and Pelican Nebulae region at 24, 70, and 160 {mu}m with the Spitzer Space Telescope Multiband Imaging Photometer for Spitzer (MIPS). We incorporate the MIPS observations with earlier Spitzer Infrared Array Camera (IRAC) observations, as well as archival near-infrared (IR) and optical data. We use the MIPS data to identify 1286 young stellar object (YSO) candidates. IRAC data alone can identify 806 more YSO candidates, for a total of 2076 YSO candidates. Prior to the Spitzer observations, there were only {approx}200 YSOs known in this region. Three subregions within the complex are highlighted as clusters: the Gulf of Mexico, the Pelican, and the Pelican's Hat. The Gulf of Mexico cluster is subject to the highest extinction (A{sub V} at least {approx}30) and has the widest range of infrared colors of the three clusters, including the largest excesses and by far the most point-source detections at 70 {mu}m. Just 3% of the cluster members were previously identified; we have redefined this cluster as about 10-100 times larger (in projected area) than was previously realized.

79 ASTRONOMY AND ASTROPHYSICS↗