Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography

Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.

Non-NASA Center↗

New approaches to the Doppler echocardiographic assessment of diastolic function: from research laboratory to clinical practice

Over the past decade, Doppler echocardiography has become a well-established tool for the diagnosis of left ventricular diastolic dysfunction. Unfortunately, in many clinical situations traditional Doppler indices of transmittal and pulmonary venous flow are inconclusive, primarily due to their dependence on left atrial pressure. Recently, new Doppler indices that are much less dependent on preload have been developed, based on intraventricular flow propagation and intrinsic myocardial velocity. These methodologies provide direct assessment of ventricular relaxation and the small intraventricular pressure gradients essential to efficient filling of the ventricle. We review in this article the theoretical and experiment background of these new echo techniques as well as how they can be implemented in routine clinical practice.

NASA Discipline Cardiopulmonary↗

Assessment of diastolic function by tissue Doppler echocardiography: comparison with standard transmitral and pulmonary venous flow

The objective of this study was to determine the utility of Doppler tissue echocardiography in the evaluation of diastolic filling and in discriminating between normal subjects and those with various stages of diastolic dysfunction. We measured myocardial velocities in 51 patients with various stages of diastolic dysfunction and in 27 normal volunteers. The discriminating power of each of the standard Doppler indexes of left ventricular filling, pulmonary venous flow, and myocardial velocities was determined with the use of Spearman rank correlation and analysis of variance F statistics. Early diastolic myocardial velocity (E(m)) was higher in normal subjects (16.0 +/- 3.8 cm/s) than in patients with either delayed relaxation (n = 15, 7.5 +/- 2.2 cm/s), pseudonormal filling (n = 26, 7.6 +/- 2.3 cm/s), or restrictive filling (n = 10, 7.4 +/- 2.4 cm/s, P <.0001). E(m ) was the best single discriminator between control subjects and patients with diastolic dysfunction (P =.7, F = 64.5). Myocardial velocities assessed by Doppler tissue echocardiography are useful in differentiating patients with normal from those with abnormal diastolic function. Myocardial velocity remains reduced even in those stages of diastolic dysfunction characterized by increased preload compensation.

NASA Discipline Regulatory Physiology↗

Spacecraft Doppler Tracking as a Narrow-Band Detector of Gravitational Waves

We discuss spacecraft Doppler tracking for detecting gravitational waves in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we derive a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground.

Spacecraft Doppler↗

Spacecraft Doppler Tracking as a Xylophone Detector of Gravitational Radiation

Spacecraft Doppler tracking is discussed for detecting gravitational waves in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. A new method is derived for removing from combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground. The remaining non-zero gravitational wave signal could be used for detecting gravitational waves.

Doppler tracking gravitational waves signal proces↗

An on-board processor for a spaceborne Doppler precipitation radar : requirements and preliminary design

Use of Doppler velocity measurement in spaceborne precipitation radar is highly desirable, since it can allow more accurate retrieval of atmospheric latent heating, which depends on both cloud and rain microphysical processes and on dynamical processes, namely, vertical updrafts and downdrafts. However, if the rain within the antenna beam is very non-uniform, biases can result with conventional pulse-pair processing, and more sophisticated processing is required. The solution is a time-frequency approach, which uses the full Doppler spectrum at each point in time. Since precipitation radars normally operate continuously and collect large amounts of data, real-time, on-board processing of data is needed to reduce the data rate. The objective of this work is to develop an on-board data processor for spaceborne Doppler precipitation radar, using field-programmable gate array (FPGA) technology. This paper describes the simulations and analysis that have been completed during the first year of the project. This includes both analytical calculations and bit-true simulations that allow the effects of finite word length to be explored. Tradeoffs have also been considered between speed and space within the chosen FPGA part. The results of these analyses have been used to develop a complete set of requirements for the processor. Initial design work has begun, based on these requirements. The design is being implemented in Verilog, and a description of this early design effort is also be given.

on-board processing↗

Spaceborne Doppler Precipitation Radar: System Configurations and Performance Analysis

Knowledge of the global distribution of the vertical velocity of precipitation is important in in the study of energy transportation in the atmosphere, the climate and weather. Such knowledge can only be directly acquired with the use of spaceborne Doppler precipitation radars. Although the high relative speed of the radar with respect to the rainfall particles introduces significant broadening in the Doppler spectrum, recent studies have shown that the average vertical velocity can be measured to acceptable accuracy levels by appropriate selection of radar parameters. Furthermore, methods to correct for specific errors arising from NUBF effects and pointing uncertainties have recently been developed. In this paper we will present the results of the trade studies on the performances of a spaceborne Doppler radar with different system parameters configurations.

spaceborne radar↗

Non-intrusive Shock Measurements Using Laser Doppler Vibrometers

Stud mount accelerometers are widely used by the aerospace industry to measure shock environments during hardware qualification. The commonly used contact-based sensors, however, interfere with the shock waves and distort the acquired signature, which is a concern not actively discussed in the community. To alleviate these interference issues, engineers at the Jet Propulsion Laboratory are investigating the use of non-intrusive sensors, specifically Laser Doppler Vibrometers, as alternatives to the stud mounted accelerometers. This paper will describe shock simulation tests completed at the Jet Propulsion Laboratory, compare the measurements from stud mounted accelerometers and Laser Doppler Vibrometers, and discuss the advantages and disadvantages of introducing Laser Doppler Vibrometers as alternative sensors for measuring shock environments.

shock testing↗

Spacecraft Doppler Tracking as a Xylophone Detector

This oral presentation discusses spacecraft Doppler tracking in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. Methods are proposed to remove or reduce frequency fluctuations from the data that are caused by multiple circumstances. The resultant data from these proposed methods may have applicability in testing relativity theory.

Spacecraft↗

Progress with On-The-Fly Neutron Doppler Broadening in MCNP

The University of Michigan, ANL, and LANL have been collaborating on a US-DOE-NE University Programs project 'Implementation of On-the-Fly Doppler Broadening in MCNP5 for Multiphysics Simulation of Nuclear Reactors.' This talk describes the project and provides results from the initial implementation of On-The-Fly Doppler broadening (OTF) in MCNP and testing. The OTF methodology involves high precision fitting of Doppler broadened cross-sections over a wide temperature range (the target for reactor calculations is 250-3200K). The temperature dependent fits are then used within MCNP during the neutron transport, for OTF broadening based on cell temperatures. It is straightforward to extend this capability to cover any temperature range of interest, allowing the Monte Carlo simulation to account for a continuous distribution of temperature ranges throughout the problem geometry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal Temperature Grid for Accurate Doppler Kernel Reconstruction

For computational efficiency, both Monte Carlo and deterministic neutron transport codes often rely on pre-tabulated cross section sets and simple interpolation schemes to represent the Doppler broadening of the cross sections at a needed temperature. Accurate accounting of Doppler effects is of paramount importance for reactor analysis since it impacts the power distribution and the reactor response during transients. Temperature interpolation methods for Doppler broadening have traditionally been physically motivated engineering curve-fits, selected upon best-performance criteria on important nuclides.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal scattering law for structure-dependent-Doppler broadening in FLASSH

Traditional Doppler broadening methods assume that target nuclei velocities follow a Maxwell-Boltzmann distribution which inherently assumes that the atoms are a free gas or that their velocities are independent of each other. This approximation is reasonable at high target temperatures and high neutron energies. However, nuclei are not independent: the lattice temperature and chemical binding will define the atomic motion. The thermal scattering law (i.e., TSL or S(α,β)) is a material property which describes the chemical binding and temperature response in terms of available momentum and energy states. In the thermal energy range, this TSL will define the thermal scattering cross sections. In the resonance region, the TSL offers a first-principles description of the probability distribution function for the velocity of the target nuclei. Using the TSL in Doppler broadening captures the structure of the material consistently from the thermal range into the resonance cross sections. In this work, both traditional free-gas and precise TSL Doppler broadening methods for resonance cross section evaluation have been implemented within the Full Law Analysis Scattering System Hub (FLASSH). This framework provides a generalized formulation for evaluating low-lying resonance data and streamlines nuclear data processing methods. TSL data generated using ab initio lattice dynamics (AILD) can be used to broaden cross section libraries in ENDF format for high-fidelity input into reactor physics calculations. These capabilities are demonstrated for the lowest absorption resonances of {sup 238}U in UO{sub 2}, UC and UN. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of Triature Doppler Velocimetry and VISAR

Triature Photonic Doppler Velocimetry (TDV) is an adaptation of Photonic Doppler Velocimetry (PDV) that rejects common-mode data noise after splitting PDV three ways, with each signal 120° out of phase from each other. Testing has demonstrated that TDV also improves temporal resolution from the typical five nanoseconds of PDV to a subnanosecond range. This paper compares the temporal response of TDV with that of PDV and VISAR [velocity interferometer system for any reflector] in an experiment with a subnanosecond (~120-picosecond rise time) shock source. Laboratory tests were performed using a high-power laser on targets of copper and aluminum. A Buce Marshall fast VISAR with a single-point PDV and a prototype TDV were used. A special probe that combined PDV, TDV, and fast VISAR made simultaneous velocity measurements. Breakout velocities of 1.3 km/second on copper and 2.5 km/second on aluminum were observed, where TDV resolved rise times of ~200 ps. This resolution was better than that of a fast VISAR, which can achieve ~500 ps temporal resolution. Test methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Forward Modeling of Radar Doppler Spectrum Width From LES: Implications for Model Evaluation

Large-eddy simulations of an observed single-layer Arctic mixed-phase cloud are analyzed to study the value of forward modeling of profiling millimeter wave cloud radar Doppler spectral width for model evaluation. Individual broadening terms and their uncertainties are quantified for the observed spectral width and compared to modeled broadening terms. Modeled turbulent broadening is narrower than the observed values when the turbulent kinetic energy dissipation rate from the subgrid scale model is used in the forward model. The total dissipation rates, estimated with the subgrid scale dissipation rates and the numerical dissipation rates, agree much better with both the retrieved dissipation rates and those inferred from the power spectra of the simulated vertical air velocity. The comparison of the microphysical broadening provides another evaluative measure of the ice properties in the simulation. To accurately retrieve dissipation rates as well as each broadening term from the observations, we suggest a few modifications to previously presented techniques. First, we show that the inertial subrange spectrum filtered with the radar sampling volume is a better underlying model than the unfiltered -5/3 law for the retrieval of the dissipation rate from the power spectra of the mean Doppler velocity. Second, we demonstrate that it is important to filter out turbulence and remove the layer-mean reflectivity-weighted mean fall speed from the observed mean Doppler velocity to avoid overestimation of shear broadening. Finally, we provide a method to quantify the uncertainty in the retrieved dissipation rates, which eventually propagates to the uncertainty in the microphysical broadening.

54 ENVIRONMENTAL SCIENCES↗

Identification of Acoustic Wave Signatures in the Ionosphere From Conventional Surface Explosions Using MF/HF Doppler Sounding

Here, we present an experiment to detect one ton TNT-equivalent chemical explosions using pulsed Doppler radar observations of isodensity layers in the ionospheric E region during two campaigns. The first campaign, conducted on 15 October 2019, produced potential detections of all three shots. The detections closely resemble the temporal and spectral properties predicted using the InfraGA ray tracing and weakly nonlinear waveform propagation model. Here the model predicts that within 6.5–7.25 min of each shot a waveform peaking between 0.9 and 0.4 Hz will impact the ionosphere at 100 km. As the waves pass through this region, they will imprint their signal on an isodensity layer, which is detectable using a Doppler radar operating at the plasma frequency of the isodensity. Within the time windows of each of the three shots in the first campaign, we detect enhanced wave activity peaking near 0.5 Hz. These waves were imprinted on the Doppler signal probing an isodensity layer at 2.785 MHz near 100 km altitude. Despite these detections, the method appears to be unreliable as none of the six shots from the second campaign, conducted on 10 July 2020 were detected. The observations from this campaign were characterized by an increased acoustic noise environment in the microbarom band and persistent scintillation on the radar returns. These effects obscured any detectable signal from these shots and the baseline noise was well above the detection levels of the first campaign.

47 OTHER INSTRUMENTATION↗

Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasma

Two Doppler spectroscopy diagnostics with complementary capabilities are developed to measure the ion temperatures and velocities of FRC plasmas in the C-2 device. First, the multichord ion doppler diagnostic can simultaneously measure 15 chords of the plasma using an image intensified camera. Second, a single-chord fast-response ion Doppler diagnostic provides much higher faster time response by using a 16-channel photo-multiplier tube array. To study the neutral density of deuterium under different wall and plasma conditions, a highly sensitive eight-channel D-alpha diagnostic has been developed and calibrated for absolute radiance measurements. These spectroscopic diagnostics capabilities, combined with other plasma diagnostics, are helping to understand and improve the field reversed configuration plasmas in the C-2 device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler optical coherence microscopy and tomography applied to inner ear mechanics

While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An eight-channel Doppler backscattering system in the experimental advanced superconducting tokamak

Doppler backscattering system can measure the perpendicular velocity and fluctuation amplitude of the density turbulence with intermediate wavenumber. An eight-channel Doppler backscattering system has been installed in the Experimental Advanced Superconducting Tokamak (EAST), which can probe eight different radial locations simultaneously by launching eight fixed frequencies (55, 57.5, 60, 62.5, 67.5, 70, 72.5, 75 GHz) into plasma. The quasi-optical system consists of circular corrugated waveguide transmission, a fixed parabolic mirror, and a rotatable parabolic mirror which are integrated with quasi-optics front-end of the profile reflectometer inside the vacuum vessel. The incidence angle can be chosen from 5° to 12°, and the wavenumber range is 2–15/cm with the wavenumber resolution Δk/k≤0.21. Ray tracing simulations are used to calculate the scattering locations and the perpendicular wavenumber. The dynamic range of this new eight-channel Doppler backscattering system can be as large as 40 dB in the EAST. In this article, the hardware design, the ray tracing, and the preliminary experimental results in the EAST will be presented.

47 OTHER INSTRUMENTATION↗