Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed energy resources (DER)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Applying the Risk Management Framework: The Distributed Energy Resource Risk Manager

As part of a multiyear effort, the National Renewable Energy Laboratory (NREL) has dedicated resources to understand and identify cybersecurity weaknesses in distributed energy resources (DERs) by performing assessments. Due to a lack of standardization and rapidly increasing adoption of DERs, there is a critical need to address cybersecurity needs for DER systems in an interactive way. Furthermore, federal agencies, which are required to obtain an authority to operate, are challenged by the complexities of including their DERs. To help meet this need, in early 2020, NREL released the Distributed Energy Resources Cybersecurity Framework (DERCF) and accompanying Web application. This process is supported by the Risk Management Framework (RMF) developed by the National Institute of Standards and Technology. This project, referred to as the DERCF RMF application, expands on the existing DERCF work to include methods that support walking a user through the seven RMF steps. The tool will be available for download at no cost from [link ]. The purpose of this paper is to describe the steps the DERCF team at NREL took to understand Steps 1-5 of the RMF process. Additionally, this document will identify future work on the first five steps as well as a plan for Steps 6 and 7.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DEEP Solar: Data DrivEn Modeling and Analytics for Enhanced System Layer ImPlementation

Realizing the SETO 2030 mission of reducing solar energy costs to 3-5 c/kWh will require innovative enabling research on effective, cost-efficient integration of local PV within distribution systems. However, the intermittent and variable nature of PVs compels operators to impose conservative hosting capacity constraints. Given the extremely high variability of (intermittent and unpredictable) solar energy generation, relaxing the capacity constraints (which are currently around 15%) and achieving 100% or greater integration of renewables will require a fundamental transformation of the power grid via the utilization of exponentially larger amounts of AMI enabled fine-grained data. To address the challenges in increasing the penetration of renewable energy based DERs, this project envisions an Enhanced System Layer (ESL) at the distribution network level that is reliable, cost-effective and scalable to millions of Distributed Energy Resources (DERs)/devices. This includes developing: 1) Transformative and highly scalable machine learning based predictive analytics tools that plug into distribution system planning and provide real-time situational awareness at the distribution level for short and long-term operational planning. The tools will be built using novel data-driven energy models of millions of active nodes with AMI, 2) Adaptive stochastic analysis and optimization algorithms for real-time grid operations, 3) Dynamic Scenario Analysis using parallel Cloudenabled implementations with < 1 minute computational cycle times.

14 SOLAR ENERGY↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

SolarExPert: Large-Scale OPF, DSSE and HIL

This presentation, part of the ADMS Test Bed Webinar Series, discusses how to accelerate industry adoption of ADMS to improve normal operations with high levels of distributed energy resources (DERs) and improve resilience and reliability.

ADMS↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Extremum seeking control of distributed energy resources with decaying dither and equilibrium-based switching

Embodiments relate to an operating system coupled to and controlling at least one Distributed Energy Resource (DER) in a smart grid and includes an electricity distribution network and a 2-dimensional Extremum Seeking (2D-ES) controller coupled to network. The electricity distribution network has first and second inputs and one output and maps all active power and reactive power inputs to the smart grid providing measurements of an objective function. The 2D-ES controller controls the DER and includes an active power loop and a reactive power loop. The active power loop is in communication with the first input and the output, governs active power contribution, and receives measurements of the objective function which contain static and oscillatory components. The reactive power loop is in communication with the second input and the output, governs reactive power contribution, and receives measurements of the objective function which contain static and oscillatory components.

Arnold, Daniel↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

An Electromagnetic Transient and Three-Phase Phasor Co-Simulation Platform for Studying Distribution System Transients with High Pentration of DERs

Inverter vendors usually have electro-magnetic transient (EMT) models of distributed energy resources (DERs) for validation purposes and these types of models are usually black-boxed considering intellectual property (IP) protection. Limited by small simulation time step for the entire power system network, studying the system-level responses of DERs in EMT simulators is more time-consuming as the network size increases. Meanwhile, vendors usually do not have inverter models that can be used in three-phase phasor-domain simulators. This paper proposes a platform that can dynamically co-simulate the EMT inverter models and three-phase phasor-domain distribution networks considering high penetration of inverter-based DERs. This platform is very useful for evaluating the impacts of vendor-provided black-box DER model on distribution system dynamics. The co-simulation platform is validated against the full EMT model using a simple two-inverter test system and tested using IEEE 34-node test feeder.

Liu, Yuan↗

Impact of DER Communication Delay in AGC: Cyber-Physical Dynamic Co-Simulation: Preprint

Distributed energy resource (DER) frequency regulations are promising technologies for future grid operation. Unlike conventional generators, DERs might require open communication networks to exchange signals with control centers, possibly through DER aggregators; therefore, the impacts of the communication variations including the latency on the system frequency stability need to be investigated. This paper develops a cyber-physical dynamic simulation (CPDS) model based on the Hierarchical Engine for Large-Scale Co-Simulation (HELICS) to evaluate the impact of the communication variations, such as delays in DER frequency regulations. The feasible delay range can be obtained under different AGC parameter settings. The results show that the risk of instability generally increases with the communication delay and that the difference of AGC provided from DER and conventional generation units should be recognized when designing frequency regulation controllers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗