Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Electroweak loop contributions to the direct detection of wino dark matter

Electroweak loop corrections to the matrix elements for the spin-independent scattering of cold dark matter particles on nuclei are generally small, typically below the uncertainty in the local density of cold dark matter. However, as shown in this paper, there are instances in which the electroweak loop corrections are relatively large, and change significantly the spin-independent dark matter scattering rate. An important example occurs when the dark matter particle is a wino, e.g., in anomaly-mediated supersymmetry breaking (AMSB) and pure gravity mediation (PGM) models. We find that the one-loop electroweak corrections to the spin-independent wino LSP scattering cross section generally interfere constructively with the tree-level contribution for AMSB models with negative Higgsino mixing, μ < 0, and in PGM-like models for both signs of μ, lifting the cross section out of the neutrino fog and into a range that is potentially detectable in the next generation of direct searches for cold dark matter scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zooming in on light relic neutralinos by direct detection and measurements of galactic antimatter

The DAMA Collaboration has recently analyzed its data of the extensive WIMP direct search (DAMA/NaI) which detected an annual modulation, by taking into account the channeling effect which occurs when an ion traverses a detector with a crystalline structure. Among possible implications, this Collaboration has considered the case of a coherent weakly interacting massive particle (WIMP)-nucleus interaction and then derived the form of the annual modulation region in the plane of the WIMP-nucleon cross section versus the WIMP mass, using a specific modeling for the channeling effect. In the present paper we first show that light neutralinos fit the annual modulation region also when channeling is taken into account. To discuss the connection with indirect signals consisting in galactic antimatter, in our analysis we pick up a specific galactic model, the cored isothermal-sphere. In this scheme we determine the sets of supersymmetric models selected by the annual modulation regions and then prove that these sets are compatible with the available data on galactic antiprotons. We comment on implications when other galactic distribution functions are employed. Finally, we show that future measurements on galactic antiprotons and antideuterons will be able to shed further light on the populations of light neutralinos singled out by the annual modulation data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposal for gravitational direct detection of dark matter

The only coupling dark matter is guaranteed to have with the standard model is through gravity. Here we propose a concept for direct dark matter detection using only this gravitational coupling. We suggest that an array of quantum-limited mechanical impulse sensors may be capable of detecting the correlated gravitational force created by a passing dark matter particle. We consider the effects of irreducible noise from couplings of the sensors to the environment and noise due to the quantum measurement process. We show that the signal from Planck-scale dark matter is in principle detectable using a large number of gram-scale sensors in a meter-scale array with sufficiently low quantum noise, and discuss some experimental challenges en route to achieving this target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the neutron background in an HPGe target for WIMP direct detection when using a reactor neutrino detector as a neutron veto system

A direct WIMP (weakly interacting massive particle) detector with a neutron veto system is designed to better reject neutrons. The experimental configuration is studied in this paper involves 984 Ge modules placed inside a reactor-neutrino detector. The neutrino detector is used as a neutron veto device. The neutron background for the experimental design is estimated using the Geant4 simulation. The results show that the neutron background can decrease to O(0.01) events per year per tonne of high-purity germanium and it can be ignored in comparison with electron recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEW COMPLETENESS METHODS FOR ESTIMATING EXOPLANET DISCOVERIES BY DIRECT DETECTION

We report on new methods for evaluating realistic observing programs that search stars for planets by direct imaging, where observations are selected from an optimized star list and stars can be observed multiple times. We show how these methods bring critical insight into the design of the mission and its instruments. These methods provide an estimate of the outcome of the observing program: the probability distribution of discoveries (detection and/or characterization) and an estimate of the occurrence rate of planets ({eta}). We show that these parameters can be accurately estimated from a single mission simulation, without the need for a complete Monte Carlo mission simulation, and we prove the accuracy of this new approach. Our methods provide tools to define a mission for a particular science goal; for example, a mission can be defined by the expected number of discoveries and its confidence level. We detail how an optimized star list can be built and how successive observations can be selected. Our approach also provides other critical mission attributes, such as the number of stars expected to be searched and the probability of zero discoveries. Because these attributes depend strongly on the mission scale (telescope diameter, observing capabilities and constraints, mission lifetime, etc.), our methods are directly applicable to the design of such future missions and provide guidance to the mission and instrument design based on scientific performance. We illustrate our new methods with practical calculations and exploratory design reference missions for the James Webb Space Telescope (JWST) operating with a distant starshade to reduce scattered and diffracted starlight on the focal plane. We estimate that five habitable Earth-mass planets would be discovered and characterized with spectroscopy, with a probability of zero discoveries of 0.004, assuming a small fraction of JWST observing time (7%), {eta} = 0.3, and 70 observing visits, limited by starshade fuel.

79 ASTRONOMY AND ASTROPHYSICS↗

Precluding nonlinear ISI in direct detection long-haul fiber optic systems

Long-distance, high-rate fiber optic systems employing directly modulated 1.55-micron single-mode lasers and conventional single-mode fiber suffer severe intersymbol interference (ISI) with a large nonlinear component. A method of reducing the nonlinearity of the ISI, thereby making linear equalization more viable, is investigated. It is shown that the degree of nonlinearity is highly dependent on the choice of laser bias current, and that in some cases the ISI nonlinearity can be significantly reduced by biasing the laser substantially above threshold. Simulation results predict that an increase in signal-to-nonlinear-distortion ratio as high as 25 dB can be achieved for synchronously spaced samples at an optimal sampling phase by increasing the bias current from 1.2 times threshold to 3.5 times threshold. The high SDR indicates that a linear tapped delay line equalizer could be used to mitigate ISI. Furthermore, the shape of the pulse response suggests that partial response precoding and digital feedback equalization would be particularly effective for this channel.

Swenson, Norman L.↗

Dark matter clusters and time correlations in direct detection experiments

Assuming that dark matter (DM) efficiently clusters on various scales we analyse the possible impact on direct DM searches. For certain sizes and densities of DM clusters, mutual detector-cluster encounters may occur only once a year or every several years leading to the apparent failure of individual experiments searching for DM to discover it. If, however, encounters with Earth size and up to 10 4 times bigger clusters occur about once a year, then finding time correlations between events in different underground detectors can lead to DM discovery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct detection of XUV radiation with a CCD

A thinned CCD illuminated from the back has been used for direct imaging in the 584 and 304 A resonance lines of helium and in the 736 A line of neon. During operation, the CCD was cooled to minus 10 C and output was displayed on a CRT screen or in numerical printout. The results demonstrate that the back-illuminated CCD can be used as a position-sensitive flux detector with good imaging properties over a wide range of photon energies, including the extreme ultraviolet.

Burstein, P.↗

The Circumstellar Imager: Direct detection of extra-solar planetary systems

The Astrometric Imaging Telescope (AIT) is designed to probe the circumstellar environment by both direct imaging and indirect astrometric measurements. The Circumstellar Imager (CI) is a coronagraphic camera and is the direct imaging component of the AIT. The CI is designed to obtain high-sensitivity images of the circumstellar region. It provides crucial non-inferential information relating to the frequency, origin, and evolution of planetary systems and all forms of circumstellar matter. Such imaging is usually limited by the scattered and diffracted light halos of the star itself, which are greatly suppressed in the CI by mating a novel high-efficiency coronagraph with a phase-compensated optical system. For faint point sources in the circumstellar region, the CI will have a sensitivity in excess of 5 magnitudes fainter than the as-designed Hubble Space Telescope (HST). Laboratory data are shown for the coronagraph, which, in a diffraction-limited environment, is capable of suppressing the stellar diffraction sidelobes by several orders of magnitude without significant sacrifice of field of view. In order to realize the high rejection levels inherent in the coronagraph design, it is necessary to limit scatter in the optical systems, imposing a mid-spatial frequency figure error requirement an order of magnitude smaller than that of the HST. Experimental data directed toward meeting this requirement are also shown.

Ftaclas, Christ↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

The ultraviolet photochemistry of diacetylene - Direct detection of primary products of the metastable C4H2* + C4H2 reaction

The products of diacetylene's ultraviolet photochemistry over the 245-220 nm region were directly determined in experiments where C4H2 was excited within a small reaction tube attached to a pulsed nozzle. The products formed in the collisions of C4H2* with C4H2 were subsequently ionized by vacuum UV radiation (at 118 nm) in the ion source of a time-of-flight mass spectrometer. It was found that the reaction of C4H2* with C4H2 produces C6H2 (+C2H2), C8H2 (+2H,H2), and C8H3 (+H), confirming the results of Glicker and Okabe (1987). Under certain conditions, secondary products were observed. Mechanisms for the observed reactions are proposed.

Bandy, Ralph E.↗

DIRECT DETECTION OF SEASONAL CHANGES ON TRITON WITH HUBBLE SPACE TELESCOPE

Triton is one of the few bodies in the solar system with observed cryo-volcanic activity, in the form of plumes at its south pole, which suggests large-scale surface volatile transport over time. Triton's large variations in obliquity have motivated prior predictions of changing atmospheric column densities of several orders of magnitude, driven by seasonal evaporation of surface volatiles. Using the Hubble Space Telescope, we directly imaged Triton's surface and have detected large-scale differences in increased and decreased reflectance when compared with Voyager data at UV, visual, and methane-band wavelengths. Our surface map shows regions of increased brightness at near-equatorial latitudes and near the Neptune-facing side, and darkened regions near longitudes of {+-}180{sup 0}, indicating the presence of ongoing seasonal volatile transport.

79 ASTRONOMY AND ASTROPHYSICS↗

Harmonics in the dark-matter sky: directional detection in the Fourier-Bessel basis

Details about the velocity distribution of weakly interacting massive particle (WIMP) dark matter in our galaxy may be revealed by nuclear-recoil detectors with directional sensitivity. Previous studies have assumed that the velocity distribution takes a simple functional form characterized by a small number of parameters. More recent work has shown that basis-function expansions may allow for more general parameterization; such an approach has been considered for both the one-dimensional speed and momentum distributions, and also for three-dimensional velocity distributions obeying certain equilibrium conditions. In this work, I extend this basis-function approach to allow for arbitrary velocity distributions by working in the Fourier-Bessel basis, deriving an analytic expression for the directional recoil spectrum. Such an approach is completely general, and may be useful if the velocity distribution is too complex to be characterized by simple functional forms or is not completely virialized. Results concerning the three-dimensional Radon transform of the Fourier-Bessel basis functions may be of general interest for tomographic applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategy for Direct Detection of Chiral Phonons with Phase-Structured Free Electrons

Chiral phonons possessing valley pseudoangular momentum (PAM) underlie a diversity of quantum phenomena of fundamental and applied importance, but are challenging to probe directly. We show that deficiencies of typical momentum-resolved electron energy loss measurements that make it impossible to distinguish the PAM of chiral phonons can be overcome by introducing pinwheel free electron states with well-defined PAM. Transitions between such states generate 2D periodic arrays of in-plane field vortices with polarization textures tailored to selectively couple to desired chiral mode symmetries.

chirality↗

Dark matter direct detection constraints on the minimal supersymmetric standard model and implications for LHC Higgs boson searches

Assuming the lightest neutralino solely composes the cosmic dark matter, we examine the constraints of the CDMS-II and XENON100 dark matter direct searches on the parameter space of the minimal supersymmetric standard model (MSSM) Higgs sector. We find that the current CDMS-II/XENON100 limits can exclude some of the parameter space which survive the constraints from the dark matter relic density and various collider experiments. We also find that in the currently allowed parameter space, the charged Higgs boson is hardly accessible at the LHC for an integrated luminosity of 30 fb{sup -1}, while the neutral non-SM (standard model) Higgs bosons (H,A) may be accessible in some allowed region characterized by a large {mu}. The future XENON100 (6000 kg-days exposure) will significantly tighten the parameter space in case of nonobservation of dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct detection of Pb in urine and Cd, Pb, Cu, and Ag in natural waters using electrochemical sensors immobilized with DMSA functionalized magnetic nanoparticles

Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics including toxic metals. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA-Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA-Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g/L of DMSA-Fe3O4, the sensor could detect background level of Pb (< 1 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%R.S.D of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (< 1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.

Environmental Molecular Sciences Laboratory↗