Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

{beta}- and {gamma}-spectroscopy study of {sup 119}Pd and {sup 119}Ag

Neutron-rich Pd-119 nuclei were produced in fission of natural uranium, induced by 25-MeV protons. Fission fragments swiftly extracted with the Ion Guide Isotope Separation On-Line method were mass separated using a dipole magnet and a Penning trap, providing mono-isotopic samples of Pd-119. Their beta(-) decay was measured with gamma gamma- and beta gamma-spectroscopy methods using low-energy germanium detectors and a thin plastic scintillator. Two distinct nuclear-level structures were observed in Ag-119, based on the 1/2(-) and 7/2(+) isomers reported previously. The beta(-)decay work was complemented by a prompt-gamma study of levels in Ag-119 populated in spontaneous fission of (252)cf, performed using the Gammasphere array of germanium detectors. Contrary to previous suggestions, our data show that the 1/2(-) isomer is located below the 7/2(+) isomer and is proposed as a new ground state of Ag-119 with the 7/2(+) isomer excitation energy determined to be 33.4 keV. Our data indicate that there are two beta unstable isomers in Pd-119, a proposed ground state of Pd-119 with tentative spin 1/2(-) or 3/2(+) and a half-life of 0.88 s and the other one about 350 keV above, having spin (11/2(-)) and a half-life of 0.85 s. The higher-energy isomer probably decays to the 1/2(-) or 3/2(+) ground state via a gamma cascade comprising 18.7-219.8-X-keV transitions. The unobserved isomeric transition with energy X approximate to 100 keV probably has an E3 multipolarity. Its hindrance factor is significantly lower than for analogous E3 isomeric transitions in lighter Pd isotopes, suggesting an oblate deformation of levels in Pd-119. Oblate configurations in Ag-119 are discussed also.

Kurpeta, J↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the muon content of inclined air showers using AERA and the water-Cherenkov detectors of the Pierre Auger Observatory

We present a novel approach for assessing the muon content of air showers with large zenith angles on a combined analysis of their radio emission and particle footprint. We use the radiation energy reconstructed by the Auger engineering radio array (AERA) as an energy estimator and determine the muon number independently with the water-Cherenkov detector array of the Pierre Auger Observatory, deployed on a 1500 m grid. We focus our analysis on air showers with primary energy above 4 EeV to ensure full detection efficiency. Over approximately ten years of accumulated data, we identify a set of 40 high-quality events that are used in the analysis. The estimated muon contents in data are compatible with those for iron primaries as predicted by current-generation hadronic interaction models. This result can be interpreted as a deficit of muons in simulations as a lighter mass composition has been established from X max measurements. This muon deficit was already observed in previous analyses of the Auger Collaboration and is confirmed using hybrid events that include radio measurements for the first time.

Abdul Halim, A. [Adelaide U.]↗

Search for photons above 10 19 eV with the surface detector of the Pierre Auger Observatory

We use the surface detector of the Pierre Auger Observatory to search for air showers initiated by photons with an energy above 10 19 eV. Photons in the zenith angle range from 30° to 60° can be identified in the overwhelming background of showers initiated by charged cosmic rays through the broader time structure of the signals induced in the water-Cherenkov detectors of the array and the steeper lateral distribution of shower particles reaching ground. Applying the search method to data collected between January 2004 and June 2020, upper limits at 95% CL are set to an E -2 diffuse flux of ultra-high energy photons above 10 19 eV, 2 × 10 19 eV and 4 × 10 19 eV amounting to 2.11 × 10 -3 , 3.12 × 10 -4 and 1.72 × 10 -4 km -2 sr -1 yr -1 , respectively. While the sensitivity of the present search around 2 × 10 19 eV approaches expectations of cosmogenic photon fluxes in the case of a pure-proton composition, it is one order of magnitude above those from more realistic mixed-composition models. The inferred limits have also implications for the search of super-heavy dark matter that are discussed and illustrated.

ultra high energy photons and neutrinos↗

Conceptual design of DIII-D experiments to diagnose the lifetime of spin polarized fuel

Abstract In magnetic fusion experiments, the cross sections for the D-T and D- 3 He fusion reactions are increased by as much as 50% if the fuel remains spin polarized parallel to the magnetic field. The goal of this study is to assess the feasibility of lifetime measurements of spin polarization, in magnetic fusion relevant conditions, on the DIII-D tokamak using relative changes in charged fusion product (CFP) loss measurements that depend upon the differential fusion cross section d σ /dΩ. Relative measurements that capture changes in the escaping CFP pitch, poloidal, and energy distributions are studied in two realistic TRANSP calculated plasma scenarios: (a) vector-polarized 3 He and D pellets are injected into a hot hydrogen plasma to produce thermonuclear reactions, and (b) a tensor-polarized deuterium pellet is injected into an L-mode hydrogen background plasma that includes unpolarized 3 He neutral beam injection. Ideal CFP signals in both scenarios show substantial pitch sensitivity to polarization for 14.7 MeV proton detection at a poloidal angle of − 56 ∘ (on the outer wall in the ion ∇ B direction), and strong sensitivity to polarization for 3.6 MeV alpha flux detection by an array of poloidal detectors. Energy-resolved measurements of 14.7 MeV protons are also sensitive to the degree of polarization for the − 56 ∘ port in the beam-plasma scenario. A realistic assessment of CFP signals in the thermonuclear scenario show count rates in the range of 2 × 10 4 cps for pitch-resolved proton detection and 2 × 10 5 cps for alpha flux measurements. Reduced chi-squared χ r 2 calculations show polarization lifetime measurements are feasible for either proton or alpha detection of both enhanced or suppressed polarization for the thermonuclear scenario. Measurements of gamma rays produced in the weak D + 3 He → γ + 5 Li branch complement the CFP measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$β$-delayed-neutron studies of 135,136 Sb and 140 I performed with trapped ions

In this work, Beta-delayed-neutron $(βn)$ spectroscopy was performed using the Beta-decay Paul Trap and an array of radiation detectors. The $βn$ branching ratios and energy spectra for 135,136 Sb and 140 I were obtained by measuring the time of flight of recoil ions emerging from the trapped ion cloud. These nuclei are located at the edge of an isotopic region identified as having $βn$ branching ratios that impact the $r$-process abundance pattern around the A ≈ 130 peak. For 135,136 Sb and 140 I, $βn$ branching ratios of 14.6(13)%, 17.6(29)%, and 7.6(28)% were determined, respectively. The $βn$ energy spectra obtained for 135 Sb and 140 I are compared with results from direct neutron measurements, and the $βn$ energy spectrum for 136 Sb has been measured for the first time.

42 ENGINEERING↗

Deuteron Evaporation from N = Z Compound Nuclei

Deuteron evaporation was observed from the N = Z compound nuclei 52 Fe ⋆ , 56 Ni ⋆ , and 64 Ge ⋆ in an experiment conducted at Argonne National Laboratory, USA. The experiment included a novel combination of two highly pixelated double-sided Si-strip detectors inside the Microball chargedparticle detection array, allowing for unequivocal discrimination of evaporated deuterons from protons and α particles. In conjunction with the Gammasphere array, Neutron Shell, and additional ancillary detectors, decay paths into various residual nuclei were investigated. The study provides insights into the competition of deuteron vs. proton-neutron evaporation as a function of available excitation energy and populated angular momentum. Results are interpreted using a statistical evaporation formalism for multiple subsequent particle emissions. The decisive factor in the comparison appears to be the available excitation energy in the residual system, with single nucleon evaporation preferred over deuteron evaporation for higher excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing and Modeling the Influence of Geometry on the Performance of Superconducting Nanowire Cryotrons

The scaling of superconducting nanowire detectors to larger arrays is often limited by room-temperature-readout cabling. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address this limitation by performing signal processing on chip. In this study, we characterize key performance metrics of the nanocryotron to elucidate its potential as a logical element in cryogenic integrated circuits and develop an electro-thermal model to connect material parameters with device performance. We find that the performance of the nanocryotron depends on the device geometry, and trade-offs are associated with optimizing the gain, jitter, and energy dissipation. Here, we demonstrate that nanocryotrons fabricated on niobium nitride can achieve a grey zone less than 210 nA wide for a 5 ns long input pulse corresponding to a maximum achievable gain of 48 dB, an energy dissipation of less than 20 aJ per operation, and a jitter of less than 60 ps.

Superconductor↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Quantum Devices for Neutrino and Rare Particle Detection (Final Report)

This report summarizes the technical work completed under the DOE-QuanISED program. This grant allowed the MIT group --and associated groups on the project, including UMass Amherst and Argonne National Laboratory -- to explore the use of superconducting bolometers for the purpose of neutrino and low mass dark matter detection. These low threshold bolometric detection techniques have wide applicability in nuclear and particle physics, including searching for low mass weakly-interacting dark matter; detecting neutrinos via coherent neutrino scattering; searching for axions and nuclear non-proliferation. In addition, we explored how using techniques readily used by the quantum computing community–such as multiplexed microwave resonators and quantum amplifiers—could be used as a low noise readout scheme for an array of superconducting detectors. We briefly summarized the accomplishments under the project, and what future research directions have spawned from this research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for Surrogate Neutron Capture Measurements with Radioactive Ion Beams and GODDESS

Neutron capture reactions are responsible for the synthesis of almost all of the elements heavier than iron through the slow s-process, that proceeds close to the line of stability, and the rapid r-process, with very neutron-rich waiting points. Uncertainties in (n,γ) rates in neutron rich nuclei, especially near closed neu- tron shells, can have significant impact [1] on the predictions of final abundances for different astrophysical scenarios for the r process. Understanding (n,γ) rates on neutron-rich fission fragments is also important for nuclear forensics and stockpile stewardship science. Ratkiewicz et al. [2 and references therein] has recently demonstrated that the (d,pγ) reaction is a valid surrogate for (n,γ), where the formation of the compound nucleus from the breakup of the deuteron has been calculated in a reaction model and the subsequent measured gamma-decay probabilities are reproduced with standard level density and strength functions in a Bayesian approach. In parallel to the surrogate validation efforts, we have demonstrated that the (d,pγ) reaction can be measured in inverse kinematics with Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) [3] where the Gammasphere array of Compton-suppressed HPGe detectors is coupled to the Oak Ridge Rutgers University Barrel Array of position-sensitive silicon strip detectors. During the commissioning campaign we measured the (d,pγ) reaction with 134 Xe and 95 Mo beams, the latter to demonstrate the surrogate method in inverse kinematics. The present talk will present preliminary results from this campaign including γ-decay probabilities and prospects for surrogate (n,γ) measurements with 143 Ba fission-fragment beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved detectors for quantum ghost imaging

Quantum ghost imaging is a method that utilizes the correlated detection of two photons to generate an image. One photon is detected by an imaging sensor and the other by a single-element bucket detector. The selection of the imaging sensor and its capabilities relative to the bucket detector impact the quality of the ghost images. This work examines a SPAD array and a photocathode detector as imaging sensors for quantum ghost imaging. We discuss how to achieve optimal images using these two technologies. We also demonstrate that these devices are able to generate ghost images at 1Hz frame rates, expanding the technique to biologically relevant time scales.

36 MATERIALS SCIENCE↗

The UHECR dipole and quadrupole in the latest data from the original Auger and TA surface detectors

The sources of ultra-high-energy cosmic rays are still unknown, but assuming standard physics, they are expected to lie within a few hundred megaparsecs from us. Indeed, over cosmological distances cosmic rays lose energy to interactions with background photons, at a rate depending on their mass number and energy and properties of photonuclear interactions and photon backgrounds. The universe is not homogeneous at such scales, hence the distribution of the arrival directions of cosmic rays is expected to reflect the inhomogeneities in the distribution of galaxies; the shorter the energy loss lengths, the stronger the expected anisotropies. Galactic and intergalactic magnetic fields can blur and distort the picture, but the magnitudes of the largest-scale anisotropies, namely the dipole and quadrupole moments, are the most robust to their effects. Measuring them with no bias regardless of any higher-order multipoles is not possible except with full-sky coverage. In this work, we achieve this in three energy ranges (approximately $8$--$16~EeV$, $16$--$32~EeV$, and $32$--$\infty~EeV$) by combining surface-detector data collected at the Pierre Auger Observatory until 2020 and at the Telescope Array (TA) until 2019, before the completion of the upgrades of the arrays with new scintillator detectors. We find that the full-sky coverage achieved by combining Auger and TA data reduces the uncertainties on the north-south components of the dipole and quadrupole in half compared to Auger-only results.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the AMIGA embedded system for data acquisition

The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km 2 large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down to about 1017 eV. At the depth of 2.3 m the electromagnetic component of cosmic ray showers is almost entirely absorbed so that the buried scintillators provide an independent and direct measurement of the air showers muon content. This work describes the design and implementation of the AMIGA embedded system, which provides centralized control, data acquisition and environment monitoring to its detectors. The presented system was firstly tested in the engineering array phase ended in 2017, and lately selected as the final design to be installed in all new detectors of the production phase. The system was proven to be robust and reliable and has worked in a stable manner since its first deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗