Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Depth of Discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Rise time and response measurements on a LiSOCl2 cell

Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.

Bastien, Caroline↗

Results of deep DoD life cycle tests at high rates on 12Ah NiCd cells

A 12 Ah Nickel-Cadmium (NiCd) Low Earth Orbit (LEO) life cycle test that induced 47 percent more deep Depth Of Discharge cycles by mixing them with shallow DOD cycles is discussed. The test showed how aggressive recharging to a C/D ratio of 1.15 nearly doubled performance over cycling below a C/D of 1.11.

Panneton, Paul E.↗

Capacity loss on storage and possible capacity recovery for HST nickel-hydrogen cells

Negatively precharged nickel hydrogen cells will experience a useable capacity loss during extended open circuit storage periods. Some of the lost capacity can be recovered through cycling. Capacity recovery through cycling can be enhanced by cycling at high depths of discharge (DOD). The most timely procedure for recovering the faded capacity is to charge the cell fully and allow the cell to sit open-circuit at room temperature. This procedure seems to be effective in part because of the enlarged structure of the active materials. The compounds that formed during storage at the low electrode potentials can more easily dissolve and redistribute. All of the original capacity cannot be recovered because the lattice structure of the active material is irreversibly altered during storage. The recommendation is to use positively precharged cells activated with 26 percent KOH if possible. In aerospace applications, the benefits of negative precharge are offset by the possibility of delays and storage periods.

Lowery, John E.↗

Progress in the development of lightweight nickel electrode

The use of the lightweight nickel electrode, in place of the heavy-sintered state-of-the-art nickel electrode, will lead to improvements in specific energy and performance of the nickel-hydrogen cell. Preliminary testing indicates that a nickel fiber mat is a promising support candidate for the nickel hydroxide active material. Nickel electrodes made from fiber mats, with nickel and cobalt powder added to the fiber, were tested at LeRC. To date, over 8000 cycles have been accumulated, at 40 percent depth-of-discharge, using the lightweight fiber electrode, in a boiler plate nickel-hydrogen cell.

Britton, Doris L.↗

Hughes advanced nickel-cadmium batteries: An update

After delivering a significant data base on boilerplate and prototype advanced nickel cadmium (Ni/Cd) battery cells, Hughes decided to start using the Advanced Ni/Cd batteries on several of their flight programs. The advanced cell can been operated at 80 percent depth of discharge (DOD) for more than 10 years, and possibly 15 years, in geosynchronous earth orbit (GEO) applications. This cell offers an important weight saving over the standard Ni/Cd cell that is usually only operated at 50 to 60 percent DOD in GEO applications. The negative and positive electrodes are manufactured using electrochemical deposition methods which reduce the sinter corrosion problems encountered by the chemical deposition process used in the standard cells. The degradable nylon separators used in standard cells was replaced by polymer impregnated Zirconia separators.

Bogner, R. Sam↗

Cycle life characteristics of Li-TiS2 cells

The development of lithium ambient temperature rechargeable cells is discussed. During the development process, we hope to gain a greater understanding of the materials and the properties of the Li-TiS2 cell and its components. The design will meet the requirements of 100 Wh/Kg and 1000 cycles, at 50 percent depth-of-discharge, by 1995.

Deligiannis, Frank↗

Multiple cell CPV nickel-hydrogen battery

Johnson Controls, Inc. has developed a multiple cell CPV nickel hydrogen battery that offers significant weight, volume, and cost advantages for aerospace applications. The baseline design was successfully demonstrated through the testing of a 26-cell prototype, which completed over 7000 44 percent depth-of-discharge low earth orbit cycles. Prototype designs using both nominal 5 and 10 inch diameter vessels are currently being developed for a variety of customers and applications.

Jones, Ken R.↗

Electrochemical impregnation and cycle life of lightweight nickel electrodes for nickel-hydrogen cells

Development of a high specific energy nickel electrode is the main goal of the lightweight nickel electrode program at NASA-Lewis. The approach was to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen cell. Lightweight plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. The electrodes are life cycle tested in a low earth orbit regime at 40 and 80 percent depths-of-discharge.

Britton, Doris L.↗

TOPEX electrical power system

The TOPEX mission requirements which impact the power requirements and analyses are presented. A description of the electrical power system (EPS), including energy management and battery charging methods that were conceived and developed to meet the identified satellite requirements, is included. Analysis of the TOPEX EPS confirms that all of its electrical performance and reliability requirements have been met. The TOPEX EPS employs the flight-proven modular power system (MPS) which is part of the Multimission Modular Spacecraft and provides high reliability, abbreviated development effort and schedule, and low cost. An energy balance equation, unique to TOPEX, has been derived to confirm that the batteries will be completely recharged following each eclipse, under worst-case conditions. TOPEX uses three NASA Standard 50AH Ni-Cd batteries, each with 22 cells in series. The MPS contains battery charge control and protection based on measurements of battery currents, voltages, temperatures, and computed depth-of-discharge. In case of impending battery depletion, the MPS automatically implements load shedding.

Chetty, P. R. K.↗

Nickel-hydrogen cell low-earth-orbit life test update

When individual pressure vessel (IPV) nickel-hydrogen (Ni/H2) cells were selected as the energy storage system for Space Station Freedom in March of 1986, a limited database existed on life and performance characteristics of these cells in a low earth orbit (LEO) regime. Therefore, NASA LeRC initiated a Ni/H2 cell test program with the primary objectives of building a test facility, procuring cells from existing NASA contracts, and screening several cell designs by life testing in a LEO 35 percent depth of discharge (DOD) scenario. A total of 40 cells incorporating 13 designs were purchased from Yardney, Hughes, and Eagle-Picher. Thirty-two of the cells purchased were 65 A-hr nameplate capacity and eight cells were 50 A-Hr. Yardney and Eagle-Picher cells were built with both the Air Force recirculating and the advanced back-to-back electrode stack configurations and incorporated 31 and 26 percent KOH. Acceptance testing of the first delivered cells began in March of 1988, with life testing following in September of that year. Performance comparisons of these cells are made here while specifically addressing life test data relative to the design differences.

Frate, David T.↗

Nickel-hydrogen LEO cycling at 20-50 percent DOD

Two NiH2 two-cell packs made up of engineering cells built according to the Hubble Space Telescope design (EPI RNH 90-3) are currently being low-earth-orbit (LEO) cycled at 20-50 percent depth of discharge (DOD). The cells were manufactured by Eagle-Picher Industries, Inc., and activated with electrolyte (KOH) concentrations of 26 percent (pack No.1) and 31 percent (pack No.2), for use during evaluation of the HST cell design. The cells have been grouped according to electrolyte concentration but follow the same test schedule for comparison. This test was set up to study the behavior of NiH2 cells having differing electrolyte concentrations, when operated at relatively high DOD (20-50 percent) in a LEO cycling program. The test was designed specifically to allow the cells to pick their own recharge ratio for varying DOD and varying EOC (end of charge) voltages. The cells are being cycled in a simulated 96-min orbit with 60-min charge and 36-min discharge where an EOC cutoff voltage controls high-rate charging. EOC cutoff voltages vary between 1.48 V and 1.56 V.

Lowery, John E.↗

The status of rechargeable Li-TiS2 cell technology

Ambient temperature rechargeable lithium-titanium disulfide (Li-TiS2) cells are under development at JPL for future NASA missions. The development of this technology has involved assessment and selection of electrolytes, optimization of cell design, fabrication of cells, preparation of TiS2 cathodes, and evaluation of lithium alloys. This effort has resulted in achieving a major milestone, completing 700 cycles at 50 percent depth of discharge in 1-Ah cells fabricated in house.

Halpert, G.↗

Cycle life status of SAFT VOS nickel-cadmium cells

The SAFT prismatic VOS Ni-Cd cells have been flown in geosynchronous orbit since 1977 and in low earth orbit since 1983. Parallel cycling tests are performed by several space agencies in order to determine the cycle life for a wide range of temperature and depth of discharge (DOD). In low Earth orbit (LEO), the ELAN program is conducted on 24 Ah cells by CNES and ESA at the European Battery Test Center at temperatures ranging from 0 to 27 C and DOD from 10 to 40 percent. Data are presented up to 37,000 cycles. One pack (X-80) has achieved 49,000 cycles at 10 C and 23 percent DOD. The geosynchronous orbit simulation of a high DOD test is conducted by ESA on 3 batteries at 10 C and 70, 90, and 100 percent DOD. Thirty-one eclipse seasons are completed, and no signs of degradation have been found. The Air Force test at CRANE on 24 Ah and 40 Ah cells at 20 C and 80 percent DOD has achieved 19 shadow periods. Life expectancy is discussed. The VOS cell technology could be used for the following: (1) in geosynchronous conditions--15 yrs at 10-15 C and 80 percent DOD; and (2) in low earth orbit--10 yrs at 5-15 C and 25-30 percent DOD.

Goualard, Jacques↗

Hubble Space Telescope nickel hydrogen battery system briefing

The topics covered are presented in viewgraph form and include the following: the Hubble Space Telescope (HST) Mission; system constraints; battery specification; battery module; simplified block diagram; cell design summary; present status; voltage decay; system depth of discharge; pressure since launch; system capacity; eclipse time vs. trickle charge; capacity test objectives; and capacity during tests.

Nawrocki, David↗

Lightweight nickel electrodes for nickel/hydrogen cells

Thick nickel electrodes with lightweight substrate material have been prepared and tested in Ni/H2 boilerplate cells containing 26 percent KOH electrolyte. Lightweight substrates used were either 85 or 90 percent in porosity and either 0.8 or 2 mm in thickness, respectively, compared with 80 to 82 percent porosity and 0.75 to 0.8 mm thickness of the state-of-the-art sintered plaque substrate. All of these thick electrodes had substantially improved theoretical (or chemical) capacity over that of state-of-the-art sintered nickel plaque electrodes. However, utilization of the active material was low (65 to 80 percent) compared with that of the state-of-the-art electrodes (approximately 90 percent) in 26 percent KOH. Due to this low utilization, the electrodes using 85 percent porous substrates did not show any advantage over the state-of-the-art ones. The electrodes using a 90 percent porous substrate, however, showed 17 percent higher usable specific capacity (about 0.13 Ah/g in 26 percent KOH) than that of the state-of-the-art nickel electrodes despite the low utilization. These electrodes achieved up to 4860 cycles at 40 percent depth-of-discharge with neither capacity loss nor any significant changes of rate capability and charging efficiency with cycling.

Lim, Hong S.↗

Impedance measurements on a spiral-wound nickel/metal hydride cell cycled in a simulated Leo orbit

A spiral-wound size C cell was cycled at 25 C in a low earth orbit (LEO) regime at 50 percent depth of discharge (DOD) with approximately five percent over-charge. The nominal capacity was 3.5 AH. The cell was cycled for 2000 cycles. Capacity checks and impedance measurements over the complete range of state of charge were made upon receipt and after 500, 1000, and 2000 cycles. The capacity of the cell was essentially unchanged until after the impedance measurements at 2000 cycles. Only small changes in the impedance parameters were observed, but there was somewhat more scatter in the data after 2000 cycles. When the cell was returned to LEO cycling after 2000 cycles, only 38 percent of the capacity could be obtained. It is believed that the cell failed because of an equipment failure at the end of the final impedance measurements which allowed an over-discharge.

Reid, Margaret A.↗

Nickel cadmium battery operations on-orbit: Trials, tribulations, and success on the Upper Atmosphere Research Satellite

The Upper Atmosphere Research Satellite (UARS), designed, built, integrated, tested, and operated by NASA and Martin Marietta is a low-Earth orbiting, Earth-observing spacecraft which was launched via Space Shuttle Discovery on September 12, 1991 and deployed three days later. The Modular Power Subsystem (MPS) onboard the satellite is equipped with three NASA Standard 50 Ampere-hour (Ah) nickel-cadmium (NiCd) batteries. McDonnell Douglas Electronics Systems Company fabricated the MPS, and batteries from Gates Aerospace Batteries cells. Nominal battery performance was achieved for the first four months of spacecraft operation. First evidence of anomalous battery performance was observed in January 1992, after the first maximum beta angle (low Depth of Discharge) period. Since then, the Flight Operations Team (FOT), under the direction of Goddard Space Flight Center's UARS Project and Space Power Application Branch, has monitored and managed battery performance by adjusting solar array offset angle, conducting periodic deep discharge, and controlling battery recharge ratio. This paper covers a brief overview of the UARS, the FOT's operational battery management, and the observed spacecraft battery performance.

Rao, Gopalakrishna M.↗