Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Denoising”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Characterizing Sub-Cohorts via Data Normalization and Representation Learning

The process of identifying a cohort of interest is a very challenging task. It requires manually inspecting many patient records of complex structure that might include medical coding errors and missing data. This paper presents a computational pipeline for refining the process of cohort selection based on medical concepts recorded in the electronic health records (EHRs). The pipeline extracts EHR data for a given cohort and normalizes this data using standard vocabularies. Then a stacked denoising autoencoder is used to embed the normalized patient vectors in a low dimensional space, where the patients are subsequently clustered into sub-cohorts. The goal is to represent the cohort in a standard format and abstract variants of sub-populations. As a use-case, we applied the pipeline to 1.8 million Veterans diagnosed with major depressive disorder (MDD), and identified four meaningful sub-cohorts using the features learned by the autoencoder. Then, each sub-cohort was explored using a set of keywords for interpretation.

Rush III, Everett↗

Thermomechanical Degradation of Sintered Copper Under High-Temperature Thermal Shock

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronics modules, especially in operating temperatures greater than 150 degrees C. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees C to 200 degrees C) conditions. In the fabrication phase of the samples, we used different stencil patterns and found that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality compared to a full-area print. The paste consisted of Cu microflakes, and we performed sintering using a Budatec SP300 sintering press at 275 degrees C with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained scanning electron microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS,INORGANIC, ORGANIC, PH↗

Convolutional Dictionary Regularizers for Tomographic Inversion

There has been a growing interest in the use of data-driven regularizers to solve inverse problems associated with computational imaging systems. The convolutional sparse representation model has recently gained attention, driven by the development of fast algorithms for solving the dictionary learning and sparse coding problems for sufficiently large images and data sets. Nevertheless, this model has seen very limited application to tomographic reconstruction problems. In this paper, we present a model-based tomographic reconstruction algorithm using a learnt convolutional dictionary as a regularizer. The key contribution is the use of a data-dependent weighting scheme for the l 1 regularization to construct an effective denoising method that is integrated into the inversion using the Plug-and-Play reconstruction framework. Using simulated data sets we demonstrate that our approach can improve performance over traditional regularizers based on a Markov random field model and a patch-based sparse representation model for sparse and limited-view tomographic data sets.

Singanallur Vaidyanathan, Venkatakrishnan↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

SO(3)-invariant PCA with application to molecular data

Principal component analysis (PCA) is a fundamental technique for dimensionality reduction and denoising; however, its application to three-dimensional data with arbitrary orientations -- common in structural biology -- presents significant challenges. A naive approach requires augmenting the dataset with many rotated copies of each sample, incurring prohibitive computational costs. In this paper, we extend PCA to 3D volumetric datasets with unknown orientations by developing an efficient and principled framework for SO(3)-invariant PCA that implicitly accounts for all rotations without explicit data augmentation. By exploiting underlying algebraic structure, we demonstrate that the computation involves only the square root of the total number of covariance entries, resulting in a substantial reduction in complexity. We validate the method on real-world molecular datasets, demonstrating its effectiveness and opening up new possibilities for large-scale, high-dimensional reconstruction problems.

Fraiman, Michael [Tel Aviv Univ., Tel Aviv (Israel↗

Analysis of signals under compositional noise with applications to SONAR data

In this paper, we consider the problem of denoising and classification of SONAR signals observed under compositional noise, i.e., they have been warped randomly along the x-axis. The traditional techniques do not account for such noise and, consequently, cannot provide a robust classification of signals. We apply a recent framework that: 1) uses a distance-based objective function for data alignment and noise reduction; and 2) leads to warping-invariant distances between signals for robust clustering and classification. We use this framework to introduce two distances that can be used for signal classification: a) a y-distance, which is the distance between the aligned signals; and b) an x-distance that measures the amount of warping needed to align the signals. We focus on the task of clustering and classifying objects, using acoustic spectrum (acoustic color), which is complicated by the uncertainties in aspect angles at data collections. Small changes in the aspect angles corrupt signals in a way that amounts to compositional noise. As a result, we demonstrate the use of the developed metrics in classification of acoustic color data and highlight improvements in signal classification over current methods.

47 OTHER INSTRUMENTATION↗

A Plug-and-Play Priors Approach for Solving Nonlinear Imaging Inverse Problems

In the past two decades, nonlinear image reconstruction methods have led to substantial improvements in the capabilities of numerous imaging systems. Such methods are traditionally formulated as optimization problems that are solved iteratively by simultaneously enforcing data consistency and incorporating prior models. Recently, the Plug-and-Play Priors (PPP) framework suggested that by using more sophisticated denoisers, not necessarily corresponding to an optimization objective, it is possible to improve the quality of reconstructed images. Here in this letter, we show that the PPP approach is applicable beyond linear inverse problems. In particular, we develop the fast iterative shrinkage/thresholding algorithm variant of PPP for model-based nonlinear inverse scattering. The key advantage of the proposed formulation over the original ADMM-based one is that it does not need to perform an inversion on the forward model. We show that the proposed method produces high quality images using both simulated and experimentally measured data.

97 MATHEMATICS AND COMPUTING↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Projected Multi-Agent Consensus Equilibrium (PMACE) With Application to Ptychography

Multi-Agent Consensus Equilibrium (MACE) formulates an inverse imaging problem as a balance among multiple update agents such as data-fitting terms and denoisers. However, each such agent operates on a separate copy of the full image, leading to redundant memory use and slow convergence when each agent affects only a small subset of the full image. In this article, we extend MACE to Projected Multi-Agent Consensus Equilibrium (PMACE), in which each agent updates only a projected component of the full image, thus greatly reducing memory use for some applications. We describe PMACE in terms of an equilibrium problem and an equivalent fixed-point problem and show that in most cases the PMACE equilibrium is not the solution of an optimization problem. To demonstrate the value of PMACE, we apply it to the problem of ptychography, in which a sample is reconstructed from the diffraction patterns resulting from coherent X-ray illumination at multiple overlapping spots. In our PMACE formulation, each spot corresponds to a separate data-fitting agent, with the final solution found as an equilibrium among all the agents. In conclusion, our results demonstrate that the PMACE reconstruction algorithm generates more accurate reconstructions at a lower computational cost than existing ptychography algorithms when the spots are sparsely sampled.

97 MATHEMATICS AND COMPUTING↗

Closed-Form Approximation of the Total Variation Proximal Operator

Total variation (TV) is a widely used function for regularizing imaging inverse problems that is particularly appropriate for images whose underlying structure is piecewise constant. TV regularized optimization problems are typically solved using proximal methods, but the way in which they are applied is constrained by the absence of a closed-form expression for the proximal operator of the TV function. A closed-form approximation of the TV proximal operator has previously been proposed, but its accuracy was not theoretically explored in detail. Here, we address this gap by making several new theoretical contributions, proving that the approximation leads to a proximal operator of some convex function, it is equivalent to a gradient descent step on a smoothed version of TV, and that its error can be fully characterized and controlled with its scaling parameter. We experimentally validate our theoretical results on image denoising and sparse-view computed tomography (CT) image reconstruction.

97 MATHEMATICS AND COMPUTING↗

DeepWelding: a Deep Learning Enhanced Approach to GTAW Using Multi-source Sensing Images

Deep learning has great potential to reshape manufacturing industries. In this paper, we present DeepWelding, a novel framework that applies deep learning techniques to improve gas tungsten arc welding (GTAW) process monitoring and penetration detection using multi-source sensing images. The framework is capable of analyzing multiple types of optical sensing images synchronously and consists of three deep learning enhanced consecutive phases: image preprocessing, image selection, and weld penetration classification. Specifically, we adopted generative adversarial networks (pix2pix) for image denoising and classic convolutional neural networks (AlexNet) for image selection. Both pix2pix and AlexNet delivered satisfactory performance. However, five individual neural networks with heterogeneous architectures demonstrated inconsistent generalization capabilities in the classification phase when holding out multi-source images generated with specific experimental settings. Therefore, two ensemble methods combining multiple neural networks were designed to improve the model performance on unseen data collected from different experimental settings. In conclusion, we also found that the quality of model prediction was heavily influenced by the data stream collection environment. We think these findings are beneficial for the broad intelligent welding community.

42 ENGINEERING↗

Comparative analysis of nonlinear dimensionality reduction techniques for breast MRI segmentation

Purpose: Visualization of anatomical structures using radiological imaging methods is an important tool in medicine to differentiate normal from pathological tissue and can generate large amounts of data for a radiologist to read. Integrating these large data sets is difficult and time-consuming. A new approach uses both supervised and unsupervised advanced machine learning techniques to visualize and segment radiological data. This study describes the application of a novel hybrid scheme, based on combining wavelet transform and nonlinear dimensionality reduction (NLDR) methods, to breast magnetic resonance imaging (MRI) data using three well-established NLDR techniques, namely, ISOMAP, local linear embedding (LLE), and diffusion maps (DfM), to perform a comparative performance analysis. Methods: Twenty-five breast lesion subjects were scanned using a 3T scanner. MRI sequences used were T1-weighted, T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging. The hybrid scheme consisted of two steps: preprocessing and postprocessing of the data. The preprocessing step was applied for B{sub 1} inhomogeneity correction, image registration, and wavelet-based image compression to match and denoise the data. In the postprocessing step, MRI parameters were considered data dimensions and the NLDR-based hybrid approach was applied to integrate the MRI parameters into a single image, termed the embedded image. This was achieved by mapping all pixel intensities from the higher dimension to a lower dimensional (embedded) space. For validation, the authors compared the hybrid NLDR with linear methods of principal component analysis (PCA) and multidimensional scaling (MDS) using synthetic data. For the clinical application, the authors used breast MRI data, comparison was performed using the postcontrast DCE MRI image and evaluating the congruence of the segmented lesions. Results: The NLDR-based hybrid approach was able to define and segment both synthetic and clinical data. In the synthetic data, the authors demonstrated the performance of the NLDR method compared with conventional linear DR methods. The NLDR approach enabled successful segmentation of the structures, whereas, in most cases, PCA and MDS failed. The NLDR approach was able to segment different breast tissue types with a high accuracy and the embedded image of the breast MRI data demonstrated fuzzy boundaries between the different types of breast tissue, i.e., fatty, glandular, and tissue with lesions (>86%). Conclusions: The proposed hybrid NLDR methods were able to segment clinical breast data with a high accuracy and construct an embedded image that visualized the contribution of different radiological parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Algorithmic scatter correction in dual-energy digital mammography

Purpose: Small calcifications are often the earliest and the main indicator of breast cancer. Dual-energy digital mammography (DEDM) has been considered as a promising technique to improve the detectability of calcifications since it can be used to suppress the contrast between adipose and glandular tissues of the breast. X-ray scatter leads to erroneous calculations of the DEDM image. Although the pinhole-array interpolation method can estimate scattered radiations, it requires extra exposures to measure the scatter and apply the correction. The purpose of this work is to design an algorithmic method for scatter correction in DEDM without extra exposures.Methods: In this paper, a scatter correction method for DEDM was developed based on the knowledge that scattered radiation has small spatial variation and that the majority of pixels in a mammogram are noncalcification pixels. The scatter fraction was estimated in the DEDM calculation and the measured scatter fraction was used to remove scatter from the image. The scatter correction method was implemented on a commercial full-field digital mammography system with breast tissue equivalent phantom and calcification phantom. The authors also implemented the pinhole-array interpolation scatter correction method on the system. Phantom results for both methods are presented and discussed. The authors compared the background DE calcification signals and the contrast-to-noise ratio (CNR) of calcifications in the three DE calcification images: image without scatter correction, image with scatter correction using pinhole-array interpolation method, and image with scatter correction using the authors' algorithmic method.Results: The authors' results show that the resultant background DE calcification signal can be reduced. The root-mean-square of background DE calcification signal of 1962 μm with scatter-uncorrected data was reduced to 194 μm after scatter correction using the authors' algorithmic method. The range of background DE calcification signals using scatter-uncorrected data was reduced by 58% with scatter-corrected data by algorithmic method. With the scatter-correction algorithm and denoising, the minimum visible calcification size can be reduced from 380 to 280 μm.Conclusions: When applying the proposed algorithmic scatter correction to images, the resultant background DE calcification signals can be reduced and the CNR of calcifications can be improved. This method has similar or even better performance than pinhole-array interpolation method in scatter correction for DEDM; moreover, this method is convenient and requires no extra exposure to the patient. Although the proposed scatter correction method is effective, it is validated by a 5-cm-thick phantom with calcifications and homogeneous background. The method should be tested on structured backgrounds to more accurately gauge effectiveness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-18C-13: Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method

Purpose: To develop a novel reconstruction method for X-ray CT that can lead to accurate reconstruction at significantly reduced dose levels combining low X-ray incident intensity and few views of projection data. Methods: The noise nature of the projection data at low X-ray incident intensity was modeled and accounted by the weighted least-squares (WLS) criterion. The total variation (TV) penalty was used to mitigate artifacts caused by few views of data. The first order primal-dual (FOPD) algorithm was used to minimize TV in image domain, which avoided the difficulty of the non-smooth objective function. The TV penalized WLS reconstruction was achieved by alternated FOPD TV minimization and projection onto convex sets (POCS) for data fidelity constraints. The proposed FOPD-POCS method was evaluated using the FORBILD jaw phantom and the real cadaver head CT data. Results: The quantitative measures, root mean square error (RMSE) and contrast-to-noise ratio (CNR), demonstrate the superior denoising capability of WLS over LS-based TV iterative reconstruction. The improvement of RMSE (WLS vs. LS) is 15%∼21% and that of CNR is 17%∼72% when the incident counts per ray are ranged from 1×10{sup 5} to 1×10{sup 3}. In addition, the TV regularization can accurately reconstruct images from about 50 views of the jaw phantom. The FOPD-POCS reconstruction reveals more structural details and suffers fewer artifacts in both the phantom and real head images. The FOPD-POCS method also shows fast convergence at low X-ray incident intensity. Conclusion: The new hybrid FOPD-POCS method, based on TV penalized WLS, yields excellent image quality when the incident X-ray intensity is low and the projection views are limited. The reconstruction is computationally efficient since the FOPD minimization of TV is applied only in the image domain. The characteristics of FOPD-POCS can be exploited to significantly reduce radiation dose of X-ray CT without compromising accuracy for diagnosis or treatment planning.

60 APPLIED LIFE SCIENCES↗

WE-D-9A-04: Improving Multi-Modality Image Registration Using Edge-Based Transformations

Purpose: Multi-modality deformable image registration (DIR) for head and neck (HN) radiotherapy is difficult, particularly when matching computed tomography (CT) scans with magnetic resonance imaging (MRI) scans. We hypothesized that the ‘shared information’ between images of different modalities was to be found in some form of edge-based transformation, and that novel edge-based DIR methods might outperform standard DIR methods. Methods: We propose a novel method that combines gray-scale edge-based morphology and mutual information (MI) in two stages. In the first step, we applied a modification of a previously published mathematical morphology method as an efficient gray scale edge estimator, with denoising function. The results were fed into a MI-based solver (plastimatch). The method was tested on 5 HN patients with pretreatment CT and MR datasets and associated follow-up weekly MR scans. The followup MRs showed significant regression in tumor and normal structure volumes as compared to the pretreatment MRs. The MR images used in this study were obtained using fast spin echo based T2w images with a 1 mm isotropic resolution and FOV matching the CT scan. Results: In all cases, the novel edge-based registration method provided better registration quality than MI-based DIR using the original CT and MRI images. For example, the mismatch in carotid arteries was reduced from 3–5 mm to within 2 mm. The novel edge-based method with different registration regulation parameters did not show any distorted deformations as compared to the non-realistic deformations resulting from MI on the original images. Processing time was 1.3 to 2 times shorter (edge vs. non-edge). In general, we observed quality improvement and significant calculation time reduction with the new method. Conclusion: Transforming images to an ‘edge-space,’ if designed appropriately, greatly increases the speed and accuracy of DIR.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections; 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)

60 APPLIED LIFE SCIENCES↗

SU-C-207-05: A Comparative Study of Noise-Reduction Algorithms for Low-Dose Cone-Beam Computed Tomography

Purpose: To study different noise-reduction algorithms and to improve the image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low-dose cone-beam CT, the reconstructed image is contaminated with excessive quantum noise. In this study, three well-developed noise reduction algorithms namely, a) penalized weighted least square (PWLS) method, b) split-Bregman total variation (TV) method, and c) compressed sensing (CS) method were studied and applied to the images of a computer–simulated “Shepp-Logan” phantom and a physical CATPHAN phantom. Up to 20% additive Gaussian noise was added to the Shepp-Logan phantom. The CATPHAN phantom was scanned by a Varian OBI system with 100 kVp, 4 ms and 20 mA. For comparing the performance of these algorithms, peak signal-to-noise ratio (PSNR) of the denoised images was computed. Results: The algorithms were shown to have the potential in reducing the noise level for low-dose CBCT images. For Shepp-Logan phantom, an improvement of PSNR of 2 dB, 3.1 dB and 4 dB was observed using PWLS, TV and CS respectively, while for CATPHAN, the improvement was 1.2 dB, 1.8 dB and 2.1 dB, respectively. Conclusion: Penalized weighted least square, total variation and compressed sensing methods were studied and compared for reducing the noise on a simulated phantom and a physical phantom scanned by low-dose CBCT. The techniques have shown promising results for noise reduction in terms of PSNR improvement. However, reducing the noise without compromising the smoothness and resolution of the image needs more extensive research.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-03: Using Edge-Preserving Algorithm for Significantly Improved Image-Domain Material Decomposition in Dual Energy CT

Purpose: To significantly improve dual energy CT (DECT) imaging by establishing a new theoretical framework of image-domain material decomposition with incorporation of edge-preserving techniques. Methods: The proposed algorithm, HYPR-NLM, combines the edge-preserving non-local mean filter (NLM) with the HYPR-LR (Local HighlY constrained backPRojection Reconstruction) framework. Image denoising using HYPR-LR framework depends on the noise level of the composite image which is the average of the different energy images. For DECT, the composite image is the average of high- and low-energy images. To further reduce noise, one may want to increase the window size of the filter of the HYPR-LR, leading resolution degradation. By incorporating the NLM filtering and the HYPR-LR framework, HYPR-NLM reduces the boost material decomposition noise using energy information redundancies as well as the non-local mean. We demonstrate the noise reduction and resolution preservation of the algorithm with both iodine concentration numerical phantom and clinical patient data by comparing the HYPR-NLM algorithm to the direct matrix inversion, HYPR-LR and iterative image-domain material decomposition (Iter-DECT). Results: The results show iterative material decomposition method reduces noise to the lowest level and provides improved DECT images. HYPR-NLM significantly reduces noise while preserving the accuracy of quantitative measurement and resolution. For the iodine concentration numerical phantom, the averaged noise levels are about 2.0, 0.7, 0.2 and 0.4 for direct inversion, HYPR-LR, Iter- DECT and HYPR-NLM, respectively. For the patient data, the noise levels of the water images are about 0.36, 0.16, 0.12 and 0.13 for direct inversion, HYPR-LR, Iter-DECT and HYPR-NLM, respectively. Difference images of both HYPR-LR and Iter-DECT show edge effect, while no significant edge effect is shown for HYPR-NLM, suggesting spatial resolution is well preserved for HYPR-NLM. Conclusion: HYPR-NLM provides an effective way to reduce the generic magnified image noise of dual–energy material decomposition while preserving resolution. This work is supported in part by NIH grants 7R01HL111141 and 1R01-EB016777. This work is also supported by the Natural Science Foundation of China (NSFC Grant No. 81201091), Fundamental Research Funds for the Central Universities in China, and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.

60 APPLIED LIFE SCIENCES↗