Evaluation of waveguide coating materials

Waveguide coating materials were tested at 8470 MHz for insertion loss. Samples of these coatings on waveguide pieces without flanges were tested in an environmental chamber to simulate the effects of high power microwave heating. Test results indicated that three types of coating materials are acceptable with regard to insertion loss. However, simulated microwave heating caused debonding of Metcot 7 and BD-991 coatings, resulting in peelings in the waveguide. The higher cost Chemglaze R104 does not exhibit this problem.

Chen, W. C. J.↗

A note on the cracked plates reinforced by a line stiffener

The problem of a cracked plate reinforced by a line stiffener is reconsidered. The original solution of this problem was given in the literature. Also, a variation of the problem with debonding between the plate and the stiffener near the cracked region was reported in the literature. However, the special case of the problem in which the crack tip terminates at the stiffener does not appear to have been studied. In practice, the solution may be necessary in order to assess the crack arrest effectiveness of the stiffener. The problem of a stiffened plate with a crack is reformulated, the asymptotic stress state near the crack tip terminating at the stiffener is examined, and numerical results are given for various stiffness constants.

Yahsi, O. S.↗

Fatigue behavior of adhesively bonded joints

The fatigue damage mechanism of composite to composite adhesively bonded joints was characterized. The mechanics of the possible modes of fatigue damage propagation in these joints when subjected to constant amplitude cyclic mechanical loading were investigated. The possible failure modes in composite bonded joints may be cyclic debonding (i.e., progressive separation of the adhesive), interlaminar damage (delamination), adherend fatigue or a combination of these. Two composite systems - graphite/epoxy adhesively bonded to graphite/epoxy and Kevlar 49/epoxy adhesively bonded to Kevlar 49/epoxy were investigated. Both composite systems consisted of quasi-isotropic lay-ups, i.e., 0 deg/-45 deg/+45 deg/90 degs. The two adhesives, employed in the study were (1) EC 3445 with cure temperature of 250 F for secondary bonding and (2) FM 300 with cure temperature of 350 F for co-cure bonding.

Mall, S.↗

A note on the cracked plates reinforced by a line stiffener

The problem of a cracked plate reinforced by a line stiffener is reconsidered. The original solution of this problem was given in the literature. Also, a variation of the problem with debonding between the plate and the stiffener near the cracked region was reported in the literature. However, the special case of the problem in which the crack tip terminates at the stiffener does not appear to have been studied. In practice, the solution may be necessary in order to assess the crack arrest effectiveness of the stiffener. The problem of a stiffened plate with a crack is reformulated, the asymptotic stress state near the crack tip terminating at the stiffener is examined, and numerical results are given for various stiffness constants. Previously announced in STAR as N83-21388

Yahsi, O. S.↗

Residual strength assessment of low velocity impact damage of graphite-epoxy laminates

This report contains the study of Low Velocity Transverse Impact Damage of graphite-epoxy T300/5208 composite laminates. The specimen, 100 mm diameter clamped plates, were impact damaged by a cantilever-type instrumented 1-inch diameter steel ball. Study was limited to impact velocity 6 m/sec. Rectangular strips, 50 mm x 125 mm, were cut from the impact-damage specimens so that the impact damage zone was in the center of the strips. These strips were tested in tension to obtain their residual strength. An energy dissipation model was developed to predict the residual strength from fracture mechanics concepts. Net energy absorbed I(a) was evaluated from coefficient of restitution concepts based on shear dominated theory of fiber-reinforced materials, with the modification that during loading and unloading the shear deformation are respectively elastic-plastic and elastic. Delamination energy I(d) was predicted by assuming that the stiffness of the laminate dropped due to debonding. Fiber-breakage energy, assumed to be equal to the difference of I(a) and I(d), was used to determine the residual strength. Predictions were compared with test results.

Lal, K. M.↗

Thermal degradation of the tensile properties of undirectionally reinforced FP-Al2O3/EZ 33 magnesium composites

The effects of isothermal and cyclic exposure on the room temperature axial and transverse tensile strength and dynamic flexural modulus of 35 volume percent and 55 volume percent FP-Al203/EZ 33 magnesium composites were studied. The composite specimens were continuously heated in a sand bath maintained at 350 C for up to 150 hours or thermally cycled between 50 and 250 C or 50 and 350 C for up to 3000 cycles. Each thermal cycle lasted for a total of six minutes with a hold time of two minutes at the maximum temperature. Results indicate no significant loss in the room temperature axial tensile strength and dynamic flexural modulus of composites thermally cycled between 50 and 250 C or of composites isothermally heated at 350 C for up to 150 hours from the strength and modulus data for the untreated, as-fabricated composites. In contrast, thermal cycling between 50 and 350 C caused considerable loss in both room temperature strength and modulus. Fractographic analysis and measurement of composite transverse strength and matrix hardness of thermally cycled and isothermally heated composites indicated matrix softening and fiber/matrix debonding due to void growth at the interface and matrix cracking as the likely causes of the strength and modulus loss behavior. Previously announced in STAR as N82-21260

Bhatt, R.T.↗

Spring-Loaded Transducer Holder

Portable ultrasonic scanner moves transducer at constant pressure. Spring-loaded holder moves ultrasonic transducer over test sample at constant pressure. Setup used to determine rate of debond taking place in glued materials subjected to fatigue loading. Holder designed as portable field unit adapted to fatigue machine that transmits data while specimen tested.

Gardner, M. R.↗

Perforating Thin Metal Sheets

Sheets only few mils thick bonded together, punched, then debonded. Three-step process yields perforated sheets of metal. (1): Individual sheets bonded together to form laminate. (2): laminate perforated in desired geometric pattern. (3): After baking, laminate separates into individual sheets. Developed for fabricating conductive layer on blankets that collect and remove ions; however, perforated foils have other applications - as conductive surfaces on insulating materials; stiffeners and conductors in plastic laminates; reflectors in antenna dishes; supports for thermal blankets; lightweight grille cover materials; and material for mockup of components.

Davidson, M. E.↗

Geometric and Material Nonlinear Structural Analysis

GAMNAS (Geometric and Material Nonlinear Analysis of Structures) is twodimensional finite-element stress-analysis program supporting fracturemechanics studies of debonding and delamination. GAMNAS options include linear, geometricnonlinear, material-nonlinear, and combined geometric- and material-nonlinear analysis.

Whitcomb, J. D.↗

Insulation bonding test system

A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.

Beggs, J. M.↗

Delamination micromechanics analysis

A three-dimensional finite element analysis was developed which includes elastoplastic, orthotropic material response, and fracture initiation and propagation. Energy absorption due to physical failure processes characteristic of the heterogeneous and anisotropic nature of composite materials is modeled. A local energy release rate in the presence of plasticity was defined and used as a criterion to predict the onset and growth of cracks in both micromechanics and macromechanics analyses. This crack growth simulation technique is based upon a virtual crack extension method. A three-dimensional finite element micromechanics model is used to study the effects of broken fibers, cracked matrix and fiber-matrix debond on the fracture toughness of the unidirectional composite. The energy release rates at the onset of unstable crack growth in the micromechanics analyses are used as critical energy release rates in the macromechanics analysis. This integrated micromechanical and macromechanical fracture criterion is shown to be very effective in predicting the onset and growth of cracks in general multilayered composite laminates by applying the criterion to a single-edge notched graphite/epoxy laminate subjected to implane tension normal to the notch.

Adams, D. F.↗

Effect of additional heat treatment of 2024-T3 on the growth of fatigue crack in air and in vacuum

In order to determine the influence of ductility on the fatigue crack growth rate of aluminum alloys, fatigue tests were carried out on central notched specimens of 2024-T3 and 2024-T8 sheet material. The 2024-T8 material was obtained by an additional heat treatment applied on 2024-T3 (18 hours at 192 C), which increased the static yield strength from 43.6 to 48.9 kgf/sq mm. A change in the ultimate strength was not observed. Fatigue tests were carried out on both materials in humid air and in high vacuum. According to a new crack propagation model, crack extension is supported to be caused by a slip-related process and debonding triggered by the environment. This model predicts an effect of the ductility on the crack growth rate which should be smaller in vacuum than in humid air; however, this was not confirmed. In humid air the crack-growth rate in 2024-T8 was about 2 times faster than in 2024-T3, while in vacuum the ratio was about 2.5. Crack closure measurements gave no indications that crack closure played a significant role in both materials. Some speculative explanations are briefly discussed.

Louwaard, E. P.↗

Compression failure mechanisms of composite structures

An experimental and analytical study was conducted to delineate the compression failure mechanisms of composite structures. The present report summarizes further results on kink band formation in unidirectional composites. In order to assess the compressive strengths and failure modes of fibers them selves, a fiber bundle was embedded in epoxy casting and tested in compression. A total of six different fibers were used together with two resins of different stiffnesses. The failure of highly anisotropic fibers such as Kevlar 49 and P-75 graphite was due to kinking of fibrils. However, the remaining fibers--T300 and T700 graphite, E-glass, and alumina--failed by localized microbuckling. Compressive strengths of the latter group of fibers were not fully utilized in their respective composite. In addition, acoustic emission monitoring revealed that fiber-matrix debonding did not occur gradually but suddenly at final failure. The kink band formation in unidirectional composites under compression was studied analytically and through microscopy. The material combinations selected include seven graphite/epoxy composites, two graphite/thermoplastic resin composites, one Kevlar 49/epoxy composite and one S-glass/epoxy composite.

Hahn, H. T.↗

Criterion for mixed mode fracture in composite bonded joints

A study was undertaken to characterize the debond growth mechanism of adhesively bonded composite joints under mode I, mixed mode I-II, and mode II static loadings. The bonded system consisted of graphite-epoxy composite adherends bonded with a toughened epoxy adhesive. The mode I, mode II and mixed mode I-II fracture energies of the tested adhesives were found to be equal to each other. The criterion for mixed mode fracture in composite bonded joints was found.

Mall, S.↗

Longitudinal compressive failure modes in fiber composites End attachment effects on IITRI type test specimens

The end-attachment effects on longitudinal compressive strength of IITRI type specimen unidirectional fiber composites are formally assessed using finite-element analysis (FEA) in conjunction with composite mechanics. Sixteen different cases were analyzed to evaluate end-attachment effects (such as degree of misalignment, type of misalignment, progressive end-tab debonding, and specimen thickness) on stress distribution, peak stresses, buckling loads, and buckling mode shapes. The results obtained from the FEA and comparisons with fractured specimens show that eccentricities induce bending-type stresses which peak near the end-tabs and cause flexural type fracture. Also, guidelines are included for placing back-to-back strain gages to measure the presence/absence of possible end-attachment and eccentricity effects.

Chamis, C. C.↗

Mode 1 delamination growth in adhesively bonded joints under static and fatigue loads

The objective of this investigation was to characterize the pure mode 1 delamination growth in metal to metal adhesively bonded joints under static and fatigue loading conditions, using FM 73 adhesive. Double cantilever beam specimens (DCB) were used for pure mode 1 tests. Aluminum 2024-T3 adherends were bonded with FM 73 adhesive. Delamination was introduced during fabrication by inserting a Teflon film between the two adherends. The mode 1 strain energy release rate G sub I sub c was obtained directly from static DCB tests conducted in accordance with the ASTM designation D1876-12. Constant amplitude fatigue tests on DCB specimens were conducted to determine the relationship between delamination growth rate da/dN and strain energy release rate G sub I sub c for a pure mode 1 delamination growth. It is found that the debond propagation rate in adhesive joints using FM 73 is more sensitive to errors in design load than is typical crack growth rate in metallic structures.

Biswas, S. C.↗

Fracture and crack growth in orthotropic laminates

A mathematical model based on the classical shear-lag assumptions is used to study the residual strength and fracture behavior of composite laminates with symmetrically placed buffer strips. The laminate is loaded by a uniform remote longitudinal tensile strain and has initial damage in the form of a transverse crack in the parent laminate between buffer strips. The crack growth behavior as a function of material properties, number of buffer-strip plies, spacing, width of buffer strips, longitudinal matrix splitting, and debonding at the interface is studied. Buffer-strip laminates are shown to arrest fracture and increase the residual strengths significantly over those of one material laminates, with S-glass being a more effective buffer strip material than Kevlar in increasing the damage tolerance of graphite/epoxy panels. For a typical graphite/epoxy laminate with S-glass buffer-strips, the residual strength is about 2.4 times the residual strength of an all graphite/epoxy panel with the same crack length. Approximately 50% of this increase is due to the S-glass/epoxy buffer-strips, 40% due to longitudinal splitting of the buffer strip interface and 10% due to bonding.

Goree, James G.↗

Criterion for mixed mode fracture in composite bonded joints

A study was undertaken to characterize the debond growth mechanism of adhesively bonded composite joints under mode I, mixed mode I-II, and mode II static loadings. The bonded system consisted of graphite/epoxy (T300/5208) composite adherends bonded with a toughened epoxy (EC 3445) adhesive. The mode I, mode II and mixed-mode I-II fracture energies of the tested adhesive were found to be equal to each other. Furthermore, the criterion for mixed mode fracture in composite bonded joints was determined.