Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data compression (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-E-J-172: A Quantitative Assessment of Lung Tumor Motion Using 4DCT Imaging Under Conditions of Controlled Breathing in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiation Therapy (SBRT)

Purpose: To study breathing related tumor motion amplitudes by lung lobe location under controlled breathing conditions used in Stereotactic Body Radiation Therapy (SBRT) for NSCLC. Methods: Sixty-five NSCLC SBRT patients since 2009 were investigated. Patients were categorized based on tumor anatomic location (RUL-17, RML-7, RLL-18, LUL-14, LLL-9). A 16-slice CT scanner [GE RT16 Pro] along with Varian Realtime Position Management (RPM) software was used to acquire the 4DCT data set using 1.25 mm slice width. Images were binned in 10 phases, T00 being at maximum inspiration ' T50 at maximum expiration phase. Tumor volume was segmented in T50 using the CT-lung window and its displacement were measured from phase to phase in all three axes; superiorinferior, anterior-posterior ' medial-lateral at the centroid level of the tumor. Results: The median tumor movement in each lobe was as follows: RUL= 3.8±2.0 mm (mean ITV: 9.5 cm{sup 3}), RML= 4.7±2.8 mm (mean ITV: 9.2 cm{sup 3}), RLL=6.6±2.6 mm (mean ITV: 12.3 cm{sup 3}), LUL=3.8±2.4 mm (mean ITV: 18.5 cm{sup 3}), ' LLL=4.7±2.5 mm (mean ITV: 11.9 cm{sup 3}). The median respiratory cycle for all patients was found to be 3.81 ± 1.08 seconds [minimum 2.50 seconds, maximum 7.07 seconds]. The tumor mobility incorporating breathing cycle was RUL = 0.95±0.49 mm/s, RML = 1.35±0.62 mm/s, RLL = 1.83±0.71 mm/s, LUL = 0.98 ±0.50 mm/s, and LLL = 1.15 ±0.53 mm/s. Conclusion: Our results show that tumor displacement is location dependent. The range of motion and mobility increases as the location of the tumor nears the diaphragm. Under abdominal compression, the magnitude of tumor motion is reduced by as much as a factor of 2 in comparison to reported tumor magnitudes under conventional free breathing conditions. This study demonstrates the utility of abdominal compression in reducing the tumor motion leading to reduced ITV and planning tumor volumes (PTV)

60 APPLIED LIFE SCIENCES↗

Shock-Induced Solid-State Reactions in Powders: An Experimentally-Based Reassessment

We have performed a series of ten planar impact experiments on six different materials, including certain reactive powders and two inert materials, using Sandia's 89 - mm powder gun at the STAR facility. Time - resolved particle - velocity histories were determined during each of the experiments from one or more VISAR measurements. We have analyzed the results of these measurements 1) by using jump conditions to determine shock and first reshock states and 2) by comparing measured particle velocity histories to synthetic histories predicted by one - dimensional computational analyses using the CTH shock physics code with various models for inert and reactive materials . These comparisons are consistent with the conclusion for these particular reactive powders, that for the duration of shock loading either 1) there is insignificant reaction or 2) the products of any reaction are indistinguishable from the reactants under the experimental conditions. Shock and reshock states were extracted for shock pressures between 5 and 40 GPa. Densities were at or greater than the theoretical maximum zero - pressure density of the starting mixture. This result would be expected if there were no reaction or negligible reaction for the first two shock states. Two experiments were performed on one reactive powder in a "ring - down " geometry to look for evidence of vapor production on pressure release. In both cases, the measured velocity continued to increase slowly over a period of microseconds for the du ration of the experiment. This observation suggests that vapor is produced along the release path, but information about the mechanism for vapor production cannot be extracted from these data. While it is possible that vapor is produced by a shock - induced reaction involving more than one of the original constituents, a simpler interpretation is that the vapor is made up of products of shock - induced decomposition reactions and/or simple vaporization of the constituents as would be expected to take place under the conditions of these experiments. Other sources of vapor could be water adsorbed on grain surfaces and air originally in the voids. Thus it is not necessary to invoke significant recombination reactions to explain the data. However, in the absence of ring - down control experiments, the possibility remains open. These conclusions are different from those of previous workers, but reassessment of a subset of the earlier data yields results consistent with the present work, i.e., the shock compression data do not provide evidence for strong exothermic reactions.

36 MATERIALS SCIENCE↗

Universal method for the optimization of HDC coating uniformity on non-planar, non-stationary substrates for inertial confinement fusion targets

The thickness uniformity of chemical vapor deposited (CVD) diamond coatings on non-planar, non-stationary substrates depends on both the intrinsic instantaneous coating thickness distribution (ICTD) of the coating conditions used and, if applicable, on the frequency of substrate reorientation. While important for many CVD diamond applications, the relative impact of the ICTD and substrate reorientation on the coating thickness uniformity has not been studied. In this work, we systematically investigate the effect of these factors for microwave-plasma chemical vapor deposition (MPCVD) of diamond (referred to as high density carbon (HDC) in the inertial confinement fusion (ICF) community) coatings on spherical, rolling substrates. This coating technique is used to fabricate capsules for ICF experiments, which require extreme coating uniformity with <0.3 % thickness variation (so-called Mode 1 or M1) to ensure symmetric compression of imploding targets. To extract the otherwise unobservable reorientation timescale (Δt), Monte Carlo simulations were performed using experimental ICTD data as input. This combined approach confirms scaling relationships between the substrate reorientation timescale as well as coating thickness and coating uniformity, as expected from a 3D random walk. Simulations confirm that M1 is Rayleigh-distributed and scales as (Δt) 1/2 , consistent with the randomization of two angles that determine orientation of a sphere. We also demonstrate that, under the conditions studied, Δt is the dominant factor in determining thickness uniformity while the intrinsic ICTD has minimal impact. Finally, experiments show that Δt can be affected by total batch size under constant agitation conditions due to space constraints that limit the capsule reorientation kinetics. In conclusion, this study highlights the utility of a combined experiment-simulation approach as a general methodology for understanding and improving coating uniformity on non-planar, non-stationary substrates.

Capsule↗

SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol

Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoring function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-15: Sliding Window Prior Data Assisted Compressed Sensing for MRI Lung Tumor Tracking

Purpose: Prior Data Assisted Compressed Sensing (PDACS) is a partial k-space acquisition and reconstruction method for mobile tumour (i.e. lung) tracking using on-line MRI in radiotherapy. PDACS partially relies on prior data acquired at the beginning of dynamic scans, and is therefore susceptible to artifacts in longer duration scan due to slow drifts in MR signal. A novel sliding window strategy is presented to mitigate this effect. Methods: MRI acceleration is simulated by retrospective removal of data from the fully sampled sets. Six lung cancer patients were scanned (clinical 3T MRI) using a balanced steady state free precession (bSSFP) sequence for 3 minutes at approximately 4 frames per second, for a total of 650 dynamics. PDACS acceleration is achieved by undersampling of k-space in a single pseudo-random pattern. Reconstruction iteratively minimizes the total variations while constraining the images to satisfy both the currently acquired data and the prior data in missing k-space. Our novel sliding window technique (SW-PDACS), uses a series of distinct pseudo-random under-sampling patterns of partial k-space – with the prior data drawn from a sliding window of the most recent data available. Under-sampled data, simulating 2 – 5x acceleration are reconstructed using PDACS and SW-PDACS. Three quantitative metrics: artifact power, centroid error and Dice’s coefficient are computed for comparison. Results: Quantitively metric values from all 6 patients are averaged in 3 bins, each containing approximately one minute of dynamic data. For the first minute bin, PDACS and SW-PDACS give comparable results. Progressive decline in image quality metrics in bins 2 and 3 are observed for PDACS. No decline in image quality is observed for SW-PDACS. Conclusion: The novel approach presented (SW-PDACS) is a more robust for accelerating longer duration (>1 minute) dynamic MRI scans for tracking lung tumour motion using on-line MRI in radiotherapy. B.G. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifacts these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.

60 APPLIED LIFE SCIENCES↗

Automated registration of diagnostic to prediagnostic x-ray mammograms: Evaluation and comparison to radiologists' accuracy

Purpose: To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. Methods: X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter configurations of three registration methods, affine, fluid, and free-form deformation (FFD), were optimized for registering x-ray mammograms on these simulated images. Five mammography film readers independently identified landmarks (tumor, nipple, and usually two other normal features) on pairs of diagnostic and corresponding prediagnostic digitized images from 52 breast cancer cases. Landmarks were independently reidentified by each reader. Target registration errors were calculated to compare the three registration methods using the reader landmarks as a gold standard. Data were analyzed using multilevel methods. Results: Between-reader variability varied with landmark (p<0.01) and screen (p=0.03), with between-reader mean distance (mm) in point location on the diagnostic/prediagnostic images of 2.50 (95% CI 1.95, 3.15)/2.84 (2.24, 3.55) for nipples and 4.26 (3.43, 5.24)/4.76 (3.85, 5.84) for tumors. Registration accuracy was sensitive to the type of landmark and the amount of breast density. For dense breasts ({>=}40%), the affine and fluid methods outperformed FFD. For breasts with lower density, the affine registration surpassed both fluid and FFD. Mean accuracy (mm) of the affine registration varied between 3.16 (95% CI 2.56, 3.90) for nipple points in breasts with density 20%-39% and 5.73 (4.80, 6.84) for tumor points in breasts with density <20%. Conclusions: Affine registration accuracy was comparable to that between independent film readers. More advanced two-dimensional nonrigid registration algorithms were incapable of increasing the accuracy of image alignment when compared to affine registration.

60 APPLIED LIFE SCIENCES↗

Direct imaging of shock wave splitting in diamond at Mbar pressure

Understanding the behavior of matter at extreme pressures of the order of a megabar (Mbar) is essential to gain insight into various physical phenomena at macroscales—the formation of planets, young stars, and the cores of super-Earths, and at microscales—damage to ceramic materials and high-pressure plastic transformation and phase transitions in solids. Under dynamic compression of solids up to Mbar pressures, even a solid with high strength exhibits plastic properties, causing the induced shock wave to split in two: an elastic precursor and a plastic shock wave. This phenomenon is described by theoretical models based on indirect measurements of material response. The advent of x-ray free-electron lasers (XFELs) has made it possible to use their ultrashort pulses for direct observations of the propagation of shock waves in solid materials by the method of phase-contrast radiography. However, there is still a lack of comprehensive data for verification of theoretical models of different solids. Here, we present the results of an experiment in which the evolution of the coupled elastic–plastic wave structure in diamond was directly observed and studied with submicrometer spatial resolution, using the unique capabilities of the x-ray free-electron laser (XFEL). The direct measurements allowed, for the first time, the fitting and validation of the 2D failure model for diamond in the range of several Mbar. Our experimental approach opens new possibilities for the direct verification and construction of equations of state of matter in the ultra-high-stress range, which are relevant to solving a variety of problems in high-energy-density physics.

36 MATERIALS SCIENCE↗

Search for supersymmetry using vector boson fusion signatures and missing transverse momentum in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

This paper presents a search for supersymmetric particles in models with highly compressed mass spectra, in events consistent with being produced through vector boson fusion. The search uses 140 fb −1 of proton-proton collision data at $\sqrt{s}$ = 13 TeV collected by the ATLAS experiment at the Large Hadron Collider. Events containing at least two jets with a large gap in pseudorapidity, large missing transverse momentum, and no reconstructed leptons are selected. A boosted decision tree is used to separate events consistent with the production of supersymmetric particles from those due to Standard Model backgrounds. The data are found to be consistent with Standard Model predictions. The results are interpreted using simplified models of R-parity-conserving supersymmetry in which the lightest supersymmetric partner is a bino-like neutralino with a mass similar to that of the lightest chargino and second-to-lightest neutralino, both of which are wino-like. Lower limits at 95% confidence level on the masses of next-to-lightest supersymmetric partners in this simplified model are established between 117 and 120 GeV when the lightest supersymmetric partners are within 1 GeV in mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Athena Microscopic Imager Investigation

The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI) [1]. The MI is a fixed-focus camera mounted on the end of an extendable instrument arm, the Instrument Deployment Device (IDD; see Figure 1).The MI was designed to acquire images at a spatial resolution of 30 microns/pixel over a broad spectral range (400 - 700 nm; see Table 1). Technically, the microscopic imager is not a microscope: it has a fixed magnification of 0.4 and is intended to produce images that simulate a geologist s view through a common hand lens. In photographers parlance, the system makes use of a macro lens. The MI uses the same electronics design as the other MER cameras [2, 3] but has optics that yield a field of view of 31 31 mm across a 1024 1024 pixel CCD image (Figure 2). The MI acquires images using only solar or skylightillumination of the target surface. A contact sensor is used to place the MI slightly closer to the target surface than its best focus distance (about 66 mm), allowing concave surfaces to be imaged in good focus. Because the MI has a relatively small depth of field (3 mm), a single MI image of a rough surface will contain both focused and unfocused areas. Coarse focusing will be achieved by moving the IDD away from a rock target after the contact sensor is activated. Multiple images taken at various distances will be acquired to ensure good focus on all parts of rough surfaces. By combining a set of images acquired in this way, a completely focused image can be assembled. Stereoscopic observations can be obtained by moving the MI laterally relative to its boresight. Estimates of the position and orientation of the MI for each acquired image will be stored in the rover computer and returned to Earth with the image data. The MI optics will be protected from the Martian environment by a retractable dust cover. The dust cover includes a Kapton window that is tinted orange to restrict the spectral bandpass to 500-700 nm, allowing color information to be obtained by taking images with the dust cover open and closed. The MI will image the same materials measured by other Athena instruments (including surfaces prepared by the Rock Abrasion Tool), as well as rock and soil targets of opportunity. Subsets of the full image array can be selected and/or pixels can be binned to reduce data volume. Image compression will be used to maximize the information contained in the data returned to Earth. The resulting MI data will place other MER instrument data in context and aid in petrologic and geologic interpretations of rocks and soils on Mars.

K E Herkenhoff↗

A Quantum Annealing Computer Team Addresses Climate Change Predictability

The near confluence of the successful launch of the Orbiting Carbon Observatory2 on July 2, 2014 and the acceptance on August 20, 2015 by Google, NASA Ames Research Center and USRA of a 1152 qubit D-Wave 2X Quantum Annealing Computer (QAC), offered an exceptional opportunity to explore the potential of this technology to address the scientific prediction of global annual carbon uptake by land surface processes. At UMBC,we have collected and processed 20 months of global Level 2 light CO2 data as well as fluorescence data. In addition we have collected ARM data at 2sites in the US and Ameriflux data at more than 20 stations. J. Dorband has developed and implemented a multi-hidden layer Boltzmann Machine (BM) algorithm on the QAC. Employing the BM, we are calculating CO2 fluxes by training collocated OCO-2 level 2 CO2 data with ARM ground station tower data to infer to infer measured CO2 flux data. We generate CO2 fluxes with a regression analysis using these BM derived weights on the level 2 CO2 data for three Ameriflux sites distinct from the ARM stations. P. Gentine has negotiated for the access of K34 Ameriflux data in the Amazon and is applying a neural net to infer the CO2 fluxes. N. Talik validated the accuracy of the BM performance on the QAC against a restricted BM implementation on the IBM Softlayer Cloud with the Nvidia co-processors utilizing the same data sets. G. Nearing and K. Harrison have extended the GSFC LIS model with the NCAR Noah photosynthetic parameterization and have run a 10 year global prediction of the net ecosystem exchange. C. Pellisier is preparing a BM implementation of the Kalman filter data assimilation of CO2 fluxes. At UMBC, R. Prouty is conducting OSSE experiments with the LISNoah model on the IBM iDataPlex to simulate the impact of CO2 fluxes to improve the prediction of global annual carbon uptake. J. LeMoigne and D. Simpson have developed a neural net image registration system that will be used for MODIS ENVI and will be converted to a BM algorithm implementation on the QAC. The first integer adder has been implemented on the D-Wave 2X by A. Shehab that will perform HAAR wavelets for image compression of MODIS scenes. Finally, based on the next generations of QACs, we are preparing a 5-year performance road map on the scalability of the current QAC algorithms.

Science Data Processing↗

Multi-GPU implementation of a VMAT treatment plan optimization algorithm

Purpose: Volumetric modulated arc therapy (VMAT) optimization is a computationally challenging problem due to its large data size, high degrees of freedom, and many hardware constraints. High-performance graphics processing units (GPUs) have been used to speed up the computations. However, GPU’s relatively small memory size cannot handle cases with a large dose-deposition coefficient (DDC) matrix in cases of, e.g., those with a large target size, multiple targets, multiple arcs, and/or small beamlet size. The main purpose of this paper is to report an implementation of a column-generation-based VMAT algorithm, previously developed in the authors’ group, on a multi-GPU platform to solve the memory limitation problem. While the column-generation-based VMAT algorithm has been previously developed, the GPU implementation details have not been reported. Hence, another purpose is to present detailed techniques employed for GPU implementation. The authors also would like to utilize this particular problem as an example problem to study the feasibility of using a multi-GPU platform to solve large-scale problems in medical physics. Methods: The column-generation approach generates VMAT apertures sequentially by solving a pricing problem (PP) and a master problem (MP) iteratively. In the authors’ method, the sparse DDC matrix is first stored on a CPU in coordinate list format (COO). On the GPU side, this matrix is split into four submatrices according to beam angles, which are stored on four GPUs in compressed sparse row format. Computation of beamlet price, the first step in PP, is accomplished using multi-GPUs. A fast inter-GPU data transfer scheme is accomplished using peer-to-peer access. The remaining steps of PP and MP problems are implemented on CPU or a single GPU due to their modest problem scale and computational loads. Barzilai and Borwein algorithm with a subspace step scheme is adopted here to solve the MP problem. A head and neck (H and N) cancer case is then used to validate the authors’ method. The authors also compare their multi-GPU implementation with three different single GPU implementation strategies, i.e., truncating DDC matrix (S1), repeatedly transferring DDC matrix between CPU and GPU (S2), and porting computations involving DDC matrix to CPU (S3), in terms of both plan quality and computational efficiency. Two more H and N patient cases and three prostate cases are used to demonstrate the advantages of the authors’ method. Results: The authors’ multi-GPU implementation can finish the optimization process within ∼1 min for the H and N patient case. S1 leads to an inferior plan quality although its total time was 10 s shorter than the multi-GPU implementation due to the reduced matrix size. S2 and S3 yield the same plan quality as the multi-GPU implementation but take ∼4 and ∼6 min, respectively. High computational efficiency was consistently achieved for the other five patient cases tested, with VMAT plans of clinically acceptable quality obtained within 23–46 s. Conversely, to obtain clinically comparable or acceptable plans for all six of these VMAT cases that the authors have tested in this paper, the optimization time needed in a commercial TPS system on CPU was found to be in an order of several minutes. Conclusions: The results demonstrate that the multi-GPU implementation of the authors’ column-generation-based VMAT optimization can handle the large-scale VMAT optimization problem efficiently without sacrificing plan quality. The authors’ study may serve as an example to shed some light on other large-scale medical physics problems that require multi-GPU techniques.

60 APPLIED LIFE SCIENCES↗

Development and Benchmarking of a Hybrid PIC Code For Dense Plasmas and Fast Ignition (Final Report)

Radiation processes play an important role in the study of both fast ignition and other inertial confinement schemes, such as plasma jet driven magneto-inertial fusion, both in their effect on energy balance, and in generating diagnostic signals. In the latter case, warm and hot dense matter may be produced by the convergence of a plasma shell formed by the merging of an assembly of high Mach number plasma jets. This innovative approach has the potential advantage of creating matter of high energy densities in voluminous amount compared with high power lasers or particle beams. An important application of this technology is as a plasma liner for the flux compression of magnetized plasma to create ultra-high magnetic fields and burning plasmas. HyperV Technologies Corp. has been developing plasma jet accelerator technology in both coaxial and linear railgun geometries to produce plasma jets of sufficient mass, density, and velocity to create such imploding plasma liners. An enabling tool for the development of this technology is the ability to model the plasma dynamics, not only in the accelerators themselves, but also in the resulting magnetized target plasma and within the merging/interacting plasma jets during transport to the target. Welch pioneered numerical modeling of such plasmas (including for fast ignition) using the LSP simulation code. Lsp is an electromagnetic, parallelized, plasma simulation code under development since 1995. It has a number of innovative features making it uniquely suitable for modeling high energy density plasmas including a hybrid fluid model for electrons that allows electrons in dense plasmas to be modeled with a kinetic or fluid treatment as appropriate. In addition to in-house use at Voss Scientific, several groups carrying out research in Fast Ignition (LLNL, SNL, UCSD, AWE (UK), and Imperial College (UK)) also use LSP. A collaborative team consisting of HyperV Technologies Corp., Voss Scientific LLC, FAR-TECH, Inc., Prism Computational Sciences, Inc. and Advanced Energy Systems Inc. joined efforts to develop new physics and numerical models for LSP in several key areas to enhance the ability of LSP to model high energy density plasmas (HEDP). This final report details those efforts. Areas addressed in this research effort include: adding radiation transport to LSP, first in 2D and then fully 3D, extending the EMHD model to 3D, implementing more advanced radiation and electrode plasma boundary conditions, and installing more efficient implicit numerical algorithms to speed complex 2-D and 3-D computations. The new capabilities allow modeling of the dominant processes in high energy density plasmas, and further assist the development and optimization of plasma jet accelerators, with particular attention to MHD instabilities and plasma/wall interaction (based on physical models for ion drag friction and ablation/erosion of the electrodes). In the first funding cycle we implemented a solver for the radiation diffusion equation. To solve this equation in 2-D, we used finite-differencing and applied the parallelized sparse-matrix solvers in the PETSc library (Argonne National Laboratory) to the resulting system of equations. A database of the necessary coefficients for materials of interest was assembled using the PROPACEOS and ATBASE codes from Prism. The model was benchmarked against Prism's 1-D radiation hydrodynamics code HELIOS, and against experimental data obtained from HyperV's separately funded plasma jet accelerator development program. Work in the second funding cycle focused on extending the radiation diffusion model to full 3-D, continued development of the EMHD model, optimizing the direct-implicit model to speed up calculations, add in multiply ionized atoms, and improved the way boundary conditions are handled in LSP. These new LSP capabilities were then used, along with analytic calculations and Mach2 runs, to investigate plasma jet merging, plasma detachment and transport, restrike and advanced jet accelerator design. In addition, a strong linkage to diagnostic measurements was made by modeling plasma jet experiments on PLX to support benchmarking of the code. A large number of upgrades and improvements advancing hybrid PIC algorithms were implemented in LSP during the second funding cycle. These include development of fully 3D radiation transport algorithms, new boundary conditions for plasma-electrode interactions, and a charge conserving equation of state that permits multiply ionized high-Z ions. The final funding cycle focused on 1) mitigating the effects of a slow-growing grid instability which is most pronounced in plasma jet frame expansion problems using the two-fluid Eulerian remap algorithm, 2) extension of the Eulerian Smoothing Algorithm to allow EOS/Radiation modeling, 3) simulations of collisionless shocks formed by jet merging, 4) simulations of merging jets using high-Z gases, 5) generation of PROPACEOS EOS/Opacity databases, 6) simulations of plasma jet transport experiments, 7) simulations of plasma jet penetration through transverse magnetic fields, and 8) GPU PIC code development. The tools developed during this project are applicable not only to the study of plasma jets, but also to a wide variety of HEDP plasmas of interest to DOE, including plasmas created in short-pulse laser experiments performed to study fast ignition concepts for inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗

Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation

Purpose: Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior–inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). Methods: Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. Results: Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior–inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. Conclusions: The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating a finite-strain phase-field model of fracture for bonded granular materials with uncertainty quantification

To study the mechanical behavior of mock high explosives, an experimental and simulation program was developed to calibrate, with quantified uncertainty, a material model of the bonded granular material Idoxuridine and nitroplasticized Estane-5703. This paper reports on the efficacy of such a framework as a generalizable methodology for calibrating material models against experimental data with uncertainty quantification. Additionally, this paper studies the effect of two manufacturing temperatures and three initial granular configurations on the unconfined compressive behavior of the resulting bonded granular materials. In each of these cases, the same calibration framework was used; in that, hundreds of high-fidelity direct numerical simulations using a new, graphics processing unit-enabled, high-performance finite element method software, Ratel, were run to calibrate a finite-strain phase-field fracture model against experimental data. It was found that manufacturing temperature influenced the elastic response of the mock high explosives, with higher temperatures yielding a stiffer response. By contrast, it was found that the initial configuration of the grains had a negligible impact on the overall behavior of the mock high explosives though it remains possible that local damage accumulation within the specimens could be altered by the initial configurations. Overall, the calibration framework was successful at creating well-calibrated models, showing its usefulness as an engineering and scientific tool.

36 MATERIALS SCIENCE↗

Computational study of TATB

We have performed a computational study of TATB. The study is composed of two parts, one where we perform static T = 0 K calculations with several different DFT functionals, to investigate structural properties and obtain a cold curve. Even though the functionals used in this study give poor results at ambient pressure, they perform much better at compression, when the dominance of the van der Waals’ forces in the binding is replaced by more normal interactions. In particular AM05 gives good results, mainly because it doesn’t include any “faulty” van der Waals’. Indeed the van der Waals’ corrected functional (PBE+D2) results shows the worst performance on structural properties. For the cold curve the PBE+D2 functional gives the best results compared to experiments (room temperature) but since the structural properties were bad with this functional we cannot for sure say that this is in any way a validation. It is shown that scaling the AM05 results with a common factor reproduces the experimental data. We leave the question on why to a follow up study but speculate that maybe the experiment and our calculations do not represent the same system set-up. From the structural properties we identify a site in the TATB lattice that contains a high concentration of oxygen and hydrogen. The consequences of this finding, if any, are left to a future project. In the second part of the study we perform extensive high-quality DFT-MD (molecular dynamics with DFT forces) calculations to obtain points on the Hugoniot. This part of the study did not get finished within this project and a more extensive summary of this part will be given in a follow up report at a future date. However, we show that obtaining calculated data is essential for equations of state development since the existing experimental Hugoniot data barely deviates from room temperature isotherm data and thus give no information of the high temperature dependency of materials properties. Our conclusion so far in the project is that being able to calculate materials properties is essential for high explosives since experiments are unable to give information in the high temperature part of phase space. While blind use of DFT cannot (yet) give unambiguous answers, we can still explore qualitatively and use such information to guide us in EOS development. However, the main conclusion is that we need better functionals in DFT to easily extract needed properties from calculations.

36 MATERIALS SCIENCE↗

What to Support When You’re Compressing

Over the last nearly 20 years, lossy compression has become an essential aspect of HPC applications’ data pipelines, allowing them to overcome limitations in storage capacity and bandwidth and, in some cases, increase computational throughput and capacity. However, with the adoption of lossy compression comes the requirement to assess and control the impact lossy compression has on scientific outcomes. In this work, we take a major step forward in describing the state of practice and by characterizing workloads. We examine applications’ needs and compressors’ capabilities across 9 different supercomputing application domains. We present 24 takeaways that provide best practices for applications, operational impacts for facilities achieving compressed data, and gaps in application needs not addressed by production compressors that point towards opportunities for future compression research.

Error-Bounded Lossy Compression↗