Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Total dose and dose rate models for bipolar transistors in circuit simulation

The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

Campbell, Phillip Montgomery↗

Radiological Dose Calculations And Supplemental Dose Assessment Data For Neshap Compliance For SNL Nevada Facilities 1996.

Operations of Sandia National Laboratories, Nevada (SNL/NV) at the Tonopah Test Range (TTR) resulted in no planned point radiological releases during 1996. Other releases from SNL/NV included diffuse transuranic sources consisting of the three Clean Slate sites. Air emissions from these sources result from wind resuspension of near-surface transuranic contaminated soil particulates. The total area of contamination has been estimated to exceed 20 million square meters. Soil contamination was documented in an aerial survey program in 1977 (EG&G 1979). Surface contamination levels were generally found to be below 400 pCi/g of combined plutonium-238, plutonium-239, plutonium-240, and americium-241 (i.e., transuranic) activity. Hot spot areas contain up to 43,000 pCi/g of transuranic activity. Recent measurements confirm the presence of significant levels of transuranic activity in the surface soil. An annual diffuse source term of 0.39 Ci of transuranic material was calculated for the cumulative release from all three Clean Slate sites. A maximally exposed individual dose of 1.1 mrem/yr at the TTR airport area was estimated based on the 1996 diffuse source release amounts and site-specific meteorological data. A population dose of 0.86 person-rem/yr was calculated for the local residents. Both dose values were attributable to inhalation of transuranic contaminated dust.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation of the absorbed dose and dose equivalent induced by medium energy neutrons and protons and comparison with experiment

Monte Carlo calculations have been carried out to determine the absorbed dose and dose equivalent for 592-MeV protons incident on a cylindrical phantom and for neutrons from 580-MeV proton-Be collisions incident on a semi-infinite phantom. For both configurations, the calculated depth dependence of the absorbed dose is in good agreement with experimental data.

Armstrong, T. W.↗

Total-dose and dose-rate dependence of proton damage in MOS devices during and after irradiation

Rad-hard CMOS/bulk inverters with input gates high and low were irradiated by protons with a nominal energy of 8 MeV in an effort to determine the total-dose and dose-rate dependence of threshold voltage shifts, both during and immediately after irradiation and over extended periods of time thereafter. It is shown that the effects in rad-hard MOS devices which are produced by specific proton and electron energies in the space environment could be simulated by cobalt-60 induced effects through careful and proper selection of total does and dose rates. This selection must be based on an experimentally established relationship of Co-60 to electron or proton damage. It is demonstrated that the simulation can be accomplished both during and after irradiation, in the long-term postirradiation period, as well as in the damage state immediately after bombardment.

Stassinopoulos, E. G.↗

Dose-Volume Analysis of Predictors for Gastrointestinal Toxicity After Concurrent Full-Dose Gemcitabine and Radiotherapy for Locally Advanced Pancreatic Adenocarcinoma

Purpose: To identify dosimetric predictors for the development of gastrointestinal (GI) toxicity in patients with locally advanced pancreatic adenocarcinoma (LAPC) treated with concurrent full-dose gemcitabine and radiotherapy (GemRT). Methods and Materials: From June 2002 to June 2009, 46 LAPC patients treated with definitive GemRT were retrospectively analyzed. The stomach and duodenum were retrospectively contoured separately to determine their dose-volume histogram (DVH) parameters. GI toxicity was defined as Grade 3 or higher GI toxicity. The follow-up time was calculated from the start of RT to the date of death or last contact. Univariate analysis (UVA) and multivariate analysis (MVA) using Kaplan-Meier and Cox regression models were performed to identify risk factors associated with GI toxicity. The receiver operating characteristic curve and the area under the receiver operating characteristic curve (AUC) were used to determine the best DVH parameter to predict for GI toxicity. Results: Of the patients, 28 (61%) received concurrent gemcitabine alone, and 18 (39%) had concurrent gemcitabine with daily erlotinib. On UVA, only the V{sub 20Gy} to V{sub 35Gy} of duodenum were significantly associated with GI toxicity (all p {<=} 0.05). On MVA, the V{sub 25Gy} of duodenum and the use of erlotinib were independent risk factors for GI toxicity (p = 0.006 and 0.02, respectively). For the entire cohort, the V{sub 25Gy} of duodenum is the best predictor for GI toxicity (AUC = 0.717), and the 12-month GI toxicity rate was 8% vs. 48% for V{sub 25Gy} {<=} 45% and V{sub 25Gy} > 45%, respectively (p = 0.03). However, excluding the erlotinib group, the V{sub 35Gy} is the best predictor (AUC = 0.725), and the 12-month GI toxicity rate was 0% vs. 41% for V{sub 35Gy} {<=} 20% and V{sub 35Gy} > 20%, respectively (p = 0.04). Conclusions: DVH parameters of duodenum may predict Grade 3 GI toxicity after GemRT for LAPC. Concurrent use of erlotinib during GemRT may increase GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3-23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Receiver Operating Curve Analysis and Machine Learning With an Independent Dose Calculation System Reduces the Number of Physical Dose Measurements Required for Patient-Specific Quality Assurance

Our purpose was to assess the use of machine learning methods and Mobius 3D (M3D) dose calculation software to reduce the number of physical ion chamber (IC) dose measurements required for patient-specific quality assurance during corona virus disease 2019.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mean Heart Dose Is an Inadequate Surrogate for Left Anterior Descending Coronary Artery Dose and the Risk of Major Adverse Cardiac Events in Lung Cancer Radiation Therapy

Mean heart dose (MHD) over 10 Gy and left anterior descending (LAD) coronary artery volume (V) receiving 15 Gy (V15Gy) greater than 10% can significantly increase the risk of major adverse cardiac events (MACE) in patients with non-small cell lung cancer (NSCLC). We sought to characterize the discordance between MHD and LAD dose and the association of this classification on the risk of MACE after radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Dose-Volume and Dose-Length Parameters for Cervical Esophageal Stricture in Head and Neck Irradiation with the 3DCRT and IMRT Technique

To quantify and compare dose-volume and dose-length parameters of cervical esophagus between three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiation therapy (IMRT) and to correlate with incidence of cervical strictures in head and neck cancer irradiation with radical intent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Jahn-Teller response induced by low-dose 10 MeV I{sup +} irradiation of La{sub 0.7}Ca{sub 0.3}MnO{sub 3−δ} films

The structural response of pulsed laser deposited La{sub 0.7}Ca{sub 0.3}Mn0{sub 3−δ} films to low-level 10 MeV I{sup +} irradiation is correlated with magnetic and electronic properties. A series of annealed pulsed laser deposited films were subjected to ion irradiation at doses of 0.5–2.0 × 10{sup 13} 10 MeV iodine ions/cm{sup 2}. X-ray diffraction measurements show no measurable increase in the full width at half maximum values of major reflections before and after irradiation. Extended x-ray absorption fine structure analyses (EXAFS), employing both a model independent fitting using expanded cumulants as well as a nonlinear least squares multiple scattering model based on FEFF generated theoretical EXAFS data, were employed to measure local properties relative to the Mn ions. Increasing irradiation doses lead to an unambiguous evolution of MnO{sub 6} octahedra from highly symmetric (i.e., undistorted) to a clear bimodal structure in which the MnO{sub 6} octahedra are measured to undergo a c-axis stretching bearing resemblance to a Jahn-Teller distortion. Concomitantly, the metal to insulator transition temperature decreases more than 270 K and the magnetoresistance increases from 10{sup 2}% to 10{sup 6}%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Total Ionizing Dose Effects on Ge Channel $p$ FETs with Raised ${\rm Si}_{0.55}{\rm Ge}_{0.45}$ Source/Drain

Here, the total ionizing dose response of Ge channel pFETs with raised Si 0.55 Ge 0.45 source/drain is investigated under different radiation bias conditions. Threshold-voltage shifts and transconductance degradation are noticeable only for negative-bias (on state) irradiation, and are mainly due to negative bias-temperature instability (NBTI). Nonmonotonic leakage changes during irradiation are observed, which are attributed to the competition of radiation-induced field transistor leakage and S/D junction leakage.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Physiologically Based Pharmacokinetic (PBPK) Modeling to Support Dose Selection: Report of an FDA Public Workshop on PBPK: Physiologically Based Pharmacokinetic Modeling to Support Dose Selection

A workshop entitled “Application of Physiologically-based Pharmacokinetic (PBPK) Modeling to Support Dose Selection” was hosted on March 10, 2014 by the US Food and Drug Administration (FDA) at its White Oak Campus in Silver Spring, MD.1 The workshop endeavored to (i) assess the current state of knowledge in the application of PBPK in regulatory decision-making, and (ii) share and discuss best practices in the use of PBPK modeling to inform dose selection in specific patient populations. The conference benefited from strong and diverse participation from the FDA Center for Drug Evaluation and Research (CDER) leaders, European Medicine Agency (EMA) delegates, and pharmaceutical industry and academia representatives. The workshop commenced with plenary presentations by speakers from the FDA, industry, and academia. In the two panel sessions, detailed questions on the current status and future applications of PBPK in drug development and regulatory decisions were discussed. An important focus of the dialog was the need to better define what constitutes a credible physiological system and the evidentiary standards needed for using such a system in making regulatory decisions. This report provides a content summary of the workshop, based on plenary presentations and panel session transcripts posted on the FDA’s website.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Patient Skin Dose Evaluated Using Radiochromic Film and Dose Calculation Software

PurposeTo compare, in an interventional radiology setting, peak skin doses (PSDs) delivered as calculated using a dedicated software tool and as measured using radiochromic film. To assess the utility of this dose calculation software tool in routine clinical practice.Materials and MethodsFirst, radiochromic films were positioned on the examination table in the back of an adult anthropomorphic phantom to measure PSD, and X-ray examinations were simulated. Then, films were again positioned in the patient’s back for 59 thoracic or abdominopelvic endovascular interventions. The results obtained with the radiochromic films were taken as a reference and were statistically compared with those of the software.ResultsWith measured PSDs ranging from 100 to 7000 mGy, the median software–film difference was 8.5%. Lin’s concordance coefficient was 0.98 [0.97; 0.99] (p < 0.001), meaning that concordance was excellent between the two methods. For the films where PSD exceeded 1000 mGy, the median difference in the measured value was 8.7% [− 1.3; 21.1], with a maximum discrepancy of 34%. Lin’s concordance coefficient was 0.98 [0.96; 1] (p < 0.001), meaning that concordance was excellent between the two methods.ConclusionComparison between radiochromic films and the software tool showed that the software is a suitable tool for a simple and reliable estimation of PSD. The software seems to be a good alternative to films, whose use remains complex.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-rate controlled energy dispersive x-ray spectroscopic mapping of the metallic components in a biohybrid nanosystem

In this work, we showcase that through precise control of the electron dose rate, state-of-the-art large solid angle energy dispersive X-ray spectroscopy (EDS) mapping in aberration-corrected scanning transmission electron microscope (STEM) is capable of faithful and unambiguous chemical characterization of the Pt and Pd distribution in a peptide-mediated nanosystem. This low-dose-rate recording scheme adds another dimension of flexibility to the design of elemental mapping experiments, and holds significant potential for extending its application to a wide variety of beam sensitive hybrid nanostructures.

composition mapping↗

Structural changes caused by radiation-induced reduction and radiolysis: the effect of X-ray absorbed dose in a fungal multicopper oxidase

Radiation-induced reduction, radiolysis of copper sites and the effect of pH value together with the concomitant geometrical distortions of the active centres were analysed in several fungal (C. gallica) laccase structures collected at cryotemperature. This study emphasizes the importance of careful interpretation when the crystallographic structure of a metalloprotein is described. X-ray radiation induces two main effects at metal centres contained in protein crystals: radiation-induced reduction and radiolysis and a resulting decrease in metal occupancy. In blue multicopper oxidases (BMCOs), the geometry of the active centres and the metal-to-ligand distances change depending on the oxidation states of the Cu atoms, suggesting that these alterations are catalytically relevant to the binding, activation and reduction of O{sub 2}. In this work, the X-ray-determined three-dimensional structure of laccase from the basidiomycete Coriolopsis gallica (Cg L), a high catalytic potential BMCO, is described. By combining spectroscopic techniques (UV–Vis, EPR and XAS) and X-ray crystallography, structural changes at and around the active copper centres were related to pH and absorbed X-ray dose (energy deposited per unit mass). Depletion of two of the four active Cu atoms as well as low occupancies of the remaining Cu atoms, together with different conformations of the metal centres, were observed at both acidic pH and high absorbed dose, correlating with more reduced states of the active coppers. These observations provide additional evidence to support the role of flexibility of copper sites during O{sub 2} reduction. This study supports previous observations indicating that interpretations regarding redox state and metal coordination need to take radiation effects explicitly into account.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗