Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISEASE DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Volatiles from the necrophagous fly Cochliomyia macellaria (Diptera: Calliphoridae) as indicators of Salmonella exposure

Blow flies (Diptera: Calliphoridae) are crucial in forensic investigations due to their association with both living and dead humans and other animals. Additionally, their interactions with various resources and potential as vectors of pathogens of humans and other animals, thus, make them potential tools for biosurveillance. This study investigated the potential of monitoring volatile organic compounds (VOCs) emitted by blow flies exposed to Salmonella as a method for pathogen surveillance. Adult blow flies ( Cochliomyia macellaria ) were exposed, or not, to Salmonella enterica . Following exposure, VOCs released by the blow flies were collected and analyzed using gas chromatography-mass spectrometry (GC-MS). Results indicate a treatment by time interaction (P < 0.01). Indicator species analysis identified a single compound significantly associated with S. enterica exposure (P = 0.02), Nonane, 2,2,4,4,6,8,8-heptamethyl, potentially indicating an immune system response. Given a compound indicating exposure was detected, future research should determine if more replicates could detect more differences after Salmonella ingestion. This research highlights the potential of blow flies as biosurveillance tools and the potential value of volatiles for assessing their exposure to pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the Prostate Bed for Local Recurrence After Radical Prostatectomy Using Endorectal Magnetic Resonance Imaging

Purpose: To summarize the results of a 4-year period in which endorectal magnetic resonance imaging (MRI) was considered for all men referred for salvage radiation therapy (RT) at a single academic center; to describe the incidence and location of locally recurrent disease in a contemporary cohort of men with biochemical failure after radical prostatectomy (RP), and to identify prognostic variables associated with MRI findings in order to define which patients may have the highest yield of the study. Methods and Materials: Between 2007 and 2011, 88 men without clinically palpable disease underwent eMRI for detectable prostate-specific antigen (PSA) after RP. The median interval between RP and eMRI was 32 months (interquartile range, 14-57 months), and the median PSA level was 0.30 ng/mL (interquartile range, 0.19-0.72 ng/mL). Magnetic resonance imaging scans consisting of T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging were evaluated for features consistent with local recurrence. The prostate bed was scored from 0-4, whereby 0 was definitely normal, 1 probably normal, 2 indeterminate, 3 probably abnormal, and 4 definitely abnormal. Local recurrence was defined as having a score of 3-4. Results: Local recurrence was identified in 21 men (24%). Abnormalities were best appreciated on T2-weighted axial images (90%) as focal hypointense lesions. Recurrence locations were perianastomotic (67%) or retrovesical (33%). The only risk factor associated with local recurrence was PSA; recurrence was seen in 37% of men with PSA >0.3 ng/mL vs 13% if PSA {<=}0.3 ng/mL (P<.01). The median volume of recurrence was 0.26 cm{sup 3} and was directly associated with PSA (r=0.5, P=.02). The correlation between MRI-based tumor volume and PSA was even stronger in men with positive margins (r=0.8, P<.01). Conclusions: Endorectal MRI can define areas of local recurrence after RP in a minority of men without clinical evidence of disease, with yield related to PSA. Further study is necessary to determine whether eMRI can improve patient selection and success of salvage RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of remote sensors to relate biological and physical indicators to environmental and public health problems

Relationships between biological, ecological and botanical structures, and disease organisms and their vectors which might be detected and measured by remote sensing are determined. In addition to the use of trees as indicators of disease or potential disease, an attempt is made to identify environmental factors such as soil moisture and soil and water temperatures as they relate to disease or health problems and may be detected by remote sensing. The following three diseases and one major health problem are examined: Malaria, Rocky Mountain spotted fever, Encephalitis and Red Tide. It is shown that no single species of vascular plant nor any one environmental factor can be used as the indicator of disease or health problems. Entire vegetation types, successional stages and combinations of factors must be used.

Source record↗

Utilization of stress testing for low-risk patients with chest discomfort in the emergency department

Background: The management of patients presenting to an emergency department with chest discomfort at low-risk for acute coronary syndrome represents a common clinical challenge. Such patients are often triaged to chest pain units for monitoring and cardiac stress testing for further risk stratification. Methods: We conducted a retrospective study of 292 low-risk patients who presented to an emergency department with chest discomfort. We performed physician-adjudicated chart reviews of all patients with positive stress tests to assess downstream testing, subsequent coronary revascularization, and outcomes. Results: Of the 292 patients, 33 (11.3%) had stress tests positive for ischemia, and 12 (4.1%) underwent diagnostic cardiac catheterization. Of the 292 patients, 4 (1.4%) underwent coronary revascularization that may have resulted in a mortality benefit. Conclusion: These data suggest a very low yield of detecting clinically significant coronary disease with stress testing low-risk patients with chest discomfort in emergency department chest pain units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes, mediastinal lymph nodes, and unsuspected sites of distant metastasis. This information is important in the design of radiotherapy treatment fields and, therefore, we recommend that PET/CT be a component of initial staging for IBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge-altering releasable transporters (CARTs) for the delivery and release of mRNA in living animals

Significance Protein expression using mRNA has the potential to transform many areas of life science research and affect the prevention, detection, and treatment of disease. However, realizing this potential requires the development of readily accessible, efficacious, and safe delivery systems that can functionally deliver mRNA to cells in culture and in vivo. A class of materials developed for mRNA delivery is described that operates through an unprecedented self-immolation mechanism. These materials are accessed in two steps through an organocatalytic oligomerization. They noncovalently complex, protect, deliver, and release mRNA with >99% transfection efficiency in cultured cells and with robust protein expression in mice using multiple routes of administration. This mRNA delivery technology should be broadly applicable to numerous research and therapeutic applications.

59 BASIC BIOLOGICAL SCIENCES↗

Zone-based analysis for automated detection of abnormalities in chest radiographs

Purpose: The aim of this study was to develop an automated method for detection of local texture-based and density-based abnormalities in chest radiographs. Methods: The method was based on profile analysis to detect abnormalities in chest radiographs. In the method, one density-based feature, Density Symmetry Index, and two texture-based features, Roughness Maximum Index and Roughness Symmetry Index, were used to detect abnormalities in the lung fields. In each chest radiograph, the lung fields were divided into four zones initially and then the method was applied to each zone separately. For each zone, Density Symmetry Index was obtained from the projection profile of each zone, and Roughness Maximum Index and Roughness Symmetry Index were obtained by measuring the roughness of the horizontal profiles via moving average technique. Linear discriminant analysis was used to classify normal and abnormal cases based on the three indices. The discriminant performance of the method was evaluated using ROC analysis. Results: The method was evaluated on a database of 250 normal and 250 abnormal chest images. In the optimized conditions, the zone-based performance Az of the method for zones 1, 2, 3, and 4 were 0.917, 0.897, 0.892, and 0.814, respectively, and the case-based performance Az of the method was 0.842. Our previous method for detection of gross abnormalities was also evaluated on the same database. The case-based performance of our previous method was 0.689. Conclusions: In comparing the previous method and the new method proposed in this study, there was a great improvement by the new method for detection of local texture-based and density-based abnormalities. The new method combined with the previous one has potential for screening abnormalities in chest radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction of a novel ultrahigh sensitivity collimator for brain SPECT imaging

Purpose: Noise levels of brain SPECT images are highest in central regions, due to preferential attenuation of photons emitted from deep structures. To address this problem, the authors have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. This hybrid collimator consisted of ultrashort cone-beam holes in the central regions and slant-holes in the periphery (USCB). We evaluated this collimator for quantitative brain imaging tasks. Methods: Owing to the uniqueness of the USCB collimation, the hole pattern required substantial variations in collimator parameters. To utilize the lead-casting technique, the authors designed two supporting plates to position about 37 000 hexagonal, slightly tapered pins. The holes in the supporting plates were modeled to yield the desired focal length, hole length, and septal thickness. To determine the properties of the manufactured collimator and to compute the system matrix, the authors prepared an array of point sources that covered the entire detector area. Each point source contained 32 μCi of Tc-99m at the first scan time. The array was imaged for 5 min at each of the 64 shifted locations to yield a 2-mm sampling distance, and hole parameters were calculated. The sensitivity was also measured using a point source placed along the central ray at several distances from the collimator face. High-count projection data from a five-compartment brain phantom were acquired with the three collimators on a dual-head SPECT/CT system. The authors calculated Cramer-Rao bounds on the precision of estimates of striatal and background activity concentration. In order to assess the new collimation system to detect changes in striatal activity, the authors evaluated the precision of measuring a 5% decrease in right putamen activity. The authors also reconstructed images of projection data obtained by summing data from the individual phantom compartments. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 2.7 to 162. Examination of the projections of the point sources revealed that only a few holes were distorted or partially blocked, indicating that the intensive manual fabrication process was very successful. Better reconstructed phantom images were obtained from the USCB+FAN collimator pair than from either LEHR or FAN collimation. For the left caudate, located near the center of the brain, the detected counts were 9.8 (8.3) times higher for UCSB compared with LEHR (FAN), averaged over 60 views. The task-specific SNR for detecting a 5% decrease in putamen uptake was 7.4 for USCB and 3.2 for LEHR. Conclusions: The authors have designed and manufactured a novel collimator for brain SPECT imaging. The sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data requires a measured system matrix. The authors have demonstrated the potential of USCB collimation for improved precision in estimating striatal uptake. The novel collimator may be useful for early detection of Parkinson’s disease, and for monitoring therapy response and disease progression.

60 APPLIED LIFE SCIENCES↗

Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment quality. The performance of our automated method was evaluated by comparing the automatically identified best-quality segments identified by the computer to those selected by the observers. Results: For the 20 test cases, 254 groups of corresponding vessel segments were identified after multiple phase registration and recursive matching. The AI-BQ segments agreed with the radiologist’s top 2 ranked segments in 78.3% of the 254 groups (Cohen’s kappa 0.60), and with the 4 nonradiologist observers in 76.8%, 84.3%, 83.9%, and 85.8% of the 254 groups. In addition, 89.4% of the AI-BQ segments agreed with at least two observers’ top 2 rankings, and 96.5% agreed with at least one observer’s top 2 rankings. In comparison, agreement between the four observers’ top ranked segment and the radiologist’s top 2 ranked segments were 79.9%, 80.7%, 82.3%, and 76.8%, respectively, with kappa values ranging from 0.56 to 0.68. Conclusions: The performance of our automated method for selecting the best-quality coronary segments from a multiple-phase cCTA acquisition was comparable to the selection made by human observers. This study demonstrates the potential usefulness of the automated method in clinical practice, enabling interpreting physicians to fully utilize the best available information in cCTA for diagnosis of coronary disease, without requiring manual search through the multiple phases and minimizing the variability in image phase selection for evaluation of coronary artery segments across the diversity of human readers with variations in expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

In Vitro Assessment of the In Vivo Stability of Cu-64 Radiopharmaceuticals

Research Plans: The successful development of Cu-64 radiopharmaceuticals depends upon retention of the Cu-64 atom in the radiopharmaceutical. To date, the focus has been on the development of chelators that better retain Cu-64, but there has been no effort to develop an effective method by which improved retention may be measured. In the absence of a suitable analytical method, the stability of Cu-64 radiopharmaceuticals is estimated indirectly, with decreased liver uptake suggesting higher in vivo complex stability. But this approach is inadequate for radiopharmaceuticals, such as radiolabeled antibodies, that are expected to accumulate in the liver even when there is no free Cu-64 present. The absence of such a method has also hampered efforts to systematically evaluate the chemical factors that may give rise to improved retention. The objective of this project is to develop and validate such a method. Accomplishments: The two primary accomplishments of this project will be 1) the development and validation of a method to measure the stability of Cu-64 radiopharmaceuticals and 2) the determination of the chemical factors that define the in vivo stability of Cu 64 radiopharmaceuticals. Because Cu(II) is extremely labile, the in vivo stability of Cu-64 radiopharmaceuticals is not primarily determined by the amount of free Cu that is present at any given time or by the thermodynamic stability constants, but rather by the rate at which Cu is lost from the complex, the dissociation rate constant, kd. The dissociation rate constants of the Cu-64 complexes from a series of bifunctional chelators (BFCs) will be measured using Free Ion Selective Radiotracer Extraction (FISRE), a technique originally developed to measure bioavailable Cu in environmental samples. FISRE will also be applied to the determination of the kd's of a series of reference Cu-64 complexes to determine the chemical factors that define the in vivo stability of Cu-64 radiopharmaceuticals. Potential Benefits: The FISRE method that will be used in this project, once validated, will provide researchers with a core technology by which the stability of Cu 64 radiopharmaceuticals can be accurately measured. In the short-term, we expect to produce extensive data regarding the stability of Cu-64 complexes of ligands of radiopharmaceutical interest, primarily those that are most commonly used as BFCs (e.g., DOTA, TETA). These data will provide a quantitative basis for deciding which ligands may be best suited for use as BFCs, data that is not currently available. In the intermediate term, we expect that these results will facilitate the development of new Cu-64 radiopharmaceuticals by providing a quantitative approach to assessing the stability of Cu-64 chelates. This innovative methodology will enable investigators to quantitatively compare the ability of different BFCs to retain Cu-64 in vivo. The benefits of this approach will be best seen in the development of Cu-64-labeled monoclonal antibodies where the accumulation of antibodies in the liver obviates liver uptake as an effective surrogate measure of Cu-64 lability. In the longer-term, we anticipate an improvement in the way in which various diseases (especially cancer) are detected, diagnosed, staged, and treated. This method will also enable researchers to distinguish differences in biodistribution that may arise from differences in charge, lipophilicity, etc. from those that may arise from loss of Cu-64 from the chelator. Last, this novel quantitative tool will allow investigators to evaluate the chemical factors that determine the in vivo stability of Cu-64 radiopharmaceuticals laying the groundwork for the future development of more effective Cu-64 radiopharmaceuticals. Once the feasibility of this method is established, it can also be used to evaluate the stability of other metalloradiopharmaceuticals including those based on Ga-68, a radionuclide that is showing great promise in tumor imaging.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Final Technique Report of SMIRTP

Positron emission tomography (PET) imaging agents play significantly roles in detection and management of diseases. There are urgent needs to increase output and translate probes more rapidly for clinical use. Moreover, there is a crucial lack of trained radiochemists and nuclear medicine physician scientists to meet the increasing demand of developing novel PET imaging probes for clinical use. With strong support and commitment from Office of Science, Department of Energy, coupled with an expanding interest in the benefits of molecular and biomedical imaging, Stanford Molecular Imaging Research and Training Program (SMIRT) has advanced generalizable strategies to develop PET agents and multimodality radiotracers that can target most cell surface receptors. These radioactive imaging agents have been based on novel protein scaffolds such as knottins and Affibodies, and newly developed gold nanoparticles and organic nanoparticles. The projects yielded several new classes of knottin-based imaging probes that target α v b 6 , α v b 3 , EGFR, melanin, etc. as single or multimodal imaging agents. More importantly, the projects firmly established the development of knottins based PET probes as a generalizable approach for many tumor targets. Three novel PET probes have been successfully developed from research lab and translated into pilot clinical patient imaging studies during the course of the funding period. We also increased the number of trained radiochemists/nuclear medicine physician-scientists and provided them with comprehensive training regarding probe development and the clinical translational process. The research opportunities of this SMIRT engaged trainees in cutting-edge projects with experienced mentors and improve cross-training between radiochemists and nuclear medicine physicians. The training enabled an overall understanding of the complete probe development and clinical translation process, and encouraged trainees to pursue rewarding careers in radionuclide based imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Handling and Containment Considerations in Support of an American Medical Isotope Producer

This work will discuss evaluation and design of new and modified facility level radiological containment, transfer, and handling systems in support of the United States’ American Medical Isotope Production Act. In the United States alone, Molybdenum-99 (Mo-99) is used as a precursor to locally generate its decay product, technetium-99m (Tc-99m), for use in approximately 40,000 medical procedures every day to detect cancer and heart disease. Currently, however, Mo-99 is primarily produced overseas and typically requires highly enriched uranium (HEU) which is classified as weapon -usable. This poses a serious security risk to the United States and, in 2012, Congress passed the American Medical Isotope ACT which aimed to cease all Mo-99 production that requires HEU and support American based companies who have found safer production methods. Through this effort, a system was designed and developed to access irradiated material in processing hot cells for ease of material introduction and removal in the confined area. The proposed solution uses a double-door design that allows for easy access to material while also providing shielding through a mechanically manipulated carousel. A system was also designed to transport irradiated materials from target reactors to a target receipt box using a rail guide system, pneumatic motor, and lead screw drive.

07 ISOTOPE AND RADIATION SOURCES↗

Programmed Multiphasic Health Testing

Multiphase health screening procedures are advocated for detection and prevention of disease at an early stage through risk factor analysis. The use of an automated medical history questionnaire together with scheduled physical examination data provides a scanning input for computer printout. This system makes it possible to process laboratory results from 1,000 to 2,000 patients for biochemical determinations on an economically feasible base.

Hershberg, P. I.↗

Analysis of volatile organic compounds

An apparatus and method are described for reproducibly analyzing trace amounts of a large number of organic volatiles existing in a gas sample. Direct injection of the trapped volatiles into a cryogenic percolum provides a sharply defined plug. Applications of the method include: (1) analyzing the headspace gas of body fluids and comparing a profile of the organic volatiles with standard profiles for the detection and monitoring of disease; (2) analyzing the headspace gas of foods and beverages and comparing the profile with standard profiles to monitor and control flavor and aroma; and (3) analyses for determining the organic pollutants in air or water samples.

Zlatkis, A.↗

Eighth year projects and activities of the Environmental Remote Sensing Applications Laboratory (ERSAL)

Projects completed for the NASA Office of University Affairs include the application of remote sensing data in support of rehabilitation of wild fire damaged areas and the use of LANDSAT 3 return beam vidicon in forestry mapping applications. Continuing projects for that office include monitoring western Oregon timber clearcut; detecting and monitoring wheat disease; land use monitoring for tax assessment in Umatilla, Lake, and Morrow Counties; and the use of Oregon Air National Guard thermal infrared scanning data. Projects funded through other agencies include the remote sensing inventory of elk in the Blue Mountains; the estimation of burned agricultural acreage in the Willamette Valley; a resource inventory of Deschutes County; and hosting a LANDSAT digital workshop.

Lewis, A. J.↗

Use of remote sensing for land use policy formulation

Progress in studies for using remotely sensed data for assessing crop stress and in crop estimation is reported. The estimation of acreage of small forested areas in the southern lower peninsula of Michigan using LANDSAT data is evaluated. Damage to small grains caused by the cereal leaf beetle was assessed through remote sensing. The remote detection of X-disease of peach and cherry trees and of fire blight of pear and apple trees was investigated. The reliability of improving on standard methods of crop production estimation was demonstrated. Areas of virus infestation in vineyards and blueberry fields in western and southwestern Michigan were identified. The installation and systems integration of a microcomputer system for processing and making available remotely sensed data are described.

Source record↗