Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Evaluation of composite bolometers at 0.4 Kelvin

Composite bolometer structures have provided the most sensitive IR detectors for operation at helium-4 temperatures of 1.5K. Below 1.5K the electrical and thermal properties change significantly and the performance characteristics cannot be accurately extrapolated for composite bolometers at helium-3 temperatures of 0.4K. The paper deals with experimentally assessed performance of composite bolometers at 0.4K. It is found that sensitivity estimates derived from electrical or load curve properties can overestimate the responsivity to radiation by several orders of magnitude depending upon a particular material behavior. For many near-millimeter applications background power levels are several nanowatts and the associated photon noise plus Johnson and phonon noise components impose a fundamental detection limit of about 5 x 10 to the -15thW/Hz to the -1/2. We have successfully fabricated composite bolometers which at 0.4 K and millimeter wavelengths achieve a noise equivalent power of 7 x 10 to the -15thW/Hz to the -1/2 coupled with a large absorbing area (0.3 sq cm) and a fast response time (2 msec.).

El-Ataway, S.↗

Microsecond flares in gamma-ray bursts

It has been suggested that gamma-ray burst light curves may consist of many superposed flares with a duration shorter than 30/microsec. If true, the implications for the interpretation of burst data are enormous. With the launch of the Compton Gamma-Ray Observatory, four predictions of Mitrofanov's (1989) suggestion can be tested. Our results which contradict this suggestion are (1) the photon arrival times are not correlated between independent detectors, (2) the spectral hardness and intensity does not depend on the detector area, (3) the bursts seen by detectors which measure photon positions do not see microsecond flares, and (4) burst positions deduced from detectors with different projected areas are close to the positions deduced from time-of-flight differences between separated spacecraft. We conclude, therefore, that gamma-ray bursts are not composed of microsecond flares.

Schaefer, Bradley E.↗

Theoretical light curve of a Type 2p supernova

The light curve and other observable diagnostics are presented for what should be a typical Type II 'plateau' supernova, the explosion of a 15 solar mass red supergiant. The calculations are carried out using a multi-frequency radiation transport code that includes opacity from all important mechanisms-bound-bound, bound-free, free-free, and electron scattering. It is found that the inclusion of opacity sources besides electron scattering increases the computed lenght of the plateau in the 15 solar mass model by approximately 30 days. Especially important is the ultraviolet cutoff caused by a thick forest of lines. Deposition and escape of gamma-rays from radioactive decay are also accurately simulated. We find that the presence of 0.06 solar mass of ejected Ni-56 extends the length of the plateau from approximately 100 days to approximately 140 dys. Because of the large hydrogen envleope and radius in this model, mixing does not appreciably alter the bolometric light curve, although it does change the gamma-ray light curve significantly. With 0.06 solar mass of ejected Ni-56, the unmixed (mixed) model peaks in escaping gamma-rays at 576 (466) days with gamma-ray luminosity of 3 x 10(exp 38) ergs/s. Except for the local group, the gamma-rays from an extragalactic 15 solar mass SNe IIp will be too faint to detect with any exsiting detectors. However, a Galactic SNe IIp would be quite bright and easily detectable.

Eastman, Ronald G.↗

Superconducting Films for Absorber-coupled MKID Detectors for Sub-millimeter and Far-infrared Astronomy

We describe measurements of the properties, at dc, gigahertz, and terahertz frequencies, of thin superconducting films with relatively high normal state sheet resistance. Such films can be applied to construct microwave kinetic inductance detector sensor arrays for submillimeter and far-infrared astronomical applications in which the incident power excites quasiparticles directly in a superconducting resonator that is configured to present a matched-impedance to the high frequency radiation being detected. For several materials, and a range of thicknesses down to 10 nm, we present measurements of normal state sheet resistance, resistance-temperature curves for the superconducting transition, quality factor and kinetic inductance fraction for microwave resonators made from patterned films, and terahertz measurements of the sheet impedance measured with a Fourier Transform Spectrometer.

Stevenson, T. R.↗

Sheath effects on current collection by particle detectors with narrow acceptance angles

Restriction of the aperture acceptance angle of an ion or electron trap on an attracting spacecraft significantly alters the volt-ampere characteristics of the instrument in a low Mach number plasma. It is shown when the angular acceptance of the aperture is restricted the current to the collector tends to be independent of the Debye length. Expressions for the RPA characteristics for both a thin sheath and a thick sheath are derived; and it is shown that as the aperture is narrowed the curves tend toward equivalence.

Singh, N.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Galactic distribution models of gamma-ray burst sources

The log N-log S relationships for several galactic distribution models of gamma-ray burst sources are derived. The resulting curves are substantially different from the galactic curves usually assumed (slope = -1). There is a relatively weak dependence on the radial distribution assumed but a strong dependence on scale height. Available observational data from several experiments appear to rule out both thin disk distributions and extended halo distributions which have a strong radial density dependence. The prospects are good for obtaining self-consistent distribution data from future large-area detectors.

Fishman, G. J.↗

E2003 + 225 - A 3h 42m AM Herculis type binary system

The bright soft X-ray source E2003 + 225, originally discovered by the HEAO 1 low-energy detectors, has been found to be a new AM Herculis type binary. The optical counterpart shows a rich emission spectrum of He II, He I, and H as well as circular and linear polarization. Larger polarization in the near-infrared than in the ultraviolet argues for its origin as high harmonic cyclotron emission. Optical photometry, polarimetry, spectroscopy, and the X-ray light curves are all consistent with an orbital period of 222.51 m, the longest period known for AM Herculis systems, and only the second on the long side of the 2-3 hour cataclysmic variable period gap.

Takalo, L. O.↗

An analysis of carrier phase jitter in an MPSK receiver utilizing map estimation

The use of 8 and 16 PSK TCM to support satellite communications in an effort to achieve more bandwidth efficiency in a power-limited channel has been proposed. This project addresses the problem of carrier phase jitter in an M-PSK receiver utilizing the high SNR approximation to the maximum aposteriori estimation of carrier phase. In particular, numerical solutions to the 8 and 16 PSK self-noise and phase detector gain in the carrier tracking loop are presented. The effect of changing SNR on the loop noise bandwidth is also discussed. These data are then used to compute variance of phase error as a function of SNR. Simulation and hardware data are used to verify these calculations. The results show that there is a threshold in the variance of phase error versus SNR curves that is a strong function of SNR and a weak function of loop bandwidth. The M-PSK variance thresholds occur at SNR's in the range of practical interest for the use of 8 and 16-PSK TCM. This suggests that phase error variance is an important consideration in the design of these systems.

Osborne, William P.↗

Tidal Stripping of a White Dwarf by an Intermediate-mass Black Hole

During the inspiralling of a white dwarf (WD) into an intermediate-mass black hole (~10 2-5 M ⊙ ), both gravitational waves (GWs) and electromagnetic (EM) radiation are emitted. Once the eccentric orbit's pericenter radius approaches the tidal radius, the WD would be tidally stripped upon each pericenter passage. The accretion of this stripped mass would produce EM radiation. It is suspected that the recently discovered new types of transients, namely the quasiperiodic eruptions and the fast ultraluminous x-ray bursts, might originate from such systems. Modeling these flares requires a prediction of the amount of stripped mass from the WD and the details of the mass supply to the accretion disk. We run hydrodynamical simulations to study the orbital parameter dependence of the stripped mass. We find that our results match the analytical estimate that the stripped mass is proportional to z 5/2 , where z is the excess depth by which the WD overfills its instantaneous Roche lobe at the pericenter. The corresponding fallback rate of the stripped mass is calculated, which may be useful in interpreting the individual flaring light curve in candidate EM sources. We further calculate the long-term mass-loss evolution of a WD during its inspiral and the detectability of the GW and EM signals. The EM signal from the mass-loss stage can be easily detected: the limiting distance is ~320(M h /10 4 M ⊙ ) Mpc for the Einstein Probe. The GW signal, for space-borne detectors such as Laser Interferometer Space Antenna or TianQin, can be detected only within the Local Supercluster (~33 Mpc).

79 ASTRONOMY AND ASTROPHYSICS↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Weakly superconducting, thin-film structures as radiation detectors.

Measurements were taken with weakly superconducting quantum structures of the Notarys-Mercereau type, representing a thin superconductor film with a short region that is weakened in the sense that its transition temperature is lower than in the remaining portion of the film. The structure acts as a superconducting relaxation oscillator in which the supercurrent increases with time until the critical current of the weakened section is attained, at which moment the supercurrent decays and the cycle repeats. Under applied radiation, a series of constant-voltage steps appears in the current-voltage curve, and the size of the steps varies periodically with the amplitude of applied radiation. Measurements of the response characteristics were made in the frequency range of 10 to 450 MHz.

Kirschman, R. K.↗

Spectral evolution of the 5 March 1979 gamma burst

The spectral development of the intense gamma-ray burst observed on March 5, 1979 by nine spacecraft spaced on an interplanetary scale is discussed. As observed by the Pioneer Venus Orbiter detector, the hardness ratio of the burst, defined as the ratio between counts in the 100-1000 keV channels to those in the 50-100 keV channel, decreases during the very fast rise and subsequent 75 msec of the burst, consistent with a decrease in black-body temperature from 30 to 26 keV, and then increases during the shoulder on the gamma-ray burst light curve. Following the burst, the source was observed to exhibit many of the characteristics of a hard X-ray pulsar with a period of 8.0 sec and a hardness ratio varying in phase with the intensity. The observed characteristics of the pulsations are interpreted in terms of hot spots at the magnetic poles of a rotating neutron star, although it is shown that the simple cooling of residual hot spots does not completely explain the pulsations. Alternative explanations for the pulsation include accretion or an effect of beam geometry.

Fenimore, E. E.↗

The International Ultraviolet Explorer

The instrumentation and functioning of the IUE are discussed. The design of the telescope, fine error sensors, echelle spectrographs, and television cameras, as well as their integration, is described. The optical characteristics of the IUE are listed and the schematic arrangement of the detector is depicted. Sources of background noise are assessed, including the thermionic effects in the UV converters and television tubes, radiation from the earth's trapped electron belts, wide angle white light scattering from the earth and sun, scattering of dispersed light caused by low dispersion gratings, photometric calibration, and photometric stability. IUE sensitivity changes during the first three years of operation are shown together with sensitivity curves for short and long wavelengths. Modes of wavelength determination are considered.

Boggess, A.↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from millisecond pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar light-curve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

x-ray↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗