Characterization of Noise in CMOS Ring Oscillators at Cryogenic Temperatures

Allan deviation provides a means to characterize the time-dependence of noise in oscillators and potentially identify the source characteristics. Measurements on a 130 nm, 7-stage ring oscillator show that the Allan deviation declines from 300 K to 150 K as expected, but surprisingly increases from 150 K to 11 K. At low temperatures, the measured Allan deviation can be well fit using a few random telegraph noise (RTN) sources over the range of a few kilohertz to a few gigahertz. Further, the RTN characteristics evolve to reveal an enhanced role in low-frequency noise at lower temperatures.

47 OTHER INSTRUMENTATION↗

Nb$_{3}$Sn SRF Photogun High Power Test at Cryogenic Temperatures

Superconducting RF (SRF) photoguns are emerging as promising candidates to produce highly stable electrons for Ultra fast Electron Diffraction/Microscopy (EUD/UEM) applications due to the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb 3 Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only several Watts of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. Here, in this paper, we present first high power results of the gun covered with Nb 3 Sn.

43 PARTICLE ACCELERATORS↗

Localized exciton emission from monolayer WS 2 nanoribbon at cryogenic temperature

Abstract We conducted low-temperature photoluminescence (PL) spectroscopy experiments on individual WS 2 and MoSe 2 nanoribbons prepared by gold-assisted exfoliation from the slanted surface of bulk crystals with a vicinal and stepwise pattern. The nanoribbons are predominantly monolayer and have widths varying from hundreds of nanometers down to tens of nanometers. Most MoSe 2 NRs display an emission profile similar to 2D excitons of MoSe 2 monolayers. In contrast, WS 2 nanoribbons are characterized with sharp emission peaks that can be attributed to the emission from localized excitons or trions. Moreover a broad low energy emission peak can be also observed from some of the WS 2 nanoribbons, which originates from bilayer regions. In this manuscript, we analyze spectral diffusion behavior along with pump power and temperature dependence of the localized exciton emission peaks, shedding light on potential of TMDC nanoribbons in sensing and opto-electronic applications.

36 MATERIALS SCIENCE↗

First High-Gradient Results of UED/UEM SRF Gun at Cryogenic Temperatures

Benefiting from the rapid progress on RF photogun technologies in the past two decades, the development of MeV range ultrafast electron diffraction/microscopy (UED and UEM) has been identified as an enabling instrumentation. UEM or UED use low power electron beams with modest energies of a few MeV to study ultrafast phenomena in a variety of novel and exotic materials. SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb₃Sn and conduction cooling. The use of Nb₃Sn allows to operate SRF cavities at higher temperatures (4K) with low power dissipation which is within the reach of commercially available closed-cycle cryocoolers. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. In this paper, we present first high gradient results of the gun conducted in liquid helium.

43 PARTICLE ACCELERATORS↗

Electrical and Thermal Properties of Cold-Sprayed Bulk Copper and Copper-Tungsten Samples at Cryogenic Temperatures

The de­vel­op­ment of high ther­mal con­duc­tiv­ity coat­ings with pure cop­per or cop­per-tung­sten alloy could be ben­e­fi­cial to im­prove the heat trans­fer of bulk Nb cav­i­ties for con­duc­tion cool­ing ap­pli­ca­tions and to in­crease the stiff­ness of bulk Nb cav­i­ties cooled by liq­uid he­lium. Cold-spray is an ad­di­tive man­u­fac­tur­ing tech­nique suit­able to grow thick coat­ings of ei­ther Cu or CuW on a Nb sub­strate. Bulk (~5 mm thick) coat­ings of Cu and CuW were de­posited on stan­dard 3 mm thick, high-pu­rity Nb sam­ples and smaller sam­ples with 2 mm x 2 mm cross sec­tion were cut for mea­sur­ing the ther­mal con­duc­tiv­ity and the resid­ual re­sis­tiv­ity ratio. The sam­ples were sub­jected to an­neal­ing at dif­fer­ent tem­per­a­tures and a max­i­mum RRR of ~130 and ~40 were mea­sured for the Cu sam­ples and CuW sam­ples, re­spec­tively.

Pokhrel, H.↗

Mitigation of Dielectric Heating of Piezoelectric Actuators at Cryogenic Temperatures

The new generation of low beam intensity superconducting linacs will require high accelerating gradients for new scientific discoveries. The high accelerating gradient cavities in pulsed SRF linacs will experience large (~1000’s of Hz) detuning caused by Lorentz force detuning (LFD). The piezo actuators that will be used to compensate large LFD must operate at a nominal voltage of 120V to 150V to deliver the required stroke to the cavity. In this high voltage range, the piezo is expected to warm up drastically due to its location in an insulating vacuum environment. Overheating of the piezo will significantly decrease the longevity of the actuator. A collaboration between FNAL and Physik Instrumente (PI) developed a novel piezo actuator design that mitigates piezo overheating. The design consists of using a metal foam in contact with the piezoelectric ceramic stack for heat removal. The second solution used lithium niobite as an alternative material. A comparison of the temperature stability will be presented and discussed. This study characterizes the dielectric properties for both materials. The results obtained are in the temperature range of 10 K to 300 K.

43 PARTICLE ACCELERATORS↗

Electrical and Thermal Properties of Cold-Sprayed Bulk Copper and Copper-Tungsten Samples at Cryogenic Temperatures

The de­vel­op­ment of high ther­mal con­duc­tiv­ity coat­ings with pure cop­per or cop­per-tung­sten alloy could be ben­e­fi­cial to im­prove the heat trans­fer of bulk Nb cav­i­ties for con­duc­tion cool­ing ap­pli­ca­tions and to in­crease the stiff­ness of bulk Nb cav­i­ties cooled by liq­uid he­lium. Cold-spray is an ad­di­tive man­u­fac­tur­ing tech­nique suit­able to grow thick coat­ings of ei­ther Cu or CuW on a Nb sub­strate. Bulk (~5 mm thick) coat­ings of Cu and CuW were de­posited on stan­dard 3 mm thick, high-pu­rity Nb sam­ples and smaller sam­ples with 2 mm x 2 mm cross sec­tion were cut for mea­sur­ing the ther­mal con­duc­tiv­ity and the resid­ual re­sis­tiv­ity ratio. The sam­ples were sub­jected to an­neal­ing at dif­fer­ent tem­per­a­tures and a max­i­mum RRR of ~130 and ~40 were mea­sured for the Cu sam­ples and CuW sam­ples, re­spec­tively.

Pokhrel, H.↗

Superconducting switch permits measurement of small voltages at cryogenic temperatures

Dual-coil, superconducting, on-off switch measures small, thermoelectrically generated voltages produced by thermocouples in a liquid helium bath. Placed in a shunt configuration between the thermocouple and the measuring device, the measuring device sees the sum of the voltage to be measured and the spurious thermoelectric voltages.