Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

A case study of using x-ray Thomson scattering to diagnose the in-flight plasma conditions of DT cryogenic implosions

The design of inertial confinement fusion ignition targets requires radiation-hydrodynamics simulations with accurate models of the fundamental material properties (i.e., equation of state, opacity, and conductivity). Validation of these models is required via experimentation. A feasibility study of using spatially integrated, spectrally resolved, x-ray Thomson scattering measurements to diagnose the temperature, density, and ionization of the compressed DT shell of a cryogenic DT implosion at two-thirds convergence was conducted. Synthetic scattering spectra were generated using 1D implosion simulations from the LILAC code that were post processed with the x-ray scattering model, which is incorporated within SPECT3D. Analysis of two extreme adiabat capsule conditions showed that the plasma conditions for both compressed DT shells could be resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosis of the imploding shell asymmetry in polar-direct-drive deuterium–tritium cryogenic target implosions on OMEGA

We discuss the analyses of gated, x-ray imaging data from polar-direct-drive experiments with cryogenically layered deuterium–tritium targets on the OMEGA laser. The in-flight shell asymmetries were diagnosed at various times during the implosion, which was caused by the beam pointing geometry and preimposed variations in the energy partition between the different groups of laser beams. The shape of the ablation surface during the acceleration phase of the implosion was measured along two different lines of sight, and a Legendre mode (ℓ-mode) decomposition was applied for modes of up to ten to investigate shell asymmetries. A clear causal relationship between the imposed beam imbalance and the shape of the in-flight shell asymmetries was observed. The imploded shell with a balanced energy ratio shows smaller values of the amplitudes of ℓ-mode 2 compared to that from implosions with an imbalanced ring energy ratio. The amplitudes of ℓ-modes 4 and 6 are the same within the measurement uncertainty with respect to the change in beam energy ratio.

47 OTHER INSTRUMENTATION↗

Measurements of low-mode asymmetries in the areal density of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA using neutron spectroscopy

Areal density is one of the key parameters that determines the confinement time in inertial confinement fusion experiments, and low-mode asymmetries in the compressed fuel are detrimental to the implosion performance. The energy spectra from the scattering of the primary deuterium–tritium (DT) neutrons off the compressed cold fuel assembly are used to investigate low-mode nonuniformities in direct-drive cryogenic DT implosions at the Omega Laser Facility. For spherically symmetric implosions, the shape of the energy spectrum is primarily determined by the elastic and inelastic scattering cross sections for both neutron-deuterium and neutron-tritium kinematic interactions. Two highly collimated lines of sight, which are positioned at nearly orthogonal locations around the OMEGA target chamber, record the neutron time-of-flight signal in the current mode. An evolutionary algorithm is being used to extract a model-independent energy spectrum of the scattered neutrons from the experimental neutron time-of-flight data and is used to infer the modal spatial variations (l = 1) in the areal density. Experimental observations of the low-mode variations of the cold-fuel assembly (ρL 0 + ρL 1 ) show good agreement with a recently developed model, indicating a departure from the spherical symmetry of the compressed DT fuel assembly. As a result, another key signature that has been observed in the presence of a low-mode variation is the broadening of the kinematic end-point due to the anisotropy of the dense fuel conditions.

47 OTHER INSTRUMENTATION↗

First bromine doped cryogenic implosion at the National Ignition Facility

We report on the first experiment dedicated to the study of nuclear reactions on dopants in a cryogenic capsule at the National Ignition Facility (NIF). This was accomplished using bromine doping in the inner layers of the CH ablator of a capsule identical to that used in the NIF shot N140520. The capsule was doped with 3 × 1016 bromine atoms. The doped capsule shot, N170730, resulted in a DT yield that was 2.6 times lower than the undoped equivalent. The Radiochemical Analysis of Gaseous Samples (RAGS) system was used to collect and detect 79Kr atoms resulting from energetic deuteron and proton ion reactions on 79Br. RAGS was also used to detect 13N produced dominantly by knock-on deuteron reactions on the 12C in the ablator. High-energy reaction-in-flight neutrons were detected via the 209Bi(n,4n)206Bi reaction, using bismuth activation foils located 50 cm outside of the target capsule. The robustness of the RAGS signals suggests that the use of nuclear reactions on dopants as diagnostics is quite feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of bound valence excited electronic states of deprotonated 2-hydroxytriphenylene using photoelectron, photodetachment, and resonant two-photon detachment spectroscopy of cryogenically cooled anions

Polycyclic aromatic hydrocarbons (PAHs) are common atmospheric pollutants, and they are also ubiquitous in the interstellar medium. Here, we report the study of a complex O-containing PAH anion, the deprotonated 2-hydroxytriphenylene (2-OtPh–), using high-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled anions. Vibrationally resolved photoelectron spectra yield the electron affinity of the 2-OtPh radical as 2.629(1) eV and several vibrational frequencies for its ground electronic state. Photodetachment spectroscopy reveals bound valence excited electronic states for the 2-OtPh– anion, with unprecedentedly rich vibronic features. Evidence is presented for a low-lying triplet state (T1) and two singlet states (S1 and S2) below the detachment threshold. Single-color resonant two-photon photoelectron spectroscopy uncovers rich photophysics for the 2-OtPh– anion, including vibrational relaxation in S1, internal conversion to the ground state of 2-OtPh–, intersystem crossing from S2 to T1, and a long-lived autodetaching shape resonance about 1.3 eV above the detachment threshold. The rich electronic structure and photophysics afforded by the current study suggest that 2-OtPh– would be an interesting system for pump–probe experiments to unravel the dynamics of the excited states of this complex PAH anion.

Chemistry↗

Self-generated magnetic fields in the hot spot of direct-drive cryogenic implosions at Omega

This work reports that Biermann self-generated magnetic fields of ≈200 MG and Hall parameters of ≈1.5 are produced in the stagnation phase of direct-drive cryogenic implosions at Omega. The magnetic fields produce a drop of 2.4% in fusion yield and 1% in ion temperature. A quantitative estimate of the effect of self-generated magnetic fields on yield and ion temperature is essential, since direct measurements of these fields are not available. Reconstructed simulations of the 50 Gbar implosions, with all the stagnation measurements reproduced simultaneously by a combination of mid- and low-mode asymmetries as degradation mechanisms [Bose et al., Phys. Plasmas 25, 062701 (2018)], are used to obtain the estimates. The magnetic fields cause a decrease in yield due to the Righi–Leduc heat flow, which exceeds any benefits from heat flow suppression due to magnetization. It is important to note that both direct-drive Omega-scale implosions and indirect-drive National Ignition Facility (NIF)-scale implosions [Walsh et al., Phys. Rev. Lett. 118, 155001 (2017)] produce similar estimates for the magnetic field strength, and both show a decrease in fusion yield, with the Righi–Leduc transport as the loss mechanism. However, the yield degradation at Omega is small and lower by ≈5× compared to the indirect-drive ignition-scale NIF estimate.

Physics↗

Exploring direct photodetachment and photodissociation–photodetachment dynamics of platinum iodide anions (PtI n - , n = 2–5) using cryogenic photoelectron spectroscopy

The direct photodetachment and two-photon photodissociation–photodetachment processes of a series of PtI n - (n = 2–5) anions were systematically studied using cryogenic anion photoelectron spectroscopy and first-principles electronic structure calculations. The adiabatic/vertical detachment energies (ADEs/VDEs) of these anions were determined from their 193 nm photoelectron (PE) spectra, i.e., 3.54/3.63, 4.04/4.09, 4.33/4.36, and 4.37/4.41 eV for n = 2–5, respectively, and well reproduced by B3LYP-D3(BJ)/aug-cc-pVTZ-pp calculations. As the coordination number increases, the electron affinity (EA) of PtI n • (n = 2–5) neutrals (equivalent to the corresponding anion’s ADE) gradually increases, exceeding the EA of Cl at n = 3 and exhibiting superhalogen characteristics for n ≥ 3. Meanwhile, the ground state transition contributed from detaching electrons in the highest occupied molecular orbital gradually evolves from the central metal Pt to the iodine ligands. For the PtI 3 - anion, besides one-photon direct detachment, four distinct two-photon photodissociation–photodetachment channels were identified, and the competition between them was discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isomers and band assignments in the cryogenic vibrational spectrum of the binary complex between water and protonated formic acid using two color, IR–IR photobleaching and H/D isotopic substitution

Protonated formic acid (PFA) is purported to be the active species in the catalytic activation of condensation reactions at the acidic interface of microdroplets. Here, we investigate the fundamental interaction between PFA and water with cryogenic ion vibrational spectroscopy of the binary PFA–H 2 O complexes generated via electrospray ionization followed by buffer gas cooling to about 20 K. The patterns displayed by the isomer-specific IR spectra of D 2 -tagged PFA–H 2 O indicate that two distinct, non-interconverting rotamers are present at low temperatures based on the cis and trans structures of the HCO 2 $H$$^{+}_{2}$ core ion. Both of these occur with the water molecule attached to the OH that is in a cis-configuration relative to the CH group (denoted E), but differ in the E vs Z (cis vs trans relative to the CH group) orientation of the spectator OH. This assignment scheme corrects a previous theoretical analysis that invoked a scenario in which structures with E- and Z-bound water molecules interconvert at low (20 K) temperatures. Isomer-specific bands arising from the OH stretches and water bending modes are deconvoluted using isotopomer-specific spectroscopy of the complexes with partial H/D exchange. The dependence of the nominal shared proton OH stretch frequency on the deuteration of the tethered water confirms strong coupling between this mode and the water bending fundamental.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L↗

A high-efficiency cryogenic neutron spin flipper for IMAGINE-X at the high flux isotope reactor

The Laue neutron macromolecular crystallography beamline, IMAGINE, at the High Flux Isotope Reactor (HFIR) is undergoing a major upgrade to incorporate the dynamic nuclear polarization (DNP) technique. Upon completion, the new IMAGINE-X instrument is expected to enhance the signal-to-noise ratio of the diffraction data by an order of magnitude. To take full advantage of the benefits of DNP, both a highly polarized neutron beam and a high-efficiency neutron spin flipper are required. We have developed a compact cryogenic spin flipper utilizing the Meissner effect in high-Tc yttrium–barium–copper–oxide superconducting films. The flipper has been successfully tested at two HFIR neutron development beamlines, Larmor and Poplar, with neutron wavelengths of 5.3 and 2.4 Å respectively. At Larmor, a flipping efficiency of 0.995 ± 0.004 was achieved for 5.3 Å neutrons, and at Poplar, efficiency of up to 0.9987 ± 0.0004 was obtained for 2.4 Å neutrons. Both tests demonstrated the flipper’s excellent performance and suitability for integration into IMAGINE-X.

Fu, Sichao [Oak Ridge National Laboratory (ORNL), ↗

High-resolution vibrational predissociation spectroscopy of I - ·H 2 O by single-mode CW infrared excitation in a 3D cryogenic ion trap

We describe the integration of a tunable, single-mode, continuous wave infrared laser into a cryogenic ion spectroscopy experiment to measure the rovibrational spectrum of the I - ∙H 2 O complex in the OH stretching region. These upper levels lie about 300 cm -1 above the dissociation threshold. The measurements are carried out by loading the ions in a radiofrequency ion trap at 10 Hz and cooling them to 5 K with pulsed He buffer gas. IR photodissociation (PD) of the I - ∙H 2 O complex is monitored by recording the I - product yield by time-of-flight mass spectrometry as a function of laser wavelength. Very narrow (Δν~75 MHz) rotational lines are observed throughout the spectrum, indicating long (ca. 2 ns) lifetimes for the excited metastable rovibrational levels. Rotational analysis of the band arising from the K”=1 to K’=2 transition of the free OH stretching fundamental yields the structure of the complex for the first time. Over 50% of the trapped ion ensemble in the trap can be photodissociated upon excitation of a single rotational line. This enables very high signal-to-noise in the PD spectrum, and is traced to a mechanism in which the ground state rotational levels are rapidly equilibrated by collisions with the buffer gas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Spallation Neutron Source Hydrogen Relief Analysis for the Cryogenic Moderator System

The Spallation Neutron Source at Oak Ridge National Laboratory operates the Cryogenic Moderator System (CMS) which provides hydrogen cooling at 20K to three neutron moderators. Each hydrogen loop is protected by multiple burst discs and reclosing relief valves. As a result of the Proton Power Upgrade project, the CMS moderator loops will hold more hydrogen and thus require piping modifications. Operational experience has demonstrated that transient pressure increases in these hydrogen loops occasionally result in the rupture of the burst discs. The causes for pressure transients in the system that might lead to hydrogen venting are varied and complex, for example loss of vacuum or cooling. Dynamic simulation and analysis of the parameters considered as the worst-case relief venting scenario were performed and will be presented.

47 OTHER INSTRUMENTATION↗