Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Container”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Evaluating Corrosion Effects on the Stainless Steel Components of the SAVY-4000/Hagan Nuclear Material Storage Containers

Surveillance of vented, stainless-steel Hagan and SAVY-4000 storage containers with some plutonium materials has revealed evidence of corrosion inside the container. There are ~3000 items stored in Hagan containers and ~600 items currently stored in SAVY-4000 containers at TA -55. The Hagan is made of 304L steel, while the SAVY-4000 is made of 316L and should be less susceptible to corrosion. Given the relatively thin body wall of these containers (nominally 0.762 millimeters), it is essential to understand the effects of corrosion on the lifetime of the containers to ensure worker safety. Studies are being conducted on both container types to determine the relative susceptibility of the two containers to corrosion. This paper describes the potential cause of corrosion, the extent of corrosion, and types of corrosion observed, along with the results of accelerated aging experiments. The combined results of the surveillance and lifetime extension studies establish a technical basis for extending the design life of the stainless steel components of the SAVY-4000 container from 5 years to 15 years.

36 MATERIALS SCIENCE↗

Drop Analysis of the Advanced Test Reactor Fresh Fuel Shipping Container with Heavier Low-Enriched Uranium Fuel Contents

The Advanced Test Reactor Fresh Fuel Shipping Container (ATR FFSC) is a rectangular stainless steel container used for shipping radioactive material. The container is described in the ATR FFSC Safety Analysis Report (SAR). Per the ATR FFSC SAR, the ATR FFSC is designated a Type AF-96 packaging per the definition of 10 CFR §71.4, and was originally designed to transport high enriched uranium (HEU) reactor fuel elements for the Advanced Test Reactor (ATR), the Advanced Test Reactor Critical (ATRC) facility, the Massachusetts Institute of Technology Reactor (MITR), and the University of Missouri Research Reactor (MURR). The Department of Energy, National Nuclear Security Administration’s (NNSA), Office of Material Management and Minimization (M3) is working with the Idaho National Laboratory (INL) to develop and qualify new low enriched uranium (LEU) fuels and technologies for use in the ATR, ATRC, MITR, and MURR reactors. The LEU fuel elements will weigh significantly more than the current HEU designs and, combined with their associated Fuel Handling Enclosures for packaging, some configurations will exceed the 50 lbf used in the ATR FFSC qualifying drop tests. There are LEU versions of MITR, MURR, and ATR fuel elements. However, for this evaluation, drop analysis of the ATR FFSC with only the heavier ATR Low Enrichment (LOWE) fuel element is considered in this evaluation because the LOWE fuel element is the heaviest of the considered LEU fuel elements. The ATR HEU fuel element and the ATR LOWE fuel element are identical in every design aspect except for the fuel meat inside the 19 fuel plates. The LEU fuel meats are made using a U-10Mo high-density foil rather than uranium dispersed in aluminum in the HEU fuel elements. The high density of the uranium in the LEU fuel meat increases the LOWE fuel element weight to just under 44 lbf (versus the 22.1 lbf weight of the tested ATR HEU fuel element). ATR fuel elements are placed in a thin-gauge aluminum weldment called a "Fuel Handling Enclosure" during packaging. The Fuel Handling Enclosure is used to cover and protect the element during loading and unloading operations. The ATR Fuel Handling Enclosure weighs about 15 lbf per the drawings in the ATR FFSC SAR and the weight is accounted for in this evaluation. Transporting the heavier LEU fuel elements require evaluation of two issues. The first is the effect of the increased mass of the LEU fuel elements on the survivability of the ATR FFSC package following the requisite drop qualifications. The second is the effect of the increased mass of the fuel plates on the fuel element during the same drops. The ATR FFSC containing an ATR HEU fuel element in an ATR Fuel Handling Enclosure was physically dropped multiple times to qualify the container as a Type AF-96 package. The ATR FFSC SAR describes the drop tests performed with an actual ATR HEU fuel element weighing 22.1 lbf contained in a 14.3 lbf Fuel Handling Enclosure for a total payload of 36.4 lbf. Those drop tests showed that the ATR FFSC maintained containment of the ATR HEU fuel element and the fuel element was not significantly damaged. (Containment herein is not defined as a leak tight but is retention of the radioactive contents.) The purpose of the evaluation is to analytically show that, for a similar set of tests, the ATR FFSC maintains containment of the heavier ATR LOWE fuel element and to assess the damage to the fuel element during the drops. The approach was to create finite element analysis (FEA) models that produce the same results as the physical drops. Those models were then used as the benchmarks for the follow-on analyses using the heavier contents. FEA models of the drops of ATR FFSC using up to a 115 lbf fuel element were run and evaluated. Likewise, drops of a LOWE fuel element weighing 44 lbf in the ATR FFSC were run and evaluated. It is important to note that this report was done at the quality level necessary to be included in a nuclear facility safety basis. However, it is not the intent of this report to conclude the suitability of the ATR FFSC for transporting the heavier payloads. This report only describes the results of the FEA as related to the required drop scenarios. Incorporation of the FEA into the safety basis will be evaluated by the ATR FFSC design authority. The physical drop tests of the HEU fuel element and FEA drop analysis for the LOWE fuel element showed noteworthy damage to the fuel plates. An aluminum protective block was conceived to mitigate the damage. The concept requires the blocks to be placed in the fuel element between the end boxes and fuel plates. Additional FEA drop analyses were performed using the protective block. The addition of the blocks is primarily intended to mitigate the damage to the LOWE fuel element fuel plates. However, FEA drop analyses of the ATR HEU fuel element with the blocks were also performed and included for information.

42 ENGINEERING↗

Rules of Use Report Engineering evaluations of nuclear material storage containers against the packaging requirements at TA-55

A set of obligations in the yearly storage container surveillance program, ensures that a retrospective approach is applied with loaded containers in inventory to confirm compliance with all “users” to ensure nuclear material storage container requirements are being followed. Validation that packaged containers are properly used, within a specific set of container types prescribed “bounding conditions of use,” is based on meeting requirements as identified in operating procedures associated with TA55-DOP-091, TA-55 Nuclear Material Packaging, and PA-RD-01022, Nuclear Material Packaging Requirements. The surveillance plan obligation requires the application of local area nuclear material accountability software or (LANMAS) to produce queries. The data queries are used to assess attributes of containers in storage these investigations are conducted on a bi-annual basis. This rules of use (ROU) compliance process ensures proper usage of storage containers as containment systems and therefore provides effective worker protection. It is structured as a supporting effort by implementing aspects of PA-AP-01207, Nuclear Material Container Safety Management at TA-55.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Engineering evaluations of nuclear material storage containers against the packaging requirements at TA-55 (FY22 Rules of Use Report)

A set of obligations in the yearly storage container surveillance program, ensures that a retrospective approach is applied with loaded containers in inventory to confirm compliance with all “users” to ensure nuclear material storage container requirements are being followed. Validation that packaged containers are properly used, within a specific set of container types prescribed “bounding conditions of use,” is based on meeting requirements as identified in operating procedures associated with TA55-DOP-091, TA-55 Nuclear Material Packaging, and PA-RD-01022, Nuclear Material Packaging Requirements. The surveillance plan obligation requires the application of local area nuclear material accountability software or (LANMAS) to produce queries. The data queries are used to assess attributes of containers in storage these investigations are conducted on a bi-annual basis. This rules of use (ROU) compliance process ensures proper usage of storage containers as containment systems and therefore provides effective worker protection. It is structured as a supporting effort by implementing aspects of PA-AP-01207, Nuclear Material Container Safety Management at TA-55.

36 MATERIALS SCIENCE↗

A Demonstration of Intelligent Container Surveillance Using Stationary and Mobile Camera Platforms

Surveillance of nuclear material storage containers is required to ensure that the container safety boundary is maintained during the service life of the container. As many of these container types are the first and only containment barrier to release protecting the worker, public, and environment, it is imperative to develop robust surveillance tools to characterize container degradation. Machine learning (ML) techniques have matured quickly in the past decade and are slowly becoming a routine application in data analysis. While more popular architectures have been developed with different applications in mind, these can be easily translated to container surveillance requirements. In this study, we developed a ML model based on the Detectron2 framework to identify slip lid containers and common exterior container defects, primarily dents. Commercial-off-the-shelf cameras are combined into a stationary camera array or are mounted to a robotic arm to provide more mobility for positioning needs. Results from the model evaluations on the images indicate that the stationary camera arrays outperform the accuracy of the mobile camera systems for both individual camera and composite image detections. Overall, however, the detection accuracies of the systems fell short of 50% and were less than satisfactory. Future efforts to improve the system involve focusing on a single camera deployable solution that combines a controllable light source that eliminates one of the biggest environmental factors that influence ML model detection performance. Additional training set collection is planned to build a more robust model that enables accurate detection from a wider range of imaging conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of 3013 Containers Baseline Surface Features

The Surveillance and Monitoring Program at Los Alamos National Laboratory (LANL) was tasked with evaluating the baseline features of 3013 containers. This baseline is to be used as a basis for comparison for 3013 containers that had been packaged with corrosive plutonium materials. The LANL team evaluated an unwelded container, an unused welded container, and a welded container that had held plutonium metal without any corrosive impurities. These three containers had features with depths no larger than 6 µm and had similar depth distributions. The features observed in the baseline containers were all shallower than those seen in containers packaged with corrosive plutonium materials. This work establishes workflows for feature identification and measurement, as well as establishment of baseline data for future comparison with corroded containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Vertex-Aligned Model for Packing 4-Hexagonal Clusters in a Regular Hexagonal Container

This paper deals with a problem the packing polyhex clusters in a regular hexagonal container. It is a common problem in many applications with various cluster shapes used, but symmetric polyhex is the most useful in engineering due to its geometrical properties. Hence, we concentrate on mathematical modeling in such an application, where using the “bee” tetrahex is chosen for the new Compact Muon Solenoid (CMS) design upgrade, which is one of four detectors used in Large Hadron Collider (LHC) experiment at European Laboratory for Particle Physics (CERN). We start from the existing hexagonal containers with hexagonal cells packed inside, and uniform clustering applied. We compare the center-aligned (CA) and vertex-aligned (VA) models, analyzing cluster rotations providing the increased packing efficiency. We formally describe the geometrical properties of clustering approaches and show that cluster sharing is inevitable at the container border with uniform clustering. In addition, we propose a new vertex-aligned model decreasing the number of shared clusters in the uniform scenario, but with a smaller number of clusters contained inside the container. Also, we describe a non-uniform tetrahex cluster packing scheme in the proposed container model. With the proposed cluster packing solution, it is accomplished that all clusters are contained inside the container region. Since cluster-sharing is completely avoided at the container border, the maximal packing efficiency is obtained compared to the existing models.

97 MATHEMATICS AND COMPUTING↗

Aluminum-fiber composites containing intermetallic phase at the matrix-fiber interface

A solid aluminum-fiber composite comprising: (i) an aluminum-containing matrix comprising elemental aluminum; (ii) coated or uncoated fibers embedded within said aluminum-containing matrix, wherein said fibers have a different composition than said aluminum-containing matrix and impart additional strength to said aluminum-containing matrix as compared to said aluminum-containing matrix in the absence of said fibers embedded therein; and (iii) an intermetallic layer present as an interface between each of said fibers and the aluminum-containing matrix, wherein said intermetallic layer has a composition different from said aluminum-containing matrix and said fibers, and said intermetallic layer contains at least one element that is also present in the aluminum-containing matrix and at least one element present in the fibers, whether from the coated or interior portion of the fibers. Methods of producing the above-described composite are also described.

Rios, Orlando↗

Load planning in the dark: RH-TRU waste container load planning at Sandia National Laboratories/New Mexico - 15116

Sandia National Laboratories (Sandia) performed several sets of experiments during the 1970's and 1980's with fresh and irradiated mixed oxide (MOX) and uranium oxide (UO{sub 2}) materials designed to simulate various fuel responses under varying reactor conditions. These research materials were from light water and breeder mixed oxide reactors. The experimental vessels and extraneous piece parts resulting from the experiments were identified as eligible for disposal at the Waste Isolation Pilot Plant (WIPP) as remote-handled (RH) transuranic (TRU) waste. Once Sandia received the approval to dispose at WIPP, discussions began with the Carlsbad Field Office (CBFO) and Nuclear Waste Partnerships, LLC (NWP) to provide Central Characterization Program (CCP) support for certified acceptable knowledge, visual examination, and dose-to-curie for the repackaging effort. In addition to the WIPP support, Sandia was required to prepare a load plan describing the configuration of the parent containers and how they could be repackaged to meet WIPP and other regulatory requirements. However, all of these containers were packaged as material twenty (20) or thirty (30) years ago and the records of the packaging process and configuration were not documented as waste. Therefore, it seemed that the load plans were prepared with limited information regarding parent container configuration, hence in the dark. The design of the Auxiliary Hot Cell Facility (AHCF) in technical area (TA) V, where the repackaging was to take place, along with the shipping requirements for the RH 72-B cask, limited the options for repackaging. This configuration required that 0.114 m{sup 3} (30-gallon) containers be packaged in the hot cell, removed and placed into 0.208 m{sup 3} (55-gallon) containers to mitigate contamination issues. The material had been tracked as accountable nuclear material and Sandia had verified Material Control and Accountability (MC and A) data on each parent container. Based on the MC and A data, scaling factors could be determined and sampling and analysis was not required. However, it meant that parent containers could not be split into two daughter containers, though two or more parent containers could be combined into one daughter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drop Testing of a Container for the Storage, Transport and Disposal of Intermediate Level Waste - 18078

Impact tests were performed, as part of a corresponding container's substantiation, during design development of a shielded container proposed for use at Sellafield for waste retrieval from the First Generation Magnox Storage Pond (FGMSP) in the UK. The mechanical test program comprised a 9 m free drop test onto an unyielding target in a container long lid edge down orientation at ambient conditions. Further, a 0,5 m free drop test onto a punch target was performed. Here, the container was orientated with the lid downwards in a way that the punch, a mild steel bar, impacts a filter lid. The test specimen was instrumented with strain gauges and accelerometers for the drop tests. Transient strains at selected points of the inner and outer container walls, at the shielding lid, as well as at the lid bolts were measured during the container's impact. Furthermore, decelerations of the container body, container lid, and the skip were measured. The complex geometrical changes of the container due to impact were determined by optical 3d- deformation measures using the projected fringes method in combination with multi-image photogrammetry. This paper summarizes the performance of the drop tests and various drop test results in context with the design development as well as aspects regarding the associated Finite Element (FE) analyses and post-test evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water Ingress Testing of the Turbula Jar and U-233 Lead Pig Containers

Understanding the water ingress behavior of containers used at the TA-55 Plutonium Facility has significant implications for criticality safety. The purpose of this report is to document the water ingress behavior of the Turbula Jar with Bakelite lid and Viton gaskets (Turbula Jar) used in oxide blending operations and the U-233 lead pig container used to store and transport U-233 material. The technical basis for water resistant containers at TA-55 is described in LA-UR-15-22781, “Water Resistant Container Technical Basis Document for the TA-55 Criticality Safety Program.” Testing of the water ingress behavior of various containers is described in LA-CP-13-00695, “Water Penetration Tests on the Filters of Hagan and SAVY Containers,” LA-UR-15-23121, “Water Ingress into Crimped Convenience Containers under Flooding Conditions,” and in LA-UR- 16-2411, “Water Ingress Testing for TA-55 Containers.” Water ingress criteria are defined in TA55-AP-522 “TA-55 Criticality Safety Program”, and in PA-RD-01009 “TA55 Criticality Safety Requirements.” The water ingress criteria for submersion is no more than 50 ml of water ingress at a 6” water column height for a period of 2 hours.

42 ENGINEERING↗

He Leak Testing of 3013 Inner Container Lids

The 3013-container package is used for the long-term storage of plutonium bearing materials at Department of Energy (DOE) sites. The package consists of three nested stainless-steel containers: outer, inner and convenience, which are made of stainless steel. The requirements of the DOE 3013 Standarda, also entail the development of a surveillance program, tasked to ensure structural integrity of the outer container for at least 50 years. The Materials Identification and Surveillance Working Group (MIS-WG) is specified to be responsible for selecting the containers for the surveillance as well as analyzing results. The MIS-WG determined that corrosion is a potential mechanism for container degradation with the most credible type of failure to be stress corrosion cracking (SCC) through wall breach of the inner container closure weld region (ICCWR). A breach of the inner container has the potential of allowing corrosive gases to be released into the safety class outer container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers

Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub’s primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers.

97 MATHEMATICS AND COMPUTING↗

Residual Stresses in SAVY 4000 and Hagan Container Bodies

Chloride-induced stress corrosion cracking (SCC) has been investigated as a potential failure mechanism for the SAVY 4000 and the Hagan containers used to store plutonium-bearing materials at Los Alamos National Laboratory. This report discusses the regions of the container bodies most susceptible to SCC and the magnitude of the residual stresses in those regions. Boiling MgCl2 testing indicated that for both containers the region near the top weld was most susceptible to SCC. The Hagan showed through wall cracking after 22-24 hours of exposure both parallel (axial stresses) and perpendicular (hoop stresses) to the weld. The SAVY 4000 container showed significant cracking above and below the weld after 47 hours of exposure but there was no visual evidence of a through wall crack and the cracks did not leak water. Two through wall holes formed in the bottom of the SAVY 4000 container after 44-46 hours of exposure. For both containers, average “through wall” residual stresses were determined from hole drilling data 4 mm below the weld. In the Hagan body, average tensile hoop stresses were 194 MPa and average compressive axial stresses were -120 MPa. In the SAVY 4000 body, average compressive hoop stresses were 11 MPa and average tensile axial stresses were 25 MPa. Results suggest that because the Hagan container exhibited through wall cracking in a shorter time in boiling MgCl2 and had the higher average tensile stress, 194 MPa hoop stress, it is more susceptible to SCC than the SAVY 4000 container.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surveillance Report on SAVY-4000 and Hagan Nuclear Material Storage Containers for FY 2017

In accordance with the SAVY-4000 Surveillance Plan [1] and DOE M441.1-1 requirements, storage container surveillance continued through fiscal year 2017 at Los Alamos National Laboratory. Surveillance items for the year consisted of 8 SAVY-4000 storage containers, 8 Hagan containers, and 39 SAVY-4000 transfer containers. The SAVY-4000 surveillance items ranged in age from 1 year to 5.6 years and the Hagan containers ranged in age from 6.3 years to 17.6 years. The surveillance containers for this year were selected primarily to better understand the extent of corrosion of the stainless steel components of the containers. Accelerated aging studies indicate that the O-ring and filter components of the SAVY-4000 will last at least 40 years under LANL storage conditions. However, the observation of corrosion on the inside of SAVY-4000 and Hagan surveillance containers has shifted the emphasis to understanding both the nature and the extent of corrosion on the stainless steel body. The restriction on handling soluble residues greater than 500 grams continued this year, delaying the surveillance of some items that was scheduled in earlier surveillance plans.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gas composition observed by destructive examination of 3013 containers

The Department of Energy’s Integrated Surveillance and Monitoring Program implements requirements to measure gas pressure and gas composition during destructive examination of 3013 containers as required by DOE’s 3013 Standard. Gas pressures and gas compositions measured by the Program during destructive examination of 3013 containers from 2007 to 2017 are reported here. The maximum gas pressure within the population of containers that have undergone destructive examination was 299 kPa (43.4 psia) and this container had 0.52 wt% moisture which is higher than the Standard allows. The majority of containers have essentially no gas pressurization. Hydrogen was quantifiable above the measurement uncertainty in less than half (47 out of 114) of the containers that have undergone destructive examination. The amount of hydrogen that is generated within the sealed 3013 containers is always less than the amount predicted by the 3013 Standard’s pressure equation with the maximum observed hydrogen fraction (observed moles of hydrogen/predicted moles of hydrogen) of 0.18. It is recommended that for the purposes of calculating a maximum hydrogen pressure using the 3013 equation, a correction to the amount of hydrogen produced from decomposition of the water be incorporated. The pressure (or moles) of H 2 should be reduced by multiplying by a hydrogen fraction as described in the text. Helium and nitrogen are the other major constituents. Oxygen which is initially present in nearly all of the containers undergoing destructive examination was consumed to low values in all cases. The highest observed oxygen concentration was 1.7%, and in this case the H 2 concentration was essentially zero. Other minor gases observed in some cases included CO 2 with maximum content of 3.5%, CO with maximum content of 0.8%, N 2 O with maximum content of 1.4%, and CH 4 with maximum content of 0.4%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗